Report

FCC ID: VLJ-MBP15BU

Test Report

Download: PDF
FCCID_1175130

                                Binatone Electronics International Limited

                                                           Application
                                                               For
                                                           Certification

                   2.4GHz Frequency Hopping Spread Spectrum Baby Unit

                                              (FCC ID: VLJ-MBP15BU)




HK09051500-1
MN/ sl
September 09, 2009


-   The test report only allows to be revised within the retention period unless further standard or the requirement was noticed.
-   This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
    Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
    party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
    report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the
    Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in
    writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does
    not imply that the material, product, or service is or has ever been under an Intertek certification program.



                                           Intertek Testing Services Hong Kong Ltd.
                                       2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                              Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com


                         INTERTEK TESTING SERVICES


                    MEASUREMENT/TECHNICAL REPORT

     Binatone Electronics International Limited – MODEL: MBP15BU
                                                         MBP15
                                                         MBP15-2

                              FCC ID: VLJ-MBP15BU


      This report concerns (check one)   Original Grant    X          Class II Change

      Equipment Type: DSS-Part 15 Spread Spectrum Transmitter


      Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes                    No X

                                                          If yes, defer until :
                                                                                   date
      Company Name agrees to notify the Commission by:
                                                               date

      of the intended date of announcement of the product so that the grant can be
      issued on that date.


      Transition Rules Request per 15.37?          Yes                    No X

      If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR
      [10-01-08 Edition] provision.


      Report prepared by:                   Nip Ming Fung, Melvin
                                            Intertek Testing Services Hong Kong Ltd.
                                            2/F., Garment Centre,
                                            576 Castle Peak Road,
                                            Kowloon, Hong Kong.
                                            Phone: 852-2173-8535
                                            Fax: 852-2741-1693




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                               Page 1 of 32


                                    INTERTEK TESTING SERVICES


                                                Table of Contents

1.0 Summary of Test................................................................................................. 4

2.0 General Description ............................................................................................ 6
  2.1 Product Description ............................................................................................ 6
  2.2 Related Submittal(s) Grants ............................................................................... 6
  2.3 Test Methodology............................................................................................... 7
  2.4 Test Facility........................................................................................................ 7

3.0 System Test Configuration ................................................................................. 9
  3.1 Justification ........................................................................................................ 9
  3.2 EUT Exercising Software.................................................................................... 9
  3.3 Special Accessories ......................................................................................... 10
  3.4 Measurement Uncertainty ................................................................................ 10
  3.5 Equipment Modification .................................................................................... 10

4.0 Measurement Results ....................................................................................... 12
  4.1 Maximum Conducted Output Power at Antenna Terminals ............................... 12
  4.2 Maximum 20 dB RF Bandwidth ........................................................................ 13
  4.3 Minimum Number of Hopping Frequencies....................................................... 14
  4.4 Minimum Hopping Channel Carrier Frequency Separation................................ 15
  4.5 Average Channel Occupancy Time .................................................................. 16
  4.6 Out of Band Conducted Emission..................................................................... 17
  4.7 Transmitter Radiated Emissions in Restricted Bands ........................................ 18
  4.8 Radiated Spurious Emissions........................................................................... 19
  4.9 Field Strength Calculation................................................................................. 20
  4.10 Radiated Emission Configuration Photograph – Baby Unit .............................. 21
  4.11 Radiated Emission Data – Baby Unit .............................................................. 22
  4.12 AC Line Conducted Emission ......................................................................... 27
  4.13 AC Line Conducted Configuration Photograph – Baby Unit............................. 28
  4.14 AC Line Conducted Emission Data – Baby Unit.............................................. 29
  4.15 Transmitter Duty Cycle Calculation and Measurement.................................... 30
  4.16 Radio Frequency Radiation Exposure............................................................. 31

5.0 Equipment List .................................................................................................. 32

Appendix - Exhibits of Appendix for Certification




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                                                        Page 2 of 32


                      INTERTEK TESTING SERVICES



                           EXHIBIT 1
                    SUMMARY OF TEST RESULTS




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                               Page 3 of 32


