FCC Test Report_DTS

FCC ID: VPYLB1AD

Test Report

Download: PDF
FCCID_3117952

                                                                                    Test report No.        : 11354882H—A
                                                                                    Page                   : 1 of 12
                                                                                    Issued date            : August 17, 2016
                                                                                    FCC ID                 : VPYLBIAD




                                   RADIO TEST REPORT
                                     Test Report No. : 11354882H—A

       Applicant                                         Murata Manufacturing Co., Ltd.

       Type of Equipment                                 Communication Module

        Model No.                                        TypelAD

        FCC ID                                           VPYLBIAD

        Test regulation                                  FCC Part 15 Subpart C: 2016
                                                         (Class II permissive change)
                                                         *Maximum Peak Output Power Test only

        Test Result                                      Complied

                       This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
          m p o y po




                       The results in this report apply only to the sample tested.
                       This sample tested is in compliance with the above regulation.
                       The test results in this report are traceable to the national or international standards.
                       This test report must not be used by the customer to claim product certification, approval, or
                       endorsement by NVLAP, NIST, or any agency of the Federal Government.
                       This test report covers Radio technical requirements. It does not cover administrative issues
          J




                       such as Manual or non—Radio test related Requirements. (if applicable)

                               Date of test:                            July 11, 2016
                               Representative test
                               engineer:                        Ken Fespbte
                                                                         Ken Fujit#"
                                                                        Engineer
                                                              Consumer Technology Division


                               Approved by:
                                                                    Fakayuki Shimada
                                                                       Engineer
                                                              Consumer Technology Division

                                                               This laboratory is accredited by the NVLAP LAB CODE



  mviA
                                                     ®         200572—0, U.S.A. The tests reported herein have been
                                                               performed in accordance with its terms of accreditation.
                                                               *As for the range of Accreditation in NVLAP, you may
                                                               refer to the WEB address,
                                                               http://japan.ul.com/resources/eme_accredited/
                       TESTING
      NVLAP LAB CODE: 200572—0




UL Japan, Inc.
Ise EMC Lab.
4383—326 Asama—cho, Ise—shi, Mic—ken 516—0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                                13—EM—FO429


                                                                    Test report No.   : 11354882H-A
                                                                    Page              : 2 of 12
                                                                    Issued date       : August 17, 2016
                                                                    FCC ID            : VPYLB1AD




                                  REVISION HISTORY
                               Original Test Report No.: 11354882H-A

Revision     Test report No.         Date             Page      Contents
                                                      revised
-            11354882H-A             August 17,       -         -
(Original)                           2016




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                           Test report No.           : 11354882H-A
                                                                                           Page                      : 3 of 12
                                                                                           Issued date               : August 17, 2016
                                                                                           FCC ID                    : VPYLB1AD


CONTENTS                                                                                                                          PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................7
SECTION 5: Antenna Terminal Conducted Tests ................................................................................9
APPENDIX 1: Test data ........................................................................................................................10
    Maximum Peak Output Power .......................................................................................................... 10
    Average Output Power ...................................................................................................................... 11
APPENDIX 2: Test instruments ...........................................................................................................12




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.      : 11354882H-A
                                                                       Page                 : 4 of 12
                                                                       Issued date          : August 17, 2016
                                                                       FCC ID               : VPYLB1AD



SECTION 1: Customer information
Company Name                          :     Murata Manufacturing Co., Ltd.
Address                               :     10-1, Higashikotari 1-chome, Nagaokakyo-shi, Kyoto 617-8555 Japan
Telephone Number                      :     +81-75-955-6736
Facsimile Number                      :     +81-75-955-6634
Contact Person                        :     Motoo Hayashi



SECTION 2: Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                     :     Communication Module
Model No.                             :     Type1AD
Serial No.                            :     Refer to Section 4, Clause 4.2
Rating                                :     DC 3.3V
Receipt Date of Sample                :     July 5, 2016
Country of Mass-production            :     Japan, China
Condition of EUT                      :     Engineering prototype
                                            (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                   :     No Modification by the test lab


2.2       Product Description

General Specification

Clock frequency(ies) in the system    :     37.4MHz


Specification of WLAN (IEEE802.11b/g/n)
          Type of radio              Wireless LAN (IEEE802.11b/g)          Wireless LAN (IEEE802.11n)
                                                                            2.4G Band SISO (20M Band)
 Equipment Type                                                 Transceiver
 Frequency of Operation                                     2412MHz - 2462MHz
 Bandwidth & Channel spacing                                 Bandwidth : 20MHz
                                                             Ch spacing : 5MHz
 Type of Modulation                           11b: DSSS                               OFDM
                                             11g: OFDM
 Antenna Type / Antenna Gain                              Monopole Antenna: -1.8dBi
 Power Supply (inner)                                             DC 3.3V
 Operating temperature range                                 -20 to +70 deg. C

<Contents of the change from original model>
Test Report Number of original model is 10602907H-A (issued by UL Japan, Inc.).
Specification was changed from the original model as follows:
*Low power setting value of IEEE802.11b was added.
The radio specification is identical to the original.
Therefore only Maximum Peak Output Power Test was performed in this report.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                        Test report No.       : 11354882H-A
                                                                                        Page                  : 5 of 12
                                                                                        Issued date           : August 17, 2016
                                                                                        FCC ID                : VPYLB1AD



SECTION 3:               Test specification, procedures & results

3.1             Test Specification

 Test Specification                       :      FCC Part 15 Subpart C
                                                 FCC part 15 final revised on April 6, 2016.


 Title                                    :      FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                                 Section 15.207 Conducted limits
                                                 Section 15.247 Operation within the bands 902-928MHz,
                                                 2400-2483.5MHz, and 5725-5850MHz


3.2             Procedures and results

Item                   Test Procedure                      Specification               Worst margin              Results        Remarks
                       FCC: KDB 558074 D01 DTS Meas        FCC: Section
  Maximum Peak         Guidance v03r05                     15.247(b)(3)
                                                                                                See data           Complied         Conducted
  Output Power
                       IC: RSS-Gen 6.12                    IC: RSS-247 5.4(4)
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.

* In case any questions arise about test procedure, ANSI C63.10: 2013 is also referred.


FCC Part 15.31 (e)
The EUT has the power supply regulator. However one of the input voltages to RF part doesn’t go through the
regulator. The stable voltage will be supplied by the end product, which will be required to have a power supply
regulator. Therefore, the EUT complies with the requirement.

FCC Part 15.203 Antenna requirement
It is impossible for end users to replace the antenna, because it is soldered on the circuit board. Therefore, the
equipment complies with the antenna requirement of Section 15.203/212.


3.3             Addition to standard

Item                           Test Procedure       Specification             Worst margin         Results          Remarks
99% Occupied                   IC: RSS-Gen 6.6      IC: -                     N/A                  -                Conducted
Bandwidth
Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4             Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.
 Ise EM C Lab.
                                                    Antenna terminal test Uncertainty (+/-)
                 Power meter                   Conducted emission and Power density                Conducted emission
       Below               Above              Below           1 GHz            3 GHz            18 GHz         26.5 GHz    Channel power
       1 GHz               1 GHz              1 GHz          -3 GHz           -18 GHz         -26.5 GHz        -40 GHz
       0.9 dB              1.0 dB             1.4 dB          1.7 dB           2.8 dB            2.8 dB          2.9 dB           2.6 dB




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                           Test report No.         : 11354882H-A
                                                                           Page                    : 6 of 12
                                                                           Issued date             : August 17, 2016
                                                                           FCC ID                  : VPYLB1AD


3.5         Test Location

UL Japan, Inc. Ise EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
                                                                                                                Maximum
                     IC Registration Width x Depth x    Size of reference ground plane (m)
Test site                                                                                  Other rooms          measuremen
                     Number          Height (m)         / horizontal conducting plane
                                                                                                                t distance
No.1 semi-anechoic                                                                           No.1 Power
                     2973C-1        19.2 x 11.2 x 7.7   7.0 x 6.0                                               10 m
chamber                                                                                      source room
No.2 semi-anechoic
                     2973C-2        7.5 x 5.8 x 5.2     4.0 x 4.0                            -                  3m
chamber
No.3 semi-anechoic                                                                           No.3 Preparation
                     2973C-3        12.0 x 8.5 x 5.9    6.8 x 5.75                                              3m
chamber                                                                                      room
No.3 shielded room   -              4.0 x 6.0 x 2.7     N/A                                  -                  -
No.4 semi-anechoic                                                                           No.4 Preparation
                     2973C-4        12.0 x 8.5 x 5.9    6.8 x 5.75                                              3m
chamber                                                                                      room
No.4 shielded room   -              4.0 x 6.0 x 2.7     N/A                                  -                  -
No.5 semi-anechoic
                     -              6.0 x 6.0 x 3.9     6.0 x 6.0                            -                  -
chamber
No.6 shielded room   -              4.0 x 4.5 x 2.7     4.0 x 4.5                            -                  -
No.6 measurement
                     -              4.75 x 5.4 x 3.0    4.75 x 4.15                          -                  -
room
No.7 shielded room   -              4.7 x 7.5 x 2.7     4.7 x 7.5                            -                  -
No.8 measurement
                     -              3.1 x 5.0 x 2.7     N/A                                  -                  -
room
No.9 measurement
                     -              8.8 x 4.6 x 2.8     2.4 x 2.4                            -                  -
room
No.11 measurement
                     -              6.2 x 4.7 x 3.0     4.8 x 4.6                            -                  -
room



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.     : 11354882H-A
                                                                        Page                : 7 of 12
                                                                        Issued date         : August 17, 2016
                                                                        FCC ID              : VPYLB1AD



SECTION 4: Operation of E.U.T. during testing

4.1        Operating Mode(s)

Test operating mode was determined as follows according to “Section 1 of 6 802.11 a/b/g/n testing - Managing
Complex Regulatory Approvals - ” of TCB Council Workshop October 2009.

Mode                                                  Remarks*
IEEE 802.11b (11b)                                    11Mbps, PN9
*The worst condition was determined based on the test result of Maximum Peak Output Power (Mid
Channel)
*Power of the EUT was set by the software as follows;
Power settings:      11b: 13dBm
Software: version 5.90.230.2
*This setting of software is the worst case.
Any conditions under the normal use do not exceed the condition of setting.

*The details of Operating mode(s)
Test Item                                Operating Mode                       Tested frequency
Maximum Peak Output Power,               11b Tx                               2412MHz
                                                                              2437MHz
                                                                              2462MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.    : 11354882H-A
                                                                              Page               : 8 of 12
                                                                              Issued date        : August 17, 2016
                                                                              FCC ID             : VPYLB1AD


4.2       Configuration and peripherals




                            A         1        B       2
                                                                            DC 3.3V

                                                   3

                                               C


                                                   4
                                                       5
                                               D                    AC 100V/60Hz



* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT
 No.            Item               Model number                Serial number              Manufacturer               Remarks
                                                           1                        Murata Manufacturing Co.,
 A     Communication Module       Type1AD                                                                        EUT
                                                                                    Ltd.
                                                           -                        Murata Manufacturing Co.,
 B     Jig                        -                                                                              -
                                                                                    Ltd.
 C     Laptop PC                  FMV-C8230                R7305017                 FUJITSU                      -
 D     AC Adapter                 FMV-AC312                CA1007-0930              FUJITSU                      -

List of cables used
 No.             Name                     Length (m)                          Shield                        Remarks
                                                                    Cable            Connector
 1     Flat Cable                0.1                           Unshielded         Unshielded         -
 2     DC Cable                  3.0                           Unshielded         Unshielded         -
 3     USB Cable                 2.0                           Shielded           Shielded           -
 4     DC Cable                  1.8                           Unshielded         Unshielded         -
 5     AC Cable                  2.0                           Unshielded         Unshielded         -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.       : 11354882H-A
                                                                         Page                  : 9 of 12
                                                                         Issued date           : August 17, 2016
                                                                         FCC ID                : VPYLB1AD



SECTION 5: Antenna Terminal Conducted Tests
Test Procedure

The tests were made with below setting connected to the antenna port.

Test                 Span                RBW          VBW        Sweep     Detector        Trace           Instrument used
                                                                 time
Maximum Peak         -                   -            -          Auto      Peak/           -               Power Meter
Output Power                                                               Average *1)                     (Sensor: 50 MHz BW)
*1) Reference data


The test results and limit are rounded off to two decimals place, so some differences might be observed.

Test data                      : APPENDIX
Test result                    : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.        : 11354882H-A
                                                                              Page                   : 10 of 12
                                                                              Issued date            : August 17, 2016
                                                                              FCC ID                 : VPYLB1AD



APPENDIX 1: Test data

                                            Maximum Peak Output Power

                       Test place                  Ise EMC Lab. No.3 Measurement Room
                       Report No.                  11354882H
                       Date                        07/11/2016
                       Temperature/ Humidity       23 deg. C / 40% RH
                       Engineer                    Ken Fujita
                       Mode                        11b Tx


               Freq.     Reading    Cable      Atten.       Result               Limit          Margin
                                    Loss
              [MHz]       [dBm]     [dB]        [dB]    [dBm]    [mW]      [dBm]      [mW]       [dB]
               2412        5.63     1.77       10.03    17.43    55.32     30.00      1000      12.57
               2437        5.99     1.78       10.03    17.80    60.19     30.00      1000      12.20
               2462        5.72     1.79       10.03    17.53    56.64     30.00      1000      12.47

             Sample Calculation:
             Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator


             2437MHz
               Rate  Reading Remark

              [Mbps] [dBm]
                 1       8.42
                 2       8.73
                5.5      8.63
                11       9.02   *
             *: Worst Rate
             All comparizon were carried out on same frequency and measurement factors.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                             Test report No.        : 11354882H-A
                                                                             Page                   : 11 of 12
                                                                             Issued date            : August 17, 2016
                                                                             FCC ID                 : VPYLB1AD


                                               Average Output Power

                    Test place                   Ise EMC Lab. No.3 Measurement Room
                    Report No.                   11354882H
                    Date                         07/11/2016
                    Temperature/ Humidity        23 deg. C / 40% RH
                    Engineer                     Ken Fujita
                    Mode                         11b Tx

                 [AV]
                 11b       11Mbps
                   Freq.    Reading    Cable     Atten.         Result               Limit         Margin
                                       Loss
                  [MHz]     [dBm]      [dB]       [dB]     [dBm]     [mW]      [dBm]      [mW]       [dB]
                   2412      1.83      1.77      10.03     13.63     23.06     30.00      1000      16.37
                   2437      1.96      1.78      10.03     13.77     23.80     30.00      1000      16.23
                   2462      1.97      1.79      10.03     13.78     23.89     30.00      1000      16.22

                 Sample Calculation:
                 Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                      Test report No.        : 11354882H-A
                                                                      Page                   : 12 of 12
                                                                      Issued date            : August 17, 2016
                                                                      FCC ID                 : VPYLB1AD



APPENDIX 2: Test instruments

Test equipment
  Control No.        Instrument         Manufacturer       Model No      Serial No       Test Item   Calibration Date *
                                                                                                      Interval(month)
   MOS-19       Thermo-Hygrometer   Custom             CTH-201          0001            AT           2015/12/08 * 12
   MSA-15       Spectrum Analyzer   Agilent            E4440A           MY46187105      AT           2015/11/11 * 12
   MPM-12       Power Meter         Anritsu            ML2495A          0825002         AT           2016/06/06 * 12
   MPSE-17      Power sensor        Anritsu            MA2411B          0738285         AT           2016/06/06 * 12
   MTW-09       Torque wrench       HUBER+SUHNER       74 Z-0-0-21      72676           AT           2015/03/05 * 36
   MAT-22       Attenuator(10dB)    Orient Microwave   BX10-0476-00     -               AT           2016/03/18 * 12
                1-18GHz
   MCC-138      Microwave cable     HUBER+SUHNER       SUCOFLEX 102     37953/2         AT           2015/10/08 * 12
   MMM-10       DIGITAL HiTESTER    Hioki              3805             051201148       AT           2016/01/18 * 12


The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test Item:           AT: Antenna Terminal Conducted test


                                                  End of Report




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2016-08-23 09:18:35
Document Modified: 2016-08-23 09:18:35

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC