SAR Calib Probe

FCC ID: V65S3150

RF Exposure Info

Download: PDF
FCCID_2143698

Calibration Laboratory of                                                                                   S     Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                            C     Service suisse d‘étalonnage
  Engineering AG                                                                                                  Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                      Swiss Calibration Service


Accredited by the Swiss Accreditation Service (SAS)                                             Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       UL CCS USA                                                                         Ceortificate No: EX3—3749_Jan13


CALIBRATION CERTIFICATE
 Object                               EX3DV4 — SN:3749


 Calibration procedure(s)             QA CAL—01.v8, QA CAL—14.v3, QA CAL—23.v4, QA CAL—25.v4
                                      Calibration procedure for dosimetric E—field probes



 Calibration date:                    January 15, 2013

This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


Calibration Equipment used (M&TE critical for calibration}



 Primary Standards                   ID                                 Cal Date (Certificate No.)                  Scheduled Calibration
 Power meter E4419B                  GB41293874                         29—Mar—12 (No. 217—01508)                   Apr—13
 Power sensor E4412A                 MY41498087                         29—Mar—12 (No. 217—01508)                   Apr—13
 Reference 3 dB Attenuator           SN: $5054 (3c)                     27—Mar—12 (No. 217—01531)                   Apr—13
 Reference 20 dB Attenuator          SN: $5086 (20b)                    27—Mar—12 (No. 217—01529)                   Apr—13
 Reference 30 dB Attenuator          SN: $5129 (30b)                    27—Mar—12 (No. 217—01532)                   Apr—13
 Reference Probe ES3DV2              SN: 3013                           28—Dec—12 (No. ES3—3013_Dec12)              Dec—13
 DAE4                                SN: 660                            20—Jun—12 (No. DAE4—660_Jun12)              Jun—13


 Secondary Standards                 ID                                 Check Date (in house)                       Scheduled Check
 RF generator HP 8648C               US3642U01700                      4—Aug—99 (in house check Apr—11)              In house check: Apr—13
 Network Analyzer HP 8753E           US37390585                         18—Oct—01 (in house check Oct—12)           in house check: Oct—13

                                          Name                                Function                                Signature
Calibrated by:                         Jeton Kastrati                         Laboratory Technician



Approved by:                           KatJa Pokovic                          Technical Manager
                                                                                                                  imz Issued: January 15, 2013
This calibration certificate shail not be reproduced except in full without written approval of the laboratory.




Certificate No: EX3—3749_Jan13                                       Page 1 of 11


Calibration Laboratory of                                     sNQ7z                           Schweizerischer Kalibrierdienst
Schmid & Partner                                             m“
                                                             t                                Service suisse d‘étalonnage
  Engineering AG                                             L7 e —rq
                                                              T            at
                                                                                              Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                   *4’?—fi\\“‘\\‘                  Swiss Calibration Service
                                                                 tw ) qu¥®



Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Glossary:
TSL                          tissue simulating liquid
NORMx,y,z                    sensitivity in free space
ConvF                        sensitivity in TSL / NORMx,y,z
DCP                          diode compression point
CF                           crest factor (1/duty_cycle) of the RF signal
A, B, C, D                   modulation dependent linearization parameters
Polarization q               @ rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                             iie., 8 = 0 is normal to probe axis

Calibration is Performed According to the Following Standards:
    a)   IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—Averaged Specific
         Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement
         Techniques", December 2003
    b)   IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) for hand—held devices used in close
         proximity to the ear (frequency range of 300 MHz to 3 GHz)", February 2005

Methods Applied and Interpretation of Parameters:
         NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; f > 1800 MHz: R22 waveguide).
         NORMx,y,z are only intermediate values, i.e., the uncertainties of NORMx,y,z does not affect the E—field
         uncertainty inside TSL (see below ConvF).
         NORM(P)x,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart). This linearization is
         implemented in DASY4 software versions later than 4.2. The uncertainty of the frequency response is included
         in the stated uncertainty of ConvF.
         DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of power sweep with CW
         signal (no uncertainty required). DCP does not depend on frequency nor media.
         PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
         characteristics
         Ax,y,z; Bx,y,z; Cx,y,2z; Dx,y,2z; VRx,y,z: A, B, C, D are numerical linearization parameters assessed based on
         the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
         media. VR is the maximum calibration range expressed in RMS voltage across the diode.
         ConvF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or Temperature Transfer
         Standard for f < 800 MHz) and inside waveguide using analytical field distributions based on power
         measurements for f > 800 MHz. The same setups are used for assessment of the parameters applied for
         boundary compensation (alpha, depth) of which typical uncertainty values are given. These parameters are
         used in DASY4 software to improve probe accuracy close to the boundary. The sensitivity in TSL corresponds
         to NORMx,y,z * ConvF whereby the uncertainty corresponds to that given for ConvF. A frequency dependent
         ConvF is used in DASY version 4.4 and higher which allows extending the validity from + 50 MHz to + 100
         MHz.
         Spherical isotropy (3D deviation from isotropy): in a field of low gradients realized using a flat phantom
         exposed by a patch antenna.
         Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center from the probe tip
         (on probe axis). No tolerance required.




Certificate No: EX3—3749_Jan13                                  Page 2 of 11


EX3DV4 — SN:3749                                                                January 15, 2013




                      Probe EX3DV4

                                          SN:3749

                                  Manufactured:             March 26, 2010
                                  Calibrated:              January 15, 2013



                                 Calibrated for DASY/EASY Systems
                                    (Note: non—compatible with DASY2 system!)




Certificate No: EX3—3749_Jan13                    Page 3 of 11


EX3DV4— SN:3749                                                                                                             January 15, 2013




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3749
Basic Calibration Parameters
                                                Sensor X                         Sensor Y                   Sensor Z             Unc (k=2)
 Norm (uV/(V/m)")*                                 0.49                            0.46                        0.42               +101 %
 DCP (mV)"                                         102.5                          106.4                       101.3

Modulation Calibration Parameters
 UID           Communication System Name                                   A              B         C          D          VR          Unc®
                                                                           dB        dByuV                    dB          mV          (k=2)
 0             CW                                                 X        0.0            0.0       1.0       0.00       167.4       £3.5 %
                                                                  Y¥       0.0            0.0       1.0                  160.4
                                                                  Z        0.0            0.0       1.0                  147.7



 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.


A The uncertainties of NormX,Y,Z do not affect the E*—field uncertainty inside TSL (see Pages 5 and 6).
® Numerical linearization parameter: uncertainty not required.
 Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value.




Certificate No: EX3—3749_Jan13                                     Page 4 of 11


EX3DV4— SN:3749                                                                                                             January 15, 2013




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3749


Calibration Parameter Determined in Head Tissue Simulating Media
                        Relative         Conductivity                                                                 Depth           Unct.
     f (MHz) C       Permitti\wityF         (S/m) F             ConvF X     ConvF Y       ConvF Z2       Alpha        (mm)            (k=2)

        750               41.9                 0.89              9.09         9.09           9.09         0.25         1.25         +12.0 %

        835               41.5                0.90               8.78         8.78           8.78         0.67         0.65         + 12.0 %

        900               41.5                0.97               8.84         8.84           8.84         0.17         1.48         + 12.0 %

        1750              40.1                 1.37              7.71         7.71           7.71         0.63         0.72         + 12.0 %

        1900              40.0                 1.40              7.34         7.34           7.34         0.67         0.73         #12.0 %

        1950              40.0                 1.40              7.01         7.01           7.01         0.51         0.78         + 12.0 %

        2000              40.0                 1.40              716          716            716          0.67         0.73         + 12.0 %

        2450              39.2                 1.80              6.44         6.44           6.44         0.37         1.02         + 12.0 %

