Test Report

FCC ID: V7TA30

Test Report

Download: PDF
FCCID_1707586

                                    FCC PART 15 CLASS B
                  MEASUREMENT AND TEST REPORT
                                                              For

     SHENZHEN TENDA TECHNOLOGY CO.,LTD.
      Tenda Industrial Park, No. 34-1, Shilong Rd., Shiyan Town, Bao'an District, Shenzhen,
                                            P.R.China


                                             FCC ID: V7TA30


              Report Type:                                   Product Type:
              Original Report                                300Mbps Wire less Range Extend er


                      Test Engineer:         Bin Jiang

                   Report Number:           R1DG120507002-00B

                        Report Date:        2012-05-23

                                             Ivan Cao
                       Reviewed By:          EMC Engineer

                                            Bay Area Compliance Laboratories Corp. (Shenzhen)
                                            6/F, the 3rd Phase of WanLi Industrial Building,
                   Test Laboratory:         ShiHua Road, FuTian Free Trade Zone
                                            Shenzhen, Guangdong, China
                                            Tel: +86-755-33320018
                                            Fax: +86-755-33320008
                                            www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the
customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government.
* This report contains data that are not covered by the NVLAP accreditation and are marked with an asterisk “★” (Rev.2)


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                       Report No.: R1DG120507002-00B




                                                       TABLE OF CONTENTS


GENERAL INFORMATION.......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  PRINTER .......................................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7

FCC §15.107 – AC LINE CONDUCTED EMISSIONS.............................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  TEST RESULTS SUMMARY ............................................................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC §15.109 - RADIATED EMISSIONS .................................................................................................................12
  MEASUREMENT UNCERTAINTY ..................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................13
  TEST PROCEDURE ......................................................................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................14




FCC Part 15 Class B                                                                                                                                      Page 2 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: R1DG120507002-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The SHENZHEN TENDA TECHNOLOGY CO.,LTD.’s product, model number: A30 (FCC ID: V7TA30)
or ("EUT”) in this report is a 300Mbps Wireless Range Extender, which was measured
approximately:13.0 cm (L) x8.5cm (W) x17.5cm (H), rated input voltage: DC 9V from adapter, the
operating frequency for EUT was 2412-2462MHz.

Adapter information:
Model: TEA09U-09060
Input: 100-240VAC, 50/60Hz, 0.3A
Output: 9V, 0.6A


* All measurement and test data in this report was gathered from production sample serial number:120507002
(Assigned by BACL). The EUT was received on 2012-05-08.


Objective
This report is prepared on behalf of SHENZHEN TENDA TECHNOLOGY CO.,LTD. in accordance with
Part 2- Subpart J, Part 15- Subparts A and B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 Class B.


Related Submittal(s)/Grant(s)
FCC Part 15C DTS submissions with FCC ID: V7TA30.


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Dongguan) has been fully described in reports and
was submitted to the Federal Communication Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on February 02, 2012.

The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2009. The Federal Communications Commission has the reports on file and is listed under FCC
Registration No.:273710. The test site has been approved by the FCC for public use and is listed in the
FCC Public Access Link (PAL) database.




FCC Part 15 Class B                                                                              Page 3 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                       Report No.: R1DG120507002-00B

Additionally, Bay Area Compliance Laboratories Corp. (Shenzhen) is an ISO/IEC 17025 accredited
laboratory, and is accredited by National Voluntary Laboratory Accredited Program (Lab Code 200707-
0).




The current scope of accreditations can be found at http://ts.nist.gov/Standards/scopes/2007070.htm




FCC Part 15 Class B                                                                         Page 4 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                      Report No.: R1DG120507002-00B

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in a typical mode which is provided by manufacture.


EUT Exercise Software
The test was performed under “Lantest.exe”.


Equipment Modifications
No modification was made to the EUT tested.


Local Support Equipment List and Details


      Manufacturer              Description               Model                 Serial Number

           Dell                  Notebook                 PP11L                QDS-BRCM1017
          DELL                   Keyboard             SK-8115            CNOJ46287161652IOYMU
            HP                    Printer             C3941A                     JPTVOB2337
          SAST                    Modem              AEM-2100                        0293


External I/O Cable

             Cable Description                  Length (m)          From Port                To
                                                                  Parallel Port of
      Shielded Detachable Printer Cable             1.2                                     Printer
                                                                    Notebook
                                                                   Serial Port of
       Shielded Detachable Serial Cable             1.2                                     Modem
                                                                    Notebook
                                                                   RJ45 port of
                  RJ45 cable                        1.0                                     EUT
                                                                    Notebook
                                                                   USB Port of
       Shielded Detachable USB Cable                1.5                                 Keyboard
                                                                    Notebook




FCC Part 15 Class B                                                                           Page 5 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                      Report No.: R1DG120507002-00B


