SET2018-13234 EMC FCC Part 18 Report-rev02

FCC ID: VG8XM262AYY2M392

Test Report

Download: PDF
FCCID_4067300

                                                                  Report No.: SET2018-13234




             EMC TEST REPORT
      Report No.: SET2018-13234

  Product Name: Microwave Oven

        FCC ID : VG8XM262AYY2M392

       Applicant: Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd.

         Address No.6, Yong An Road, Beijiao, Shunde, Foshan, China
  Received Date: 2018-10-23
    Tested Date: 2018-10-23—2018-10-26

       Issued by: CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd.

   Lab Location: Building 28/29, East of Shigu Xili Industrial Zone, Nanshan District
                 Shenzhen, Guangdong 518055, China
                 Tel: 86 755 26627338      Fax: 86 755 26627238




    This test report consists of 22 pages in total. It may be duplicated completely for legal
use with the approval of the applicant. It should not be reproduced except in full, without
the written approval of our laboratory. The client should not use it to claim product
endorsement by CCIC-SET. The test results in the report only apply to the tested sample.
The test report shall be invalid without all the signatures of testing engineers, reviewer and
approver. Any objections must be raised to CCIC-SET within 15 days since the date when
the report is received. It will not be taken into consideration beyond this limit.




CCIC-SET/T(00)                                                                  Page 1 of 22


                                                                     Report No.: SET2018-13234



                                               Test Report

Product Name .................... Microwave Oven
                                       XM262AYY-P/E, XM262AYYY-P/E, FGMO226NUF,
Model No. .........................
                                       FGMO226NUD, FPMO227NUF

Applicant ............................ Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd.

Applicant Address............. No.6, Yong An Road, Beijiao, Shunde, Foshan, China

Manufacturer ..................... Guangdong Midea Kitchen Appliances Manufacturing Co., Ltd.

Manufacturer Address ...... No.6, Yong An Road, Beijiao, Shunde, Foshan, China

Test Standards .................. 47 CFR Part 18

Test Result ......................... PASS

Tested by ..........................

                                       Fang Yun Lei Test Engineer           2018.10.26

Reviewed by ......................

                                       Chris You   Senior Engineer          2018.10.26

Approved by ......................

                                                                            2018.10.26
                                       Zhu Qi, Manager




CCIC-SET/T(00)                                                                     Page 2 of 22


                                                                                                             Report No.: SET2018-13234


                                                    TABLE OF CONTENTS
1.      GENERAL INFORMATION ....................................................................................................5

1.1     GENERAL DESCRIPTION OF EUT ......................................................................................5
1.2     Test Standards and Results ........................................................................................................7
1.3     Facilities and Accreditations ......................................................................................................8
1.3.1      Facilities ....................................................................................................................................8
1.3.2      Measurement Uncertainty .........................................................................................................8

2.      EQUIPMENTS LIST .................................................................................................................9

3.      EMC EMISSION TEST ...........................................................................................................10

3.1     Test Procedure ...........................................................................................................................10
3.1.1      Frequency For Normal Voltage ...............................................................................................10
3.1.2      Frequency For Line Voltage ....................................................................................................10
3.1.3      Measurement data ................................................................................................................... 11
3.2     RADIATION HAZARD TEST ................................................................................................ 11
3.2.1      Test Setup ................................................................................................................................ 11
3.2.2      Limit ........................................................................................................................................ 11
3.2.3      Test results ............................................................................................................................... 11
3.3     RF OUTPUT POWER MEASUREMENT ............................................................................12
3.3.1      Test Standard ...........................................................................................................................12
3.3.2      EUT Operating mode ..............................................................................................................12
3.3.3      Test Data..................................................................................................................................12

4.      CONDUCTED EMISSION .....................................................................................................13

4.1.1      Conducted Emission Limit ......................................................................................................13
4.1.2      Test Procedure .........................................................................................................................13
4.1.3      Test Setup ................................................................................................................................13

5.      RADIATED EMISSION ..........................................................................................................16

5.1.1      Radiated Emission Limits .......................................................................................................16
5.1.2      Test Setup ................................................................................................................................16

APPENDIX I:PHOTOGRAPHS OF EMC TEST CONFIGURATION .....................................21




CCIC-SET/T(00)                                                                                                                        Page 3 of 22


                                                         Report No.: SET2018-13234


                              Change History
    Issue           Date                       Reason for change
     1.0         2018.11.02                     First edition




CCIC-SET/T(00)                                                         Page 4 of 22


                                                                              Report No.: SET2018-13234



1.         GENERAL INFORMATION

1.1        GENERAL DESCRIPTION OF EUT
EUT Name ........................... :      Microwave Oven
Trade Name………………..:                         Midea
Brand Name…………………:                          N/A
Hardware Version ................. :        N/A
Software Version .................. :       N/A
Model                                       EUT Model Derived:
                                            XM262AYY-P/E,         XM262AYYY-P/E,        FGMO226NUF,
                                            FGMO226NUD,FPMO227NUF model designations as
                                            follows:
                                            X=A or E, Indicate controller Type;
                                            M: indicate microwave function;
                                            262: "2" indicate the microwave output power is 1200W,
                                            “62” indicate cavity capacity is 45 liters;
                                            A: indicate the design No.;
                                            YY/YYY: Indicate different appearance and color;
                                            -P/-E: Indicate various painted cacity;
                                            Model FGMO226NUF, FGMO226NUD, FPMO227NUF is
                                            same with model EM262A2ME-P, the difference is only the
                                            model name. Model EM262A2ME-P was chosen for the
                                            final testing..
Power Supply ....................... :      120V AC/60Hz
Rated input Power(microwave):               1700W
Rated output Power(microwave):              1200W
Frequency ............................. :   2450MHz(ClassB/Group 2)
Magnetron Model ................. :         2M392J
Magnetron Manufacturer ... :                WITOL
Description of Support Units :              -Load for power output measurement: 1200 milliliters of water in
                                            the beaker located in the center of the oven.
                                            -Load for frequency measurement: 1200 milliliters of water in
                                            the beaker located in the center of the oven.
                                            -Load for measurement of radiation on second and third
                                            harmonic: Two loads, one of 840 and the other of 360 milliliters,
                                            of water are used. Each load is tested both with the beaker
                                            located in the center of the oven and with it in the right front
                                            corner.


CCIC-SET/T(00)                                                                                 Page 5 of 22


                                                                       Report No.: SET2018-13234


                                    -Load for all other measurements: 840 milliliters of water, with
                                    the beaker located in the center of the oven.
Note 1: The EUT have the following typical setups during the test: Setup1: Running;
Note 2:For a more detailed description, please refer to Specification or User’s Manual supplied by the
       applicant and/or manufacturer.




CCIC-SET/T(00)                                                                          Page 6 of 22


                                                                        Report No.: SET2018-13234


1.2     Test Standards and Results
The objective of the report is to perform testing according to 47 CFR Part 18:

        No.         Identity                        Document Title
        1           47 CFR Part 18:2017             Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

                                              Emission
              Standard                 Item                   Class / Severity      Result
                               Conducted Emission
                                                                 18.307(b)          PASS
                              (150 kHz to 30 MHz)
         47 CFR PART 18
                                Radiated Emission
                                                                 18.305(b)          PASS
                                (30 MHz to1 GHz)




CCIC-SET/T(00)                                                                        Page 7 of 22


                                                                      Report No.: SET2018-13234


1.3       Facilities and Accreditations

1.3.1     Facilities

      CNAS-Lab Code: L1659

      CCIC-SET is a third party testing organization accredited by China National Accreditation
      Service for Conformity Assessment (CNAS) according to ISO/IEC 17025. The accreditation
      certificate number is L1659.

      FCC-Registration No.: CN5031

      CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd. EMC Laboratory has been
      registered and fully described in a report filed with the FCC (Federal Communications
      Commission). The acceptance letter from the FCC is maintained in our files. Designation
      Number: CN5031, valid time is until December 31, 2018.

      ISED Registration: 11185A-1

      CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd. EMC Laboratory has been
      registered by Certification and Engineering Bureau of Industry Canada for the performance of
      radiated measurements with Registration No. 11185A-1 on Aug. 04, 2016, valid time is until
      Aug. 03, 2019.