       2600               39.0                 1.96              6.31         6.31           6.31         0.40         1.02         + 12.0 %

        5200              36.0                4.66               4.70         4.70           4.70         0.35         1.80         +13.1 %

        5300              35.9                4.76               4.48         4.48           4.48         0.35         1.80         +131 %

        5500              35.6                4.96               4.21         4.21           4.21         0.40         1.80         * 13.1 %

       5600               35.5                5.07               3.96         3.96           3.96         0.45         1.80         +13.1 %

        5800              35.3                 5.27              4.33         4.33           4.33         0.40         1.80         *#13.1 %



© Frequency validity of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else it is restricted to + 50 MHz. The uncertainty is the RSS
of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band.
" At frequencies below 3 GHz, the validity of tissue parameters (e and ) can be relaxed to + 10% if liquid compensation formula is applied to
measured SAR values. At frequencies above 3 GHz, the validity of tissue parameters (s and 0) is restricted to + 5%. The uncertainty is the RSS of
the ConvF uncertainty for indicated target tissue parameters.




Certificate No: EX3—3749_Jan13                                     Page 5 of 11


EX3DV4— SN:3749                                                                                                              January 15, 2013




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3749


Calibration Parameter Determined in Body Tissue Simulating Media
                       Relative           Conductivity                                                                 Depth           Unct.
     f (MHz) ©       PermittivityF           (S/m)"          ConvF X        ConvF Y        ConvFZ         Alpha        (mm)            (Kk=2)

        750               55.5                 0.96             8.78          8.78           8.78          0.34         1.04        + 12.0 %

        835               55.2                 0.97             8.67          8.67           8.67          0.71         0.67        + 12.0 %

        900               55.0                 1.05             8.62          8.62           8.62          0.53         0.77        + 12.0 %

        1750              53.4                 1.49             7.36          7.36           7.36          0.68         0.67        + 12.0 %

        1900              53.3                 1.52             6.99          6.99           6.99          0.36         0.99        + 12.0 %

        1950              53.3                 1.52             7.09          7.09           7.09          0.51         0.78        +12.0 %

       2000               53.3                 1.52             7.02          7.02           7.02          0.49         0.79        #12.0 %

       2450               52.7                 1.95             6.62          6.62           6.62          0.66         0.64        + 12.0 %

       2600               52.5                 2.16             6.37          6.37           6.37          0.80         0.56        + 12.0 %

       5200               49.0                 5.30             4.32          4.32           4.32          0.50         1.90        £#13.1 %

       5300               48.9                 5.42             4.07          4.07           4.07          0.55         1.90        £+13.1 %

       5500               48.6                 5.65             3.84           3.84          3.84          0.55         1.90         £+13.1 %

       5600               48.5                 5.77             3.58           3.58          3.58          0.60         1.90         #13.1 %

       5800               48.2                 6.00             3.97           3.97          3.97          0.55         1.90         +13.1 %



© Frequency validity of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else it is restricted to + 50 MHz. The uncertainty is the RSS
of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band.
" At frequencies below 3 GHz, the validity of tissue parameters (s and a) can be relaxed to + 10% if liquid compensation formula is applied to
measured SAR values. At frequencies above 3 GHz, the validity of tissue parameters (e and 0) is restricted to + 5%. The uncertainty is the RSS of
the ConvF uncertainty for indicated target tissue parameters.




Certificate No: EX3—3749_Jan13                                     Page 6 of 11


EX3DV4— SN:3749                                                                                                                                                                                                        January 15, 2013


                                                                         Frequency Response of E—Field
                                                                                   (TEM—Cell:ifi110 EXX, Waveguide: R22)




                                            {B—irmnmmmne reamecnemaamanommesnapmted(cmmmmmmamimmmmensdm
          Frequency response {normalized)




                                            4R rommvomeneeveernf pesnsts soutonne )frummemememce femmmmmmemsinesfrcrmmersersenadimnecmmsemmnmifiem


                                            1_0_............“.‘...‘“..‘.‘“..................;.4......4_4“......fi;-...m.—..,...or — ...‘.é.,........._-..-.._;I...._.,_._,.?.....,.......é,.,_,.,




                                                                                                                                                                                                                      4
                                                   TTTT




                                                                                                                                                                                                                          {
                                                  |—                                              |                             f                               |                                |                        |
                                            JB afccivsssrrarrenrre es Peap evererretareentie e dfruineeereviresertures fresweecsecescrecceccomfrereemecscecieessenses finsereteeenenireneveves faeess
                                                  |—                                              ;                             t                               |                                E                        |
                                                  |—                                              |                             f                               |                                !                        ;
                                            [ J —esccrerspreneycomne rap reran enveve e rre se en ere ce oo reerrer se on nee d Fere e o reuy it y on s cavien uh rar reiee on saie o n ue o n o ha n ie ree a ne n c ne uhh uo
                                                    |—                         i                          |                          |                           |                                                      [


                                            05                1     [    }     |    foohi—d               |   1      |     |    j    |     1    1    _|__|       |    JP         J    Of    B     f    PB   Of    }    ]     |

                                                   0                         500                      1000                          1500                     2000                          2500                       3000


                                                                                          ®                                                                                     &
                                                                                                                                    t [MHz]


                                                                        Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: EX3—3749_Jan13                                                                                           Page 7 of 11


EX3DV4— SN:3749                                                                                                                                                                                                                                                                                                                  January 15, 2013




                                                                                                 Receiving Pattern (¢), 9 = 0°

                                                  f=600 MHz,TEM                                                                                                                                                                          f=1800 MHz,R22


                                  135                                           *                                                               45                                                                     136                                           *                                                           45
                                                                            «
                                                                                                                                    *
                                                                                                                                                    L
                                                                                                                                                        R
                                                                                                                                                                                                                        #
                                                                                                                                                                                                                                                     a                                             +

                                            +                                                4                                                                                                                     /                                                         »                             .
                                                                                                  *                                                                                                                                                                                                        4


                                                                                                 +                                                              \                                              £                                                                                           4                                  \
                                    &                                   s                                                                                                                                     .I             T                                                   ®

                  '                         k     #                                  '           »                  &                                               \                                    I‘                                          *                   ]       }                 a                                 1            ‘




            IGL‘.I"                yo%                                      *~,
                                                                             .  wC .
                                                                                ow                                                      *     1«                        |in                      1                               %
                                                                                                                                                                                                                                                             ®       *
                                                                                                                                                                                                                                                                               "
                                                                                                                                                                                                                                                                             ~Kec®
                                                                                                                                                                                                                                                                                              .*                             +
                  I                               C                                          y                ooz       o«%)            ga\         oa                  )                            #                 &
                                                                                                                                                                                                                             t           *
                                                                                                                                                                                                                                                             g           ,*Tx**
                                                                                                                                                                                                                                                                             "o2, os                                   o8x ""od
                                                                                                                                                                                                                                                                                                                            *
                                                                                                                                                                                                                                                                                                                                                      i"
                                                                                                                                                                                                                                                                                                                                                      |
                                                                    *                                 %                                       * %                   }
                                                                                    +4                          * *.,__—*                                           )                                    1              |                    *       w                   1                *——4——*                                |                 1
                                                                                                                                                                                                          t            &                                                         4                                               +                f
                          t                            +                                 &                                                                      y                                              A         (                       f                       *                                     a                              /
                                                                                                                            }                                                                                                &                                               a                                               *            4
                                                       %                                 *                                                                  ¥                                                                                    U

                                                            x                                                           4                           e                                                                   e                            4
                                  728 L                                 *       SNelysyat *                                                 _5                                                                         28° .                                 *«                          wt*                             meo
                                                           }




