Conducted RF emissions report

FCC ID: V65C5215

Test Report

Download: PDF
FCCID_1969594

          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




                                 RF Emissions Test Report

                                       FCC Part 22 and 24

                                                     For

                                  Kyocera Corporation
                            c/o Kyocera Communication Inc.




                               Product:              Tri-Band CDMA Phone
                                Model:                           C5215




© 2013 Comptest Services LLC                         Page 1 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


               COMPTEST                                                                         Applicant:
                                                                                                 FCC ID:
                                                                                                                 Kyocera
                                                                                                                 V65C5215
                               Services LLC                                                     Report #:        CT-C5215-22_24-0413-R0

                                                         TABLE OF CONTENTS


1     SUMMARY OF TESTING ....................................................................................................... 4
2     EQUIPMENT UNDER TEST INFORMATION.......................................................................... 4
3     TEST FACILITIES ................................................................................................................... 5
4     TEST SETUP .......................................................................................................................... 5
5     Conducted RF OUTPUT POWER ........................................................................................... 6
    5.1 Test Configuration ............................................................................................................ 6
    5.2 Test Results ...................................................................................................................... 6
6     RADIATED RF OUTPUT POWER .......................................................................................... 6
    6.1 Test Configuration ............................................................................................................ 6
7     PEAK-AVERAGE RATIO ........................................................................................................ 7
    7.1 Test Configuration ............................................................................................................ 7
    7.2 Test Result ....................................................................................................................... 7
8     OCCUPIED BANDWIDTH ....................................................................................................... 9
    8.1 Test Configuration ............................................................................................................ 9
    8.2 Test Result ....................................................................................................................... 9
9     Spurious Emissions At Antenna Terminals ............................................................................ 14
    9.1 Test Configuration .......................................................................................................... 14
    9.2 Test Result ..................................................................................................................... 14
10 Transmitter Radiated Spurious Emissions ............................................................................. 21
  10.1 Test Configuration and Result ......................................................................................... 21
11 Receiver Spurious Emissions ................................................................................................ 21
  11.1 Receiver Spurious Emissions ......................................................................................... 21
12 Transmitter RF Carrier Frequency Stability ........................................................................... 22
  12.1 Test Configuration .......................................................................................................... 22
  12.2 Test Result ..................................................................................................................... 23
13 Exposure of Humans to RF Fields (SAR) .............................................................................. 25
  13.1 Test Configuration and Result ......................................................................................... 25
14 TEST EQUIPMENT ............................................................................................................... 25




© 2013 Comptest Services LLC                         Page 2 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0



                                             ATTESTATION

  The tested device complies with the requirements in respect of all parameters subject to the
  test.
  The test results and statements relate only to the items tested.
  The test equipment used was suitable for the tests performed and within manufacturer’s
  published specifications and operating parameters.
  The test methods were consistent with the methods described in the relevant standards.
                           Product: CDMA Cellular Phone with Bluetooth and WiFi

                           Model #: C5215

                             FCC ID: V65C5215

    Tested in accordance with: FCC Part 22 & 24

              Test performed by: CompTest Services LLC

              Test Requested by: Kyocera Corporation
                                 c/o Kyocera Communication Inc
                                 8611 Balboa Avenue
                                 San Diego, CA 92121 United States
                      Date of Test: April 1 - 8, 2013




    Responsible Engineer                                            Reviewed and approved by:

    Benjamin Nguyen                                                 Kelly Hill

    Benjamin Nguyen                                                 Kelly Hill
    Test Engineer                                                   Quality Manager




© 2013 Comptest Services LLC                         Page 3 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


            COMPTEST                                                    Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0



1         SUMMARY OF TESTING

 Section #     Rule Part                                  Test Description                            Verdict
      4        FCC § 2.1046                               Conducted Power                              Pass

      5        FCC § 22.913, 24.232                       Radiated Power                               Pass

      6        FCC § 2.1049, 22.917 (b)(d), 24.238        Occupied Bandwidth                           Pass
                                                          Spurious Emissions at Antenna
      7        FCC § 2.1051, 22.917(e)(f), 24.238                                                      Pass
                                                          Terminals
                                                          Transmitter Radiated Spurious
      8        FCC § 2.1053, 22.91, 24.238                                                             Pass
                                                          Emissions
      9        FCC § 15.109                               Receiver Spurious Emissions                  Pass
                                                          Transmitter RF Carrier Frequency             Pass
      10       FCC § 2.1055, 22.355, 24.235
                                                          Stability
      11       FCC § 2.1093                               Exposure of Humans to RF Fields              Pass



2         EQUIPMENT UNDER TEST INFORMATION

                  EUT Serial Number: 268435457816731604
                                  Type: [ ] Prototype, [X] Pre-Production, [ ] Production
                Equipment Category: Portable
           RF Exposure Environment: General Population / Uncontrolled
                              Antenna: Internal Antenna
                Detachable Antenna: No
                       External Input: Audio/Digital Data
                              Quantity: Quantity production is planned
            Multiple Access Scheme: CDMA
               Emission Designators: 1M25F9W
                      FCC Rule Parts: §22H                               §24E
                                Modes: 800 CDMA                          1900 CDMA
                TX Frequency (MHz): 824 – 849                            1850 - 1910
    Conducted Output Power (dBm): 24.5                                   24.5



© 2013 Comptest Services LLC                         Page 4 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0



3       TEST FACILITIES

The test sites and measurement facilities used to collect data are located at 8611 Balboa
Avenue, San Diego, CA 92123, USA



4       TEST SETUP

All CDMA measurements were conducted with a base station simulator to establish a CDMA link with
the equipment under test (EUT). To investigate the response of the EUT the main antenna RF output
port of the EUT was connected to the input of the spectrum analyzer with a RF cable. The amplitude
of the spectrum analyzer is corrected for the cable insertion loss and any other applicable losses. A
fully charged battery was used as a power supply voltage, except for the Transmitter RF Carrier
Frequency Stability test a dummy battery connected to a power supply was used.




                           Base Station                           Spectrum
                            Simulator                             Analyzer




                                            Directional
                                             Coupler




To justify on the selection of applicable configurations, the EUT was pre-tested under all Radio
Configuration and Service Option operation modes to determine the worst-case scenario.

The following CDMA configuration was determined and reported as worst-case for all measurements:

              Radio Configuration:                 RC1
              Service Options:                     SO55
              Data Rate:                           Full Rate




© 2013 Comptest Services LLC                         Page 5 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0



5       CONDUCTED RF OUTPUT POWER

 5.1     Test Configuration
     FCC: § 2.1046
        IC: RSS132 §4.4; RSS133 §6.4

 The EUT was connected to a Universal Power Meter through a RF cable. The cable loss
 was taken into account for accurate power measurement. The EUT was set at low, mid, high
 channels and each frequency band to investigate the conducted power.




 5.2     Test Results
                             Frequency                                           Conducted Power
         Mode                                          Channel
                               (MHz)                                                 (dBm)
                                824.70                   1013                            24.53
       CDMA 800                 836.52                    384                            24.42
                                848.31                    777                            24.45
                                1851.25                    25                            24.48
       CDMA 1900                 1880                     600                            24.50
                                1908.75                  1175                            24.60




6       RADIATED RF OUTPUT POWER

 6.1     Test Configuration
     FCC: § 22.913, § 24.232
        IC: RSS132 §4.4; RSS133 §6.4

 The test was performed in Compliance Certification Service using substitution method. See
 separated radiated emission report for details.




© 2013 Comptest Services LLC                         Page 6 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


             COMPTEST                                                   Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0



7       PEAK-AVERAGE RATIO

 7.1     Test Configuration
      FCC: § 24.232(d)
        IC: RSS133 (6.4)

    The RF output of the EUT was connected to the input of the spectrum analyzer (S.A.) with
    sufficient attenuation. The spectrum analyzer Complementary Cumulative Distribution
    Function (CCDF) function is utilized to determine the largest deviation between average
    and peak power of the EUT.

    For Digital: Modulate with full rate and all up power control bit.

     S.A. Setting                         RBW                         VBW
     Power Stat CCDF                      5MHz                        auto


 Limits: <13 dB




 7.2     Test Result

    Figure                                                            Mode                    Result
                               Description
       8-1                   CCDF @ Ch600                         CDMA 1900                     Pass




© 2013 Comptest Services LLC                         Page 7 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




                                         Figure 8-1 CCDF @ CH 600




© 2013 Comptest Services LLC                         Page 8 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


             COMPTEST                                                   Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




8       OCCUPIED BANDWIDTH

 8.1     Test Configuration
      FCC: § 2.1049, § 22.917(b)(d), § 24.238, § 27.53(g)(1)
        IC: RSS132 §4.5; RSS133 §6.5

    The RF output of the EUT was connected to the input of the spectrum analyzer (S.A.) with
    sufficient attenuation. The spectrum with no modulation was recorded.

    For Digital: Modulate with full rate all up power control bit.

     S.A. Setting                         RBW                         VBW
     Bandwidth Measurement                30KHz                       300kHz
     Band Edge Measurement                13kHz                       51kHz


 Limits: Bandwidth: N/A
         Bandedge: -13dBm




 8.2     Test Result

    Figure                                                            Mode                    Result
                               Description
       9-1                   CDMA @ Ch384                                                       Pass
       9-2           Lower Band Edge @ Ch 1013                     CDMA 800                     Pass
       9-3            Upper Band Edge @ Ch 777                                                  Pass
       9-4                  CDMA @ CH600                                                        Pass
       9-5            Lower Band Edge @ CH 25                     CDMA 1900                     Pass
       9-6           Upper Band Edge @ CH 1175                                                  Pass




© 2013 Comptest Services LLC                         Page 9 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




                                                                                               3
                                      Figure 9-1 CDMA 800 @ CH 384




© 2013 Comptest Services LLC                        Page 10 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




                          Figure 9-2 CDMA 800 Lower Band Edge @ CH 1013




                           Figure 9-3 CDMA 800 Lower Band Edge @ CH 777




© 2013 Comptest Services LLC                        Page 11 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




                                     Figure 9-4 CDMA 1900 @ CH 600




© 2013 Comptest Services LLC                        Page 12 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




                           Figure 9-5 CDMA 1900 Lower Band Edge @ CH 25




                          Figure 9-6 CDMA 1900 Upper Band Edge @ CH 1175


© 2013 Comptest Services LLC                        Page 13 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


            COMPTEST                                                    Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                          Services LLC                                  Report #:    CT-C5215-22_24-0413-R0



9       SPURIOUS EMISSIONS AT ANTENNA TERMINALS

 9.1     Test Configuration
     FCC: § 2.1051, § 22.917(e)(f), § 24.238
        IC: RSS132 §4.5; RSS133 §6.5

 Measurement Procedures:

    Out of Band: The RF output of the EUT was connected to the input of the spectrum
    analyzer with sufficient attenuation. The modulating signal was applied accordingly. The
    frequency spectrum was investigated from the lowest frequency signal generated up to at
    least the tenth harmonic of the fundamental.

     S.A. Setting                         RBW                        VBW
     Spurious Emissions
                                          1MHz                       1MHz
     Measurement


 Limits: -13dBm




 9.2     Test Result
    Figure     Channel                          Plot Description                                Result
     10-1         1013                                                                            Pass
                                 CDMA 800 Conducted spurious emissions
     10-2           384                    25MHz to 10GHz                                         Pass
     10-3           777                                                                           Pass
     10-4           25                                                                            Pass
                                 CDMA 1900 Conducted spurious emissions
     10-5           600                    25MHz to 20GHz                                         Pass
     10-6         1175                                                                            Pass




© 2013 Comptest Services LLC                        Page 14 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




              Figure 10-1a CDMA 800 – Conducted Spurious Emission (CH 1013)




              Figure 10-1b CDMA 800 – Conducted Spurious Emission (CH 1013)



© 2013 Comptest Services LLC                        Page 15 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




               Figure 10-2a CDMA 800 – Conducted Spurious Emission (CH 384)




               Figure 10-2b CDMA 800 – Conducted Spurious Emission (CH 384)




© 2013 Comptest Services LLC                        Page 16 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




               Figure 10-3a CDMA 800 – Conducted Spurious Emission (CH 777)




               Figure 10-3b CDMA 800 – Conducted Spurious Emission (CH 777)




© 2013 Comptest Services LLC                        Page 17 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




               Figure 10-4a CDMA 1900 - Conducted Spurious Emission (CH 25)




               Figure 10-4b CDMA 1900 - Conducted Spurious Emission (CH 25)




© 2013 Comptest Services LLC                        Page 18 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




              Figure 10-5a CDMA 1900 - Conducted Spurious Emission (CH 600)




              Figure 10-5b CDMA 1900 - Conducted Spurious Emission (CH 600)




© 2013 Comptest Services LLC                        Page 19 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0




              Figure 10-6a CDMA 1900 - Conducted Spurious Emission (CH 1175)




              Figure 10-6b CDMA 1900 - Conducted Spurious Emission (CH 1175)




© 2013 Comptest Services LLC                        Page 20 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0


10      TRANSMITTER RADIATED SPURIOUS EMISSIONS

10.1 Test Configuration and Result

    FCC: § 2.1053, § 22.91, § 24.238, §27.53(g)
       IC: RSS132 §4.5; RSS133 §6.5
The radiated spurious emission test was performed at Compliance Certification Service. The
test report is attached in a separate attachment.




11      RECEIVER SPURIOUS EMISSIONS

11.1 Receiver Spurious Emissions
   FCC: § 15.109
      IC: RSS-GEN
The receiver radiated spurious emission test was performed at Compliance Certification
Service. The test report is attached in a separate attachment.




© 2013 Comptest Services LLC                        Page 21 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


           COMPTEST                                                     Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0


12      TRANSMITTER RF CARRIER FREQUENCY STABILITY


 12.1 Test Configuration
     FCC: § 2.1055, § 22.355, § 24.235, § 27.54
       IC: RSS132 §4.3; RSS133 §6.3
 The EUT was placed in an environmental chamber. The RF output of the EUT was
 connected to Agilent 8960 Series 10 E5515C. A power supplier was connected as primary
 voltage supply. Only the mid channel of each frequency band was investigated.



 Limits:

                Tx Frequency                  Channel                          Limit
                 836.49 MHz                      384                +/- 2.5 ppm (+/- 2091 Hz)
                  1880 MHz                       600                +/- 2.5 ppm (+/-4700 Hz)




© 2013 Comptest Services LLC                        Page 22 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                                               Applicant:
                                                                                                  FCC ID:
                                                                                                                Kyocera
                                                                                                                V65C5215
                                             Services LLC                                        Report #:      CT-C5215-22_24-0413-R0


     12.2 Test Result
                                                                         CDMA 800
                                                     Deviation of Carrier (Hz)                 Specification (Hz)
                                     C e
                                  ( o t ur
                                       )           3.3V
                                                                                                                            Result
                                    ra


                                                                            4.2V
                                  pe



                                                 (Battery      3.7V                        Lower limit        Upper limit
                                                                           (115%)
             m
           Te




                                                endpoint)
                                   -30                           -8.02                        -2091              2091
                                   -20                           -7.88                        -2091              2091
                                   -10                           -8.08                        -2091              2091
                                    0                            -7.59                        -2091              2091
                                   10                            -8.22                        -2091              2091
                                                                                                                            Pass
                                   20             -8.50          -9.20        -8.31           -2091              2091
                                   30                            -8.37                        -2091              2091
                                   40                            -8.89                        -2091              2091
                                   50                            -8.40                        -2091              2091
                                   60                            -9.56                        -2091              2091



                                         CDMA 800 MHz Transmitter RF Carrier Stability
                                               Over Temperature and Voltage

                                   3000

                                   2000
           Frequency Error (Hz)




                                   1000

                                         0

                                  -1000

                                  -2000                                                                              3.3V
                                                                                                                     3.7V
                                  -3000
                                                                                                                     4.2V
                                             -30 -20 -10     0      10   20    30     40    50     60
                                                                                                                     Upper Limit
                                                          Temperature (Celsius)
                                                                                                                     Lower Limit




© 2013 Comptest Services LLC                        Page 23 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                                       Applicant:
                                                                                          FCC ID:
                                                                                                        Kyocera
                                                                                                        V65C5215
                                           Services LLC                                  Report #:      CT-C5215-22_24-0413-R0



                                                                    CDMA 1900
                                                   Deviation of Carrier (Hz)            Specification (Hz)
                                 C e
                              ( o t ur
                                                 3.3V
                                   )                                                                                Result
                                ra

                                                                          4.2V
                              pe



                                               (Battery      3.7V                  Lower limit        Upper limit
                                                                         (115%)
             m
           Te




                                              endpoint)
                                   -30                       7.81                      -4700             4700
                                   -20                       6.92                      -4700             4700
                                   -10                       6.91                      -4700             4700
                                    0                        7.54                      -4700             4700
                                   10                        6.35                      -4700             4700
                                                                                                                    Pass
                                   20           7.68         6.45          7.24        -4700             4700
                                   30                        6.99                      -4700             4700
                                   40                        7.44                      -4700             4700
                                   50                        7.52                      -4700             4700
                                   60                        8.10                      -4700             4700



                                         CDMA1900 MHz Transmitter RF Carrier Stability
                                               Over Temperature and Voltage

                                    6000
                                    5000
            Frequency Error (Hz)




                                    4000
                                    3000                                                                     3.3V
                                    2000
                                                                                                             3.7V
                                    1000
                                       0                                                                     4.2V
                                   -1000
                                                                                                             Upper Limit
                                   -2000
                                   -3000                                                                     Lower Limit
                                   -4000
                                   -5000
                                   -6000
                                            -30 -20 -10     0    10   20     30   40   50      60
                                                        Temperature (Celsius)




© 2013 Comptest Services LLC                        Page 24 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


          COMPTEST                                                      Applicant:
                                                                         FCC ID:
                                                                                     Kyocera
                                                                                     V65C5215
                       Services LLC                                     Report #:    CT-C5215-22_24-0413-R0



13      EXPOSURE OF HUMANS TO RF FIELDS (SAR)

  13.1 Test Configuration and Result
     FCC: § 2.1093
       IC: RSS102
  The SAR test report is attached in a separate attachment.




14      TEST EQUIPMENT

The test equipment utilized to perform the tests documented in this report has been calibrated in
accordance with the manufacturer’s recommendations and is traceable to recognized national standards.

  Description                       Manufacturer          Model No.           Serial No.           Cal Due
                                                                                                    Date
  Power Meter                      Giga-tronics          8541C                 1831306            05/16/13
  Spectrum Analyzer                Agilent               E4405B              US41441217           12/11/13
  Wireless
                          Agilent                        8960                GB44052789           12/02/13
  Communications Test Set
                                                         ZH2-033-033-
  Temperature Chamber              Test Equity                                ZZ9622421           08/03/13
                                                         H/AC




© 2013 Comptest Services LLC                        Page 25 of 25                                     EMC Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.



Document Created: 2013-04-19 11:32:23