Test set up photographs

FCC ID: VNP-ME1500

Test Setup Photos

Download: PDF
FCCID_4276505

                                                                                                          CSA Confidential




                            FCC ID: VNP-ME1500                  IC: 11986A-ME1500

5 TEST CONDITIONS AND RESULTS

 5.1     AC power line conducted emissions


Remarks:             Not applicable as the EUT is battery powered and has no AC mains connections.




 5.2     Field strength of fundamental

For test instruments and accessories used see section 6 Part CPR 3.

5.2.1    Description of the test location

Test location:                Anechoic chamber 1
Test distance:                3m

5.2.2    Photo documentation of the test set-up




CSA Group Bayern GmbH                                                      File No. T42255-03-00KS, page 12 of 33
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                 Rev. No. 5.1, 2018-11-19


                                                                                                      CSA Confidential




                            FCC ID: VNP-ME1500               IC: 11986A-ME1500

 5.3     Out-of-band emission, radiated

For test instruments and accessories used see section 6 Part SER1, SER 2, SER 3.

5.3.1    Description of the test location

Test location:                OATS 1
Test location:                Anechoic chamber 1

Test distance:                3m

5.3.2    Photo documentation of the test set-up

Test setup 9 kHz – 30 MHz:




CSA Group Bayern GmbH                                                   File No. T42255-03-00KS, page 14 of 33
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                             Rev. No. 5.1, 2018-11-19


                                                                                        CSA Confidential




                            FCC ID: VNP-ME1500     IC: 11986A-ME1500

Test setup 30 MHz – 1000 MHz:




Test setup 1 GHz – 18 GHz:




CSA Group Bayern GmbH                                     File No. T42255-03-00KS, page 15 of 33
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                               Rev. No. 5.1, 2018-11-19


                                                                                                           CSA Confidential




                            FCC ID: VNP-ME1500                 IC: 11986A-ME1500


Test setup 18 GHz – 25 GHz:




5.3.3    Applicable standard

According to FCC Part 15C, Section 15.249 (d):
Emission radiated outside of the specified frequency bands, except harmonics, shall be attenuated by at least 50 dB
below the level of the fundamental or to the general radiated limit in FCC Part 15C, Section 15.209, whichever is the
lesser attenuation.

5.3.4    Description of Measurement

The radiated emissions from the EUT are measured in the frequency range of 9 kHz to 1000 MHz using a tuned
receiver and appropriate broadband linearly polarized antennas. The setup of the EUT and the measurement
procedure is in accordance to ANSI C63.10, Item 6.3. In the frequency range above 1 GHz a spectrum analyser is
used with appropriate linear polarized antennas. If the emission level in peak mode complies with the average limit
testing is stopped and peak values will be reported, otherwise, the emission is measured in average mode again and
reported. The EUT is measured in TX continuous mode modulated under normal conditions.

Instrument settings:
9 kHz – 150 kHz                       RBW:         200 Hz
150 kHz - 30 MHz                      RBW:         9 kHz
30 MHz – 1000 MHz:                    RBW:         120 kHz
1000 MHz – 25 GHz                     RBW:         1 MHz




CSA Group Bayern GmbH                                                      File No. T42255-03-00KS, page 16 of 33
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                  Rev. No. 5.1, 2018-11-19


                                                                                                             CSA Confidential




                            FCC ID: VNP-ME1500                   IC: 11986A-ME1500


 5.4     EBW and OBW

For test instruments and accessories used see section 6 Part MB.

5.4.1    Description of the test location

Test location:                Anechoic chamber 1

5.4.2    Photo documentation of the test set-up




5.4.3    Applicable standard

According to FCC Part 15, Section 15.215(c):
Intentional radiators operating under the alternative provisions to the general emission limits, as contained in Section
15.217 through Section 15.257, must be designed to ensure that the 20 dB bandwidth of the emission is contained
within the frequency band designated in the rule section under which the equipment is operated.

5.4.4    Description of Measurement

The bandwidth is measured at an amplitude level reduced from the reference level by a specified ratio of -20 dB
(99%). The x-dB-down (OBW) function of the analyser is used. The measurement is performed with normal
modulation in TX continuous mode.

Spectrum analyser settings:
RBW: 30 kHz,      VBW: 100 kHz,              Span: 3 MHz,   Trace mode: max. hold,          Detector: max. peak;




CSA Group Bayern GmbH                                                        File No. T42255-03-00KS, page 24 of 33
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                    Rev. No. 5.1, 2018-11-19


                                                                                                          CSA Confidential




                            FCC ID: VNP-ME1500                IC: 11986A-ME1500

 5.5     Correction for pulse operation (duty cycle)

For test instruments and accessories used see section 6 Part DC.

5.5.1    Description of the test location

Test location:                AREA4

5.5.2    Photo documentation of the test set-up




5.5.3    Applicable standard

According to FCC Part 15A, Section 15.35(c):
When the radiated emission limits are expressed in terms of average value and pulsed operation is employed, the
measurement field strength shall be determined by averaging over one complete puls train, including blanking
intervals, as long as the pulse train does not exceed 0.1s. In cases where the puls train exceeds 0.1s, the measured
field strength shall be determined from the average absolute voltage during a 0.1s interval during which the field
strength is at its maximum. The exact method of calculating the average field strength shall be submitted.




CSA Group Bayern GmbH                                                     File No. T42255-03-00KS, page 30 of 33
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                 Rev. No. 5.1, 2018-11-19



Document Created: 2019-03-12 10:25:59