Test Report

FCC ID: VG8XMD34NYY-SPCB

Test Report

Download: PDF
FCCID_4084374

                                                     FCC PART 18
                                                    TEST REPORT
                                                                     For

                     Guangdong Midea Kitchen Appliances
                           Manufacturing Co.,Ltd
                          No.6, Yong An Road, Beijiao, Shunde, Foshan, Guangdong, China


                                    FCC ID: VG8XMD34NYY-SPCB


               Report Type:                                               Product Type:
               Original Report                                            Microwave Oven



                   Report Number:              RSZ180807560-00


                        Report Date:           2018-11-15

                                               Xiangguang Kong

                        Reviewed By:           Engineer

                        Prepared By:           Bay Area Compliance Laboratories Corp. (Shenzhen)
                                               6/F., West Wing, Third Phase of Wanli Industrial Building,
                                               Shihua Road, Futian Free Trade Zone, Shenzhen,
                                               Guangdong, China
                                               Tel: +86-755-33320018
                                               Fax: +86-755-33320008
                                               www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the
Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                            Report No.: RSZ180807560-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
OPERATING CONDITION/TEST CONFIGURATION ..........................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL CABLE LIST AND DETAILS .........................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
TEST EQUIPMENT LIST ...........................................................................................................................................7
CONDUCTED EMISSIONS ........................................................................................................................................9
 APPLICABLE STANDARD ..............................................................................................................................................9
 EUT SETUP ..................................................................................................................................................................9
 EMI TEST RECEIVER SETUP .........................................................................................................................................9
 TEST PROCEDURE ......................................................................................................................................................10
 TEST RESULTS SUMMARY ..........................................................................................................................................10
 TEST DATA ................................................................................................................................................................10
RADIATION HAZARD MEASUREMENT .............................................................................................................15
  APPLICABLE STANDARD ............................................................................................................................................15
  ENVIRONMENTAL CONDITIONS ..................................................................................................................................15
  RADIATION HAZARD MEASUREMENT ........................................................................................................................15
  INPUT POWER .............................................................................................................................................................15
  LOAD FOR MICROWAVE OVENS .................................................................................................................................16
  RF OUTPUT POWER MEASUREMENT ..........................................................................................................................16
  OPERATING FREQUENCY MEASUREMENT ..................................................................................................................17
  RADIATION HAZARD MEASUREMENT ........................................................................................................................20
  INPUT POWER .............................................................................................................................................................20
  LOAD FOR MICROWAVE OVENS .................................................................................................................................21
  RF OUTPUT POWER MEASUREMENT ..........................................................................................................................21
  OPERATING FREQUENCY MEASUREMENT ..................................................................................................................22
RADIATED EMISSIONS ...........................................................................................................................................26
  APPLICABLE STANDARD ............................................................................................................................................26
  EUT SETUP ................................................................................................................................................................26
  EMI TEST RECEIVER SETUP AND SPECTRUM ANALYZER SETUP................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................27
  TEST RESULTS SUMMARY ..........................................................................................................................................27
  TEST DATA AND PLOTS ..............................................................................................................................................28


FCC Part 18                                                                                                                                           Page 2 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ180807560-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd’s product, model number:
AMD34N5MA-S (FCC ID: VG8XMD34NYY-SPCB) or the “EUT” in this report is a Microwave Oven,
which was measured approximately: 55.3 cm (L) x 48.5 cm (W) x 34.3 cm (H), the input power is
AC 208V/230V 60Hz. The highest operating frequency is 2450 MHz.

Notes: This series products model: AMD34N##-S, AMD34N###-S (# express 0~9, A~Z) and AMD34N5MA-S are
electrically identical, model AMD34N5MA-S was selected for fully testing, the detailed information can be referred
to the declaration letter which was stated and guaranteed by the applicant.

*All measurement and test data in this report was gathered from production sample serial number: 1808023
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-08-07.


Objective
This report is prepared on behalf of Guangdong Midea Kitchen Appliances Manufacturing Co.,Ltd in
accordance with Part 2-Subpart J, and Part 18-Subparts A, B and C of the Federal Communication
Commissions rules and regulations.

The objective of the manufacturer is to determine compliance with FCC Part 18 limits.


Related Submittal(s)/Grant(s)
No related submittal(s).


