Radio Test Report

FCC ID: VIYHRM5087

Test Report

Download: PDF
FCCID_3391036

                                                                           Test report No.       : 11701947H-A
                                                                           Page                  : 1 of 21
                                                                           Issued date           : April 12, 2017
                                                                           FCC ID                : VIYHRM5087




                            RADIO TEST REPORT
                              Test Report No. : 11701947H-A
        Applicant                          :    Hosiden Corporation

        Type of Equipment                  :    Sensor Beacon

        Model No.                          :    TMX-CB10

        FCC ID                             :    VIYHRM5087

        Test regulation                    :    FCC Part 15 Subpart C: 2016
                                                *Antenna Terminal Conducted Tests only

        Test Result                        :    Complied
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           6.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)

                        Date of test:                        February 16, 2017

                        Representative test
                        engineer:
                                                             Yuta Moriya
                                                               Engineer
                                                      Consumer Technology Division


                        Approved by:
                                                           Takayuki Shimada
                                                               Engineer
                                                      Consumer Technology Division

                                                       This laboratory is accredited by the NVLAP LAB CODE
                                                       200572-0, U.S.A. The tests reported herein have been
                                                       performed in accordance with its terms of accreditation.
                                                       *As for the range of Accreditation in NVLAP, you may
                                                       refer to the WEB address,
                                                       http://japan.ul.com/resources/emc_accredited/

      NVLAP LAB CODE: 200572-0




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                      13-EM-F0429


                                                                    Test report No.   : 11701947H-A
                                                                    Page              : 2 of 21
                                                                    Issued date       : April 12, 2017
                                                                    FCC ID            : VIYHRM5087




                                  REVISION HISTORY
                               Original Test Report No.: 11701947H-A

Revision     Test report No.         Date             Page      Contents
                                                      revised
-            11701947H-A             April 12, 2017   -         -
(Original)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                               Test report No.            : 11701947H-A
                                                                                               Page                       : 3 of 21
                                                                                               Issued date                : April 12, 2017
                                                                                               FCC ID                     : VIYHRM5087


CONTENTS                                                                                                                                PAGE

SECTION 1: Customer information.......................................................................................................4
SECTION 2: Equipment under test (E.U.T.) .........................................................................................4
SECTION 3: Test specification, procedures & results..........................................................................5
SECTION 4: Operation of E.U.T. during testing ..................................................................................7
SECTION 5: Antenna Terminal Conducted Tests ................................................................................9
APPENDIX 1: Test data ........................................................................................................................10
    6dB Bandwidth ................................................................................................................................. 10
    Maximum Peak Output Power .......................................................................................................... 12
    Average Output Power ...................................................................................................................... 13
    Conducted Spurious Emission .......................................................................................................... 15
    Power Density ................................................................................................................................... 18
    99%Occupied Bandwidth ................................................................................................................. 20
APPENDIX 2: Test instruments ...........................................................................................................21




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.      : 11701947H-A
                                                                       Page                 : 4 of 21
                                                                       Issued date          : April 12, 2017
                                                                       FCC ID               : VIYHRM5087



SECTION 1: Customer information
Company Name                         :      Hosiden Corporation
Address                              :      4-33, Kitakyuhoji1chome, Yao-city, Osaka, 581-0071
Telephone Number                     :      +81-72-924-1153
Facsimile Number                     :      +81-72-996-4672
Contact Person                       :      Tomoki Umeda


SECTION 2: Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                    :      Sensor Beacon
Model No.                            :      TMX-CB10
Serial No.                           :      Refer to Section 4, Clause 4.2
Rating                               :      ACC12V: Typ: DC 14.4 V (DC 10.8 V - 15.1 V)
                                            ACC24V: Typ: DC 28.0 V (DC 21.0 V - 30.0 V)
Receipt Date of Sample               :      February 16, 2017
Country of Mass-production           :      China
Condition of EUT                     :      Production prototype
                                            (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                  :      No Modification by the test lab

2.2       Product Description

Model: TMX-CB10 (referred to as the EUT in this report) is a Sensor Beacon.


General Specification

Clock frequency(ies) in the system   :      Main: 32 MHz, Sub: 32.768 kHz

Radio Specification

Bluetooth Low Energy
Radio Type                           :      Transmitter
Frequency of Operation               :      2402 MHz - 2480 MHz
Modulation                           :      GFSK
Power Supply (radio part input)      :      DC 1.29 V
Antenna type                         :      λ/4 inverted-Fantenna
Antenna Gain                         :      0.5 dBi




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                    Test report No.   : 11701947H-A
                                                                                    Page              : 5 of 21
                                                                                    Issued date       : April 12, 2017
                                                                                    FCC ID            : VIYHRM5087



SECTION 3:            Test specification, procedures & results

3.1        Test Specification

 Test Specification                    :    FCC Part 15 Subpart C
                                            FCC Part 15 final revised on November 14, 2016 and effective December 14,
                                            2016

 Title                                 :    FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                            Section 15.207 Conducted limits
                                            Section 15.247 Operation within the bands 902-928MHz,
                                            2400-2483.5MHz, and 5725-5850MHz


3.2        Procedures and results

Item                Test Procedure                     Specification            Worst margin             Results         Remarks
                    FCC: KDB 558074 D01 DTS Meas       FCC: Section
                    Guidance v03r05                    15.247(a)(2)
  6dB Bandwidth                                                                                           Complied          Conducted
                    IC: -                              IC: RSS-247 5.2(a)
                    FCC: KDB 558074 D01 DTS Meas       FCC: Section
  Maximum Peak      Guidance v03r05                    15.247(b)(3)
                                                                                See data.                 Complied          Conducted
  Output Power
                    IC: RSS-Gen 6.12                   IC: RSS-247 5.4(d)
                    FCC: KDB 558074 D01 DTS Meas       FCC: Section 15.247(e)
                    Guidance v03r05
   Power Density                                                                                          Complied          Conducted
                    IC: -                              IC: RSS-247 5.2(b)
                      FCC: KDB 558074 D01 DTS Meas     FCC: Section15.247(d)
 Spurious Emission Guidance v03r05                                                                                          Conducted
                                                                                                          Complied
Restricted Band Edges IC: RSS-Gen 6.13                 IC: RSS-247 5.5
                                                                                -                                        (below 30 MHz)
                                                       RSS-Gen 8.9
                                                       RSS-Gen 8.10
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.


* In case any questions arise about test procedure, ANSI C63.10: 2013 is also referred.


FCC Part 15.31 (e)
The test was performed with the New Battery (DC 1.29 V) and the stable voltage was supplied to the EUT during the
tests. Therefore, the EUT complies with the requirement.

FCC Part 15.203 Antenna requirement
It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
equipment complies with the antenna requirement of Section 15.203.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                        Test report No.         : 11701947H-A
                                                                                        Page                    : 6 of 21
                                                                                        Issued date             : April 12, 2017
                                                                                        FCC ID                  : VIYHRM5087


3.3            Addition to standard
Item                          Test Procedure        Specification             Worst margin          Results             Remarks
99% Occupied                  IC: RSS-Gen 6.6       IC: -                     N/A                   -                   Conducted
Bandwidth
Other than above, no addition, exclusion nor deviation has been made from the standard.

3.4            Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.
 Ise EM C Lab.
                                                      Antenna terminal test Uncertainty (+/-)
                 Power meter                     Conducted emission and Power density                   Conducted emission
      Below                Above                Below           1 GHz            3 GHz               18 GHz         26.5 GHz         Channel power
      1 GHz                1 GHz                1 GHz          -3 GHz           -18 GHz            -26.5 GHz        -40 GHz
      0.9 dB               1.0 dB               1.4 dB          1.5 dB           2.8 dB               2.8 dB          2.9 dB            2.6 dB



3.5            Test Location

 UL Japan, Inc. Ise EM C Lab. *NVLAP Lab. code: 200572-0
 4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
 Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
                                                                                                                              M aximum
                         IC Registration   Width x Depth x       Size of reference ground plane (m) /
 Test site                                                                                                Other rooms         measurement
                         Number            Height (m)            horizontal conducting plane
                                                                                                                              distance
 No.1 semi-anechoic                                                                                       No.1 Power source
                          2973C-1           19.2 x 11.2 x 7.7     7.0 x 6.0                                                   10 m
 chamber                                                                                                  room
 No.2 semi-anechoic
                          2973C-2           7.5 x 5.8 x 5.2       4.0 x 4.0                               -                   3m
 chamber
 No.3 semi-anechoic                                                                                       No.3 Preparation
                          2973C-3           12.0 x 8.5 x 5.9      6.8 x 5.75                                                  3m
 chamber                                                                                                  room
 No.3 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                     -                   -
 No.4 semi-anechoic                                                                                       No.4 Preparation
                          2973C-4           12.0 x 8.5 x 5.9      6.8 x 5.75                                                  3m
 chamber                                                                                                  room
 No.4 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                     -                   -
 No.5 semi-anechoic
                          -                 6.0 x 6.0 x 3.9       6.0 x 6.0                               -                   -
 chamber
 No.6 shielded room       -                 4.0 x 4.5 x 2.7       4.0 x 4.5                               -                   -
 No.6 measurement
                          -                 4.75 x 5.4 x 3.0      4.75 x 4.15                             -                   -
 room
 No.7 shielded room       -                 4.7 x 7.5 x 2.7       4.7 x 7.5                               -                   -
 No.8 measurement
                          -                 3.1 x 5.0 x 2.7       N/A                                     -                   -
 room
 No.9 measurement
                          -                 8.8 x 4.6 x 2.8       2.4 x 2.4                               -                   -
 room
 No.11 measurement
                          -                 6.2 x 4.7 x 3.0       4.8 x 4.6                               -                   -
 room
 * Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0m for No.1, No.2, No.3, and No.4 semi-
 anechoic chambers and No.3 and No.4 shielded rooms.


3.6            Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.    : 11701947H-A
                                                                        Page               : 7 of 21
                                                                        Issued date        : April 12, 2017
                                                                        FCC ID             : VIYHRM5087



SECTION 4: Operation of E.U.T. during testing

4.1       Operating Mode(s)

Mode                                                     Remarks*
Bluetooth Low Energy (BT LE)                             Maximum Packet Size, PRBS9
*Power of the EUT was set by the software as follows;
Power settings:       4 dBm
Software:             HRM5087_RadioTest_NoSoftDevice_161026.hex
*This setting of software is the worst case.
Any conditions under the normal use do not exceed the condition of setting.
In addition, end users cannot change the settings of the output power of the product.


*The details of Operating mode(s)
Test Item                                     Operating Mode                 Tested frequency
Spurious Emission (Conducted),                BT LE Tx                       2402 MHz
6dB Bandwidth,                                                               2440 MHz
Maximum Peak Output Power,                                                   2480 MHz
Power Density,
99% Occupied Bandwidth




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.        : 11701947H-A
                                                                        Page                   : 8 of 21
                                                                        Issued date            : April 12, 2017
                                                                        FCC ID                 : VIYHRM5087



4.2       Configuration and peripherals



                                                           2
                             A                                                     B



                                                                               3
                                 1
                                                                                   C


                        DC 3.0 V                                               4


                                                                         AC 100 V / 60 Hz

                                                                                    : Standard Ferrite Core
* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.


Description of EUT
 No.            Item              Model number                 Serial number                Manufacturer          Remarks
       Sensor Beacon             TMX-CB10              1                                  Hosiden                 EUT
 A
                                                                                          Corporation
 B     Laptop PC                 CF-N8HWCDPS           OBKSA08702                         Panasonic               -
 C     AC Adapter                CF-AA6373B M4         6372BM409X21200B                   Panasonic               -

List of cables used
 No.             Name                  Length (m)                            Shield                               Remarks
                                                                Cable                    Connector
 1     DC Cable                  0.5                   Unshielded                  Unshielded                     -
 2     USB Cable                 1.8                   Shielded                    Shielded                       -
 3     DC Cable                  0.9                   Unshielded                  Unshielded                     -
 4     AC Cable                  0.8                   Unshielded                  Unshielded                     -




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                        Test report No.          : 11701947H-A
                                                                                        Page                     : 9 of 21
                                                                                        Issued date              : April 12, 2017
                                                                                        FCC ID                   : VIYHRM5087



SECTION 5: Antenna Terminal Conducted Tests
Test Procedure

The tests were made with below setting connected to the antenna port.

Test                   Span                      RBW             VBW           Sweep      Detector          Trace           Instrument used
                                                                               time
6dB Bandwidth          3 MHz                     100 kHz         300 kHz       Auto       Peak              Max Hold        Spectrum Analyzer
99% Occupied           Enough width to display   1 to 5 %        Three times   Auto       Peak              Max Hold        Spectrum Analyzer
Bandwidth *1)          emission skirts           of OBW            of RBW
Maximum Peak           -                         -               -             Auto       Peak/             -               Power Meter
Output Power                                                                              Average *2)                       (Sensor: 50 MHz BW)
Peak Power Density      1.5 times the             3 kHz          10 kHz         Auto      Peak                Max Hold      Spectrum Analyzer
                        6dB Bandwidth                                                                                       *3)
Conducted Spurious 9kHz to 150kHz                 200 Hz         620 Hz         Auto       Peak               Max Hold      Spectrum Analyzer
Emission *4)            150kHz to 30MHz           9.1 kHz        27 kHz
*1) Peak hold was applied as Worst-case measurement.
*2) Reference data
*3) Section 10.2 Method PKPSD (peak PSD) of "KDB 558074 D01 DTS Meas Guidance v03r05".
*4) In the frequency range below 30MHz, RBW was narrowed to separate the noise contents.
Then, wide-band noise near the limit was checked separately, however the noise was not detected as shown in the chart.
(9 kHz - 150 kHz: RBW = 200 Hz, 150 kHz - 30 MHz: RBW = 9.1 kHz)

The test results and limit are rounded off to two decimals place, so some differences might be observed.

Test data                            : APPENDIX
Test result                          : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                     Test report No.   : 11701947H-A
                                                                     Page              : 10 of 21
                                                                     Issued date       : April 12, 2017
                                                                     FCC ID            : VIYHRM5087



APPENDIX 1: Test data
                                                6dB Bandwidth

                    Test place                Ise EMC Lab. No.3 Measurement Room
                    Report No.                11701947H
                    Date                      February 16, 2017
                    Temperature / Humidity    23 deg. C / 36 % RH
                    Engineer                  Yuta Moriya
                    Mode                      Tx BT LE



                                   Mode      Frequency 6dB Bandwidth      Limit
                                               [MHz]       [MHz]          [kHz]
                                   BTLE            2402          0.726       > 500
                                                   2440          0.693       > 500
                                                   2480          0.701       > 500




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 11701947H-A
                                                                 Page              : 11 of 21
                                                                 Issued date       : April 12, 2017
                                                                 FCC ID            : VIYHRM5087


                                                6dB Bandwidth

                                                        BTLE
                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                               Test report No.        : 11701947H-A
                                                                               Page                   : 12 of 21
                                                                               Issued date            : April 12, 2017
                                                                               FCC ID                 : VIYHRM5087


                                           Maximum Peak Output Power

                     Test place                    Ise EMC Lab. No.3 Measurement Room
                     Report No.                    11701947H
                     Date                          February 16, 2017
                     Temperature / Humidity        23 deg. C / 36 % RH
                     Engineer                      Yuta Moriya
                     Mode                          Tx BT LE

             Antenna 1
              Freq.    Reading     Cable      Atten.         Result                Limit          Margin
                                   Loss        Loss
              [MHz]      [dBm]     [dB]        [dB]     [dBm]      [mW]      [dBm]         [mW]    [dB]
               2402      -6.67     1.39       10.05      4.76      2.99      30.00         1000   25.24
               2440      -6.74     1.39       10.05      4.70      2.95      30.00         1000   25.30
               2480      -6.86     1.40       10.05      4.60      2.88      30.00         1000   25.40



             Sample Calculation:
             Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss

             *The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.         : 11701947H-A
                                                                                 Page                    : 13 of 21
                                                                                 Issued date             : April 12, 2017
                                                                                 FCC ID                  : VIYHRM5087


                                          Average Output Power
                              (Reference data for RF Exposure / SAR testing)

                     Test place                    Ise EMC Lab. No.3 Measurement Room
                     Report No.                    11701947H
                     Date                          February 16, 2017
                     Temperature / Humidity        23 deg. C / 36 % RH
                     Engineer                      Yuta Moriya
                     Mode                          Tx BT LE


          Freq.    Reading    Cable      Atten.          Result          Duty            Result
                              Loss        Loss      (Time average)      factor   (Burst power average)
          [MHz]     [dBm]     [dB]        [dB]     [dBm]      [mW]       [dB]      [dBm]      [mW]
           2402     -7.07     1.39       10.05      4.36       2.73     0.23        4.59       2.88
           2440     -7.14     1.39       10.05      4.30       2.69     0.23        4.53       2.84
           2480     -7.19     1.40       10.05      4.27       2.67     0.23        4.50       2.82


