                   EXHIBIT 9 APPENDIX B3: SAR DISTRIBUTION PLOTS (HOTSPOT)


                                                   PCS




© 2012 Comptest Services LLC                         Page 1 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Front Ch. 600
Communication System: CDMA-1900, Frequency: 1880 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M1800,Medium parameters used: f = 1880 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch600 FLAT - Closed FRONT/Area Scan (61x101x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.688 mW/g

CDMA-1900 Ch600 FLAT - Closed FRONT/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 11.9 V/m; Power Drift = -0.005 dB
Peak SAR (extrapolated) = 0.994 W/kg

SAR(1 g) = 0.607 mW/g; SAR(10 g) = 0.361 mW/g
Maximum value of SAR (measured) = 0.662 mW/g




                                    0 dB = 0.688mW/g




© 2012 Comptest Services LLC                         Page 2 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Back Ch. 25
Communication System: CDMA-1900, Frequency: 1851.25 MHz, Duty Cycle: 1:1
Medium: M1800,Medium parameters used (interpolated): f = 1851.25 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000
     3
kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch25 FLAT - Closed BACK/Area Scan (61x101x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 1.04 mW/g

CDMA-1900 Ch25 FLAT - Closed BACK/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 10.8 V/m; Power Drift = 0.025 dB
Peak SAR (extrapolated) = 1.58 W/kg

SAR(1 g) = 0.955 mW/g; SAR(10 g) = 0.564 mW/g
Maximum value of SAR (measured) = 1.03 mW/g




                                 0 dB = 1.04mW/g




© 2012 Comptest Services LLC                         Page 3 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Back Ch. 600
Communication System: CDMA-1900, Frequency: 1880 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M1800,Medium parameters used: f = 1880 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch600 FLAT - Closed BACK/Area Scan (61x101x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.999 mW/g

CDMA-1900 Ch600 FLAT - Closed BACK/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 10.8 V/m; Power Drift = 0.182 dB
Peak SAR (extrapolated) = 1.52 W/kg

SAR(1 g) = 0.917 mW/g; SAR(10 g) = 0.543 mW/g
Maximum value of SAR (measured) = 0.999 mW/g




                                    0 dB = 0.999mW/g




© 2012 Comptest Services LLC                         Page 4 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                   COMPTEST
                                                                         Services LLC


                                                                                  Interpolated SAR(x.y.z.f0)
                                                                                  SAR: Z Scan: Value Along Z, X=0, Y=0
        rerfmmmrmmmr mm mm mendrnne brmeerme mondrmne on rmne mc




  1.2
  14
  1.0
  0.9
  0.8
  0.7
                                                                   L+—




€o.6
  0.5
  0.4
  0.3
  0.2
  0.1
  0.0


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Back Ch. 1175
Communication System: CDMA-1900, Frequency: 1908.75 MHz, Duty Cycle: 1:1
Medium: M1800,Medium parameters used (interpolated): f = 1908.75 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000
     3
kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch1175 FLAT - Closed BACK/Area Scan (61x101x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 1.16 mW/g

CDMA-1900 Ch1175 FLAT - Closed BACK/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 13.2 V/m; Power Drift = -0.134 dB
Peak SAR (extrapolated) = 1.79 W/kg

SAR(1 g) = 1.06 mW/g; SAR(10 g) = 0.638 mW/g
Maximum value of SAR (measured) = 1.16 mW/g




                                    0 dB = 1.16mW/g




© 2012 Comptest Services LLC                         Page 6 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Left Ch. 600
Communication System: CDMA-1900, Frequency: 1880 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M1800,Medium parameters used: f = 1880 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch600 FLAT - Left /Area Scan (91x51x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.252 mW/g

CDMA-1900 Ch600 FLAT - Left /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 12.8 V/m; Power Drift = 0.068 dB
Peak SAR (extrapolated) = 0.374 W/kg

SAR(1 g) = 0.235 mW/g; SAR(10 g) = 0.144 mW/g
Maximum value of SAR (measured) = 0.256 mW/g




                                  0 dB = 0.252mW/g




© 2012 Comptest Services LLC                         Page 7 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