Test Methodology
All measurements contained in this report were conducted with MP-5, FCC Methods of Measurements of
Radio Noise Emissions from ISM Equipment, February 1986. All measurements were performed at Bay
Area Compliance Laboratory Corporation. The radiated testing was performed at an antenna-to-EUT
distance of 3 meters.


Measurement Uncertainty

                                 Item                                   Expanded Measurement uncertainty
                AC Power Line Conducted Emissions                       2.20 dB (k=2, 95% level of confidence)
                                                Horizontal              4.58 dB (k=2, 95% level of confidence)
                         30MHz~200MHz
                                                  Vertical              4.59 dB (k=2, 95% level of confidence)
                                                Horizontal              4.83 dB (k=2, 95% level of confidence)
     Radiated emission   200MHz~1 GHz
                                                  Vertical              5.85 dB (k=2, 95% level of confidence)
                          1 GHz~6 GHz       Horizontal/Vertical         4.08 dB (k=2, 95% level of confidence)
                           Above 6 GHz      Horizontal/Vertical         4.59 dB (k=2, 95% level of confidence)
                       Occupied Bandwidth                                              ±0.5kHz
                          Temperature                                                   ±1.0℃




FCC Part 18                                                                                         Page 3 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ180807560-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.


The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 18                                                                               Page 4 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ180807560-00

OPERATING CONDITION/TEST CONFIGURATION
Justification
The EUT was operated at maximum (continuous) RF output power. The loads consisted of water in a glass
beaker in the amounts specified in the test procedure.


EUT Exercise Software
No exercise software was used.


Special Accessories
No special accessory was used.


Equipment Modifications
No modifications were made to the EUT tested.


Support Equipment List and Details

      Manufacturer           Description                   Model                  Serial Number
        High Power
                           AC Power Source                HPA-3130               HP180910909003
        Corporation


External Cable List and Details

              Cable Description                 Length (m)           From/Port                To

      Un-shielding Un-detachable AC Cable           1.0                  EUT                LISN


Configuration of Test Setup




                                                                Socket




FCC Part 18                                                                                  Page 5 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)          Report No.: RSZ180807560-00


Block Diagram of Test Setup
                                                                                    LISN


                                                             EUT

                                                           Receptacle




                                                                        1.0 Meter
                Non-conductive table
                80 cm above Ground Plane


                                              1.5 Meters




FCC Part 18                                                                         Page 6 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ180807560-00

TEST EQUIPMENT LIST
                                                             Serial           Calibration      Calibration
 Manufacturer             Description               Model
                                                            Number               Date           Due Date
                                         CONDUCTED EMISSIONS
Rohde & Schwarz        EMI Test Receiver       ESCS30        100176           2018-07-11        2019-07-11
                                                          3560.6650.12-
Rohde & Schwarz             LISN               ENV216                         2017-12-21        2018-12-21
                                                           101613-Yb
Rohde & Schwarz        Transient Limiter       ESH3Z2       DE25985           2018-05-21        2018-11-19
Rohde & Schwarz         CE Test software       EMC 32        V8.53.0             NCR               NCR
                      Conducted Emission                     UF A210B-1-
        /                                            N/A                      2018-05-12        2018-11-12
                            Cable                            0720-504504
                      Conducted Emission                     UF A210B-1-
        /                                            N/A                      2018-11-12        2019-05-12
                            Cable                            0720-504504
                                RADIATION HAZARD MEASUREMENT
Rohde & Schwarz         Signal Analyzer     FSIQ26    8386001028              2018-04-24        2019-04-24
   GW Instek             Power Meter       GPM 8212    CL110034               2018-04-09        2019-04-09

   GW Instek            AC Power Meter          GPM 8212      CL110045        2018-04-09        2019-04-09

     MC                  Thermometer                 N/A         N/A          2017-11-01        2018-11-01
     MC                  Thermometer                 N/A         N/A          2018-11-01        2019-11-01
  A.H.System             Horn Antenna                3115     9903-5766          NCR               NCR
                       Microwave Survery
      ETS                                            1501       N/A              NCR               NCR
                            Meter

    CAMRY             Electronic Weighed            EK3820      N/A           2017-11-02        2018-11-02

    CAMRY             Electronic Weighed            EK3820      N/A           2018-11-02        2019-11-02

   Ducommun                                    UFA210A-1-    MFR64369
                           RF Cable                                           2018-05-21        2018-11-19
  technologies                                 4724-30050U   223410-001
   Ducommun
                           RF Cable                 104PEA    218124002       2018-05-21        2018-11-19
  technologies




FCC Part 18                                                                                 Page 7 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ180807560-00

                                                                         Serial       Calibration      Calibration
 Manufacturer              Description                 Model
                                                                        Number           Date           Due Date
                                             RADIATED EMISSIONS
Sonoma Instrument           Amplifier                310N        186238               2018-05-12        2018-11-12
Sonoma Instrument           Amplifier                310N        186238               2018-11-12        2019-05-12
Rohde & Schwarz         EMI Test Receiver            ESCI        101120               2018-01-11        2019-01-11
  Sunol Sciences        Broadband Antenna             JB1       A040904-1             2017-12-22        2020-12-21
   A.H.System             Horn Antenna            SAS-200/571      135                2018-09-01        2021-08-31
Rohde & Schwarz          Signal Analyzer             FSEM      845987/005             2018-06-23        2019-06-23
  COM-POWER                Pre-amplifier            PA-122       181919               2018-08-01        2019-02-01
      TDK                    Chamber               Chamber A       2#                 2016-12-05        2019-12-05
      TDK                    Chamber               Chamber B       1#                 2016-12-06        2019-12-06
      R&S               Auto test Software          EMC32         V9.10                  NCR               NCR
     Agilent            Spectrum Analyzer            8564E     3943A01781             2018-01-04        2019-01-04
   the electro-
                           Horn Antenna                3116            9510-2270      2016-10-14        2019-10-14
  Mechanics Co.

Heatsink Required            Amplifier          QLW-18405536-J0 15964001002           2018-08-01        2019-02-01

                                                  2PS-1401-2760-
IW MICROWAVE                 RF Cable                                    SN 03        2018-05-22        2018-11-22
                                                       2ps
    Ducommun                                    UFA210A-1-4724-       MFR64369
                             RF Cable                                                 2018-05-21        2018-11-19
   technologies                                    30050U             223410-001
    Ducommun
                             RF Cable                 104PEA           218124002      2018-05-21        2018-11-19
   technologies

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 18                                                                                         Page 8 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ180807560-00

CONDUCTED EMISSIONS
Applicable Standard
FCC §18.307


EUT Setup




The setup of EUT is according with MP-5: 1986 measurement procedure. Specification used was with the
FCC Part 18.

The socket was connected to a 230 VAC/ 60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




FCC Part 18                                                                                 Page 9 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ180807560-00

Test Procedure
Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC PART 18,

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL., U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

              Temperature:                25 ℃
         Relative Humidity:               52 %
            ATM Pressure:               101.0 kPa

     The testing was performed by Hardy Wang on 2018-08-13 and 2018-11-15.




FCC Part 18                                                                                       Page 10 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                     Report No.: RSZ180807560-00

     EUT operation mode: Boiling Water with MAX Power & Fan Maximum


     AC 230V/60Hz, Line



                         90


                         80


                         70

                                                                                                       QP
                         60
          Level in dBu




                                                                                                       AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M       2M     3M     4M 5M 6    8 10M       20M     30M
                                                       Frequency in Hz



                                Corrected     Corrected
        Frequency                                                Limit         Margin           Remark
                                Amplitude      Factor
          (MHz)                                                 (dBμV)          (dB)          (PK/QP/Ave.)
                                 (dBμV)         (dB)
         0.169500                  53.5         19.8             65.0              11.5            QP
         0.490710                 53.1          19.8             56.2              3.1             QP
         0.510410                 51.4          19.8             56.0              4.6             QP
         0.566370                 46.3          19.7             56.0              9.7             QP
         0.853370                 42.3          19.7             56.0              13.7            QP
         0.864830                 42.2          19.7             56.0              13.8            QP
         0.169500                 42.0          19.8             55.0              13.0           Ave.
         0.490710                 29.1          19.8             46.2              17.1           Ave.
         0.510410                 31.0          19.8             46.0              15.0           Ave.
         0.566370                 26.7          19.7             46.0              19.3           Ave.
         0.853370                 23.7          19.7             46.0              22.3           Ave.
         0.864830                 24.5          19.7             46.0              21.5           Ave.




FCC Part 18                                                                                           Page 11 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                      Report No.: RSZ180807560-00

     AC 230V/60Hz, Neutral



                         90


                         80


                         70

                                                                                                        QP
                         60
          Level in dBu




                                                                                                        AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M       2M     3M     4M 5M 6     8 10M       20M     30M
                                                       Frequency in Hz



                                Corrected     Corrected
        Frequency                                                Limit             Margin        Remark
                                Amplitude      Factor
          (MHz)                                                 (dBμV)              (dB)       (PK/QP/Ave.)
                                 (dBμV)         (dB)
         0.161500                  50.7         19.7             65.4               14.7            QP
         0.514170                 50.8          19.8             56.0               5.2             QP
         0.533870                 46.7          19.8             56.0               9.3             QP
         0.880950                 38.6          19.7             56.0               17.4            QP
         0.935930                 38.1          19.7             56.0               17.9            QP
         2.287410                 32.4          19.9             56.0               23.6            QP
         0.161500                 43.2          19.7             55.4               12.2           Ave.
         0.514170                 28.5          19.8             46.0               17.5           Ave.
         0.533870                 25.5          19.8             46.0               20.5           Ave.
         0.880950                 22.1          19.7             46.0               23.9           Ave.
         0.935930                 24.3          19.7             46.0               21.7           Ave.
         2.287410                 11.4          19.9             46.0               34.6           Ave.




FCC Part 18                                                                                            Page 12 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                      Report No.: RSZ180807560-00

     AC 208V/60Hz, Line



                       90


                       80


                       70

                                                                                                      QP
                       60
        Level in dBu




                                                                                                      AV
                       50


                       40


                       30


                       20


                       10


                       0
                       150k   300 400 500   800 1M         2M     3M     4M 5M 6    8 10M      20M     30M
                                                       Frequency in Hz




                               Corrected     Corrected
          Frequency                                               Limit            Margin        Remark
                               Amplitude      Factor
            (MHz)                                                (dBμV)             (dB)       (PK/QP/Ave.)
                                (dBμV)         (dB)
               0.258000           55.2         19.7               61.5              6.3              QP
               0.512000           53.2          19.8              56.3              3.1              QP
               0.732000           48.5          19.7              56.0              7.5              QP
               0.864000           52.3          19.7              56.0              3.7              QP
               1.056000           36.0          19.8              56.0              20.0             QP
               2.440000           42.8          19.9              56.0              13.2             QP
               0.258000           35.2          19.7              51.5              16.3             Ave.
               0.512000           29.6          19.8              46.3              16.7             Ave.
               0.732000           20.9          19.7              46.0              25.1             Ave.
               0.864000           25.0          19.7              46.0              21.0             Ave.
               1.056000           12.4          19.8              46.0              33.6             Ave.
               2.440000           20.3          19.9              46.0              25.7             Ave.




FCC Part 18                                                                                           Page 13 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                      Report No.: RSZ180807560-00

     AC 208V/60Hz, Neutral



                         90


                         80


                         70

                                                                                                        QP
                         60
          Level in dBu




                                                                                                        AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M       2M     3M     4M 5M 6     8 10M       20M     30M
                                                       Frequency in Hz



                                Corrected     Corrected
        Frequency                                                Limit             Margin        Remark
                                Amplitude      Factor
          (MHz)                                                 (dBμV)              (dB)       (PK/QP/Ave.)
                                 (dBμV)         (dB)
         0.296000                  52.2         19.8             60.4               8.2             QP
         0.300000                 51.4          19.8             60.2               8.8             QP
         1.064000                 41.9          19.8             56.0               14.1            QP
         1.218000                 37.2          19.7             56.0               18.8            QP
         1.358000                 33.2          19.8             56.0               22.8            QP
         1.428000                 33.9          19.8             56.0               22.1            QP
         0.296000                 35.1          19.8             50.4               15.3           Ave.
         0.300000                 38.0          19.8             50.2               12.2           Ave.
         1.064000                 13.9          19.8             46.0               32.1           Ave.
         1.218000                 19.2          19.7             46.0               26.8           Ave.
         1.358000                 10.8          19.8             46.0               35.2           Ave.
         1.428000                  9.7          19.8             46.0               36.3           Ave.

Note:
            1) Corrected Amplitude = Reading + Correction Factor
            2) Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation
            3) Margin = Limit – Corrected Amplitude


FCC Part 18                                                                                            Page 14 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180807560-00

RADIATION HAZARD MEASUREMENT
Applicable Standard
FCC §18.301


Environmental Conditions

              Temperature:              25 ℃
         Relative Humidity:             52 %
            ATM Pressure:             101.0 kPa

     The testing was performed by Hardy Wang on 2018-08-13 and 2018-11-15.


AC 230V/60Hz
Radiation Hazard Measurement
Radiation leakage was measured in the as-received condition with the oven door closed using a microwave
leakage meter.

A 275 mL water load was placed in the center of the oven and the oven was operated at maximum output
power.

   There was no microwave leakage exceeding a power level of 0.1mW/cm2 observed at any point 5 cm
or more from the external surface of the oven.

A maximum of 1.0 mW/cm2 is allowed in accordance with the applicable Federal Standards. Hence,
microwave leakage in the as-received condition with the oven door closed was below the maximum
allowed.


Input Power
Input power and current was measured using a power analyzer. A 1400mL water load was placed in the
center of the oven and the oven was operated at maximum output power. A 1400mL water load was
chosen for its compatibility with the procedure commonly used by manufacturers to determine their input
ratings.

           Input Voltage       Input Current        Measured Input Power     Rated Input Power
             (VAC/Hz)             (Amps)                  (Watts)                 (Watts)
              229.8/60              9.08                   2087                     2000



    Based on the measured input power, the EUT was found to be operating within the intended
specifications.




FCC Part 18                                                                                Page 15 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ180807560-00

Load for Microwave Ovens
For all measurements, the energy developed by the oven was absorbed by a dummy load consisting of a
quantity of tap water in a beaker. If the oven was provided with a shelf or other utensil support, this
support was in its initial normal position. For ovens rated at 1000 watts or less power output, the beaker
contained quantities of water as listed in the following subparagraphs. For ovens rated at more than 1000
watts output, each quantity was increased by 50% for each 500watts or fraction thereof in excess of 1000
watts. Additional beakers were used if necessary.
● Load for power output measurement: 1000 milliliters of water in the beaker located in the center of the
oven.
● Load for frequency measurement: 1000 milliliters of water in the beaker located in the center of the oven.
● Load for measurement of radiation on second and third harmonic: Two loads, one of 700 and the other
of 300 milliliters, of water are used. Each load is tested both with the beaker located in the center of the
oven and with it in the right front corner.


RF Output Power Measurement
A cylindrical container of borosilicate glass is used for the test. It has a maximum thickness of 3 mm, an
external diameter of approximately 190 mm and a height of approximately 90 mm. The mass of the
container is determined.

At the start of the test, the oven and the empty container are at ambient temperature. Water having an
initial temperature of 10 ºC ± 1 ºC is used for the test. The water temperature is measured immediately
before it is poured into the container.

A quantity of 1 100 g ± 5 g of water is added to the container and its actual mass obtained. The container is
then immediately placed in the centre of the oven shelf, which is in its lowest normal position. The oven is
operated and the time for the water temperature to attain 20 ºC ± 2 ºC is measured. The oven is then
switched off and the final water temperature is measured within 60 s.



       mw                 mc                 T0                T1                 T2                 t
       (g)                (g)               (ºC)              (ºC)               (ºC)               (s)

      1400               380.0              26.2               8.8               22.7               60

RF Output Power = (4.187 x_1400_x (22.7 –8.8 )+ 0.55 x 380.0 x (22.7- 26.2)) / 60= 1345.79Watts
P    is the microwave power output, in watts;
mw is the mass of the water, in grams;
mc   is the mass of the container, in grams;
T0   is the ambient temperature, in degrees Celsius;
T1   is the initial temperature of the water, in degrees Celsius;
T2   is the final temperature of the water, in degrees Celsius;
t    is the heating time, in seconds, excluding the magnetron filament heating-up time.




FCC Part 18                                                                                    Page 16 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180807560-00


   The measurement output power was found to be less than 500 watts. Therefore, in accordance with
Section 18.305 of Subpart-C, the measured out-of-band emissions were compared to the limit of
25μV/meter at a 300-meter measurement distance.

    The measured output power was found to exceed 500 watts. Therefore, in accordance with Section
18.305 of Subpart-C, the measured out-of-band emissions were compared with the limit calculated as
following:

                     LFS = 25*SQRT (Power Output/500)

                     LFS = 25*SQRT (1345.79/500)

                     LFS = 41.02

Where: LFS is the maximum allowable field strength for out-of-band emissions in μV/meter at a 300-
meter measurement distance. Power Output is the measured output power in watts.

                    LFS
                                           dBμV/m@300m                    dBμV/m@3m
                 μV/m@300m

                     41.02                     32.26                            72.26


          Note: Limit (dBμV/m@3m) = Limit (dBμV/m@300m) + 40(dB)


Operating Frequency Measurement
    Variation in Operating Frequency with Time

The operating frequency was measured using a spectrum analyzer. Starting with the EUT at room
temperature, a 1400mL water load was placed in the center of the oven and the oven was operated at
maximum output power. The fundamental operating frequency was monitored until the water load was
reduced to 20 percent of the original load.

The results of this test are as follows:

                    Frequency at Start time                    Frequency at End time
                            (MHz)                                     (MHz)

                             2460.52                                  2471.34

Refer to data pages for details of the variation in operating frequency with time measurement.




FCC Part 18                                                                                 Page 17 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)   Report No.: RSZ180807560-00

Start time:




End time:




FCC Part 18                                                       Page 18 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ180807560-00

     Variation in Operating Frequency with Line Voltage

The EUT was operated / warmed by at least 10 minutes of use with a 1400 mL water load at room
temperature at the beginning of the test. Then the operating frequency was monitored as the input voltage
was varied between 80 and 125 percent of the nominal rating.

The results of this test are as follows:


                    (Low voltage) Frequency                    (High voltage) Frequency
                            (MHz)                                       (MHz)

                             2466.53                                   2472.54



Please refer to following pages for details of the variation in operating frequency with line voltage
measurement.

Low Voltage:




FCC Part 18                                                                                    Page 19 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ180807560-00

High Voltage:




AC 208V/60Hz
Radiation Hazard Measurement
Radiation leakage was measured in the as-received condition with the oven door closed using a microwave
leakage meter.

A 275 mL water load was placed in the center of the oven and the oven was operated at maximum output
power.

   There was no microwave leakage exceeding a power level of 0.1mW/cm2 observed at any point 5 cm
or more from the external surface of the oven.

A maximum of 1.0 mW/cm2 is allowed in accordance with the applicable Federal Standards. Hence,
microwave leakage in the as-received condition with the oven door closed was below the maximum
allowed.


Input Power
Input power and current was measured using a power analyzer. A 1400mL water load was placed in the
center of the oven and the oven was operated at maximum output power. A 1400mL water load was
chosen for its compatibility with the procedure commonly used by manufacturers to determine their input
ratings.




FCC Part 18                                                                               Page 20 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ180807560-00

             Input Voltage         Input Current     Measured Input Power       Rated Input Power
               (VAC/Hz)               (Amps)               (Watts)                   (Watts)
               207.1/60                9.89                  2048                       2000

Note: Power was measure as manufacturer specified as below:

    Based on the measured input power, the EUT was found to be operating within the intended
specifications.


Load for Microwave Ovens
For all measurements, the energy developed by the oven was absorbed by a dummy load consisting of a
quantity of tap water in a beaker. If the oven was provided with a shelf or other utensil support, this
support was in its initial normal position. For ovens rated at 1000 watts or less power output, the beaker
contained quantities of water as listed in the following subparagraphs. For ovens rated at more than 1000
watts output, each quantity was increased by 50% for each 500watts or fraction thereof in excess of 1000
watts. Additional beakers were used if necessary.
● Load for power output measurement: 1000 milliliters of water in the beaker located in the center of the
oven.
● Load for frequency measurement: 1000 milliliters of water in the beaker located in the center of the oven.
● Load for measurement of radiation on second and third harmonic: Two loads, one of 700 and the other
of 300 milliliters, of water are used. Each load is tested both with the beaker located in the center of the
oven and with it in the right front corner.


RF Output Power Measurement
A cylindrical container of borosilicate glass is used for the test. It has a maximum thickness of 3 mm, an
external diameter of approximately 190 mm and a height of approximately 90 mm. The mass of the
container is determined.

At the start of the test, the oven and the empty container are at ambient temperature. Water having an
initial temperature of 10 ºC ± 1 ºC is used for the test. The water temperature is measured immediately
before it is poured into the container.

