RF Exposure Report

FCC ID: VLEPL-1710L

RF Exposure Info

Download: PDF
FCCID_3464669

                    Test Report No.: FS170525N025-3


                                    RF EXPOSURE REPORT
   Applicant                        Asian Express Holdings Limited


   Address                          RM1702, Sino Centre, 582-592 Nathan Road, Mongkok, Kowloon, Hong Kong.


   Manufacturer or
                                    Asian Express Holdings Limited
   Supplier

   Address                          RM1702, Sino Centre, 582-592 Nathan Road, Mongkok, Kowloon, Hong Kong.

   Product                          Sky Rider with camera/air pressure sensor/Wifi

   Additional Name                  Cloud Rider 2.0 /Graviton+Streaming

   Brand Name                       PROPEL

   Model                            PL-1710

                                    PL-1711, PL-1712, PL-1713, PL-1714, PL-1715, PL-1716, PL-1717, PL-1718,
   Additional Model &
                                    PL-1719, PL-1720, PL-1721, PL-1722, PL-1723, PL-1724, PL-1725, PL-1726,
   Model Difference
                                    PL-1727, PL-1728, PL-1729, KH-2142
   Date of tests                    May 26, 2017 ~ Jul. 04, 2017

        FCC Part 2 (Section 2.1091)
        KDB 447498 D01
        IEEE C95.1

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                       Tested by Breeze Jiang                                                            Approved by Glyn He
                 Project Engineer / EMC Department                                                    Supervisor / EMC Department




                                                                                                              Date: Jul. 07, 2017
   This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
   permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
   set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
   identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
   information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
   negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
   within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
   report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
   non-compliance to the specification


                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                           Page 1 of 6                                                               Report Version 1


                Test Report No.: FS170525N025-3




                                    TABLE OF CONTENTS


   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FS170525N025-3



                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FS170525N025-3           Original release                                                         Jul. 05, 2017




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                 Test Report No.: FS170525N025-3


   1. CERTIFICATION


                            FCC ID: VLEPL-1710L

                       PRODUCT: Sky Rider with camera/air pressure sensor/Wifi

       ADDITIONAL NAME:                Cloud Rider 2.0 /Graviton+Streaming

                 BRAND NAME: PROPEL

                     MODEL NO.: PL-1710

                              PL-1711, PL-1712, PL-1713, PL-1714, PL-1715,
                              PL-1716, PL-1717, PL-1718, PL-1719, PL-1720,
              ADDITIONAL NO.:
                              PL-1721, PL-1722, PL-1723, PL-1724, PL-1725,
                              PL-1726, PL-1727, PL-1728, PL-1729, KH-2142

                 TEST SAMPLE: Engineering Sample

                     APPLICANT: Asian Express Holdings Limited

                   STANDARDS: FCC Part 2 (Section 2.1091)

                                       KDB 447498 D01

                                       IEEE C95.1

   Note:
           Additional models (see above table) are identical with the test model PL-1710 except the color of
           the model number for trading purpose.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 4 of 6                                                    Report Version 1


                Test Report No.: FS170525N025-3


   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm2)                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm


   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 6                                                      Report Version 1


    B U R E A U
    V E R I TA S    Test Report No.: FS170525N025—3


   5. ANTENNA GAIN
         The antennas provided to the EUT, please refer to the following table:
                   T ran_sml.tter
                            i                    Peak Gain (dBi)                        A ntenna
                      Circuit                                                             Type
                      Chain 0                          2.0                        Integral Antenna



   6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER
   The tuned conducted Average Power (declared by client)

                                          Target         Tolerance             hovie!              Upper Tolerance
                    Mode                  Power            (dBm)             Tolerance              PP (dBm)
                                          (dBm)                                (dBm)
                   802.11b                  13                 +—2                 11                        15

                   802.11g                  11                 +—2                 9                         13

            802.11n({HT20)                  11                 +—2                 9                         13


   The measured conducted Average Power
                                                     Frequency                               Averaged Power
                    Mode                                (MHz)                                       (dBm)
                   802.11b                              2462                                        13.25

                   802.11g                              2412                                         11.91

            802.11n({HT20)                              2412                                         11.02



      FREQUENCY              |MAX AVERAGE]|         ANTENNA                                    POWER
        BAND                    POWER                 GAIN              DIS(-:;‘:‘;CE          DENSITY               (mblvl\/né;z)
            (MHz)                   (dBm)              (dBi)                                  (mW/cm*)
        2412—2462                    15                 2.0                  20                 0.00997                    1.0




    ——— END ———




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                            Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                            Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com

                                                               Page 6 of 6                                                   Report Version 1



Document Created: 2017-07-07 18:37:45
Document Modified: 2017-07-07 18:37:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC