Test Report

FCC ID: V7TW322E

Test Report

Download: PDF
FCCID_2077650

NviAd
LABCODE: 500069—0
                                                        FCC PART 15B
                                                                                                                Bay Area Compliance             Labs Corp.




                                                         TEST REPORT
                                                                        For


               SHENZHEN TENDA TECHNOLOGY CO., LTD.
             Tenda Industrial Park, No 34—1, Shilong Rd., Shiyan Town, Bao‘an District, Shenzhen, China



                                                      FCC ID: V7ZTW322E



                    Report Type:                               Product Type:

                    Original Report                            Wireless N300 PCI Express Adapter


                                                                                            [eou\        CL@"‘
                              Test Engineer:         —_Leon Chen


                           Report Number:            R2DG130826001—00A


                                Report Date:         2013—09—11

                                                     Ivan Cao                                          p
                                                                                                /i"vam (pe
                               Reviewed By:          —_RF Leader

                           Test Laboratory:          Bay Area Compliance Laboratories Corp. (Dongguan)
                                                     No.69 Pulongeun, Puxinhu Industrial Zone,
                                                     Tangxia, Dongguan, Guangdong, China
                                                     Tel: +86—769—86858888
                                                     Fax: +86—769—86858891
                                                     www.baclcorp.com.cn




         Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
         used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the
         customerto claim product certification, approval, or endorsement by NVLAP®, or any agency of the Federal Government
         * This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk "¢"(Rev.2)
         This report is valid only with a valid digital signature. The digita. signature may be available only under the Adobe software above
         version 7.0


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                      Report No.: R2DG130826001-00A




                                                           TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION ..........................................................................................................................4
  JUSTIFICATION .............................................................................................................................................................4
  EUT EXERCISE SOFTWARE ..........................................................................................................................................4
  EQUIPMENT MODIFICATIONS .......................................................................................................................................4
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................4
  EXTERNAL CABLE........................................................................................................................................................4
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
SUMMARY OF TEST RESULTS ...............................................................................................................................6

FCC §15.107 – AC LINE CONDUCTED EMISSIONS .............................................................................................7
  MEASUREMENT UNCERTAINTY ....................................................................................................................................7
  EUT SETUP ..................................................................................................................................................................7
  EMI TEST RECEIVER SETUP .........................................................................................................................................8
  TEST PROCEDURE ........................................................................................................................................................8
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST RESULTS SUMMARY ............................................................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC §15.109 - RADIATED EMISSIONS .................................................................................................................12
  MEASUREMENT UNCERTAINTY ..................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................13
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................14
  TEST RESULTS SUMMARY ..........................................................................................................................................14
  TEST DATA ................................................................................................................................................................14




FCC Part15B                                                                                                                                              Page 2 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: R2DG130826001-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
 The SHENZHEN TENDA TECHNOLOGY CO., LTD.’s product, model number: W322E (FCC ID:
 V7TW322E) (the "EUT") in this report was a Wireless N300 PCI Express Adapter, which was measured
 approximately: 16.0 cm (L) x 12.0 cm (W) x 2.0 cm (H), rated input voltage: DC 3.3V from system

* All measurement and test data in this report was gathered from production sample serial number: 130826001
  (Assigned by BACL.Dongguan). The EUT was received on 2013-08-28.


Objective
This report is prepared on behalf of SHENZHEN TENDA TECHNOLOGY CO., LTD. in accordance with
Part 2, Subpart J, Part 15, Subparts A and B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine compliance with FCC Part 15B, Class B.


Related Submittal(s)/Grant(s)
FCC Part 15C DTS submissions with FCC ID: V7TW322E for Wifi.


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China
Test site at Bay Area Compliance Laboratories Corp. (Dongguan) has been fully described in reports
submitted to the Federal Communications Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on February 02, 2012.
The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2003.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
273710. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.

Additionally, Bay Area Compliance Laboratories Corp. (Dongguan) is an ISO/IEC 17025 accredited
laboratory, and is accredited by National Voluntary Laboratory Accredited Program (Lab Code 500069-0).




The current scope of accreditations can be found at http://ts.nist.gov/standards/scopes/5000690.htm




FCC Part15B                                                                                       Page 3 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: R2DG130826001-00A

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a typical fashion (as normally used by a typical user).


EUT Exercise Software
No software was used.


Equipment Modifications
No modification was made to the EUT.


Support Equipment List and Details


       Manufacturer                Description              Model                  Serial Number
              HP                     Printer                C3941A                  JPTVOB2337
           DELL                     Keyboard                 L100           CNORH656658907BL05DC
           SAST                      Modem                 AEM-2100                       0293
           DELL                        PC                   GX620                           /
           DELL                     Monitor                1706FPVT        CN-0T9401-71618-588-AJ9X
           DELL                      Mouse                 MO56UOA                   F0Y02P7Y


External Cable

                         Shielding                          Length
   Cable Description                        Ferrite Core                 From Port                  To
                           Type                              (m)
      Parallel Cable         yes                 No          1.2      Parallel Port of PC         Printer
       Serial Cable          yes                 No          1.2      Serial Port of PC          Modem
       VGA Cable             yes                 No          1.2       VGA Port of PC            monitor
       USB Cable             yes                 No          1.8       USB Port of PC             Mouse
       USB Cable             yes                 No          2.0       USB Port of PC            Keyboard




FCC Part15B                                                                                       Page 4 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: R2DG130826001-00A

Block Diagram of Test Setup



     L ISN 2
                                                                                                     L ISN 1




               M odem    10cm   Printer     10cm                     10cm             EUT
                                                     M onitor
                                                                            PC




                                                                                                         1.0 Meter
               N on-C onductive T able 80
               cm above G round Plane
                                                   K eyboard      10cm      M ouse

                                                     1.5 M eter




FCC Part15B                                                                                      Page 5 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: R2DG130826001-00A


SUMMARY OF TEST RESULTS


              FCC Rules                       Description of Test                  Results

               §15.107                   AC Line Conducted Emissions             Compliance

               §15.109                        Radiated Emissions                 Compliance




FCC Part15B                                                                                  Page 6 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: R2DG130826001-00A

FCC §15.107 – AC LINE CONDUCTED EMISSIONS
Measurement Uncertainty
Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit.

Based on CISPR 16-4-2: 2011, measurement uncertainty of conducted disturbance at mains port using AMN at
Bay Area Compliance Laboratories Corp. (Dongguan) is 3.46 dB (150 kHz to 30 MHz).

                                         Table 1 – Values of Ucispr

                                Measurement                                            Ucispr
Conducted disturbance at mains port using AMN (150 kHz to 30 MHz)                      3.4 dB


EUT Setup




FCC Part15B                                                                                     Page 7 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: R2DG130826001-00A

The setup of EUT is according with per ANSI C63.4-2003 measurement procedure. The specification used
was with the FCC Part 15.107 Class B limits.

The PC was connected to a 120 VAC/60 Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.
During the conducted emission test, the EMI test receiver was set with the following configurations:

                               Frequency Range                      IF B/W
                              150 kHz – 30 MHz                       9 kHz


Test Procedure
During the conducted emission test, the PC was connected to the outlet of the first LISN and the other
support equipments were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor


The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the maximum limit. The
equation for margin calculation is as follows:

        Margin = Limit – Corrected Amplitude




FCC Part15B                                                                                   Page 8 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: R2DG130826001-00A

Test Equipment List and Details

                                                                      Serial       Calibration    Calibration
      Manufacturer              Description           Model
                                                                     Number           Date         Due Date
                                EMI TEST
            R&S                                      ESCS 30        830245/006      2013-1-10      2014-1-9
                                RECIEVER
            R&S                   L.I.S.N            ESH3-Z5       843331/015       2012-9-17      2013-9-16

            R&S                   L.I.S.N            ESH3-Z5          100113        2012-11-29    2013-11-28

          BACL                 Test Software       BACL-EMC         V1.0-2010          N/A            N/A

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed in accordance to NVLAP requirements, traceable to National Primary Standards and
   International System of Units (SI).


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.107, with the
worst margin reading of:
                           15.52 dB at 18.550 MHz in the Line conducted mode


Test Data
     Environmental Conditions

              Temperature:              27.5 °C
        Relative Humidity:               63 %
            ATM Pressure:              100.7kPa

      The testing was performed by Leon Chen on 2013-09-06.




FCC Part15B                                                                                        Page 9 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)             Report No.: R2DG130826001-00A

      Test mode: Operating
     120 V, 60 Hz, Line:




                          Cord.         Correction
       Frequency                                      Limit    Margin         Detector
                         Reading         Factor
         (MHz)                                       (dBμV)     (dB)        (PK/AV/QP)
                         (dBμV)           (dB)
          0.210            42.37           0.42       63.21      20.84          QP
          0.210            35.31           0.42       53.21      17.90          AV
          0.470            32.11           0.31       56.51      24.40          QP
          0.470            15.94           0.31       46.51      30.57          AV
          0.630            33.81           0.31       56.00      22.19          QP
          0.630            19.18           0.31       46.00      26.82          AV
          1.020            33.86           0.32       56.00      22.14          QP
          1.020            25.64           0.32       46.00      20.36          AV
          10.920           30.94           1.03       60.00      29.06          QP
          10.920           29.93           1.03       50.00      20.07          AV
          18.480           39.26           2.35       60.00      20.74          QP
          18.550           34.48           2.36       50.00      15.52          AV




FCC Part15B                                                                     Page 10 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)             Report No.: R2DG130826001-00A

     120 V, 60 Hz, Neutral:




                           Cord.        Correction
         Frequency                                    Limit    Margin        Detector
                          Reading        Factor
           (MHz)                                     (dBμV)     (dB)       (PK/AV/QP)
                          (dBμV)          (dB)
            0.210          44.45            0.25      63.21     18.76          QP
            0.210          34.71            0.25      53.21     18.50          AV
            0.630          33.79            0.22      56.00     22.21          QP
            0.630          20.49            0.22      46.00     25.51          AV
            1.060          33.39            0.23      56.00     22.61          QP
            1.060          22.03            0.23      46.00     23.97          AV
            3.450          28.68            0.33      56.00     27.32          QP
            3.450          15.89            0.33      46.00     30.11          AV
           10.760          30.02            0.83      60.00     29.98          QP
           10.760          29.21            0.83      50.00     20.79          AV
           18.690          37.61            1.38      60.00     22.39          QP
           18.690          33.74            1.38      50.00     16.26          AV




FCC Part15B                                                                     Page 11 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: R2DG130826001-00A

FCC §15.109 - RADIATED EMISSIONS
Measurement Uncertainty
Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 2, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit.

Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 3m at Bay
Area Compliance Laboratories Corp. (Dongguan) is:
30M~200MHz: 5.0 dB
200M~1GHz: 6.2 dB
1G~6GHz: 4.45 dB
6G~18GHz: 5.23 dB
                                      Table 2 – Values of Ucispr

                                        Measurement                                            Ucispr
Radiated disturbance (electric field strength at an OATS or in a SAC) (30 MHz to 1000 MHz)     6.3 dB
Radiated disturbance (electric field strength in a FAR)           (1 GHz to 6 GHz)             5.2 dB
Radiated disturbance (electric field strength in a FAR)           (6 GHz to 18 GHz)            5.5 dB


EUT Setup
Below 1 GHz:




FCC Part15B                                                                                   Page 12 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: R2DG130826001-00A

Above 1GHz:




The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2003. The specification used was the FCC Part 15.109, Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.
The PC connected to a 120 VAC/60 Hz power source.


EMI Test Receiver Setup
According to FCC 15.33 requirements, the system was measured from 30 MHz to 6 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

              Frequency Range             RBW          Video B/W        IF B/W         Detector
              30MHz – 1000 MHz           120 kHz         300 kHz        120kHz            QP
                                          1MHz           3 MHz              /             PK
                 Above 1 GHz
                                          1MHz            10 Hz             /             Ave.


Test Procedure
For the radiated emissions test, the PC was connected to the first AC floor outlet and the other support
equipments were connected to the second AC floor outlet.
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
The data was recorded in Quasi-peak detection mode for 30 MHz to 1 GHz, Peak and average detection
mode above 1 GHz.




FCC Part15B                                                                                      Page 13 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: R2DG130826001-00A

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Loss + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial          Calibration   Calibration
    Manufacturer            Description            Model
                                                                    Number              Date        Due Date
                            EMI TEST
        R&S                                         ESCI             100224           2013-5-6      2014-5-5
                            RECEIVER
        Sunol
                              Antenna                JB3           A060611-1          2012-9-6      2015-9-5
      Sciences
         HP              HP AMPLIFIER              8447E          2434A02181            N/A           N/A
        R&S             Spectrum analyzer         FSEM 30         849016/001          2013-9-4      2014-9-3
   ETS LINDGREN           horn antenna              3115           000 527 35         2012-9-6      2015-9-5
     Mini-Circuit           Amplifier            ZVA-213-S+        54201245             N/A           N/A
        Farad               Test Software         EZ-EMC             V1.1.4.2           N/A           N/A

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
   have been performed in accordance to NVLAP requirements, traceable to National Primary Standards and
   International System of Units (SI).


Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.109, Class B, with the
worst margin reading of:

                  9.20 dB at 298.6900 MHz in the Horizontal polarization for below 1G


Test Data
     Environmental Conditions

            Temperature:              24.5 °C
       Relative Humidity:               55 %
          ATM Pressure:              100.7 kPa

      The testing was performed by Leon Chen on 2013-09-06.




FCC Part15B                                                                                        Page 14 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: R2DG130826001-00A

1) Below 1 GHz:
Test mode: Operating
Horizontal:




                   Receiver       Detector     Correction     Cord.
   Frequency                                                             Limit        Margin
                   Reading      (PK/QP/Ave)     Factor        Amp.
     (MHz)                                                             (dBuV/m)        (dB)
                  (dBuV/m)                       (dB)       (dBuV/m)
     32.9100        28.07           QP           -0.57        27.50      40.00         12.50
    144.4600        35.19           QP           -6.99        28.20      43.50         15.30
    261.8300        37.52           QP           -6.62        30.90      46.00         15.10
    288.0200        37.30           QP           -5.70        31.60      46.00         14.40
    298.6900        42.45           QP           -5.65        36.80      46.00         9.20
    747.8000        31.93           QP            2.17        34.10      46.00         11.90




FCC Part15B                                                                          Page 15 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: R2DG130826001-00A

Vertical:




                   Receiver       Detector     Correction     Cord.
   Frequency                                                             Limit        Margin
                   Reading      (PK/QP/Ave)     Factor        Amp.
     (MHz)                                                             (dBuV/m)        (dB)
                  (dBuV/m)                       (dB)       (dBuV/m)
     30.0000        25.35           QP            1.55        26.90      40.00         13.10
    143.4900        35.16           QP           -6.96        28.20      43.50         15.30
    276.3800        33.42           QP           -5.92        27.50      46.00         18.50
    299.6600        37.26           QP           -5.66        31.60      46.00         14.40
    747.8000        26.13           QP            2.17        28.30      46.00         17.70
    779.8100        32.10           QP            2.50        34.60      46.00         11.40




FCC Part15B                                                                          Page 16 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: R2DG130826001-00A

2) Above 1 GHz:
Test mode: Operating
Horizontal:




                   Receiver       Detector     Correction     Cord.
   Frequency                                                             Limit        Margin
                   Reading      (PK/QP/Ave)     Factor        Amp.
     (MHz)                                                             (dBuV/m)        (dB)
                  (dBuV/m)                       (dB)       (dBuV/m)
    1490.982        46.87          peak          -0.40        46.47      74.00         27.53
    1490.982        32.78          AVG           -0.40        32.38      54.00         21.62
    2993.988        35.97          peak           7.07        43.04      74.00         30.96
    2993.988        23.51          AVG            7.07        30.58      54.00         23.42
    5979.960        34.43          peak          11.78        46.21      74.00         27.79
    5979.960        20.89          AVG           11.78        32.67      54.00         21.33




FCC Part15B                                                                          Page 17 of 18


Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: R2DG130826001-00A

Vertical:




                   Receiver       Detector     Correction     Cord.
   Frequency                                                             Limit        Margin
                   Reading      (PK/QP/Ave)     Factor        Amp.
     (MHz)                                                             (dBuV/m)        (dB)
                  (dBuV/m)                       (dB)       (dBuV/m)
    1490.982        48.48          peak          -0.40        48.08      74.00         25.92
    1490.982        35.04          AVG           -0.40        34.64      54.00         19.36
    3745.491        35.04          peak           6.87        41.91      74.00         32.09
    3745.491        21.12          AVG            6.87        27.99      54.00         26.01
    5979.960        35.74          peak          11.78        47.52      74.00         26.48
    5979.960        21.57          AVG           11.78        33.35      54.00         20.65