A quantity of 1400 g ± 5 g of water is added to the container and its actual mass obtained. The container is
then immediately placed in the centre of the oven shelf, which is in its lowest normal position. The oven is
operated and the time for the water temperature to attain 20 ºC ± 2 ºC is measured. The oven is then
switched off and the final water temperature is measured within 60 s.

       mw                    mc                T0              T1                 T2                 t
       (g)                   (g)              (ºC)            (ºC)               (ºC)               (s)

      1400                380.0               25.7             9.4               22.9               60




FCC Part 18                                                                                    Page 21 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ180807560-00

RF Output Power = (4.187 x_1400_x (22.9 –9.4 )+ 0.55 x 380.0 x (22.9- 25.7)) / 60= 1309.15Watts
P    is the microwave power output, in watts;
mw is the mass of the water, in grams;
mc   is the mass of the container, in grams;
T0   is the ambient temperature, in degrees Celsius;
T1   is the initial temperature of the water, in degrees Celsius;
T2   is the final temperature of the water, in degrees Celsius;
t    is the heating time, in seconds, excluding the magnetron filament heating-up time.


   The measurement output power was found to be less than 500 watts. Therefore, in accordance with
Section 18.305 of Subpart-C, the measured out-of-band emissions were compared to the limit of
25μV/meter at a 300-meter measurement distance.

    The measured output power was found to exceed 500 watts. Therefore, in accordance with Section
18.305 of Subpart-C, the measured out-of-band emissions were compared with the limit calculated as
following:

                     LFS = 25*SQRT (Power Output/500)

                     LFS = 25*SQRT (1309.15/500)

                     LFS = 40.45

Where: LFS is the maximum allowable field strength for out-of-band emissions in μV/meter at a 300-
meter measurement distance. Power Output is the measured output power in watts.

                    LFS
                                           dBμV/m@300m                    dBμV/m@3m
                 μV/m@300m

                     40.45                     32.14                            72.14


          Note: Limit (dBμV/m@3m) = Limit (dBμV/m@300m) + 40(dB)


Operating Frequency Measurement
    Variation in Operating Frequency with Time

The operating frequency was measured using a spectrum analyzer. Starting with the EUT at room
temperature, a 1400mL water load was placed in the center of the oven and the oven was operated at
maximum output power. The fundamental operating frequency was monitored until the water load was
reduced to 20 percent of the original load.

The results of this test are as follows:

                    Frequency at Start time                    Frequency at End time
                            (MHz)                                     (MHz)

                             2450.90                                  2473.15

Refer to data pages for details of the variation in operating frequency with time measurement.




FCC Part 18                                                                                 Page 22 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)   Report No.: RSZ180807560-00

Start time:




End time:




FCC Part 18                                                       Page 23 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ180807560-00

     Variation in Operating Frequency with Line Voltage

The EUT was operated / warmed by at least 10 minutes of use with a 1400 mL water load at room
temperature at the beginning of the test. Then the operating frequency was monitored as the input voltage
was varied between 80 and 125 percent of the nominal rating.

The results of this test are as follows:


                    (Low voltage) Frequency                    (High voltage) Frequency
                            (MHz)                                       (MHz)

                             2456.91                                   2472.54



Please refer to following pages for details of the variation in operating frequency with line voltage
measurement.

Low Voltage:




FCC Part 18                                                                                    Page 24 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)   Report No.: RSZ180807560-00

High Voltage:




FCC Part 18                                                       Page 25 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ180807560-00


RADIATED EMISSIONS
Applicable Standard
FCC §18.305 and FCC §18.309


EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the FCC MP - 5. The specification used was the FCC part 18 limits.


FCC Part 18                                                                                 Page 26 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ180807560-00

The socket was connected to 230 VAC/60 Hz power source.

EMI Test Receiver Setup and Spectrum Analyzer Setup
The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver and Spectrum Analyzer were set with the
following configurations:

     Frequency Range              RBW               Video B/W              IF B/W            Measurement

    30MHz – 1000 MHz             100 kHz              300 kHz              120kHz                  QP
                                  1MHz                3 MHz                    /                  PK.
        Above 1 GHz
                                  1MHz                 10 Hz                   /                  Ave.


Test Procedure
Maximizing procedure was performed on the six (6) highest emissions to ensure that the EUT complied
with all installation combinations.

The EUT was in the normal (naïve) operating mode during the final qualification test to represent the
worst results.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 18,

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL., U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.




FCC Part 18                                                                                       Page 27 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ180807560-00

Test Data and Plots
     Environmental Conditions

                Temperature:              25 ℃
           Relative Humidity:             52 %
              ATM Pressure:             101.0 kPa

     The testing was performed by Hardy Wang on 2018-08-13 and 2018-11-15.

EUT Operation Mode: Boiling Water with MAX Power & Fan Maximum

AC208V/60Hz:
     30 MHz – 1 GHz:


                 Corrected               Antenna          Turntable         Correction
   Frequency                                     Antenna                                 Limit     Margin
                 Amplitude      PK/QP     height           position          Factor
     (MHz)                                       Polarity                              (dBμV/m)     (dB)
                 (dBμV/m)                  (cm)            (degree)          (dB/m)
   31.624625        15.60        QP       129.0           V       10.0        -8.0       72.14      56.54
   87.642000        13.30        QP       208.0           V       141.0       -19.3      72.14      58.84
   186.825250       11.20        QP       251.0           V       29.0        -15.2      72.14      60.94
   225.018125       16.80        QP       142.0           V       218.0       -14.0      72.14      55.34
   374.880625       18.30        QP       231.0           H       308.0       -10.6      72.14      53.84
   524.998500       26.70        QP       169.0           V       194.0       -6.3       72.14      45.44


    Above 1 GHz:

                   Measuerment               Rx Antenna                                      FCC Part 18
                                                         Corrected Corrected
Frequency                          Turntable
                                                          Factor Amplitude
  (MHz)         Reading             Degree Height Polar                                   Limit        Margin
                        PK/QP/Ave.                        (dB/m) (dBμV/m)
                (dBμV)                       (m) (H / V)                                (dBμV/m)        (dB)

 4916.35         46.91       Ave.         103       1.3       H      5.34      52.25      72.14          19.89
 4916.35         48.53       Ave.         103       1.3       H      5.34      53.87      72.14          18.27
 4321.56         34.23       Ave.         115       1.4       V      3.30      37.53      72.14          34.61
 4321.56         33.67       Ave.         115       1.4       V      3.30      36.97      72.14          35.17
 7367.83         46.56       Ave.         310       2.3       H     12.02      58.58      72.14          13.56
 7367.83         44.38       Ave.         310       2.3       H     12.02      56.40      72.14          15.74




FCC Part 18                                                                                   Page 28 of 29


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ180807560-00


AC230V/60Hz:
     30 MHz – 1 GHz:


                   Corrected               Antenna          Turntable Correction
   Frequency                                       Antenna                         Limit             Margin
                   Amplitude     PK/QP      height           position  Factor
     (MHz)                                         Polarity                      (dBμV/m)             (dB)
                   (dBμV/m)                  (cm)            (degree)  (dB/m)
   94.573350         12.90         QP        131.0           V        0.0       -18.2      72.26      59.36
   113.339950        10.60         QP        233.0           V       41.0       -15.1      72.26      61.66
   143.873250         8.30         QP        226.0           V       89.0       -14.2      72.26      63.96
   246.618550        10.96         QP        162.0           V       308.0      -14.1      72.26       61.3
   265.220325        12.20         QP        241.0           V       303.0      -13.0      72.26      60.06
   693.471125        21.20         QP        189.0           V       294.0      -1.5       72.26      51.06



    Above 1 GHz:

                     Measuerment             Rx Antenna                                        FCC Part 18
                                                         Corrected Corrected
Frequency                          Turntable
                                                          Factor Amplitude
  (MHz)         Reading             Degree Height Polar                                     Limit        Margin
                        PK/QP/Ave.                        (dB/m) (dBμV/m)
                (dBμV)                       (m) (H / V)                                  (dBμV/m)        (dB)

 4932.46          47.06        Ave.          100       2.4       H      5.34     52.40      72.26          19.86
 4932.46          46.66        Ave.          57        2.4       V      5.34     52.00      72.26          20.26
 4208.82          30.52        Ave.          254       2.4       H      3.53     34.05      72.26          38.21
 4208.82          32.19        Ave.           2        1.7       V      3.53     35.72      72.26          36.54
 7403.06          48.39        Ave.          210       2.4       H     12.02     60.41      72.26          11.85
 7403.06          44.29        Ave.          147       1.9       V     12.02     56.31      72.26          15.95

Note:
        1)   Corrected Amplitude = Meter Reading + Correction Factor
        2)   Correction Factor = Antenna Factor + Cable Loss - Amplifier Gain
        3)    Margin = Limit – Corrected Amplitude
        4)    The data below 20dB to the limit was not recorded.




                                        ***** END OF REPORT *****




FCC Part 18                                                                                     Page 29 of 29



Document Created: 2018-11-21 21:19:18
Document Modified: 2018-11-21 21:19:18

© 2024 FCC.report