              COMPTEST                                        n
                  Services LLC


                           Interpolated SAR(x.y.z.f0)
                           SAR: Z Scan: Value Along Z, X=0, Y=0



     0.25 —   %



     0.20



     0.15
mW




     0.10         \



     0.05             \


     0.00                 [~toeemotleby                           cgcctlorca.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Right Ch. 600
Communication System: CDMA-1900, Frequency: 1880 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M1800,Medium parameters used: f = 1880 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch600 FLAT - Right /Area Scan (101x51x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.248 mW/g

CDMA-1900 Ch600 FLAT - Right /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 10.6 V/m; Power Drift = -0.053 dB
Peak SAR (extrapolated) = 0.350 W/kg

SAR(1 g) = 0.216 mW/g; SAR(10 g) = 0.129 mW/g
Maximum value of SAR (measured) = 0.235 mW/g




                                 0 dB = 0.248mW/g




© 2012 Comptest Services LLC                         Page 9 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/26/2012

FCC C5170 PCS Flat with 1cm Air Space, Bottom Ch. 600

Communication System: CDMA-1900, Frequency: 1880 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M1800,Medium parameters used: f = 1880 MHz; σ = 1.54 mho/m; εr = 51.9; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3036, ConvF(4.57, 4.57, 4.57), Calibrated: 5/11/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn675,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

CDMA-1900 Ch600 FLAT - Bottom /Area Scan (61x101x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.413 mW/g

CDMA-1900 Ch600 FLAT - Bottom /Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 16.7 V/m; Power Drift = -0.091 dB
Peak SAR (extrapolated) = 0.592 W/kg

SAR(1 g) = 0.372 mW/g; SAR(10 g) = 0.220 mW/g
Maximum value of SAR (measured) = 0.407 mW/g




                                    0 dB = 0.413mW/g




© 2012 Comptest Services LLC                        Page 10 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0


                                                   WIFI




© 2012 Comptest Services LLC                        Page 11 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                      Date: 03/22/2012

FCC C5170 WIFI Flat with 1cm Air Space, Front Ch. 11
Communication System: WLAN-2450, Frequency: 2462 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M2450,Medium parameters used: f = 2500 MHz; σ = 1.98 mho/m; εr = 50.4; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3078, ConvF(4.16, 4.16, 4.16), Calibrated: 9/19/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn530,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

WLAN Ch11 FLAT - Face Up/Area Scan (61x91x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.300 mW/g

WLAN Ch11 FLAT - Face Up/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 0.761 V/m; Power Drift = -0.121 dB
Peak SAR (extrapolated) = 0.470 W/kg

SAR(1 g) = 0.087 mW/g; SAR(10 g) = 0.022 mW/g
Maximum value of SAR (measured) = 0.246 mW/g




                                   0 dB = 0.300mW/g




© 2012 Comptest Services LLC                        Page 12 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/22/2012

FCC C5170 WIFI Flat with 1cm Air Space, Back Ch. 11
Communication System: WLAN-2450, Frequency: 2462 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M2450,Medium parameters used: f = 2500 MHz; σ = 1.98 mho/m; εr = 50.4; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3078, ConvF(4.16, 4.16, 4.16), Calibrated: 9/19/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn530,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

WLAN Ch11 FLAT - Face Down/Area Scan (61x91x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.086 mW/g

WLAN Ch11 FLAT - Face Down/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 2.49 V/m; Power Drift = 0.167 dB
Peak SAR (extrapolated) = 0.223 W/kg
SAR(1 g) = 0.062 mW/g; SAR(10 g) = 0.026 mW/g
Maximum value of SAR (measured) = 0.212 mW/g

WLAN Ch11 FLAT - Face Down/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 2.49 V/m; Power Drift = 0.167 dB
Peak SAR (extrapolated) = 0.275 W/kg
SAR(1 g) = 0.105 mW/g; SAR(10 g) = 0.052 mW/g
Maximum value of SAR (measured) = 0.141 mW/g




                                  0 dB = 0.141mW/g




© 2012 Comptest Services LLC                        Page 13 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                 COMPTEST                                                                                     n
                                      Services LLC