                         INTERTEK TESTING SERVICES


1.0 Summary of Test


        Binatone Electronics International Limited - MODEL: MBP15
                                                            MBP15BU
                                                            MBP15-2

                              FCC ID: VLJ-MBP15BU

 TEST                                              REFERENCE        RESULTS

 Max. Output Power                                 15.247(b)(1)     Pass

 Min. No. of Hopping Frequencies                   15.247(a)(1)     Pass

 Min. Hopping Channel Carrier Frequency            15.247(a)(1)     Pass
 Separation
 Average Time of Occupancy                         15.247(a)(1)     Pass

 Out of Band Antenna Conducted Emission            15.247(d)        Pass

 Radiated Emission in Restricted Bands             15.247(d)        Pass

 Radiated Spurious Emissions                       15.247(d)        Pass
                                                   15.109
 AC Conducted Emission                             15.207           Pass
                                                   15.107
 Antenna Requirement                               15.203           Pass (See Notes)

 Radio Frequency Radiation Exposure                15.247(i)        Pass


Notes: The EUT uses a permanently attached antenna which, in accordance to
Section 15.203, is considered sufficient to comply with the provisions of this section.




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 4 of 32


                      INTERTEK TESTING SERVICES



                            EXHIBIT 2
                       GENERAL DESCRIPTION




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                               Page 5 of 32


                          INTERTEK TESTING SERVICES


2.0 General Description

2.1 Product Description


The Equipment Under Test (EUT) is a 2.4GHz Frequency Hopping Spread Spectrum
of Baby Unit of Baby Monitor System. It operates at 2401.056MHz to 2482.272MHz
with 95 physical channels. There are 95 channels (95 channels for Dummy, 19
channels for traffic). The EUT is powered by an 100-240VAC to 6.0VDC 300mA AC
adaptor. It has power, volume button to turn on the unit and adjust volume. Besides,
it has 4 buttons, “music”, “page”, “play or stop” and “light” for music selection, page the
corresponding receiver, play or stop the music and turn on/off the light respectively.

Antenna Type : Integral, Internal

The Model: MBP15BU and MBP15-2 are the same as the Model: MBP15 in
hardware aspect except different number of parent unit and its charger. The
difference in model number serves as marketing strategy.

The circuit description and frequency hopping algorithm are saved with filename:
descri.pdf


2.2 Related Submittal(s) Grants

This is an application for certification of a transmitter. The parent unit, associated with
this baby unit, has FCC ID: VLJ-MBP15PU and has been filed at the same time.




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                          Page 6 of 32


                         INTERTEK TESTING SERVICES

2.3 Test Methodology

Both AC mains line-conducted and radiated emission measurements were performed
according to the procedures in ANSI C63.4 (2003). Preliminary radiated scans were
performed in the Open Area Test Sites only to determine worst case modes. All
Radiated tests were performed at an antenna to EUT distance of 3 meters, unless
stated otherwise in the “Justification Section” of this Application. Antenna port
conducted measurements were performed according to FCC Public Notice DA 00-705.
All other measurements were made in accordance with the procedures in 47 CFR Part 2.


2.4 Test Facility

The open area test site and conducted measurement facility used to collect the data is
located at Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. This test
facility and site measurement data have been fully placed on file with the FCC.




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                     Page 7 of 32


                      INTERTEK TESTING SERVICES


                            EXHIBIT 3
                   SYSTEM TEST CONFIGURATION




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                               Page 8 of 32


                         INTERTEK TESTING SERVICES

3.0 System Test Configuration

3.1 Justification

For emissions testing, the equipment under test (EUT) was setup to transmit
continuously to simplify the measurement methodology. Care was taken to ensure
proper power supply voltages during testing. During testing, all cables (if any) were
manipulated to produce worst case emissions. The EUT was powered by a 100-
240VAC to 6.0VDC 300mA (Model: KSS05-060-0300U) adaptor or batteries.

For the measurements, the EUT is attached to a plastic stand if necessary and placed
on the wooden turntable. If the EUT attaches to peripherals, they are connected and
operational (as typical as possible).

The signal is maximized through rotation and placement in the three orthogonal axes.
The antenna height and polarization are varied during the search for maximum signal
level. The antenna height is varied from 1 to 4 meters. Radiated emissions are
taken at three meters unless the signal level is too low for measurement at that
distance. If necessary, a pre-amplifier is used and/or the test is conducted at a closer
distance.

Measurements of the radiated signal level of the fundamental frequency component of
the emission was performed with the supply voltage varied between 85% and 115% of
the nominal rated supply voltage.

Analyzer resolution is 100 kHz or greater for frequencies below 1000 MHz.           The
resolution is 1 MHz or greater for frequencies above 1000 MHz.

Radiated emission measurement were performed the lowest radio frequency signal
generated in the device which is greater than 9 kHz to the tenth harmonic of the highest
fundamental frequency or to 40 GHz, whichever is lower.

Determination of pulse desensitization was made according to Hewlett Packard
Application Note 150-2, Spectrum Analysis... Pulsed RF. The effective period (τeff)
referred to TX ON time plot. With the resolution bandwidth 1MHz and spectrum
analyzer IF bandwidth 3 dB, the pulse desensitization factor was 0 dB.

All relevant operation modes have been tested, and the worst-case data is included in
this report.


3.2 EUT Exercising Software

The EUT exercise program (if any) used during radiated and conducted testing was
designed to exercise the various system components in a manner similar to a typical
use.




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 9 of 32


                          INTERTEK TESTING SERVICES

3.3    Special Accessories

There are no special accessories necessary for compliance of this product.


3.4 Measurement Uncertainty

When determining of the test conclusion, the Measurement Uncertainty of test has
been considered.


3.5 Equipment Modification

Any modifications installed previous to testing by Binatone Electronics International Ltd.
will be incorporated in each production model sold/leased in the United States.

No modifications were installed by Commercial & Electrical Division, Intertek Testing
Services Hong Kong Ltd.

All the items listed under section 3.0 of this report are confirmed by:



      Confirmed by:

                  Nip Ming Fung, Melvin
                  Supervisor
                  Intertek Testing Services Hong Kong Ltd.
                  Agent for Binatone Electronics International Ltd.




                                                      Signature


                        September 09, 2009            Date




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 10 of 32


                      INTERTEK TESTING SERVICES


                             EXHIBIT 4
                       MEASUREMENT RESULTS




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                               Page 11 of 32


                           INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited     Date of Test: May 29-June 12, 2009
Model: MBP15

4.0 Measurement Results

4.1 Maximum Conducted Output Power at Antenna Terminals, FCC Rules
    15.247(b)(1):

     [ ] The antenna power of the EUT was connected to the input of a power meter.
         Power was read directly and cable loss correction was added to the reading
         to obtain power at the EUT antenna terminals.

     [×]   The antenna port of the EUT was connected to the input of a spectrum
           analyzer. The analyzer was set for RBW>20dB bandwidth and power was
           read directly in dBm.      External attenuation and cable loss were
           compensated for using the OFFSET function of the analyser.

For antennas with gains of 6 dBi or less, maximum allowed transmitter output is 1.0watt
(+30 dBm).

                             (Baby Unit) Antenna Gain = 0 dBi
      Frequency (MHz)                   Output in dBm                  Output in mWatt
Low Channel:          2401.056               20.55                          113.50
Middle Channel:       2440.800               20.36                          108.64
High Channel:         2482.272               20.10                          102.33

Cable loss : 0.5 dB     External Attenuation : 0 dB

Cable loss, external attenuation: [ x ] included in OFFSET function
                                  [ ] added to SA raw reading
dBm max. output level = 20.55 dBm (21dBm or less)

Please refer to the attached plots for details:

Plot B1A: Low Channel Output Power
Plot B1B: Middle Channel Output Power
Plot B1C: High Channel Output Power

For electronic filing, the above plots are saved with filename: maxop.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                         Page 12 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.2 Maximum 20 dB RF Bandwidth, FCC Rule 15.247(a)(1)(iii):

The antenna port of the EUT was connected to the input of a spectrum analyzer.
Analyzer RES BW was chosen so that the display was a result of the hopping channel
modulation. For each RF output channel investigated, the spectrum analyzer center
frequency was set to the channel carrier. A PEAK output reading was taken, a
DISPLAY line was drawn 20 dB lower than PEAK level. The 20 dB bandwidth was
determined from where the channel output spectrum intersected the display line.


                                      (Baby Unit)
             Frequency (MHz)                           20 dB Bandwidth (kHz)
          2440.800 and 2482.272                                  618

Refer to the following plots for 20 dB bandwidth:

Plot B2A: Low Channel 20 dB RF Bandwidth
Plot B2B: Middle Channel 20 dB RF Bandwidth
Plot B2C: High Channel 20 dB RF Bandwidth

For electronic filing, the above plots are saved with filename: 20dB.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                        Page 13 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.3 Minimum Number of Hopping Frequencies, FCC Rule 15.247(a)(1)(iii):

The RF passband of the EUT was divided into 5 equal bands. With the analyzer set to
MAX HOLD readings were taken for 2-3 minutes in each band. The channel peaks so
recorded were added together, and the total number compared to the minimum number
of channels required in the regulation.


                                       Baby Unit
No. of hopping channels                                          95



Minimum Requirements: at least 15 hopping channels for 2400MHz-2483.5MHz.

For electronic filing, the above plots are saved with filename: chno.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                        Page 14 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.4 Minimum Hopping Channel Carrier Frequency Separation, FCC Ref: 15.247(a)(1):

Using the DELTA MARKER function of the analyzer, the frequency separation between
two adjacent channels was measured and compared against the limit.

[   ] 25 kHz

[ x ] 20 dB bandwidth of hopping channel: 618kHz

[ ] 2/3 of 20dB bandwidth of hopping channel:


                                        Baby Unit
Channel Separation                                              868kHz

Plot B4: Channel 46 and Channel 47

Requirement: The frequency separation is more than 20dB bandwidth of hopping
channel.

For electronic filing, the above plots are saved with filename: fsepa.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                         Page 15 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.5 Average Channel Occupancy Time, FCC Ref: 15.247(a)(1)(iii):

The spectrum analyzer center frequency was set to one of the known hopping
channels. The SWEEP was set to 10ms, the SPAN was set to ZERO SPAN, and the
TRIGGER was set to VIDEO. The time duration of the transmission so captured was
measured with the MARKER DELTA function.

The SWEEP was then set to the time required by the regulation (20 seconds for 902-
928 MHz devices, if the 20dB bandwidth is less than 250kHz, 10 seconds for 902-928
MHz if the 20dB bandwidth is or greater than 250kHz, “0.4 seconds x Number of
hopping channels employed” seconds for 2400-2483.5 MHz, 30 seconds for 5725-
5850 MHz). The analyzer was set to SINGLE SWEEP, the total ON time was added
and compared against the limit (0.4 seconds).

Dummy Bearer: Average 0.4 seconds maximum occupancy in 38 seconds (0.4sec. x
95) for 2400MHz-2483.5MHz.

                                       Baby Unit
Average Occupancy Time = 0.25 x 40                                 10.0 ms



Traffic Bearer: Average 0.4 seconds maximum occupancy in 7.6 seconds (0.4sec. x
19) for 2400MHz-2483.5MHz.

                   Baby Unit (worst-case: 2 Parent Units operation)
Average Occupancy Time = [(0.822ms x 2) + 0.25] x 40               75.76 ms

Refer to attached spectrum analyzer plots B5A-D.

For electronic filing, the above plots are saved with filename: avetime.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                           Page 16 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.6 Out of Band Conducted Emissions, FCC Rule 15.247(d):

In any 100 kHz bandwidth outside the EUT passband, the RF power produced by the
modulation products of the spreading sequence, the information sequence, and the
carrier frequency shall be at least 20 dB below that of the maximum in-band 100 kHz
emission, or else shall meet the general limits for radiated emissions at frequencies
outside the passband, whichever results in lower attenuation.

All other types of emissions from the EUT shall meet the general limits for radiated
frequencies outside the passband.

Refer to the following plots for out of band conducted emissions data:

Plot B6A1 - B6A2: Low Channel Emissions
Plot B6B1 - B6B2: Middle Channel Emissions
Plot B6C1 - B6C2: High Channel Emissions
Plot B6D2: Modulation Products Emissions*

All spurious emission and up to the tenth harmonic was measured and they were found
to be at least 20 dB below the highest level of the desired power in the passband.

