Test Report (DTS-BT LE Conducted test)_rev

FCC ID: VPYLB1DX

Test Report

Download: PDF
FCCID_3039909

                                           FCC Test Report (Conducted Test)

                       Report No.: RF151228C18B-2

                            FCC ID: VPYLB1DX

                       Test Model: 1DX

                 Received Date: Dec. 28, 2015

                         Test Date: Jan. 07 ~ Jun. 07, 2016

                     Issued Date: Jun. 13, 2016


                         Applicant: Murata Manufacturing Co., Ltd.

                          Address: 10-1, Higashikotari 1-chome, Nagaokakyo-shi, Kyoto 617-8555, Japan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: RF151228C18B-2                                           Page No. 1 / 23                                            Report Format Version: 6.1.1
Reference No. 160527C13


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 4
1         Certificate of Conformity...................................................................................................................... 5
2         Summary of Test Results ..................................................................................................................... 6
    2.1      Measurement Uncertainty ................................................................................................................... 6
    2.2      Modification Record ............................................................................................................................ 6
3         General Information .............................................................................................................................. 7
    3.1      General Description of EUT ................................................................................................................ 7
    3.2      Description of Test Modes ................................................................................................................... 8
    3.2.1    Test Mode Applicability and Tested Channel Detail............................................................................. 9
    3.3      Description of Support Units ............................................................................................................. 10
    3.3.1    Configuration of System under Test .................................................................................................. 10
    3.4      General Description of Applied Standards ........................................................................................ 10
4         Test Types and Results ....................................................................................................................... 11
    4.1      Conducted Emission Measurement ................................................................................................... 11
    4.1.1    Limits of Conducted Emission Measurement ..................................................................................... 11
    4.1.2    Test Instruments ................................................................................................................................. 11
    4.1.3    Test Procedures.................................................................................................................................. 11
    4.1.4    Deviation from Test Standard ............................................................................................................ 12
    4.1.5    Test Setup .......................................................................................................................................... 12
    4.1.6    EUT Operating Conditions................................................................................................................. 12
    4.1.7    Test Results ....................................................................................................................................... 13
    4.2      6dB Bandwidth Measurement ........................................................................................................... 15
    4.2.1    Limits of 6dB Bandwidth Measurement ............................................................................................. 15
    4.2.2    Test Setup .......................................................................................................................................... 15
    4.2.3    Test Instruments ................................................................................................................................ 15
    4.2.4    Test Procedure .................................................................................................................................. 15
    4.2.5    Deviation fromTest Standard ............................................................................................................. 15
    4.2.6    EUT Operating Conditions................................................................................................................. 15
    4.2.7    Test Result ......................................................................................................................................... 16
    4.3      Conducted Output Power Measurement........................................................................................... 17
    4.3.1    Limits of Conducted Output Power Measurement ............................................................................ 17
    4.3.2    Test Setup .......................................................................................................................................... 17
    4.3.3    Test Instruments ................................................................................................................................ 17
    4.3.4    Test Procedures................................................................................................................................. 17
    4.3.5    Deviation from Test Standard ............................................................................................................ 17
    4.3.6    EUT Operating Conditions................................................................................................................. 17
    4.3.7    Test Results ....................................................................................................................................... 17
    4.4      Power Spectral Density Measurement .............................................................................................. 18
    4.4.1    Limits of Power Spectral Density Measurement ............................................................................... 18
    4.4.2    Test Setup .......................................................................................................................................... 18
    4.4.3    Test Instruments ................................................................................................................................ 18
    4.4.4    Test Procedure .................................................................................................................................. 18
    4.4.5    Deviation from Test Standard ............................................................................................................ 18
    4.4.6    EUT Operating Condition .................................................................................................................. 18
    4.4.7    Test Results ....................................................................................................................................... 19
    4.5      Conducted Out of Band Emission Measurement .............................................................................. 20
    4.5.1    Limits of Conducted Out of Band Emission Measurement ............................................................... 20
    4.5.2    Test Setup .......................................................................................................................................... 20
    4.5.3    Test Instruments ................................................................................................................................ 20
    4.5.4    Test Procedure .................................................................................................................................. 20
    4.5.5    Deviation from Test Standard ............................................................................................................ 20
    4.5.6    EUT Operating Condition .................................................................................................................. 20
    4.5.7    Test Results ....................................................................................................................................... 21

