Test Report

FCC ID: VBA-EF202T

Test Report

Download: PDF
FCCID_2223071

                                                                      FCC ID: VBA—EF202T
                                                                       IC: 7098A—EF202T




                                  EMC TEST REPORT
                              No. 1402003978HA—001

           Applicant          : Everflourish Electrical Co.,Ltd.
                                Renjiu Village, Wuxiang Town, Yinzhou, Ningbo
                                  315111, China

           Manufacturer       :    Everflourish Electrical Co.,Ltd.
                                   Renjiu Village, Wuxiang Town, Yinzhou, Ningbo
                                  315111, China
           Equipment          : Remote control transmitter
           Type/Model         : EMW202T




SUMMARY
The equipment complies with the requirements according to the following standard(s):

47CFR Part 15 (2013): Radio Frequency Devices

ANSI €63.4 (2003): American National Standard for Methods of Measurement
of Radio—Noise Emissions from Low—Voltage Electrical and Electronic
Equipment in the Range of 9 kHz to 40 GHz

RSS—210 Issue 8 (December 2010); Low—power Licence—exempt Radio communication
Devices (All Frequency Bands): Category I Equipment

RSS—Gen Issue 3 (December 2010); General Requirements and Information for the
Certification of Radio communication Equipment



Date of issue: Feb 24, 2014




Prepared by: Jse /(?                                      Reviewed by:




Jesse Xu (Project Engineer)
                                                            )
                                                          Daniel Zhao (Reviewer)



                                           Page 1 of 20


                                                           FCC ID: VBA-EF202T
                                                            IC: 7098A-EF202T

Description of Test Facility
Name:        Intertek Testing Services Limited Shanghai
Address:     Building No.86, 1198 Qinzhou Road(North), Shanghai 200233, P.R. China

FCC Registration Number: 236597
IC Assigned Code: 2042B-1


Name of contact: Steve Li
Tel: +86 21 64956565 ext. 214
Fax: +86 21 54262335 ext. 214




                                     Page 2 of 20


                                                                                                                   FCC ID: VBA-EF202T
                                                                                                                    IC: 7098A-EF202T

                                                                       Content

SUMMARY.......................................................................................................................................................... 1
DESCRIPTION OF TEST FACILITY ......................................................................................................................... 2
1.  GENERAL INFORMATION ............................................................................................................................ 4
     1.1 Applicant Information ..................................................................................................... 4
     1.2 Identification of the EUT ................................................................................................ 4
     1.3 Technical specification ................................................................................................... 5
     1.4 Mode of operation during the test / Test peripherals used .............................................. 5
2.      TEST SPECIFICATION .................................................................................................................................. 6
     2.1 Instrument list ................................................................................................................. 6
     2.2 Test Standard .................................................................................................................. 6
3.      FUNDAMENTAL & SPURIOUS EMISSION & RESTRICT BAND RADIATED EMISSION ................................... 8
     3.1 Test limit ......................................................................................................................... 8
     3.2 Test Configuration .......................................................................................................... 9
     3.3 Test procedure and test setup .......................................................................................... 9
     3.4 Test protocol ................................................................................................................. 10
4.      DEACTIVATING TIME ................................................................................................................................ 12
     4.1 Test limit ....................................................................................................................... 12
     4.2 Test Configuration ........................................................................................................ 13
     4.3 Test procedure and test setup ........................................................................................ 13
     4.4 Test protocol ................................................................................................................. 13
5.      POWER LINE CONDUCTED EMISSION ........................................................................................................ 14
     5.1 Limit .............................................................................................................................. 14
     5.2 Test configuration ......................................................................................................... 14
     5.3 Test procedure and test set up ....................................................................................... 15
     5.4 Test protocol ................................................................................................................. 16
6.      EMISSION BANDWIDTH ............................................................................................................................. 17
     6.1 Test limit ....................................................................................................................... 17
     6.2 Test Configuration ........................................................................................................ 17
     6.3 Test procedure and test setup ........................................................................................ 17
     6.4 Test protocol ................................................................................................................. 18
7.      OCCUPIED BANDWIDTH ............................................................................................................................ 19
     7.1 Test limit ....................................................................................................................... 19
     7.2 Test Configuration ........................................................................................................ 19
     7.3 Test procedure and test setup ........................................................................................ 19
     7.4 Test protocol ................................................................................................................. 20