Furthermore, delta measurement technique for measuring bandedge emissions was
incorporated in the test of the edge at 2483.5MHz.

*This plot is shown the worst-case which has been already considered between enable
and disable the hopping function of the EUT.

For electronic filing, the above plots are saved with filenames: obantcon.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 17 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.7 Transmitter Radiated Emissions in Restricted Bands, FCC Rule 15.35(b), (c):

Data is included of the worst case configuration (the configuration which resulted in the
highest emission levels). A sample calculation, configuration photographs and data
tables of the emissions are included. All measurements were performed with peak
detection unless otherwise specified.

The data on the following pages list the significant emission frequencies, the limit and
the margin of compliance.




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 18 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.8 Radiated Spurious Emissions, FCC Ref: 15.247(d), 15.109

[ × ] Not required – No digital part

[ x ] Test results are attached

[ x ] Included in the separated DoC report.




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 19 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.9 Field Strength Calculation

       The field strength is calculated by adding the reading on the Spectrum Analyzer
       to the factors associated with preamplifiers (if any), antennas, cables, pulse
       desensitization and average factors (when specified limit is in average and
       measurements are made with peak detectors). A sample calculation is
       included below.

       FS = RA + AF + CF - AG + PD + AV

       where         FS = Field Strength in dBµV/m
                     RA = Receiver Amplitude (including preamplifier) in dBµV
                     CF = Cable Attenuation Factor in dB
                     AF = Antenna Factor in dB
                     AG = Amplifier Gain in dB
                     PD = Pulse Desensitization in dB
                     AV = Average Factor in -dB

       In the radiated emission table which follows, the reading shown on the data
       table may reflect the preamplifier gain. An example of the calculations, where
       the reading does not reflect the preamplifier gain, follows:

       FS = RA + AF + CF - AG + PD + AV

       Example
       Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4
       dB and cable factor of 1.6 dB is added. The amplifier gain of 29 dB is
       subtracted. The pulse desensitization factor of the spectrum analyzer was 0
       dB, and the resultant average factor was -10 dB. The net field strength for
       comparison to the appropriate emission limit is 32 dBµV/m. This value in
       dBµV/m was converted to its corresponding level in µV/m.

       RA = 62.0 dBµV
       AF = 7.4 dB
       CF = 1.6 dB
       AG = 29.0 dB
       PD = 0 dB
       AV = -10 dB
       FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32 dBµV/m

     Level in µV/m = Common Antilogarithm [(32 dBµV/m)/20] = 39.8 µV/m




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 20 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.10 Radiated Emission Configuration Photograph - Baby Unit


                    Worst Case Restricted Band Radiated Emission
                                          at

                           7322.400 MHz and 7446.816MHz

     For electronic filing, the worst case radiated emission configuration photographs
     are saved with filename: config photos.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 21 of 32


                             INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited      Date of Test: May 29-June 12, 2009
Model: MBP15

4.11 Radiated Emission Data - Baby Unit

The data on the following pages list the significant emission frequencies, the limit and
the margin of compliance.


           Judgement : Passed by 9.8 dB margin compared with peak limit


******************************************************



TEST PERSONNEL:




Tester Signature



Koo Wai Ip, Engineer
Typed/Printed Name


September 09, 2009
Date




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                         Page 22 of 32


                           INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited    Date of Test: May 29-June 12, 2009
Model: MBP15
Mode : TX-Channel 0


                                    Table 1, Baby Unit

                               Radiated Emissions
                 Pursuant to FCC 15.247(d) Emissions Requirement

                          Pre-Amp Antenna Average Calculated   Average
Polari- Frequency Reading   Gain   Factor  Factor   at 3m    Limit at 3m         Margin
zation     (MHz)   (dBµV)   (dB)    (dB)    (dB)  (dBμV/m)    (dBμV/m)            (dB)
  V      *4802.112  56.5     33     34.9    34.4     24.0       54.0             -30.0
  V     *12005.280  52.9     33     40.5    34.4     26.0       54.0              -28.0

                                  Pre-Amp   Antenna     Net at    Peak Limit
 Polari-   F requency   Reading     Gain     Factor   3m - Peak     at 3m       Margin
 zation       (MHz)     (dBµV)      (dB)      (dB)    (dBµV/m )   (dBµV /m )     (dB)
   V        *4802.112    56.5        33       34.9      58.4        74.0        -15.6
   V       *12005.280    52.9        33       40.5      60.4        74.0        -13.6

NOTES: 1. Peak detector is used for the emission measurement.