Block Diagram of Test Setup



LISN
                                                                                                      LISN



                 10cm             10cm                  10cm            10cm
       m odem           Printer           Notebook               EUT




                                                        Adaper




                                                                                          1.0 Meter
                                                                   receptacle




            Non-Conductive Table 80
            cm above Ground Plane
                                             Keyboard

                                         1.5 M eter




FCC Part 15 Class B                                                                      Page 6 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                     Report No.: R1DG120507002-00B

SUMMARY OF TEST RESULTS



                  FCC Rules                 Description of Test             Results

                      §15.107           AC Line Conducted Emissions       Compliance

                      §15.109                Radiated Emissions           Compliance




FCC Part 15 Class B                                                                     Page 7 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                        Report No.: R1DG120507002-00B

FCC §15.107 – AC LINE CONDUCTED EMISSIONS
Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, and LISN.

Based on CISPR 16-4-2, The Treatment of Uncertainty in EMC Measurements, the best estimate of the
uncertainty of any conducted emissions measurement at Bay Area Compliance Laboratories Corp.
(Shenzhen) is 2.4 dB.(k=2, 95% level of confidence)


EUT Setup




The setup of EUT is according with per ANSI C63.4-2009 measurement procedure. The specification
used was with the FCC Part 15.107 Class B limits.

The spacing between the peripherals was 10 cm.

The adapter was connected to a 120 VAC/60 Hz power source.




FCC Part 15 Class B                                                                          Page 8 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: R1DG120507002-00B

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:
        Frequency Range                           IF BW
       150 kHz – 30 MHz                            9 kHz


Test Equipment List and Details

                                                                     Serial       Calibration   Calibration
       Manufacturer             Description           Model
                                                                    Number           Date        Due Date

     Rohde & Schwarz         EMI Test Receiver       ESCS30          100176       2011-11-24     2012-11-23

     Rohde & Schwarz              L.I.S.N.          ESH2-Z5       892107/021      2011-11-17    2012-11-16

        Com-Power                 L.I.S.N.            LI-200         12005           N/A           N/A

    * Statement of Traceability: Bay Area Compliance Laboratory Corp. attests that all calibrations have been
     performed in accordance to NVLAP requirements, traceable to the NIST.


Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the first LISN, the printer,
notebook and modem were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.107, with the
worst margin reading of:

                          11.51 dB at 3.975 MHz in the Neutral conducted mode


Test Data
     Environmental Conditions

               Temperature:          25 ° C
          Relative Humidity:          48 %
             ATM Pressure:          100.0 kPa

     The testing was performed by Bin Jiang on 2012-05-11.

    Test Mode: Ping



FCC Part 15 Class B                                                                               Page 9 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)            Report No.: R1DG120507002-00B

 120 V, 60 Hz, Line:




                       Corrected       Correction
       Frequency                                     Limit   Margin       Detector
                         Result         Factor
         (MHz)                                      (dBμV)    (dB)      (PK /QP/Ave.)
                        (dBμV)           (dB)
          4.160           32.13           0.50       46.00    13.87         Ave.

          5.840           35.73           0.52       50.00    14.27         Ave.

          4.160           41.42           0.50       56.00    14.58          QP

          5.845           44.92           0.52       60.00    15.08          QP

          6.810           34.62           0.54       50.00    15.38         Ave.

          6.890           44.24           0.54       60.00    15.76          QP

          3.235           30.17           0.49       46.00    15.83         Ave.

          3.235           39.51           0.49       56.00    16.49          QP

          7.880           42.72           0.58       60.00    17.28          QP

          1.145           37.84           0.45       56.00    18.16          QP

          1.150           27.83           0.45       46.00    18.17         Ave.

          7.880           31.59           0.58       50.00    18.41         Ave.




FCC Part 15 Class B                                                            Page 10 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)            Report No.: R1DG120507002-00B

120V, 60 Hz, Neutral:




                        Corrected      Correction
       Frequency                                     Limit   Margin       Detector
                          Result        Factor
         (MHz)                                      (dBμV)    (dB)      (PK /QP/Ave.)
                         (dBμV)          (dB)
          3.975           34.49           0.50       46.00    11.51         Ave.

          0.460           35.42           0.42       47.14    11.72         Ave.

          6.735           38.27           0.54       50.00    11.73         Ave.

          3.135           32.96           0.49       46.00    13.04         Ave.

          3.980           42.61           0.50       56.00    13.39          QP

          6.800           46.22           0.54       60.00    13.78          QP

          0.460           42.26           0.42       57.14    14.88          QP

          3.150           40.56           0.49       56.00    15.44          QP

          5.090           34.22           0.51       50.00    15.78         Ave.

          1.200           29.71           0.46       46.00    16.29         Ave.

          5.105           42.34           0.51       60.00    17.66         Ave.

          1.200           38.17           0.46       56.00    17.83         Ave.