                                                             Interpolated SAR(x.y.z.f0)
                                                         SAR: Z Scan: Value Along Z, X=0, Y=0

     0.30——        X

     0.25——        \

     0.20——
                   |__—
         mm




a
30.
     o

          in
mW




                          /




     0.10
                             /




     0.05——                          \


     asl                                 ___]nemmboanpoh.
            7\          11       _          1__   _          1_(_4          1__   _          11   _4          1_1_4          11   _          1_1_4

                 0.00                0.02             0.04           0.06             0.08             0.10           0.12            0.14           0.16
                                                                                      m


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/22/2012

FCC C5170 WIFI Flat with 1cm Air Space, Left Ch. 11
Communication System: WLAN-2450, Frequency: 2462 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M2450,Medium parameters used: f = 2500 MHz; σ = 1.98 mho/m; εr = 50.4; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3078, ConvF(4.16, 4.16, 4.16), Calibrated: 9/19/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn530,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

WLAN Ch11 FLAT -Left/Area Scan (61x91x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.088 mW/g

WLAN Ch11 FLAT -Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.22 V/m; Power Drift = 0.017 dB
Peak SAR (extrapolated) = 0.718 W/kg
SAR(1 g) = 0.017 mW/g; SAR(10 g) = 0.00586 mW/g
Maximum value of SAR (measured) = 0.219 mW/g

WLAN Ch11 FLAT -Left/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.22 V/m; Power Drift = 0.017 dB
Peak SAR (extrapolated) = 0.041 W/kg
SAR(1 g) = 0.00444 mW/g; SAR(10 g) = 0.000982 mW/g
Maximum value of SAR (measured) = 0.027 mW/g




                                  0 dB = 0.088mW/g




© 2012 Comptest Services LLC                        Page 15 of 17                                SAR Plots Head
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


              COMPTEST
                              Services LLC


                                        Interpolated SAR(x.y.z.f0)
                                        SAR: Z Scan: Value Along Z, X=0, Y=0
     0.16


     0.14       k

     0.12       ‘&




                     \
     0.10 E         fl%

     0.08
                    |_—
mW


         mm




     0.06——               \

     0.04——

     0.02
     0.00 F                                  /M‘\\                                    /\

     —0.02
              0.00            0.02   0.04       0.06       0.08        0.10    0.12   0.14   0.16


                                                                         Applicant:Kyocera
                                                                          FCC ID:  OVF-C5170
                                                                               IC#:3572A- C5170
                                                                         Report #: CT- C5170-9B3-0312-R0

Test Laboratory: Comptest/Kyocera                                                              Date: 03/22/2012

FCC C5170 WIFI Flat with 1cm Air Space, Bottom Ch. 11
Communication System: WLAN-2450, Frequency: 2462 MHz, Duty Cycle: 1:1
                                                                                             3
Medium: M2450,Medium parameters used: f = 2500 MHz; σ = 1.98 mho/m; εr = 50.4; ρ = 1000 kg/m
Phantom: SAM 12,Phantom section: Flat Section
DASY4 Configuration:
Probe: ES3DV3 - SN3078, ConvF(4.16, 4.16, 4.16), Calibrated: 9/19/2011
Sensor-Surface: 4mm (Mechanical Surface Detection),
Electronics: DAE4 Sn530,Calibrated: 5/5/2011
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

WLAN Ch11 FLAT -Bottom/Area Scan (71x51x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (interpolated) = 0.095 mW/g

WLAN Ch11 FLAT -Bottom/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.20 V/m; Power Drift = 0.123 dB
Peak SAR (extrapolated) = 0.481 W/kg
SAR(1 g) = 0.101 mW/g; SAR(10 g) = 0.027 mW/g
Maximum value of SAR (measured) = 0.273 mW/g

WLAN Ch11 FLAT -Bottom/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.20 V/m; Power Drift = 0.123 dB
Peak SAR (extrapolated) = 0.290 W/kg
SAR(1 g) = 0.030 mW/g; SAR(10 g) = 0.00917 mW/g
Maximum value of SAR (measured) = 0.163 mW/g




                                  0 dB = 0.095mW/g




© 2012 Comptest Services LLC                        Page 17 of 17                                SAR Plots Head