RF Exposure Info

FCC ID: VPYLBYD

RF Exposure Info

Download: PDF
FCCID_2182002

                                      RF Exposure / MPE Calculation
                                            No. : 10124906H
                  Applicant            :     Murata Manufacturing Company, Ltd.
                  Type of Equipment    :     Communication Module
                  Model No.            :     TypeYD
                  FCC ID               :     VPYLBYD


Murata Manufacturing Company, Ltd. declares that Model : TypeYD                                   ⇒
complies with FCC radiation exposure requirement specified in the FCC Rule 2.1091 (for mobile).


RF Exposure Calculations:                                                                         ←

The following information provides the minimum separation distance for the highest gain
antenna provided with the “TypeYD“ as calculated
from (B) Limits for General Population / Uncontrolled Exposure of
TABLE 1- LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) of §1.1310 Radiofrequency
radiation exposure limits.
This calculation is based on the highest EIRP possible from the system,
considering maximum power and antenna gain, and considering a 1.0mW/cm^2 uncontrolled
exposure limit. The Friis formula used was:



          S = (P * G) / (4* π * r2)
Where
             P=      50.35 mW (Maximum average output power)
             G=       0.69 Numerical Antenna gain; equal to  -1.60 dBi
             r=       20.0 cm




For: TypeYD                                                  S=    0.00693 mW/cm2



Document Created: 2014-01-24 11:39:33
Document Modified: 2014-01-24 11:39:33

© 2024 FCC.report