      NVLAP Lab Code: 201008-0

      CCIC-SET is a third party testing organization accredited by NVLAP according to ISO/IEC
      17025. The accreditation certificate number is 201008-0 Test Environment Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                      15°C - 35°C
 Relative Humidity (%):                 25% -75%
 Atmospheric Pressure (kPa):            86kPa-106kPa

1.3.2     Measurement Uncertainty

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

 Uncertainty of Conducted Emission:     Uc = 3.6 dB (k=2)
 Uncertainty of Radiated Emission:      Uc = 4.5 dB (k=2)




CCIC-SET/T(00)                                                                        Page 8 of 22


                                                                      Report No.: SET2018-13234



2.          EQUIPMENTS LIST

A. Equipments List:

                                                              Equipment    Calibration     Calibration
     Description       Manufacturer             Model
                                                                 No.          Date         Due. Date
     Test Receiver    ROHDE&SCHWARZ              ESIB7         A0501375     2018.06.03      2019.06.02


     Test Receiver    ROHDE&SCHWARZ              ESIB26        A0304218     2018.06.03      2019.06.02

     Semi-Anechoic
                           Albatross           9m*6m*6m        A0412372     2018.05.09      2019.05.08
       Chamber
     Test Antenna -
                              HP               CBL6111A        A9704202     2018.06.03      2019.06.02
        Bi-Log
Test Antenna – Horn   ROHDE&SCHWARZ              HF906         A0304225     2018.06.03      2019.06.02
                                               SAC-5MAC
Anechoic Chamber           Albatross                           A0304210     2018.05.09      2019.05.08
                                              12.8x6.8x6.4m
       Amplifier                                 MITEQ
                      ROHDE&SCHWARZ                            A0509366     2018.06.03      2019.06.02
      1G~18GHz                               AFS42-00101800
       Amplifier      Compliance Direction
                                               PAP-0203H       A0509377     2018.06.03      2019.06.02
      20M~3GHz              System
         Cable            SUNHNER            SUCOFLEX 100         /         2018.06.03      2019.06.02
         Cable            SUNHNER            SUCOFLEX 104      MY1758/4     2018.06.03      2019.06.02
     Test Receiver    ROHDE&SCHWARZ               ESCI        A130901475    2018.09.09       2019.09.08

         LISN         ROHDE&SCHWARZ             ENV216            /         2018.01.05      2019.01.04


         Cable         MATCHING PAD               W7              /         2018.06.03      2019.06.02


      EMF Meter            NARDA                ELT-400        A0510311     2018.09.01      2019.08.31


      EMF Probe            NARDA              B-Field Probe    A0510311     2018.09.01      2019.08.31


Digital Power meter       YOKOGWA                WT210         A1006680     2018.04.18      2019.04.17

Digital Temperature
                          YOKOGWA               MV2040         A1008687     2018.06.16      2019.06.15
         Meter




CCIC-SET/T(00)                                                                           Page 9 of 22


                                                                    Report No.: SET2018-13234



3.       EMC EMISSION TEST

3.1      Test Procedure
        Test Requirement:    47 CFR PART 18
             Test Method:    FCC/OST MP-5:1986
           Power Supply:     AC 120V/ 60Hz
        Frequency Range:     2400-2500MHz
                 Detector:   Peak
                   Limit:
                             ISM equipment may be operated at any frequency above 9KHz and the
                             frequency band 2400-2500MHz is allocated for use by ISM equipment




3.1.1    Frequency For Normal Voltage

   The operating frequency was measured using a spectrum analyzer. Starting with the EUT at room
temperature, a 840mL water load was placed in the center of the oven and the oven was operated at
maximum output power. The fundamental operating frequency was monitored until the water load
was reduced to 20 percent of the original load.

3.1.2    Frequency For Line Voltage

    The EUT was operated / warmed by at least 10 minutes of use with a 840mL water load at room
temperature at the beginning of the test. Then the operating frequency was monitored as the input
voltage was varied between 80 and 125 percent of the nominal rating.




CCIC-SET/T(00)                                                                    Page 10 of 22


                                                                     Report No.: SET2018-13234


3.1.3   Measurement data


                       Operating Mode                   Frequency(MHz)

                       Normal Voltage                     2401.7-2476.9

                        Line Voltage                      2411.1-2471.0



3.2     RADIATION HAZARD TEST

3.2.1   Test Setup

The EUT was set-up according to the FCC MP-5 and FCC Part 18 for radiation Hazard measurement.
The measurement was using a microwave leakage meter to measure the radiation leakage in the
as-received condition with the oven door closed A 840mL water load in a breaker was located in the
center of the oven and the microwave oven was set to maximum power. While the oven operating, the
microwavemeter will check the leakage and then record the maximum leakage.

3.2.2   Limit

A maximum of 1.0mW/cm2       is allowed in according with the applicable FCC standards

3.2.3   Test results

There was no microwave leakage exceeding a power level of 0.12mW/cm2 Observed at any point
5cm or more from the external surface of the oven




CCIC-SET/T(00)                                                                      Page 11 of 22


                                                                            Report No.: SET2018-13234


3.3         RF OUTPUT POWER MEASUREMENT

3.3.1       Test Standard

                         Test Requirement                         47 CFR PART 18
                           Test Method                          FCC/OST MP-5:1986
                          Power Supply                              AC120/60Hz

3.3.2       EUT Operating mode

Test the EUT in microwave mode with full power.

3.3.3       Test Data


                               ambient
 Mass of       Mass of the   temperature           Initial         Final        Heating        Output
 Water(g)     container(g)                    temperature(℃)   temperature(℃)   Time(S)     Power(Watt)
                                  (℃)


  1200            280             25.0              14.0            34.0          120          858.9




Formula:




P is the microwave power output, in watts

Mw is the mass of the water, in grams

Mc is the mass of the container, in grams

T0 is the ambient temperature, in degrees Celsius

T1 is Initial temperature of the water, in degrees Celsius

T2 is final temperature of the water, in degrees Celsius

T is heating time, in seconds, excluding the magnetron filament heating-up time




CCIC-SET/T(00)                                                                            Page 12 of 22


                                                                            Report No.: SET2018-13234



4.       CONDUCTED EMISSION

4.1.1    Conducted Emission Limit

                                                       Conducted Limit (dBµV)
 Frequency range (MHz)
                                          Quasi-peak                                Average
        0.15 - 0.50                        66 to 56                                 56 to 46
         0.50 - 5                             56                                       46
          5 - 30                              60                                       50
Note:
a) The limit decreases linearly with the logarithm of the frequency in therange 0.05 MHz to 0.5 MHz.
b) The lower limit is applicable at the transition frequency.

4.1.2    Test Procedure

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains
through a LISN which provides 50Ω/50µH of coupling impedance for the measuring instrument. The
Common Antenna is used for the call between the EUT and the System Simulator (SS). A Pulse
Limiter is used to protect the measuring instrument. The factors of the whole test system are
calibrated to correct the reading.

4.1.3    Test Setup



                             80cm                         ≥80cm
        40cm
                EUT



         80cm                               LISN
                                                                          Receiver




CCIC-SET/T(00)                                                                              Page 13 of 22


                                                                                             Report No.: SET2018-13234


A. Test Result:

   Mains terminal disturbance voltage, L phase

    Marker:                             163.5 kHz                            49.22 dBµV
    Delta Mk:                                 0 Hz                           16.16 dB

      Level [dBµV]
   100


     80


     60


     40


     20


         0


   -20
             150k     300k       500k                 1M            2M      3M       5M   7M     10M            30M
                                                     Frequency [Hz]

             MES 18-16620 L PK
             MES 18-16620 L AV
             LIM FCC B QP                 Voltage QP Limit
             LIM FCC B AV                 Voltage AV Limit



                                                         (Plot A: L Phase)

                                  Conducted Disturbance at Mains Terminals
                                                            L Test Data
                             QP                                                                AV
   Frequen                    Measurem                               Frequen                    Measurem
                      Limits                            Margin                       Limits                  Margin
      cy                      ent Value                                 cy                       ent Value
                     (dBV)                              (dB)                       (dBV)                    (dB)
    (MHz)                      (dBV)                                 (MHz)                       (dBV)
    0.1635            65.30     46.23                    19.07           0.1635      55.30         24.85       30.45
    0.2760            60.90     44.02                    16.88           0.2760      50.90         22.54       28.36
    0.5460            56.00     34.33                    21.67           0.5460      46.00         22.85       23.15
    2.1885           56.00          24.61                31.39           2.1885      46.00         18.75       27.25
   12.7220           60.00          37.94                22.06           12.7220     50.00         18.34       31.66
   16.7900           60.00          37.26                22.74           16.7900     50.00         28.15       21.85