        Sample Calculation:
        Result (Time average) = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss
        Result (Burst power average) = Time average + Duty factor

        *The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                             Test report No.    : 11701947H-A
                                                                             Page               : 14 of 21
                                                                             Issued date        : April 12, 2017
                                                                             FCC ID             : VIYHRM5087


                                              Burst rate confirmation

                     Test place                   Ise EMC Lab. No.3 Measurement Room
                     Report No.                   11701947H
                     Date                         February 16, 2017
                     Temperature / Humidity       23 deg. C / 36 % RH
                     Engineer                     Yuta Moriya
                     Mode                         Tx BT LE


                                                            BTLE
                                  Tx on / (Tx on + Tx off) =                   0.949
                                  Tx on / (Tx on + Tx off) * 100 =              94.9 %
                                  Duty factor = 10 * log (2.223 / 2.110) =      0.23 dB




* Since the burst rate is not different between the channels, the data has been obtained on the representative channel.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                           Test report No.            : 11701947H-A
                                                                                           Page                       : 15 of 21
                                                                                           Issued date                : April 12, 2017
                                                                                           FCC ID                     : VIYHRM5087


                                                 Conducted Spurious Emission

                         Test place                        Ise EMC Lab. No.3 Measurement Room
                         Report No.                        11701947H
                         Date                              February 16, 2017
                         Temperature / Humidity            23 deg. C / 36 % RH
                         Engineer                          Yuta Moriya
                         Mode                              Tx BT LE 2402MHz


                         9 kHz - 150 kHz                                                       150 kHz - 30 MHz




   Frequency   Reading      Cable Attenuator Antenna          N         EIRP Distance Ground               E        Limit  Margin   Remark
                            Loss         Loss      Gain*   (Number                          bounce (field strength)
     [kHz]      [dBm]       [dB]         [dB]      [dBi]  of Output) [dBm]        [m]        [dB]       [dBuV/m] [dBuV/m] [dB]
        15.23     -97.8        0.07          9.9      2.0          1     -85.9       300        6.0           -24.6   43.9   68.5
       200.00     -88.2        0.31          9.9      2.0          1     -76.0       300        6.0           -14.7   21.5   36.2
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on KDB 558074 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                           Test report No.            : 11701947H-A
                                                                                           Page                       : 16 of 21
                                                                                           Issued date                : April 12, 2017
                                                                                           FCC ID                     : VIYHRM5087


                                                 Conducted Spurious Emission

                         Test place                        Ise EMC Lab. No.3 Measurement Room
                         Report No.                        11701947H
                         Date                              February 16, 2017
                         Temperature / Humidity            23 deg. C / 36 % RH
                         Engineer                          Yuta Moriya
                         Mode                              Tx BT LE 2440MHz


                         9 kHz - 150 kHz                                                       150 kHz - 30 MHz




   Frequency   Reading      Cable Attenuator Antenna          N         EIRP Distance Ground               E        Limit  Margin   Remark
                            Loss         Loss      Gain*   (Number                          bounce (field strength)
     [kHz]      [dBm]       [dB]         [dB]      [dBi]  of Output) [dBm]        [m]        [dB]       [dBuV/m] [dBuV/m] [dB]
        15.93     -96.6        0.07          9.9      2.0          1     -84.7       300        6.0           -23.4   43.5   66.9
       374.00     -88.9        0.53          9.9      2.0          1     -76.5       300        6.0           -15.2   16.1   31.3
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on KDB 558074 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                           Test report No.            : 11701947H-A
                                                                                           Page                       : 17 of 21
                                                                                           Issued date                : April 12, 2017
                                                                                           FCC ID                     : VIYHRM5087


                                                 Conducted Spurious Emission

                         Test place                        Ise EMC Lab. No.3 Measurement Room
                         Report No.                        11701947H
                         Date                              February 16, 2017
                         Temperature / Humidity            23 deg. C / 36 % RH
                         Engineer                          Yuta Moriya
                         Mode                              Tx BT LE 2480MHz


                         9 kHz - 150 kHz                                                       150 kHz - 30 MHz




   Frequency   Reading      Cable Attenuator Antenna          N         EIRP Distance Ground               E        Limit  Margin   Remark
                            Loss         Loss      Gain*   (Number                          bounce (field strength)
     [kHz]      [dBm]       [dB]         [dB]      [dBi]  of Output) [dBm]        [m]        [dB]       [dBuV/m] [dBuV/m] [dB]
         9.35     -96.0        0.06          9.8      2.0          1     -84.1       300        6.0           -22.8   48.1   70.9
       150.00     -88.0        0.26          9.9      2.0          1     -75.9       300        6.0           -14.6   24.0   38.6
  E [dBuV/m] = EIRP [dBm] - 20 log (Distance [m]) + Ground bounce [dB] + 104.8 [dBuV/m]
  EIRP[dBm] = Reading [dBm] + Cable loss [dB] + Attenuator Loss [dB] + Antenna gain [dBi] + 10 * log (N)
  N: Number of output
  *2.0 dBi was applied to the test result based on KDB 558074 since antenna gain was less than 2.0 dBi.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.   : 11701947H-A
                                                                                   Page              : 18 of 21
                                                                                   Issued date       : April 12, 2017
                                                                                   FCC ID            : VIYHRM5087


                                                       Power Density

                      Test place                     Ise EMC Lab. No.3 Measurement Room
                      Report No.                     11701947H
                      Date                           February 16, 2017
                      Temperature / Humidity         23 deg. C / 36 % RH
                      Engineer                       Yuta Moriya
                      Mode                           Tx BT LE

    11b                     Antenna 1
            Freq.            Reading         Cable      Atten.     Result         Limit     Margin
                                             Loss        Loss
            [MHz]              [dBm]         [dB]        [dB]      [dBm]          [dBm]       [dB]
           2402.00             -18.45        1.39       10.05      -7.02           8.00      15.02
           2440.00             -19.40        1.39       10.05      -7.96           8.00      15.96
           2480.00             -20.14        1.40       10.05      -8.68           8.00      16.68

    Sample Calculation:
    Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss

    *The equipment and cables were not used for factor 0 dB of the data sheets.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                 Test report No.   : 11701947H-A
                                                                 Page              : 19 of 21
                                                                 Issued date       : April 12, 2017
                                                                 FCC ID            : VIYHRM5087


                                                 Power Density

                                                        BTLE
                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.   : 11701947H-A
                                                                       Page              : 20 of 21
                                                                       Issued date       : April 12, 2017
                                                                       FCC ID            : VIYHRM5087


                                             99%Occupied Bandwidth
                    Test place                  Ise EMC Lab. No.3 Measurement Room
                    Report No.                  11701947H
                    Date                        February 16, 2017
                    Temperature / Humidity      23 deg. C / 36 % RH
                    Engineer                    Yuta Moriya
                    Mode                        Tx BT LE

                                                        BTLE
                                                      2402 MHz




                                                      2440 MHz




                                                      2480 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                        Test report No.      : 11701947H-A
                                                                        Page                 : 21 of 21
                                                                        Issued date          : April 12, 2017
                                                                        FCC ID               : VIYHRM5087



APPENDIX 2: Test instruments

Test equipment
   Control No.         Instrument            Manufacturer      Model No          Serial No    Test Item    Calibration Date *
                                                                                                            Interval(month)
    MSA-03       Spectrum Analyzer     Agilent              E4448A            MY44020357     AT           2016/05/19 * 12
    MPM-09       Power Meter           Anritsu              ML2495A           6K00003348     AT           2016/10/17 * 12
    MPSE-12      Power sensor          Anritsu              MA2411B           011598         AT           2016/10/17 * 12
    MCC-67       Microwave Cable       Suhner               SUCOFLEX102       28635/2        AT           2016/04/18 * 12
                 1G-40GHz
    MAT-57       Attenuator(10dB)      Suhner               6810.19.A         -              AT           2016/12/15 * 12
    MCC-64       Coaxial Cable         UL Japan             -                 -              AT           2016/03/10 * 12
    MAT-10       Attenuator(10dB)      Weinschel Corp       2                 BL1173         AT           2016/11/28 * 12
    MOS-29       Thermo-Hygrometer     Custom               CTH-201           2901           AT           2017/01/20 * 12
    MMM-08       DIGITAL HiTESTER      Hioki                3805              051201197      AT           2017/01/19 * 12




The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means
of an unbroken chains of calibrations.

Test Item:          AT: Antenna Terminal Conducted test



                                                 End of Report




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2017-04-13 11:32:34
Document Modified: 2017-04-13 11:32:34