FCC Part 15 Class B                                                            Page 11 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: R1DG120507002-00B

FCC §15.109 - RADIATED EMISSIONS
Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16-4-2, The Treatment of Uncertainty in EMC Measurements, the best estimate of the
uncertainty of a radiation emissions measurement at Bay Area Compliance Laboratories Corp. (Shenzhen)
is +4.0 dB. (k=2, 95% level of confidence)


EUT Setup




The radiated emission tests were performed in the 3 meters test site, using the setup accordance with the
ANSI C63.4-2009. The specification used was the FCC Part 15.109 Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

The adapter was connected to a 120 VAC/60 Hz power source.




FCC Part 15 Class B                                                                           Page 12 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                             Report No.: R1DG120507002-00B

EMI Test Receiver Setup
The system was investigated from 30 MHz to 2000 MHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:

        Frequency               RBW           VBW                  Detection

       30 MHz-1 GHz           100 kHz        300 kHz               Quasi-peak
       Above 1 GHz             1 MHz         3 MHz                  PK/Ave.


Test Procedure
During the radiated emissions test, the adapter, notebook, modem and the printer were connected to AC
floor outlet
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
Install combinations.
All data was recorded in the Quasi-peak detection mode from 30 MHz to 1 GHz.

Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
    Manufacturer            Description            Model
                                                                    Number            Date         Due Date
         HP                  Amplifier            HP8447E         1937A01046        2011-11-24    2012-11-23
  Rohde & Schwarz       EMI Test Receiver           ESCI             101122         2011-11-17    2012-11-16
    Sunol Sciences      Broadband Antenna            JB1           A040904-2        2011-11-28    2012-11-27

* Statement of Traceability: Bay Area Compliance Laboratories Corp (Shenzhen) attests that all calibrations have
 been performed in accordance to NVLAP requirements, traceable to the NIST.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Loss + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:
        Margin = Limit – Corrected Amplitude

Test Results Summary
According to the data in the following table, the EUT complied with the FCC §15.109 Class B, with the
worst margin reading of:

                               7.60 dB at 500.4500 MHz in the Vertical polarization




FCC Part 15 Class B                                                                               Page 13 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                       Report No.: R1DG120507002-00B


Test Data
     Environmental Conditions

            Temperature:            26 °C
       Relative Humidity:           60 %
          ATM Pressure:           100.0 kPa

      The testing was performed by Bin Jiang on 2012-05-11.

     EUT Operation Mode: ping

Horizontal




                                                              Corrected
   Frequency      Reading                Correction Factor                       Limit      Margin
                              Detector                        Amplitude
     (MHz)        (dBμV)                       (dB)                            (dBuV/m)      (dB)
                                                              (dBµV/m)
    500.4500          39.59     QP              -2.09           37.50            46.00        8.50
    250.1900          38.16     QP              -7.96           30.20            46.00       15.80
    299.6600          33.68     QP              -6.08           27.60            46.00       18.40
     32.9100          21.97     QP              -0.67           21.30            40.00       18.70
    119.2400          27.08     QP              -6.18           20.90            43.50       22.60
    109.5400          28.18     QP              -7.58           20.60            43.50       22.90




FCC Part 15 Class B                                                                       Page 14 of 15


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: R1DG120507002-00B

Vertical




                                                                    Corrected
   Frequency      Reading                   Correction Factor                              Limit          Margin
                                Detector                            Amplitude
     (MHz)        (dBμV)                          (dB)                                   (dBuV/m)          (dB)
                                                                    (dBµV/m)
    500.4500          40.49       QP                -2.09              38.40              46.00            7.60
    32.9100           29.57       QP                -0.67              28.90              40.00           11.10
    50.3700           40.39       QP               -11.99              28.40              40.00           11.60
    250.1900          38.06       QP                -7.96              30.10              46.00           15.90
    108.5700          35.28       QP                -7.78              27.50              43.50           16.00
    600.3600          31.04       QP                -1.14              29.90              46.00           16.10


Radiated Emissions 1GHz-2GHz.

             Frequency         Reading                 Corrected      Result      Limit       Margin         Antenna
    No.                                    Detector
               (MHz)          (dBuV/m)                   dB/m       (dBuV/m)    (dBuV/m)       (dB)          Polarity
     1          1395           41.03        Peak            17.63    58.66          74            15.34            H
     2          1395           24.36        Ave.            17.63    41.99          54            12.01            H
     5          1621           43.99        Peak            18.32    62.31          74            11.69            V
     6          1621           21.39        Ave.            18.32    39.71          54            14.29            V

 * Within measurement uncertainty.




                                       ***** END OF REPORT *****


FCC Part 15 Class B                                                                                  Page 15 of 15



Document Created: 2012-05-27 09:07:05
Document Modified: 2012-05-27 09:07:05

© 2024 FCC.report