                                                                        Page 3 of 20


                                                             FCC ID: VBA-EF202T
                                                              IC: 7098A-EF202T

1. General Information

1.1 Applicant Information

Applicant:                      Everflourish Electrical Co.,Ltd.
                                Renjiu Village, Wuxiang Town, Yinzhou, Ningbo
                                315111, China
Name of contact:                Lisa Luo
Tel:                            86 574 88330888*8294
Fax:                            86 574 88330999
Manufacturer:                   Everflourish Electrical Co.,Ltd.
                                Renjiu Village, Wuxiang Town, Yinzhou, Ningbo
                                315111, China

Sample received date        :    Feb 17, 2014
Sample Identification No    :    *0140217-38-010*
Date of test                :    Feb 17, 2014 ~ Feb 23, 2014



1.2 Identification of the EUT

Equipment:                      Remote control transmitter
Type/model:                     EMW202T
FCC ID:                         VBA- EF202T
IC:                             7098A- EF202T




                                    Page 4 of 20


                                                                 FCC ID: VBA-EF202T
                                                                  IC: 7098A-EF202T

1.3 Technical specification

Operation Frequency Band:           433.92MHz
Modulation:                         ASK
Antenna Designation:                Integral antenna, non-user removable.
Gain of Antenna:                    1.2dBi
Rating:                             Battery: DC 3V
                                    Working frequency: 433.92MHz
Description of EUT:                 There is one model only.
                                    The EUT is a transmitter to control the working
                                    condition of the corresponding receiver.
Channel Description:                There is one channel only, namely 433.92MHz.




1.4 Mode of operation during the test / Test peripherals used

Within this test report, EUT was tested with modulation and tested under its rating voltage
and frequency.
The EUT is a handheld device, so three axes (X, Y, Z) were observed while the test receiver
worked as “max hold” continuously and the highest reading among the whole test procedure
was recorded.




                                        Page 5 of 20


                                                                FCC ID: VBA-EF202T
                                                                 IC: 7098A-EF202T

2. Test Specification

2.1 Instrument list
    Equipment           Type           Manu.         Internal no.    Cal. Date      Due date
  Test Receiver        ESIB 26          R&S           EC 3045       2012-10-21    2014-10-20
  Semi-anechoic           -          Albatross        EC 3048        2013-5-21     2014-5-20
     chamber                           project
  Bilog Antenna      CBL 6112D        TESEQ           EC 4206        2012-5-16     2014-5-15
   Horn antenna        HF 906           R&S           EC 3049        2012-5-13     2014-5-12
   Pre-amplifier     Pre-amp 18         R&S           EC 3222        2013-4-12     2014-4-11
  Test Receiver        FSV40            R&S              /           2013-10-21   2014-10-20
Loop antenna        9230-1/9229-1   Schwarzbeck      086814/084     2013-12-16    2014-12-15
                                                        814




2.2 Test Standard

47CFR Part 15 (2012)
ANSI C63.4: 2003
RSS-210 Issue 8 (December 2010)
RSS-Gen Issue 3 (December 2010)




                                      Page 6 of 20


                                                                 FCC ID: VBA-EF202T
                                                                  IC: 7098A-EF202T




2.3 Test Summary

This report applies to tested sample only. This report shall not be reproduced in part
without written approval of Intertek Testing Service Shanghai Limited.

           TEST ITEM      FCC REFERANCE               IC REFERANCE       RESULT
Fundamental & spurious        15.231(b)                RSS-210 Issue 8     Pass
emission                                                Annex A1.1.2
Restrict band radiated          15.205                 RSS-210 Issue 8    Pass
emission                                                 Clause 2.2
Power line conducted            15.207                RSS-Gen Issue 3     NA
emission                                                Clause 7.2.4
Emission bandwidth            15.231(c)                RSS-210 Issue 8    Pass
                                                        Annex A1.1.3
Deactivating time            15.231(a)(1)              RSS-210 Issue 8    Pass
                                                        Annex A1.1.1
Occupied bandwidth                 -                  RSS-Gen Issue 3    Tested
                                                        Clause 4.6.1




                                       Page 7 of 20


                                                                                               FCC ID: VBA-EF202T
                                                                                                IC: 7098A-EF202T