Report No.: RF151228C18B-2                                           Page No. 2 / 23                                             Report Format Version: 6.1.1
Reference No. 160527C13


5       Pictures of Test Arrangements .......................................................................................................... 22
Appendix – Information on the Testing Laboratories ................................................................................ 23




Report No.: RF151228C18B-2                                   Page No. 3 / 23                                       Report Format Version: 6.1.1
Reference No. 160527C13


                                         Release Control Record


Issue No.             Description                                        Date Issued
RF151228C18B-2        Original release                                   Jun. 13, 2016




Report No.: RF151228C18B-2                  Page No. 4 / 23       Report Format Version: 6.1.1
Reference No. 160527C13


1    Certificate of Conformity


            Product: Communication Module

              Brand: MURATA

        Test Model: 1DX

    Sample Status: Engineering sample

          Applicant: Murata Manufacturing Co., Ltd.

          Test Date: Jan. 07 ~ Jun. 07, 2016

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
                        ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             , Date:         Jun. 13, 2016
                              Polly Chien / Specialist




     Approved by :                                              , Date:         Jun. 13, 2016
                             Ken Liu / Senior Manager




Report No.: RF151228C18B-2                    Page No. 5 / 23                        Report Format Version: 6.1.1
Reference No. 160527C13


2      Summary of Test Results


                               47 CFR FCC Part 15, Subpart C (Section 15.247)

        FCC
                               Test Item                   Result                    Remarks
       Clause
                                                                      Meet the requirement of limit.
       15.207      AC Power Conducted Emission              Pass      Minimum passing margin is -29.68dB
                                                                      at 0.73984MHz.
    15.205 & 209   Radiated Emissions and                   Pass      Refer to Note
     15.247(d)     Band Edge Measurement                    Pass      Refer to Note
     15.247(d)     Antenna Port Emission                    Pass      Meet the requirement of limit.
    15.247(a)(2)   6dB bandwidth                            Pass      Meet the requirement of limit.
      15.247(b)    Conducted power                          Pass      Meet the requirement of limit.
      15.247(e)    Power Spectral Density                   Pass      Meet the requirement of limit.
       15.203      Antenna Requirement                      Pass      No antenna connector is used.
Note: For radiated emissions and Band Edge Measurement test was recorded in
     Report No.: RF151228C18B-5.

2.1      Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:
                                                                                      Expended Uncertainty
                    Measurement                                 Frequency
                                                                                           (k=2) (±)
         Conducted Emissions at mains ports                150kHz ~ 30MHz                   2.44 dB


2.2      Modification Record
There were no modifications required for compliance.




Report No.: RF151228C18B-2                    Page No. 6 / 23                          Report Format Version: 6.1.1
Reference No. 160527C13


3     General Information
3.1    General Description of EUT

 Product                     Communication Module
 Brand                       MURATA
 Test Model                  1DX
 Status of EUT                Engineering sample
 Power Supply Rating          3.6Vdc VBAT and 3.3Vdc VDDIO
 Modulation Type             GFSK
 Transfer Rate                1Mbps
 Operating Frequency          2402 ~ 2480MHz
 Number of Channel           40
 Channel Spacing             2MHz
 Output Power                7.379mW
 Antenna Type                 Monopole antenna with 1.4dBi gain
 Antenna Connector           NA
 Accessory Device            NA
 Data Cable Supplied         NA
Note:
1. This report is issued as a supplementary report of BV ADT report no. RF151228C18-2.
2. This report is prepared for FCC class II permissive change. The differences compared with original report
   is declaring the antenna gain from average value 0.6dBi to peak value 1.4dBi and the antenna design is
   identical. Therefore, conducted emission was re-tested and original data kept unchanged.
3. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF151228C18B-2                    Page No. 7 / 23                        Report Format Version: 6.1.1
Reference No. 160527C13


