RF EX

FCC ID: VPYLBTN

RF Exposure Info

Download: PDF
FCCID_1512716

                                      RF Exposure / MPE Calculation
                                           No. : 31KE0354-HO
                  Applicant            :     Murata Manufacturing Co., Ltd.
                  Type of Equipment    :     Communication Module (WLAN part)
                  Model No.            :     LBEE5ZSTNC
                  FCC ID               :     VPYLBTN


Murata Manufacturing Co., Ltd. declares that Model : LBEE5ZSTNC                                    ⇒
complies with FCC radiation exposure requirement specified in the FCC Rules 2.1091 (for mobile).


RF Exposure Calculations:                                                                          ←

The following information provides the minimum separation distance for the highest gain
antenna provided with the “LBEE5ZSTNC“ as calculated
from FCC OET Bulletin 65 Appendix A, Table (B) Limits for General Population / Uncontrolled
Exposure. This calculation is based on the highest EIRP possible from the system,
considering maximum power and antenna gain, and considering a 1.0mW/cm^2 uncontrolled
exposure limit. The Friis formula used was:



          S = (P * G) / (4* π * r2)
Where
             P=    264.24 mW (Maximum peak output power)
             G=      1.20 Numerical Antenna gain; equal to            0.80 dBi
             r=      20.0 cm




For: LBEE5ZSTNC                                              S=    0.06320 mW/cm2




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2011-07-29 10:03:09
Document Modified: 2011-07-29 10:03:09