3. Fundamental & Spurious Emission & Restrict band radiated emission

     Test result:               PASS

3.1 Test limit

3.1.1 The emission shall test through the 10th harmonic or to 40GHz, whichever is lower. It
      must comply with the limits below:

        Fundamental Frequency     Fundamental limit    Spurious limit
               (MHz)                (uV/m)                (uV/m)
        ___________________________________________________________

             40.66 – 40.70            2250                225
             70 – 130                 1250                125
             130 - 174             1250 to 3750         125 to 375
             174 - 260                3750                 375
             260 – 470             3750 to 12500        375 to 1250
             Above 470                12500               1250
        ___________________________________________________________

The formulas for calculating the maximum permitted fundamental field strengths are as
follows: for the band 130-174 MHz, uV/m at 3 meters = 56.81818(Frequency) - 6136.3636;
for the band 260-470 MHz, uV/m at 3 meters = 41.6667(Frequency) - 7083.3333. The
maximum permitted unwanted emission level is 20 dB below the maximum permitted
fundamental level.

For that the EUT use fundamental frequency of 433.92MHz, after calculation, the limit is:

Fundamental limit = 41.6667 * 433.92 - 7083.3333 = 10996.68 uV/m = 80.80dBuV/m
Spurious limit = 81 – 20 = 60.80dBuV/m

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

3.1.2 The radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) showed as below:

Frequency          Field Strength     Measurement Distance
(MHz)               (dBuV/m)                (m)
___________________________________________________________
30 - 88               40.0                   3
88 - 216              43.5                   3
216 - 960             46.0                   3
Above 960              54.0                  3
______________________________________________________________



                                                           Page 8 of 20


                                                                  FCC ID: VBA-EF202T
                                                                   IC: 7098A-EF202T

3.2 Test Configuration




                                                                        EUT

           Antenna mast
                                                                       Turn Table




                            Test receiver




3.3 Test procedure and test setup

The measurement was applied in a semi-anechoic chamber. While testing for spurious
emission higher than 1GHz, the pre-amplifier and high pass filter is equipped just at the
output terminal of the antenna.
The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal
metal ground plane. The turn table rotated 360 degrees to determine the position of the
maximum emission level. The EUT was set 3 meters away from the receiving antenna which
was mounted on an antenna mast. The antenna moved up and down between from 1meter to
4 meters to find out the maximum emission level.
Both horizontal and vertical polarities of the receiving antenna were assessed and the higher
reading was listed in this report.
The radiated emission was measured using the test receiver with the resolutions bandwidth
set as:
RBW=300 Hz, VBW=1 kHz (9 kHz~150 kHz);
RBW=10kHz, VBW=30kHz (150kHz~30MHz);
RBW = 100kHz, VBW = 300kHz (30MHz~1GHz)
RBW = 1MHz, VBW = 3MHz (>1GHz for PK);




                                            Page 9 of 20


                                                               FCC ID: VBA-EF202T
                                                                IC: 7098A-EF202T


3.4 Test protocol

Antenna Frequency Correct Corrected              Emission       Limit  Margin Detector
          (MHz)   Factor   Reading                Type        (dBuV/m)
                  (dB/m) (dBuV/m)
   H         433.92      18.80      83.10      Fundamental      100.80      17.70      PK
   H         867.81      23.60      55.10       Harmonics       80.80       25.70      PK
   H        1737.47      -10.00     40.50       Harmonics       80.80       40.30      PK
   H        3036.07      -10.00     46.60       Harmonics       80.80       34.20      PK
   V         433.92      19.10      72.60      Fundamental      100.80      28.20      PK
   V         867.81      24.00      41.80       Harmonics       80.80       39.00      PK
   V        1296.59      -10.00     34.30       Harmonics       80.80       46.50      PK
   V        1737.47      -10.00     35.60       Harmonics       80.80       45.20      PK
   V        2194.38      -7.10      34.70       Harmonics       80.80       46.10      PK
   V        3909.81      -2.70      38.40         Restrict      74.00       35.60      PK
   H         407.00      17.40      23.40         Restrict      46.00       22.60      PK
   H        1720.12      -10.00     33.42         Restrict      74.00       40.58      PK

Remark: 1.Correct Factor = Antenna Factor + Cable Loss (+ Amplifier, for higher than
          1GHz)
       2. Corrected Reading = Original Receiver Reading + Correct Factor
       3. Margin = limit - Corrected Reading
       4. If PK reading is less than AV limit, the AV test can be elided.
Example: Assuming Antenna Factor = 30.20dB/m, Cable Loss = 2.00dB,
         Gain of Preamplifier = 32.00dB, Original Receiver Reading = 10.00dBuV, limit =
         40.00dBuV/m.
         Then Correct Factor = 30.20 + 2.00 – 32.00 = 0.20dB/m; Corrected Reading =
         10dBuV + 0.20dB/m = 10.20dBuV/m; Margin = 40.00dBuV/m - 10.20dBuV/m =
         29.80dB.