3.2   Description of Test Modes

40 channels are provided to this EUT:
  Channel      Freq. (MHz)   Channel    Freq. (MHz)      Channel   Freq. (MHz)   Channel      Freq. (MHz)
      0            2402         10         2422               20      2442         30             2462
      1            2404         11         2424               21      2444         31             2464
      2            2406         12         2426               22      2446         32             2466
      3            2408         13         2428               23      2448         33             2468
      4            2410         14         2430               24      2450         34             2470
      5            2412         15         2432               25      2452         35             2472
      6            2414         16         2434               26      2454         36             2474
      7            2416         17         2436               27      2456         37             2476
      8            2418         18         2438               28      2458         38             2478
      9            2420         19         2440               29      2460         39             2480




Report No.: RF151228C18B-2                  Page No. 8 / 23                       Report Format Version: 6.1.1
Reference No. 160527C13


3.2.1        Test Mode Applicability and Tested Channel Detail

    EUT                                APPLICABLE TO
 CONFIGURE                                                                                     DESCRIPTION
   MODE                        PLC                         APCM

         -                      √                              √               -
Where         PLC: Power Line Conducted Emission           APCM: Antenna Port Conducted Measurement

NOTE: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane.


Power Line Conducted Emission Test:

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
        EUT
 CONFIGUURE          AVAILABLE CHANNEL             TESTED CHANNEL            MODULATION TYPE            DATA RATE (Mbps)
    MODE
         -                  0 to 39                       19                       GFSK                          1



Antenna Port Conducted Measurement:

        This item includes all test value of each mode, but only includes spectrum plot of worst value of each
        mode.
        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
        EUT
 CONFIGUURE          AVAILABLE CHANNEL             TESTED CHANNEL            MODULATION TYPE            DATA RATE (Mbps)
    MODE
         -                  0 to 39                    0, 19, 39                   GFSK                          1



Test Condition:

 APPLICABLE TO           ENVIRONMENTAL CONDITIONS                  INPUT POWER (SYSTEM)                  TESTED BY
         PLC                    28deg. C, 68%RH                         120Vac, 60Hz                       Alan Wu
        APCM                    25deg. C, 60%RH                         120Vac, 60Hz                       Leo Tsai




Report No.: RF151228C18B-2                            Page No. 9 / 23                               Report Format Version: 6.1.1
Reference No. 160527C13


3.3      Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.

 ID           Product            Brand           Model No.             Serial No.              FCC ID                  Remarks
 A.        Power Supply        Topward             6603D                   700637                   NA         -
 B.          Jig board         MURATA           P2ML4452-1                      1~                  NA         Provided by manufacturer
Note:
1.    All power cords of the above support units are non-shielded (1.8m).
2.    Item A was placed under the test table.


                                                                     Shielding
 ID           Descriptions               Qty.       Length (m)                       Cores (Qty.)                  Remarks
                                                                     (Yes/No)
 1.     DC power cable                    4              1                  -             0         Provided by manufacturer
 2.     DC power cable                    4             1.8                 -             0         -




3.3.1      Configuration of System under Test


                                                  Power supply (A)



                                                                 (1)+(2)




                                                    Jig board (B)

                                                           EUT

                                                (Power from power supply)




             *Test table




3.4      General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.247)
KDB 558074 D01 DTS Meas Guidance v03r05
ANSI C63.10-2013

All test items have been performed and recorded as per the above standards.



Report No.: RF151228C18B-2                                 Page No. 10 / 23                                  Report Format Version: 6.1.1
Reference No. 160527C13


4       Test Types and Results
4.1     Conducted Emission Measurement
4.1.1    Limits of Conducted Emission Measurement

                                                            Conducted Limit (dBuV)
        Frequency (MHz)
                                               Quasi-peak                               Average
          0.15 - 0.5                             66 - 56                                 56 - 46
          0.50 - 5.0                                 56                                    46
          5.0 - 30.0                                 60                                    50
Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


4.1.2    Test Instruments

Tested date: Jun. 07, 2016
                                                                             Date of               Due Date of
     Description & Manufacturer       Model No.           Serial No.
                                                                            Calibration            Calibration
Test Receiver
                                    ESCI                   100424         Oct. 12, 2015           Oct. 11, 2016
ROHDE & SCHWARZ
RF signal cable (with 10dB PAD)
                                    5D-FB             Cable-cond2-01      Dec. 26, 2015          Dec. 25, 2016
Woken
LISN
ROHDE & SCHWARZ                    ESH2-Z5                 100100         Jan. 11, 2016           Jan. 10, 2017
(EUT)
LISN
ROHDE & SCHWARZ                    ESH3-Z5                 100312          Jul. 21, 2015          Jul. 20, 2016
(Peripheral)
Software                        BV ADT_Cond_
                                                              NA                NA                      NA
ADT                                V7.3.7.3

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 2.
      3. The VCCI Site Registration No. is C-2047.