            2. All measurements were made at 3 meters. Harmonic emissions not
               detected at the 3-meter distance were measured at 0.3-meter and an
               inverse proportional extrapolation was performed to compare the signal
               level to the 3-meter limit. No other harmonic emissions than those
               reported were detected at a test distance of 0.3-meter.

            3. Negative value in the margin column shows emission below limit.

            4. Horn antenna used for the emission over 1000MHz.

            * Emission within the restricted band meets the requirement of part 15.205.
              The corresponding limit as per 15.209 is based on Quasi peak limit for
              frequencies below 1000 MHz and average limit for frequencies over
              1000 MHz.


Test Engineer: Koo Wai Ip




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 23 of 32


                           INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited    Date of Test: May 29-June 12, 2009
Model: MBP15
Mode : TX-Channel 46


                                    Table 2, Baby unit

                                Radiated Emissions
                  Pursuant to FCC 15.247(d) Emission Requirement

                          Pre-Amp      Antenna Average Calculated   Average
Polari- Frequency Reading   Gain        Factor  Factor   at 3m    Limit at 3m    Margin
zation     (MHz)   (dBµV)   (dB)         (dB)    (dB)  (dBµV/m)    (dBµV/m)       (dB)
  V      *4881.600  56.3     33          34.9    34.4     23.8       54.0        -30.2
  V      *7322.400  59.3     33          37.9    34.4     29.8       54.0        -24.2
  V     *12204.000  53.1     33          40.5    34.4    26.2        54.0        -27.8

                                  Pre-Amp   Antenna     Net at    Peak Limit
 Polari-   F requency   Reading     Gain     Factor   3m - Peak     at 3m       Margin
 zation       (MHz)     (dBµV)      (dB)      (dB)    (dBµV/m )   (dBµV /m )     (dB)
   V        *4881.600    56.3        33       34.9      58.2         74.0       -15.8
   V        *7322.400    59.3        33       37.9      64.2         74.0        -9.8
   V       *12204.000    53.1        33       40.5      60.6         74.0       -13.4

NOTES: 1. Peak detector is used for the emission measurement.

            2. All measurements were made at 3 meters. Harmonic emissions not
               detected at the 3-meter distance were measured at 0.3-meter and an
               inverse proportional extrapolation was performed to compare the signal
               level to the 3-meter limit. No other harmonic emissions than those
               reported were detected at a test distance of 0.3-meter.

            3. Negative value in the margin column shows emission below limit.

            4. Horn antenna used for the emission over 1000MHz.

            * Emission within the restricted band meets the requirement of part 15.205.
              The corresponding limit as per 15.209 is based on Quasi peak limit for
              frequencies below 1000 MHz and average limit for frequencies over
              1000 MHz.


Test Engineer: Koo Wai Ip




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 24 of 32


                           INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited    Date of Test: May 29-June 12, 2009
Model: MBP15
Mode : TX-Channel 94


                                    Table 3, Baby unit

                               Radiated Emissions
                 Pursuant to FCC 15.247(d) Emissions Requirement

                           Pre-Amp Antenna Average Calculated   Average
 Polari- Frequency Reading   Gain   Factor  Factor   at 3m    Limit  at 3m       Margin
 zation     (MHz)   (dBμV)   (dB)    (dB)    (dB)  (dBµV/m)    (dBµV/m)           (dB)
   H      2482.272   122.0    33     29.4    34.4     84.0          --              --
   V      *4964.544  56.5     33     34.9    34.4     24.0       54.0            -30.0
   V      *7446.816  59.3     33     37.9    34.4     29.8       54.0            -24.2
   V     *12411.360  53.0     33     40.5    34.4     26.1       54.0            -27.9
   H     19858.176    -4.8    33     37.8    34.4    -34.4       54.0            -88.4



