RF Exposure info(BU)

FCC ID: VLJ-MBP34BU

RF Exposure Info

Download: PDF
FCCID_1922063

Report No.: 60.870.12.040.01F




5.0       RF Exposure Compliance Requirement

          Test Requirement:                    FCC part 15 section 15.247 (i)
          Test Method:                         FCC part 15 section 1.1307 (b1)
                                               OET Bulletin 65, Edition 01-01


Results: PASS

Systems operation under the provision of this section shall be operated in a manner that
ensures the public is not exposed to radio frequency energy levels in excess of the
Commission’s guideline,

The EUT is considered as a mobile device according to OET Bulletin 65, Edition 01-01,
therefore distance to human body of min. 20cm is determined.

Frequency Band:                 2.410.875 GHz ~2.471.625GHz

                                    Portable (< 20cm separation )
Device Category:                    Mobile ( >20cm separation )
                                    Others :

                                    Occupational/ Controlled exposure
Exposure Classification:
                                    General Population / Uncontrolled exposure
Max. Output Power               31.70mW
Antenna Gain                    0 dBi ( Numeric gain:1)
                                    MPE Evaluation
Evaluation Applied:
                                    SAR Evaluation

MPE calculation:

The radiated ( EIRP) = 31.70 mW

The power density at 20cm from the antenna : = EIRP / 4 R²
                                             = 0.0063mW / cm²



Limits for General Population/Uncontrolled Exposure [OET Bulletin 65, Edition 01-01]:


      Frequency        Electric Field      Magnetic Field        Power Density       Averaging Time
        Range          Strength (E)        Strength (H)              (S)              |E|2, |H|2 or S
        (MHz)             (V/m)                (A/m)               (mW/cm2)             (minutes)

    0.3-1.34                614                  1.63                (100)*                 30
    1.34-30                824/f                2.19/f              (180/f2)*               30
    30-300                 27.5                 0.073                  0.2                  30
   300-1500                  --                   --                 f/1500                 30
 1500-100,000                --                   --                   1.0                  30