HAC RF Validation plots

FCC ID: V65C5215

Test Report

Download: PDF
FCCID_1969570

                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5215
                                                                       Report #:    CT- C5215-12B-0313


EXHIBIT 12 Appendix B: HAC RF VALIDATION PLOTS




© 2013 Comptest Services LLC                          Page 1 of 6                           SAR Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                        Applicant:   Kyocera
                                                                         FCC ID:     V65C5215
                                                                        Report #:    CT- C5215-20RFB-0313-R0


Validation E Field Probe SN2341, Dipole SN1015, 835MHz                          Date: 03/25/2013

C5215_Dual_ E_Dipole_835
Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1000 kg/m
                                                                         3

Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: ER3DV6 - SN2341, ConvF(1, 1, 1), Calibrated: 9/14/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn527,Calibrated: 7/30/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:Room T = 21.8         1 deg C, Liquid T = 22.0     1 deg C

E Scan 835 - measurement distance from the probe sensor center to CD835 Dipole =
10mm/Hearing Aid Compatibility Test (41x361x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 159.1 V/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 160.7 V/m; Power Drift = -0.176 dB
Hearing Aid Near-Field Category: M4 (AWF 0 dB)

                                    Peak E-field in V/m
                                     Grid 1   Grid 2   Grid 3
                                     144.8 M4 154.8 M4 153.6 M4
                                     Grid 4    Grid 5     Grid 6
                                     83.3 M4   91.3 M4    91.0 M4
                                     Grid 7   Grid 8   Grid 9
                                     144.3 M4 159.1 M4 157.8 M4




                                  0 dB = 159.1V/m


© 2013 Comptest Services LLC                          Page 2 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                    COMPTEST
                                    Services LLC

                                                                                E(roll)
                                                E_tot; ; E—Field Max Isotropy Error =+0.54 dB;
     200
     180
     160
     140                                                                                             /



     120
    £100
      80
      60
      40
      20




[          6rrer n neperne d   brvey weve n vepuer uevrvevevene vervarvepeed in rorverig   on en e


                                                                        Applicant:   Kyocera
                                                                         FCC ID:     V65C5215
                                                                        Report #:    CT- C5215-20RFB-0313-R0

Validation E Field Probe SN2341, Dipole SN1015, 1900MHz                         Date: 03/25/2013

C5215_Dual_E_Dipole_1880
Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1000 kg/m
                                                                         3

Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: ER3DV6 - SN2341, ConvF(1, 1, 1), Calibrated: 9/14/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn527,Calibrated: 7/30/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:Room T = 21.8         1 deg C, Liquid T = 22.0     1 deg C

E Scan 1880 - measurement distance from the probe sensor center to CD1880 Dipole =
10mm/Hearing Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 136.7 V/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 133.5 V/m; Power Drift = 0.050 dB
Hearing Aid Near-Field Category: M2 (AWF 0 dB)

                                    Peak E-field in V/m
                                     Grid 1   Grid 2   Grid 3
                                     130.9 M2 136.7 M2 133.9 M2
                                     Grid 4    Grid 5     Grid 6
                                     85.8 M3   91.5 M3    90.7 M3
                                     Grid 7   Grid 8   Grid 9
                                     127.5 M2 134.9 M2 132.8 M2




                                 0 dB = 136.7V/m



© 2013 Comptest Services LLC                          Page 4 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:   Kyocera
                                                                          FCC ID:     V65C5215
                                                                         Report #:    CT- C5215-20RFB-0313-R0

Validation H Field Probe SN6123, Dipole SN1015, 835MHz                          Date: 03/25/2013

C5215_Dual_ H_Dipole_835
Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1 kg/m
                                                                     3

Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: H3DV5 - SN6029, , Calibrated: 9/14/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn527,Calibrated: 7/30/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:Room T = 21.8         1 deg C, Liquid T = 22.0     1 deg C

H Scan - measurement distance from the probe sensor center to CD835 Dipole = 10mm/Hearing
Aid Compatibility Test (41x361x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 0.448 A/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 0.507 A/m; Power Drift = -0.062 dB
Hearing Aid Near-Field Category: M4 (AWF 0 dB)

                                    Peak H-field in A/m
                                     Grid 1   Grid 2   Grid 3
                                     0.376 M4 0.388 M4 0.372 M4
                                     Grid 4   Grid 5   Grid 6
                                     0.425 M4 0.448 M4 0.434 M4
                                     Grid 7   Grid 8   Grid 9
                                     0.374 M4 0.381 M4 0.374 M4




                                  0 dB = 0.448A/m




© 2013 Comptest Services LLC                          Page 5 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:   Kyocera
                                                                          FCC ID:     V65C5215
                                                                         Report #:    CT- C5215-20RFB-0313-R0

Validation H Field Probe SN6123, Dipole SN1015, 1900MHz                         Date: 03/25/2013

C5215_Dual_H_Dipole_1880
Communication System: CW, Frequency: 1800 MHz, Duty Cycle: 1:1
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1 kg/m
                                                                     3

Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: H3DV5 - SN6029, , Calibrated: 9/14/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn527,Calibrated: 7/30/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:Room T = 21.8         1 deg C, Liquid T = 22.0     1 deg C

H Scan - measurement distance from the probe sensor center to CD1880 Dipole = 10mm/Hearing
Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 0.470 A/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 0.514 A/m; Power Drift = -0.032 dB
Hearing Aid Near-Field Category: M2 (AWF 0 dB)

                                    Peak H-field in A/m
                                     Grid 1   Grid 2   Grid 3
                                     0.414 M2 0.444 M2 0.428 M2
                                     Grid 4   Grid 5   Grid 6
                                     0.442 M2 0.470 M2 0.457 M2
                                     Grid 7   Grid 8   Grid 9
                                     0.393 M2 0.416 M2 0.410 M2




                                  0 dB = 0.470A/m



© 2013 Comptest Services LLC                          Page 6 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.



Document Created: 2013-04-22 13:16:25
Document Modified: 2013-04-22 13:16:25

© 2024 FCC.report