Validation E Field Probe SN2341, Dipole SN1015, 835MHz                          Date: 07/23/2012

C5156_Dual_E_Dipole_835
Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1
                                                                       3
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1000 kg/m
Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: ER3DV6 - SN2282, ConvF(1, 1, 1), Calibrated: 2/17/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn675,Calibrated: 5/23/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8                          22.0

E Scan 835 - measurement distance from the probe sensor center to CD835 Dipole = 10mm/Hearing Aid
Compatibility Test (41x361x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 163.2 V/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 182.1 V/m; Power Drift = -0.231 dB
Hearing Aid Near-Field Category: M4 (AWF 0 dB)

                                    Peak E-field in V/m
                                     Grid 1   Grid 2   Grid 3
                                     153.7 M4 163.2 M4 155.3 M4
                                     Grid 4    Grid 5     Grid 6
                                     84.2 M4   86.7 M4    83.4 M4
                                     Grid 7   Grid 8   Grid 9
                                     142.2 M4 162.7 M4 161.6 M4




                                  0 dB = 163.2V/m


© 2012 Comptest Services LLC                          Page 1 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


             COMPTEST                                                            —         '
                         Services LLC                                            l s

                                                  E(roll)
                                E_tot; ; E—Field Max Isotropy Error =+0.70 dB;
   200

   180
         [                                                    —+—w—i*~                 _a—+—+—s_]
   180 |—    C                                      /                      pre                      *—.




   140

   120

 3
 5100

    80

    60

    40

    20




[' | L ie boprorneuieeroeaebopervererie urtvufet ie rep renurvanuie eriiivee verreuin un evrnigesvee werrreveemen '"W


                                                                        Applicant:   Kyocera
                                                                         FCC ID:     V65C5155
                                                                        Report #:    CT-C5156-20RFB-0712-R0

Validation E Field Probe SN2341, Dipole SN1015, 1900MHz                         Date: 07/23/2012

C5156_E_Dipole_1880
Communication System: CW, Frequency: 1900 MHz, Duty Cycle: 1:1
                                                                       3
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1000 kg/m
Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: ER3DV6 - SN2282, ConvF(1, 1, 1), Calibrated: 2/17/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn675,Calibrated: 5/23/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8                          22.0

E Scan 1880 - measurement distance from the probe sensor center to CD1880 Dipole = 10mm/Hearing
Aid Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 141.2 V/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 153.9 V/m; Power Drift = 0.119 dB
Hearing Aid Near-Field Category: M2 (AWF 0 dB)

                                    Peak E-field in V/m
                                     Grid 1   Grid 2   Grid 3
                                     125.7 M2 131.1 M2 128.7 M2
                                     Grid 4    Grid 5     Grid 6
                                     83.5 M3   85.4 M3    82.6 M3
                                     Grid 7   Grid 8   Grid 9
                                     131.9 M2 141.2 M2 138.5 M2




                                 0 dB = 141.2V/m


© 2012 Comptest Services LLC                          Page 3 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


            COMPTEST                                                             —       '
                         Services LLC                                            l s

                                                  E(roll)
                                E_tot; ; E—Field Max Isotropy Error =+0.95 dB;
   200

   180

   160




   120                                                     zi+

 3
 5100

    80

    60

    40

    20




[' | L ie boprorneuieeroeaeboperverervine urivufet ie rep reurianuie eriivre verreuin un evrnigeson werrreveemen '"W


                                                                        Applicant:   Kyocera
                                                                         FCC ID:     V65C5155
                                                                        Report #:    CT-C5156-20RFB-0712-R0

Validation H Field Probe SN6029, Dipole SN1015, 835MHz                          Date: 07/23/2012

C5156_Dual_ H_Dipole_835
Communication System: CW, Frequency: 835 MHz, Duty Cycle: 1:1
                                                                    3
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1 kg/m
Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: H3DV6 - SN6123, , Calibrated: 2/17/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn675,Calibrated: 5/23/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

H Scan - measurement distance from the probe sensor center to CD835 Dipole = 10mm/Hearing Aid
Compatibility Test (41x361x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 0.481 A/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 0.526 A/m; Power Drift = 0.155 dB
Hearing Aid Near-Field Category: M4 (AWF 0 dB)

                                    Peak H-field in A/m
                                     Grid 1   Grid 2   Grid 3
                                     0.413 M4 0.421 M4 0.382 M4
                                     Grid 4   Grid 5   Grid 6
                                     0.470 M4 0.481 M4 0.447 M4
                                     Grid 7   Grid 8   Grid 9
                                     0.411 M4 0.423 M4 0.395 M4




                                  0 dB = 0.481A/m



© 2012 Comptest Services LLC                          Page 5 of 6                        HAC RF Validation Plots
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                        Applicant:   Kyocera
                                                                         FCC ID:     V65C5155
                                                                        Report #:    CT-C5156-20RFB-0712-R0

Validation H Field Probe SN6029, Dipole SN1015, 1900MHz                         Date: 07/23/2012

C5156_H_Dipole_1880
Communication System: CW, Frequency: 1800 MHz, Duty Cycle: 1:1
                                                                    3
Medium: Air,Medium parameters used: σ = 0 mho/m, εr = 1; ρ = 1 kg/m
Phantom: HAC Test Arch with AMCC,Phantom section: RF Section
DASY4 Configuration:
Probe: H3DV6 - SN6123, , Calibrated: 2/17/2012
Sensor-Surface: (Fix Surface),
Electronics: DAE4 Sn675,Calibrated: 5/23/2012
Measurement SW: DASY4, V4.7 Build 80
Postprocessing SW: SEMCAD, V1.8 Build 186
Temperature:
Room T = 21.8 +/- 1 deg C, Liquid T = 22.0 +/- 1 deg C

H Scan - measurement distance from the probe sensor center to CD1880 Dipole = 10mm/Hearing Aid
Compatibility Test (41x181x1): Measurement grid: dx=5mm, dy=5mm
Maximum value of peak Total field = 0.477 A/m
Probe Modulation Factor = 1.00
Device Reference Point: 0.000, 0.000, -6.30 mm
Reference Value = 0.528 A/m; Power Drift = -0.034 dB
Hearing Aid Near-Field Category: M2 (AWF 0 dB)

                                    Peak H-field in A/m
                                     Grid 1   Grid 2   Grid 3
                                     0.425 M2 0.440 M2 0.415 M2
                                     Grid 4   Grid 5   Grid 6
                                     0.461 M2 0.477 M2 0.450 M2
                                     Grid 7   Grid 8   Grid 9
                                     0.418 M2 0.434 M2 0.407 M2




                                  0 dB = 0.477A/m



© 2012 Comptest Services LLC                          Page 6 of 6                        HAC RF Validation Plots