                                       Page 10 of 20


                                                                FCC ID: VBA-EF202T
                                                                 IC: 7098A-EF202T




Calculating the AV value according to the duty cycle
Antenna Frequency PK Reading Correct Factor                AV Reading     Limit  Margin
              (MHz)      (dBuV/m)             (dB)          (dBuV/m)    (dBuV/m) (dB)
   H         433.92         83.10                              72.93     80.80       7.87
   H         867.81         55.10                              44.93     60.80       15.87
   H        1737.47         40.50                              30.33     60.80       30.47
   H        3036.07         46.60                              36.43     60.80       24.37
                                             -10.17
   V         433.92         72.60                              62.43     80.80       18.37
   V         867.81         41.80                              31.63     60.80       29.17
   V        1737.47         35.60                              25.43     60.80       35.37
   V        2194.38         34.70                              24.53     60.80       36.27
Remark: 1.Correct Factor = 20lg (duty cycle) = 20lg (0.31) = -10.17
       2. AV Reading = PK Reading + Correct Factor
       3. Margin = limit - AV Reading




                                        Page 11 of 20


                                                                    FCC ID: VBA-EF202T
                                                                     IC: 7098A-EF202T


4. Deactivating time

   Test result:       PASS


4.1 Test limit

   (1) A manually operated transmitter shall employ a switch that will automatically
   deactivate the transmitter within not more than 5 seconds of being released.
   (2) A transmitter activated automatically shall cease transmission within 5 seconds after
   activation.
   (3) Periodic transmissions at regular predetermined intervals are not permitted.
   However, polling or supervision transmissions, including data, to determine system
   integrity of transmitters used in security or safety applications are allowed if the total
   duration of transmissions does not exceed more than two seconds per hour for each
   transmitter. There is no limit on the number of individual transmissions, provided the
   total transmission time does not exceed two seconds per hour.
   (4) Intentional radiators which are employed for radio control purposes during
   emergencies involving fire, security, and safety of life, when activated to signal an alarm,
   may operate during the pendency of the alarm condition.
   (5) Transmission of set-up information for security systems may exceed the transmission
   duration limits in (1) and (2) above, provided such transmission are under the control of a
   professional installer and do not exceed ten seconds after a manually operated switch is
   released or a transmitter is activated automatically. Such set-up information may include
   data.




                                          Page 12 of 20


                                                                 FCC ID: VBA-EF202T
                                                                  IC: 7098A-EF202T

4.2 Test Configuration




                                                                       EUT

           Antenna mast
                                                                      Turn Table




                           Test receiver



4.3 Test procedure and test setup

The measurement was applied in a semi-anechoic chamber.
The central frequency of test receiver was set as the operating frequency of EUT and the
Span was set as 0.
The EUT was switched once. The test receiver recorded the whole time from the triggered
moment to the time of stopping radiating. For manual switching, to avoid uncertainty, the
operating above would be repeated five times and the worst data is recorded.



4.4 Test protocol

Whole time from the triggered moment to the time of stopping radiating: 0.5s.
As a result, the EUT complies with the limit of 5s’ deactivating time.




                                        Page 13 of 20


                                                                  FCC ID: VBA-EF202T
                                                                   IC: 7098A-EF202T

5. Power line conducted emission

   Test result:           NA


5.1 Limit

                                                Conducted Limit (dBuV)
   Frequency of Emission (MHz)
                                                QP                      AV

             0.15-0.5                      66 to 56*                 56 to 46 *
                  0.5-5                         56                       46
                  5-30                          60                       50
  * Decreases with the logarithm of the frequency.




5.2 Test configuration




                                         EUT
                      Peripheral
                       devices




                          LISN           LISN                     EMI receiver


   For table top equipment, wooden support is 0.8m height table

   For floor standing equipment, wooden support is 0.1m height rack.