4.1.3    Test Procedures

a.    The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
      connected to the power mains through a line impedance stabilization network (LISN). Other support units
      were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH of
      coupling impedance for the measuring instrument.
b.    Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.    The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit - 20dB) was not
      recorded.
Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP)
       and average detection (AV) at frequency 0.15MHz-30MHz.




Report No.: RF151228C18B-2                     Page No. 11 / 23                           Report Format Version: 6.1.1
Reference No. 160527C13


4.1.4   Deviation from Test Standard

No deviation.


4.1.5   Test Setup
                                  Vertical Ground
                                  Reference Plane                                Test Receiver


                                  EUT
                      40cm




                                                        80cm
                      LISN



                                                                   Horizontal Ground
                                                                    Reference Plane

                       Note: 1.Support units were connected to second LISN.




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF151228C18B-2                      Page No. 12 / 23                           Report Format Version: 6.1.1
Reference No. 160527C13


                                                                                                                                  IEDGent
                                                                                                                                   ons




4.1.7   Test Results


Phase                              Line (L)                            Detector Function              gy:z;]:ea(ngp) /


           Freg            Corr.        Reading Value             Emission Level                  Limit                     Margin
 No                       Factor              [dB (uV)]              [dB (uV)]               [dB (uV)]                        (dB)
           [MHz]            (dB)        QP.          AV.          Q.P.        AV.          QP.         AV.             QP.          AV.
  1       0.18516          10.15        6.72        —0.92        16.87       9.23         64.25       54.25           —47.38      —45.02
  2       0.20859          10.16        7.44        —1.50        17.60       8.66         63.26       53.26           —45.66      —44.60
  3       0.29844          10.17        11.30       —1.66        21.47       8.51         60.29       50.29           —38.81      —41.77
  4       0.36094          10.18        10.36       —0.40        20.54       9.78         58.71       48.71           —38.16      —38.92
  5       0.77891          10.21        9.38        —2.86        19.59       7.35         56.00       46.00           —36.41      —38.65
  6       2.50391          10.30        0.28        —3.82        10.58       6.48         56.00       46.00           —45.42      —39.52

REMARKS:
               1.   Q.P. and AV. are abbreviations of quasi—peak and average individually.
               2.   The emission levels of other frequencies were very low against the limit.
               3.   Margin value = Emission level — Limit value
               4.   Correction factor = Insertion loss + Cable loss
               5.   Emission Level = Correction Factor + Reading Value.

                          dBuy
                          10
                                                                                      PK Trace     .A
                          100                                                         GP Limit     .ms
                                                                                      CAV Limit    e
                           90

                           20

                           70

                           so

                           5o

                           40

                           30

                           20




                                                                                      1                   1
                                                                                    10.00             30 00
                                                                                                          MHz




Report No.: RF151228C18B—2                                Page No. 13 / 23                                      Report Format Version: 6.1.1
Reference No. 160527C13


                                                                                                                                IEDGent
                                                                                                                                 ons




Phase                              Neutral (N)                      Detector Function               g\l,j:z;]:ea(\/gQP) 1