                                  Pre-Amp   Antenna     Net at    Peak Limit
 Polari-   F requency   Reading     Gain     Factor   3m - Peak     at 3m       Margin
 zation       (MHz)     (dBµV)      (dB)      (dB)    (dBµV/m )   (dBµV /m )     (dB)
   H        2482.272     122.0       33       29.4      118.4         --           --
   V        *4964.544    56.5        33       34.9       58.4       74.0        -15.6
   V        *7446.816    59.3        33       37.9       64.2       74.0         -9.8
   V       *12411.360    53.0        33       40.5       60.5       74.0        -13.5

NOTES: 1. Peak detector is used for the emission measurement.

            2. All measurements were made at 3 meters. Harmonic emissions not
               detected at the 3-meter distance were measured at 0.3-meter and an
               inverse proportional extrapolation was performed to compare the signal
               level to the 3-meter limit. No other harmonic emissions than those
               reported were detected at a test distance of 0.3-meter.

            3. Negative value in the margin column shows emission below limit.

            4. Horn antenna used for the emission over 1000MHz.

            * Emission within the restricted band meets the requirement of part 15.205.
              The corresponding limit as per 15.209 is based on Quasi peak limit for
              frequencies below 1000 MHz and average limit for frequencies over
              1000 MHz.


Test Engineer: Koo Wai Ip




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 25 of 32


                           INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15
Mode: Talk



                                   Table 4, Baby Unit

                              Radiated Emissions
           Pursuant to FCC 15.247(d) and 15.109 Emission Requirement

                                       Pre- Antenna    Net     Limit
                 Frequency   Reading   amp Factor     at 3m    at 3m           Margin
 Polarization       (MHz)    (dB µV)   (dB)  (dB)   (dBµV/m) (dBµV/m)           (dB)
      V             55.300    39.2      16   11.0      34.2    40.0             -5.8
      V           *110.600    32.4      16   14.0      30.4    43.5            -13.1
      H           *165.900    30.6      16   17.0      31.6    43.5            -11.9
      H            221.200    31.4      16   17.0      32.4    46.0            -13.6
      H           *276.500    25.4      16   22.0      31.4    46.0            -14.6
      H           *331.800    22.5      16   24.0      30.5    46.0            -15.5

NOTES: 1. Quasi-peak detector is used for the emission below or equal to 1000 MHz.

          2. All measurements were made at 3 meters. Harmonic emissions not
             detected at the 3-meter distance were measured at 0.3-meter and an
             inverse proportional extrapolation was performed to compare the signal
             level to the 3-meter limit. No other harmonic emissions than those
             reported were detected at a test distance of 0.3-meter.

          3. Negative value in the margin column shows emission below limit.

          *     Emission within the restricted band meets the requirement of part
                15.205. The corresponding limit as per 15.209 is based on Quasi peak
                limit for frequencies below 1000 MHz and average limit for frequencies
                over 1000 MHz.



Test Engineer: Koo Wai Ip




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 26 of 32


                           INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.12 AC Line Conducted Emission, FCC Rule 15.207:

[ ] Not required; battery operation only

[×]   Test data attached




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 27 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.13 AC Line Conducted Configuration Photograph – Baby Unit

                      Worst Case Line-Conducted Configuration
                                        at

                                      4.596 MHz




     For electronic filing, the worst case line conducted configuration photographs are
     saved with filename: config photos.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 28 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.14 AC Line Conducted Emission Data – Baby Unit

The data on the following pages list the significant emission frequencies, the limit, and
the margin of compliance.