CCIC-SET/T(00)                                                                                             Page 14 of 22


                                                                                          Report No.: SET2018-13234


Mains terminal disturbance voltage, Setup 2, N phase
    Marker:                              906 kHz                             50.34 dBµV
    Delta Mk:                                 0 Hz                            5.72 dB

      Level [dBµV]
    100


      80


      60


      40


      20


          0


    -20
              150k     300k       500k                1M            2M      3M       5M   7M   10M            30M
                                                     Frequency [Hz]

              MES 18-16620 N PK
              MES 18-16620 N AV
              LIM FCC B QP                Voltage QP Limit
              LIM FCC B AV                Voltage AV Limit



                                                        (Plot B: N Phase)


                                   Conducted Disturbance at Mains Terminals
                                                            N Test Data
                             QP                                                       AV
  Frequen                     Measureme                                                Measureme
                      Limits                            Margin       Frequency Limits             Margin
     cy                        nt Value                                                  nt Value
                     (dBV)                              (dB)          (MHz)   (dBV)              (dB)
   (MHz)                        (dBV)                                                   (dBV)
   0.1500             66.00      43.92                   19.48         0.1500   56.00     28.59    27.41
   0.2895            60.50           40.22               20.98           0.2895       50.50      20.34        30.16
   0.9060            56.00           31.58               24.42           0.9060       46.00      18.67        27.33
   1.4685            56.00           28.37               31.63           1.4685       46.00      13.52        32.48
   10.9310           60.00           38.45               21.55           10.9310      50.00      18.76        31.24
   16.2635           60.00           27.38               32.62           16.2635      50.00      27.58        22.42

Test Result: PASS



CCIC-SET/T(00)                                                                                           Page 15 of 22


                                                                    Report No.: SET2018-13234



5.       RADIATED EMISSION

5.1.1    Radiated Emission Limits

(a) ISM equipment operation on a frequency specified in §18.301 is permitted unlimited radiated
    energy in the band specified for that frequency.
(b) The field strength levels of emissions which lie outside the bands specified in §18.301,unless
    otherwise indicated, shall not exceed the following:

     RF Power generated by equipment(watts)              Field strength limit(uV/m) @300m

                   Below 500                                            25

                  500 or more                                  25*SQRT(power/500)

Power =550.2W according to cluse7.2.2

Limit=20lg(25*SQRT(power/500))+20lg(300/3) @ 3m distance.

5.1.2    Test Setup

         For radiated emissions from 30MHz to1GHz




CCIC-SET/T(00)                                                                     Page 16 of 22


                                                                          Report No.: SET2018-13234


         For radiated emissions above 1GHz




5.1.3    Test Procedure

a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz. For
   frequencies above 1GHz, any suitable measuring distance may be used.

b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter open
   area test site. The table was rotated 360 degrees to determine the position of the highest radiation.

c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
   antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna
   are set to make the measurement.

d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode
   pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi
   Peak detector mode re-measured.

e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
   EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed.

f. For the actual test configuration, please refer to the related Item –EUT Test Photos.

Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three
      orthogonal axis. The worst case emissions were reported




CCIC-SET/T(00)                                                                             Page 17 of 22


                                                                                                    Report No.: SET2018-13234


   Test Result:

   Radiation disturbances, antenna polarization:                        Vertical

   Marker:                      37.775551 MHz                               48.11 dBµV/m

    Level [dBµV/m]
   80

   70

   60

   50

   40

   30

   20

   10

    0
          30M         50M          70M          100M                     200M        300M              500M        700M        1G
                                                    Frequency [Hz]

          MES ΢²¨Â¯-V
          LIM FCC part 18            Field Strength QP Limit




                                         (Plot C: Test Antenna Vertical 30M - 1G)


                                                           Antenna
        Frequency    QuasiPeak           Bandwidth                          Limit          Margin
                                                               height                                   Antenna           Verdict
          (MHz)       (dBμV/m)             (kHz)                          (dBμV/m)          (dB)
                                                               (cm)

          37.77         48.11             120.000              112.0        71.70          23.59        Vertical           Pass




CCIC-SET/T(00)                                                                                                       Page 18 of 22


                                                                                        Report No.: SET2018-13234


 Radiation disturbances, antenna polarization:Horizontal
   Marker:                     37.775551 MHz                        54.76 dBµV/m

    Level [dBµV/m]
  80

  70

  60

  50

  40

  30

  20

  10

    0
        30M          50M         70M        100M                 200M        300M           500M        700M          1G
                                               Frequency [Hz]

         MES ΢²¨Â¯-H
         LIM FCC part 18               Field Strength QP Limit




                                  (Plot D:         Test Antenna Horizontal 30M - 1G)



                                                       Antenna
       Frequency     QuasiPeak         Bandwidth                   Limit       Margin
                                                        height                              Antenna       Horizontal
         (MHz)       (dBμV/m)            (kHz)                    (dBμV/m)      (dB)
                                                         (cm)

         37.77         54.10            120.000          123.0     71.70        17.60      Horizontal          Pass




CCIC-SET/T(00)                                                                                           Page 19 of 22


                                                                 Report No.: SET2018-13234


Above 1GHz

           Freq.     Level    Factor      Limit      Margin    Height    Angle
  NO.                                                                              Polarity
         [MHz]     [dBμV/m]    [dB]     [dBμV/m]      [dB]      [cm]      [°]
   1    1205.46     42.17     -21.31     71.70       26.20      100      170       Vertical
   2    2264.87     59.37     -15.66     71.70        9.00      100       80       Vertical
   3    4375.16     57.46     -10.51     71.70       10.91      100      130       Vertical
   4    7378.05     55.71     -0.80      71.70       12.66      100       50       Vertical
   5    12004.5     56.58      7.39      71.70       11.79      100      270       Vertical
   6    12577.7     57.86     13.64      71.70       10.51      100      100       Vertical



         Freq.       Level    Factor     Limit      Margin     Height   Angle
  NO.                                                                              Polarity
        [MHz]      [dBμV/m]    [dB]    [dBμV/m]      [dB]       [cm]     [°]
   1    1493.24     46.38     -20.04     71.70       21.99      100      160      Horizontal
   2    1909.95     49.08     -17.52     71.70       19.29      100       50      Horizontal
   3    2343.67     61.58     -15.69     71.70        6.79      100      160      Horizontal
   4    4393.19     55.23     -10.56     71.70       13.14      100      250      Horizontal
   5    5209.60     58.44     -6.77      71.70        9.93      100      350      Horizontal
   6    7123.06     58.06     -1.82      71.70       10.31      100      230      Horizontal


REMARKS:
        1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
        2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
                                  – Pre-Amplifier Factor(dB)




CCIC-SET/T(00)                                                                   Page 20 of 22


                                              Report No.: SET2018-13234


 APPENDIX I:PHOTOGRAPHS OF EMC TEST CONFIGURATION

1. Radiated Emission Measurement below 1GHz




2. Radiated Emission Measurement above 1GHz




CCIC-SET/T(00)                                             Page 21 of 22


                                                              Report No.: SET2018-13234


3. Conducted emission at AC mains input/output port Measurement




CCIC-SET/T(00)                                                             Page 22 of 22


                                             Report No.: SET2018-13234


                 APPENDIX II:PHOTOGRAPHS OF EUT




CCIC-SET/T(00)


                 Report No.: SET2018-13234




CCIC-SET/T(00)


                 Report No.: SET2018-13234




CCIC-SET/T(00)


                                  Report No.: SET2018-13234

                 Internal Photo




CCIC-SET/T(00)


                 Report No.: SET2018-13234




CCIC-SET/T(00)


                 Report No.: SET2018-13234




CCIC-SET/T(00)


                 Report No.: SET2018-13234




CCIC-SET/T(00)


                                         Report No.: SET2018-13234

                 Led Lighting(ZH187AW)




CCIC-SET/T(00)


                                       Report No.: SET2018-13234

                 LED Lighting(YHW01)




CCIC-SET/T(00)


                                         Report No.: SET2018-13234

                       LED Lighing




                 ※※※ End Of Report ※※※



CCIC-SET/T(00)



Document Created: 2018-11-11 20:58:41
Document Modified: 2018-11-11 20:58:41