                                                                                                                    t




                                                                                                                                                                                                                                                                     *~*#9~ * _
                                                           xX .It




                                                                                                                    -(I.|




                                                                                                                                                                N.[
              #




             Tot                                                                                                                                                                                     Tot




                      .                           t                                                       i                                                 [                               t                                        p                                               ;




                                                                                                                                                                                                                                     :
                                                       g
      é

          _9_5_.........,..5 1nrerucavexerssesessdens ‘“__;______L________JI
                                                                                                                                                                                                                                     &
                      R       1         I        E     T            1           1        1                E         1           1                                             1   1   I    ':        1             1__|                      1           1       1       1           |    I            I           1     1            }       I            1

                                                -1ka                                             —‘IbU                                                  gU                                [j.!                                       50                                          100                                             1%0
                                                                                                                                                                                      Roll [°]

                                                      10%—12                                                                                        GOQHZ                                                          18lffigfile                                                                           255!}'4Hz


                                                                                    Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: EX3—3749_Jan13                                                                                                                                                Page 8 of 11


EX3DV4— SN:3749                                                                                                                                                    January 15, 2013




                                           Dynamic Range f(SARneaq)
                                                          (TEM cell , f= 900 MHz)




                           105




                   3
                   G
                   f=)    104_ ........

                   oo               frt   TCt
                   3
                    ©k                                        cvcaehvaties
                   B                                                                                                                               fead ud




                          12—frmidne                 |                       ....... sfermenthieein        ob ccaoed            ifermttontictiboah
                                107                  10                             10°        101                              10°                          10}
                                                                                    SAR [mWicm3]
                                                         * ]
                                                not compensated                                                  compensated




                               2


                                1
                         mo
                         ko
                         §     0
                         u‘j        L

                               a{
                                    L.
                               _2   !            :   i    :              ;     .    |      B   F   I   I   :           I   LH         B    i   >



                                    102              101                           100        101                           102                    103
                                                        C                          SAR [mWW/cm3]

                                                not compensated                                                 compensated

                                          Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: EX3—3749_Jan13                                                     Page 9 of 11


EX3DV4— SN:3749                                                                                                                         January 15, 2013


                                 Conversion Factor Assessment
                 f= 835 MHz,WGLS RQ (H_convF)                                    f= 1900 MHz,WGLS R22 (H_convF)




                                                                                                                            a —&
                                                                                                                                   (tre— .0 * +
                                                                            A+‘,._{_I_L_LJ_A_;_I_._,‘_.<. 4.L _14—L1___J 4 _ AOL4G_ 4.4.
                                                                            0              10         15      20       25          30      36     40
                                                                                           ym               z [mm}
                                                                                           _¢]
                                               measured                                  analytical                           measured



                             Deviation from Isotropy in Liquid
                                                  Error (¢, 8), f = 900 MHz




                         —~1.0   —0.8   —0.6      —0.4    —0.2   0.0    0.2        0.4         0.6         0.8       1.0
                            Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: EX3—3749_Jan13                              Page 10 of 11


EX3DV4— SN:3749                                              January 15, 2013




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3749

Other Probe Parameters
 Sensor Arrangement                                              Triangular
 Connector Angle (°)                                                  —62.8
 Mechanical Surface Detection Mode                                 enabled
 Optical Surface Detection Mode                                    disabled
 Probe Overall Length                                              337 mm
 Probe Body Diameter                                                10 mm
 Tip Length                                                           9 mm
 Tip Diameter                                                       2.5 mm
 Probe Tip to Sensor X Calibration Point                              1 mm
 Probe Tip to Sensor Y Calibration Point                              1 mm
 Probe Tip to Sensor Z Calibration Point                              1 mm
 Recommended Measurement Distance from Surface                        2 mm




Certificate No: EX3—3749_Jan13               Page 11 of 11



Document Created: 2019-03-29 02:11:58
Document Modified: 2019-03-29 02:11:58