                                       Page 14 of 20


                                                                FCC ID: VBA-EF202T
                                                                 IC: 7098A-EF202T

5.3 Test procedure and test set up

The EUT are connected to the main power through a line impedance stabilization network
(LISN). This provides a 50Ω/50uH coupling impedance for the measuring equipment. The
peripheral devices are also connected to the main power through a LISN that provides a
50Ω/50uH coupling impedance with 50Ω termination.
Both sides (Line and Neutral) of AC line are checked for maximum conducted interference.
In order to find the maximum emission, the relative positions of equipment and all of the
interface cables must be changed according to ANSI C63.4 on conducted measurement.
The bandwidth of the test receiver is set at 9 kHz.




                                       Page 15 of 20


                                                              FCC ID: VBA-EF202T
                                                               IC: 7098A-EF202T

5.4 Test protocol


Power line: L
  Frequency     Correct Factor   Corrected Reading           Limit          Margin
                     (dB)              (dBuV)               (dBuV)           (dB)
                                     QP     AV           QP      AV       QP      AV
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
  Remark: 1. Correction Factor (dB) = LISN Factor (dB) + Cable Loss (dB).
          2. Margin (dB) = Limit - Corrected Reading.
          3. If the margin higher than 20dB, it would be marked as *.



Power line: N
  Frequency     Correct Factor   Corrected Reading           Limit          Margin
                     (dB)              (dBuV)               (dBuV)           (dB)
                                     QP     AV           QP      AV       QP      AV
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
      -               -              -           -        -        -      -        -
  Remark: 1. Correction Factor (dB) = LISN Factor (dB) + Cable Loss (dB).
          2. Margin (dB) = Limit - Corrected Reading.
          3. If the margin higher than 20dB, it would be marked as *.




                                      Page 16 of 20


                                                                FCC ID: VBA-EF202T
                                                                 IC: 7098A-EF202T

6. Emission Bandwidth
    Test Status: Pass



6.1 Test limit

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70 MHz and below 900 MHz. For devices operating above 900
MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is
determined at the points 20dB down from the modulated carrier.

The limit for the EUT = 0.25% * 433.92MHz = 1085kHz



6.2 Test Configuration




                                                                          EUT

                 Antenna mast
                                                                         Turn Table




                                Test receiver




6.3 Test procedure and test setup

The EUT and simulators were placed on a 0.8m high wooden turntable above the horizontal
metal ground plane. The turn table rotated 360 degrees to determine the position of the
maximum emission level. The EUT was set 3 meters away from the receiving antenna which
was mounted on an antenna mast. The antenna moved up and down between from 1meter to
4 meters to find out the maximum emission level.
The central frequency of test receiver was set near the operating frequency of EUT.
The test was conducted using the Spectrum Analyzer with the resolutions bandwidth set at
100kHz, the video bandwidth set at 300kHz.


                                        Page 17 of 20


                                                 FCC ID: VBA-EF202T
                                                  IC: 7098A-EF202T


6.4 Test protocol
    Temperature         :     25 °C
    Relative Humidity   :     55 %

            Channel         Emission Bandwidth        Limit
                                   (kHz)              (kHz)
               1                   466                 1085




                                Page 18 of 20


                                                                FCC ID: VBA-EF202T
                                                                 IC: 7098A-EF202T

7. Occupied Bandwidth
    Test Status: Tested



7.1 Test limit

None


7.2 Test Configuration




                                                                          EUT

                 Antenna mast
                                                                         Turn Table




                                Test receiver




7.3 Test procedure and test setup

The occupied bandwidth per RSS-Gen Issue 3 Clause 4.6.1 was measured using the
Spectrum Analyzer with the resolutions bandwidth set at 10kHz, the video bandwidth set at
30kHz.




                                        Page 19 of 20


                                                           FCC ID: VBA-EF202T
                                                            IC: 7098A-EF202T


7.4 Test protocol
    Temperature           :       25 °C
    Relative Humidity     :       55 %

               Channel            Occupied Bandwidth         Max. Value
                                        (MHz)                  MHz)
                  1                       0.102                 0.102
    Remark: “Max. Value” is the maximum test result of all the measured occupied
    bandwidth.




                                    Page 20 of 20



Document Created: 2014-03-19 14:24:01
Document Modified: 2014-03-19 14:24:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC