        FCC RF EXPOSURE REPORT
                        FCC ID:V7TI9

Project No.   : 1709C144
Equipment     : Wireless Access Point
Model         : i9
Applicant     : SHENZHEN TENDA TECHNOLOGY CO., LTD.
Address       : 6-8 Floor, Tower E3, No. 1001, Zhongshanyuan
                Road,Nanshan District,Shenzhen,China

According: : FCC Guidelines for Human Exposure IEEE
             C95.1 & FCC Part 2.1091




              BTL                INC.
No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, China.
       TEL: +86-769-8318-3000      FAX: +86-769-8319-6000


 MPE CALCULATION METHOD:
        Calculation Method of RF Safety Distance:




       where:
       S = power density
       P = power input to the antenna
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator
       R = distance to the center of radiation of the antenna



Table for Filed Antenna

        Ant.         Brand           Model Name       Antenna Type    Connector Gain(dBi)
                                                        Internal
         1            N/A                N/A                             N/A         4.5
                                                       Antenna
                                                        Internal
         2            N/A                N/A                             N/A         4.5
                                                        Antenna


TEST RESULTS
  EUT:                Wireless Access Point         Model Name :       i9
  Temperature:        25 ℃                          Relative Humidity: 55 %
  Test Voltage :      AC 120V/60Hz


2.4G WIFI
   Antenna                                                 Power     Limit of Power
           Antenna Gain      Peak Output Peak Output                                    Test
     Gain                                                Density (S)   Density (S)
             (numeric)       Power (dBm) Power (mW)                                    Result
     (dBi)                                               (mW/cm2)      (mW/cm2)
     4.5        2.8184           29.71        935.4057    0.52475             1       Complies




Note: the calculated distance is 20 cm.