     Judgement : Passed by 19.84 dB margin compared with quasi-peak limit


For electronic filing, the worst case line conducted emission data are saved with
filename: conduct.pdf



TEST PERSONNEL:




Tester Signature


Koo Wai Ip, Engineer
Typed/Printed Name


September 09, 2009
Date




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 29 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.15 Transmitter Duty Cycle Calculation and Measurements, FCC Rule 15.35(b), (c)

The EUT antenna output port was connected to the input of the spectrum analyzer.
The analyzer center frequency was set to EUT RF channel carrier. The SWEP
function on the analyzer was set to ZERO SPAN. The transmitter ON time was
determined from the resultant time-amplitude display:

Baby Unit:

Duty cycle (DC) = Maximum ON time in 100ms/100ms
               = (0.822ms x 2) + 0.25ms/100ms for 2 Parent Units operation

Duty cycle correction, dB = 20* log (DC)
                          = 20* log (0.0189)
                          = -34.4dB


X    See attached spectrum analyzer chart (s) for transmitter timing
     Baby Unit: Plot B7, D7
     See transmitter timing diagram provided by manufacturer

     Not applicable, duty cycle was not used.


For electronic filing, the above plots are saved with filenames: dcc.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                        Page 30 of 32


                          INTERTEK TESTING SERVICES

Company: Binatone Electronics International Limited   Date of Test: May 29-June 12, 2009
Model: MBP15

4.16 Radio Frequency Radiation Exposure, FCC Rule 15.247(i):

EUT is subject to the radio frequency exposure requirements specified in FCC Rule §§
1.1307. It shall be considered to operate in a “general population / uncontrolled”
environment.


[×]   Output power is greater than the applicable low threshold from TCB Exclusions
      List (17 July 2002). EUT was evaluated for Specific Absorption Rate (SAR)
      evaluation compliance according to OET Bulletin 65 Supplement C (Edition 01-
      01) and SAR Measurement Requirements for 3-6GHz (October 2006, Revised).
      It is in compliance with the SAR evaluation requirements. The caution
      statement specified in the user manual.

[×]   EUT was evaluated for Maximum Permissible Exposure (MPE) evaluation
      compliance according to OET Bulletin 65, Supplement C (Edition 01-01). The
      evaluation calculation results are saved as filename: RF exposure.pdf




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                      Page 31 of 32


                          INTERTEK TESTING SERVICES

5.0 Equipment List

1) Radiated Emissions Test

 Equipment              Biconical Antenna   Log Periodic Antenna    Double Ridged Guide
                                                                          Antenna
 Registration No.          EW-0954               EW-0446                 EW-1015
 Manufacturer               EMCO                   EMCO                    EMCO
 Model No.                  3104C                   3146                    3115
 Calibration Date        Sep. 30, 2008          Oct. 02, 2008          Jul. 28, 2008
 Calibration Due Date    Mar. 30, 2010          Apr. 02, 2010          Jan. 28, 2010

 Equipment                 Digital         EMI Test        Spectrum     Broad-Band Horn
                         Multimeter        Receiver         Analyzer        Antenna
 Registration No.         EW-1237         EW-0016           EW-2188         EW-1679
 Manufacturer              FLUKE              R&S        AGILENTTECH SCHWARZBECK
 Model No.                   179           ESVS30           E4407B         BBHA9170
 Calibration Date       Sep. 01, 2008    Apr. 14, 2009    Dec. 18, 2008   Feb. 10, 2009
 Calibration Due Date   Oct. 01, 2009    Apr. 14, 2010    Dec. 18, 2009   Feb. 10, 2010

2) Conducted Emissions Test

 Equipment               EMI Test Receiver          Pulse Limiter        Artificial Mains
 Registration No.            EW-2251                  EW-0698               EW-0192
 Manufacturer                  R&S                      R&S                    R&S
 Model No.                     ESCI                   ESH3-Z2               ESH3-Z5
 Calibration Date          Oct. 28, 2008            Feb. 03, 2009        Nov. 12, 2008
 Calibration Due Date      Oct. 28, 2009            Feb. 03, 2010        Nov. 12, 2009

3) Conductive Measurement Test

 Equipment                Spectrum Analyzer
 Registration No.             EW-1792
 Manufacturer                    R&S
 Model No.                     FSP40
 Calibration Date           Feb. 02, 2009
 Calibration Due Date       Feb. 02, 2010




Test Report Number: HK09051500-1
FCC ID: VLJ-MBP15BU                                                       Page 32 of 32



Document Created: 2009-09-25 12:35:20
Document Modified: 2009-09-25 12:35:20