           Freg            Corr.        Reading Value          Emission Level                   Limit                     Margin
 No                       Factor           [dB (uV)]              [dB (uV)]                [dB (uV)]                        (dB)
           [MHz]           (dB)          QP.       AV.         QP.         AV.           QP.         AV.             QP.          AV.
  1       0.15391         10.13          8.94     6.14        19.07       16.27         65.79       55.79           —46.71      —39.51
  2       0.26328         10.17          9.96     6.16        20.13       16.33         61.33       §1.33           —41.20      —35.00
  3       0.34141         10.18         10.02     6.28        20.20       16.46         5917        49.17           —38.97      —32.71
  4       0.36484         10.18          9.60     6.38        19.78       16.56         58.62       48.62           —38.83      —32.05
  5       0.73984         10.20         12.72     6.12        22.92       16.32         56.00       46.00           —33.08      —29.68
  6       3.17969         10.35          6.86     5.82        17.21       16.17         56.00       46.00           —38.79      —29.83

REMARKS:
               1.   Q.P. and AV. are abbreviations of quasi—peak and average individually.
               2.   The emission levels of other frequencies were very low against the limit.
               3.   Margin value = Emission level — Limit value
               4.   Correction factor = Insertion loss + Cable loss
               5.   Emission Level = Correction Factor + Reading Value.

                          dBuy
                          110
                                                                                    PK Trace     ~~
                          100                                                       QP Limit     ~~
                                                                                    CAV Limit    .
                           90

                           #0

                           70

                           5o

                           50

                           40

                           30

                           20




                                                                                    i                   1
                                                                                  10.00             30.00
                                                                                                        MHe




Report No.: RF151228C18B—2                             Page No. 14 / 23                                       Report Format Version: 6.1.1
Reference No. 160527C13


4.2     6dB Bandwidth Measurement
4.2.1    Limits of 6dB Bandwidth Measurement

The minimum of 6dB Bandwidth Measurement is 0.5 MHz.

4.2.2    Test Setup


                                                           Spectrum
           EUT
                                    Attenuator             Analyzer


4.2.3    Test Instruments

Tested date: Jan. 07, 2016
        TDescription &                                                                          Due Date of
                                Model No.               Serial No.    Date of Calibration
         Manufacturer                                                                           Calibration
Spectrum Analyzer
                                  FSP40                   100269        Mar. 30, 2015          Mar. 29, 2016
ROHDE & SCHWARZ
High Speed Peak Power
                                ML2495A                  0824011        Jul. 09, 2015          Jul. 08, 2016
Meter
Power Sensor                    MA2411B                  0738171        Jul. 09, 2015          Jul. 08, 2016
NOTE: The calibration interval of the above test instruments is 12 months and the calibrations are traceable
      to NML/ROC and NIST/USA.


4.2.4    Test Procedure

a.    Set resolution bandwidth (RBW) = 100kHz
b.    Set the video bandwidth (VBW) ≥ 3 x RBW, Detector = Peak.
c.    Trace mode = max hold.
d.    Sweep = auto couple.
e.    Measure the maximum width of the emission that is constrained by the frequencies associated with the
      two amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level
      measured in the fundamental emission


4.2.5    Deviation fromTest Standard

No deviation.

4.2.6    EUT Operating Conditions

The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.




Report No.: RF151228C18B-2                       Page No. 15 / 23                       Report Format Version: 6.1.1
Reference No. 160527C13


4.2.7    Test Result

                                            6dB Bandwidth        Minimum Limit
        Channel          Frequency (MHz)                                                 Pass / Fail
                                                (MHz)                (MHz)
          0                   2402             0.73558                0.5                   Pass
          19                  2440              0.73229               0.5                   Pass
          39                  2480              0.72951               0.5                   Pass

                                      Spectrum Plot of Worst Value




Report No.: RF151228C18B-2                  Page No. 16 / 23                     Report Format Version: 6.1.1
Reference No. 160527C13


4.3     Conducted Output Power Measurement
4.3.1        Limits of Conducted Output Power Measurement

For systems using digital modulation in the 2400–2483.5 MHz bands: 1 Watt (30dBm)

4.3.2        Test Setup



             EUT                            Power Sensor                  Power Meter
                             Attenuator




4.3.3        Test Instruments

Refer to section 4.2.3 to get information of above instrument.

4.3.4        Test Procedures

A peak power sensor was used on the output port of the EUT. A power meter was used to read the response
of the peak power sensor. Record the power level.


4.3.5        Deviation from Test Standard

No deviation.


4.3.6        EUT Operating Conditions

Same as Item 4.1.6.


4.3.7        Test Results

  Channel          Frequency (MHz) Peak Power (mW) Peak Power (dBm)             Limit (dBm)          Pass/Fail
        0                 2402              6.457                  8.10             30                 Pass
        19                2440              7.379                  8.68             30                 Pass
        39                2480              7.178                  8.56             30                 Pass




Report No.: RF151228C18B-2                      Page No. 17 / 23                        Report Format Version: 6.1.1
Reference No. 160527C13


4.4     Power Spectral Density Measurement
4.4.1    Limits of Power Spectral Density Measurement

The Maximum of Power Spectral Density Measurement is 8dBm.

4.4.2    Test Setup


                                                             Spectrum
             EUT
                                       Attenuator            Analyzer


4.4.3    Test Instruments

Refer to section 4.2.3 to get information of above instrument.


4.4.4    Test Procedure

 a. Set analyzer center frequency to DTS channel center frequency.
 b. Set the span to 1.5 times the DTS bandwidth.
 c. Set the RBW to: 3 kHz ≤ RBW ≤ 100 kHz.
 d. Set the VBW ≥ 3 × RBW.
 e. Detector = peak.
 f. Sweep time = auto couple.
 g. Trace mode = max hold.
 h. Allow trace to fully stabilize.
 i. Use the peak marker function to determine the maximum amplitude level within the RBW.


4.4.5    Deviation from Test Standard

No deviation.

4.4.6    EUT Operating Condition

Same as Item 4.1.6




Report No.: RF151228C18B-2                      Page No. 18 / 23                  Report Format Version: 6.1.1
Reference No. 160527C13


4.4.7     Test Results

                              Freq.              PSD                  Limit            Pass
        Channel
                             (MHz)              (dBm)                (dBm)             /Fail
          0                   2402              -5.96                   8              Pass
          19                 2440               -5.70                  8               Pass
          39                 2480               -5.91                  8               Pass

                                      Spectrum Plot of Worst Value




Report No.: RF151228C18B-2                  Page No. 19 / 23                  Report Format Version: 6.1.1
Reference No. 160527C13


4.5     Conducted Out of Band Emission Measurement
4.5.1    Limits of Conducted Out of Band Emission Measurement

Below 20dB of the highest emission level of operating band (in 100kHz Resolution Bandwidth).

4.5.2    Test Setup


                                                                  Spectrum
                 EUT
                                         Attenuator               Analyzer


4.5.3    Test Instruments

Refer to section 4.2.3 to get information of above instrument.


4.5.4    Test Procedure

MEASUREMENT PROCEDURE REF

a.    Set the RBW = 100 kHz.
b.    Set the VBW ≥ 300 kHz.
c.    Detector = peak.
d.    Sweep time = auto couple.
e.    Trace mode = max hold.
f.    Allow trace to fully stabilize.
g.    Use the peak marker function to determine the maximum power level in any 100 kHz band segment
      within the fundamental EBW.


MEASUREMENT PROCEDURE OOBE

a.    Set RBW = 100 kHz.
b.    Set VBW ≥ 300 kHz.
c.    Detector = peak.
d.    Sweep = auto couple.
e.    Trace Mode = max hold.
f.    Allow trace to fully stabilize.
g.    Use the peak marker function to determine the maximum amplitude level.


4.5.5    Deviation from Test Standard

No deviation.


4.5.6    EUT Operating Condition

Same as Item 4.1.6



Report No.: RF151228C18B-2                     Page No. 20 / 23                    Report Format Version: 6.1.1
Reference No. 160527C13


4.5.7   Test Results
                                           CH 0




                                          CH 19




                                          CH 39




                    CH 0 Band edge                      CH 39 Band edge




Report No.: RF151228C18B-2           Page No. 21 / 23             Report Format Version: 6.1.1
Reference No. 160527C13


5     Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF151228C18B-2                     Page No. 22 / 23   Report Format Version: 6.1.1
Reference No. 160527C13


Appendix – Information on the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                      Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF151228C18B-2                    Page No. 23 / 23                      Report Format Version: 6.1.1
Reference No. 160527C13



Document Created: 2019-10-10 04:37:20
Document Modified: 2019-10-10 04:37:20

© 2024 FCC.report