HAC RF report

FCC ID: V65C5155

Test Report

Download: PDF
FCCID_1783402

                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0




                            Hearing Aid Compatibility (HAC)
                                    RF Emissions

                                   FCC 47 CFR Part 20.19

                                              Test Report

                                                     For

                                Kyocera Corporation
                          c/o Kyocera Communications, Inc.




                               Product:            Dual-Band CDMA Phone
                                Model:                     C5156




© 2012 Comptest Services LLC                         Page 1 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                                             Applicant:       Kyocera
                                                                                              FCC ID:         V65C5155
                                                                                             Report #:        CT-C5156_20RF-0712-R0

                                                        TABLE OF CONTENTS

1     SUMMARY OF TESTING ................................................................................................................. 4
2     EQUIPMENT UNDER TEST INFORMATION ................................................................................... 4
3     TEST CONDITIONS ......................................................................................................................... 5
    3.1     AMBIENT CONDITIONS ................................................................................................................. 5
    3.2     RF CHARACTERISTICS OF THE TEST SITE ...................................................................................... 5
    3.3     TEST SIGNAL, FREQUENCIES AND OUTPUT POWER ....................................................................... 5
    3.4     EUT OPERATING CONDITIONS ..................................................................................................... 6
4     DESCRIPTION OF TEST EQUIPMENT ........................................................................................... 7
    4.1     TEST EQUIPMENT USED .............................................................................................................. 7
    4.2     NEAR FIELD MEASUREMENT SYSTEM ........................................................................................... 7
    4.3     ISOTROPIC E-FIELD PROBE ......................................................................................................... 8
    4.4     ISOTROPIC -FIELD PROBE ............................................................................................................ 8
5     SYSTEM VALIDATION .................................................................................................................... 9
    5.1     DIPOLE VALIDATION SETUP ......................................................................................................... 9
    5.2     DIPOLE VALIDATION RESULTS .................................................................................................... 10
6     DESCRIPTION OF TEST PROCEDURE ........................................................................................ 11
    6.1     TEST POSITIONS ....................................................................................................................... 11
    6.2     RF EMISSION MEASUREMENTS REFERENCE AND PLANE ............................................................. 11
    6.3     RF EMISSIONS MEASUREMENT PROCEDURES ............................................................................ 12
7     PROBE MODULATION FACTOR (PMF)........................................................................................ 13
    7.1     PMF MEASUREMENT PROCEDURES ........................................................................................... 13
    7.2     PMF TEST RESULTS ................................................................................................................. 14
    7.3     PMF PEAK POWER MEASUREMENT PLOTS ................................................................................. 15
8     EMISSION DATA EXTRACTION AND POSTPROCESSING ......................................................... 17
9     MEASUREMENT UNCERTAINTY.................................................................................................. 18
10    RF EMISSIONS TESTS .................................................................................................................. 19
    10.1    EMISSION LIMITS ....................................................................................................................... 19
    10.2    CDMA 800 BC-0 TEST RESULTS ............................................................................................... 20
    10.3    CDMA 1900 TEST RESULTS...................................................................................................... 21
    10.4    WORST-CASE CONFIGURATION EVALUATION .............................................................................. 22
11    APPENDIX A: PROBE CALIBRATION CERTIFICATION .............................................................. 23
12    APPENDIX B: SYSTEM VALIDATION DATA PLOTS ................................................................... 23
13    APPENDIX C: TEST RESULTS/PLOTS ........................................................................................ 23
14    APPENDIX D: PHOTO TEST SETUP ............................................................................................ 23




© 2012 Comptest Services LLC                         Page 2 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0




                                             ATTESTATION

 The tested device complies with the requirements in respect of all parameters subject to the test.
 The test results and statements relate only to the items tested.
 The test equipment used was suitable for the tests performed and within manufacturer’s published
 specifications and operating parameters.
 The test methods were consistent with the methods described in the relevant standards.

                           Product: Dual-Band CDMA Mobile Phone with Bluetooth and WLAN

                           Model #: C5156

                            FCC ID: V65C5155

      Tested in accordance with: FCC 47 CFR Part 20.19
                                 ANSI C63.19-2007
               Test performed by: Comptest Services LLC

              Test Requested by: KYOCERA Corporation
                                 C/o KYOCERA Communications, Inc.
                                 8611 Balboa Ave.
                                 San Diego, CA 92123 United States
                      Date of Test: July 23, 2012




    Responsible Engineer                                           Reviewed and approved by:



    Benjamin Nguyen
    Benjamin Nguyen                                                Tammy To
    Test Engineer                                                  Quality Manager




© 2012 Comptest Services LLC                         Page 3 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:    Kyocera
                                                                       FCC ID:      V65C5155
                                                                      Report #:     CT-C5156_20RF-0712-R0



1       SUMMARY OF TESTING

Rule Part                                      Test Description                Section #           Verdict
FCC § 20.19(b), §6.3(v), §7.3(v)               HAC RF Emissions                      4              Pass

                                    ANSI C63.19-2007 HAC M Category:                         M4




2       EQUIPMENT UNDER TEST INFORMATION

                    Product: Dual-Band CDMA Cellular Phone with Bluetooth and WLAN
                     FCC ID: V65C5155
            Model Number: C5156
       EUT Serial Number: 268435457816727799
                       Type: [ ] Identical Prototype,
                             [X] Pre-Production,
                             [ ] Production
          Device Category: Portable
              RF Exposure General Population / Uncontrolled
              Environment:
                   Antenna: Internal
      Detachable Antenna: Yes
             External Input: Audio/Digital Data
                   Quantity: Quantity production is planned
                       Mode:                   CDMA                                      CDMA
                                         1X & EvDo Rev0, A                         1x & EvDo Rev0, A
                       Band:                    BC-0                                     BC-1
      TX Frequency (MHz):                   824.7 -848.3                              1850 -1910




© 2012 Comptest Services LLC                         Page 4 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



3       TEST CONDITIONS

 3.1       Ambient Conditions
    All tests were performed under the following environmental conditions:
    Ambient Temperature:                        23 ± 2 Degrees C
    Tissue simulating liquid temperature:       22 ± 1 Degrees C
    Relative Humidity (RH):                     0% <RH < 80%
    Atmospheric Pressure:                       101.3kPa + 10 to –5 kPa

 3.2       RF characteristics of the test site
    All HAC measurements were performed inside a shielded room that provide isolation from external
    EM fields, with the RF ambient at least 20 dB below the intended measurement limits.

 3.3       Test Signal, Frequencies and Output Power
    The device supports CDMA2000 in 1X (Phase I, Protocol revision 6) mode only. CDMA2000 1X
    includes TIA/EIA-95B as a subset and was approved for publishing in July 1999. It provides voice
    and data capabilities within a standard 1.25 MHz CDMA channel. This RF bandwidth is identical to
    the legacy IS-95 B system standard.

    Peak and Average conducted power were measured to ensure worst case power configuration was
    tested:

              CONFIGURATION                                     CONDUCTED POWER
                 (Full Rate)                     CDMA 800 BC-0                      CDMA 1900
                                                    (ch 384)                          (ch 600)
                                                 Average (dBm)                     Average (dBm)
       SO2          RC1                                 24.80                           24.62
                    RC3                                 24.85                           24.56
       SO55         RC1                                 24.75                           24.70
                    RC3                                 24.75                           24.72
       SO32         RC3 (+F-SCH)                        24.70                           24.69
                    RC3 (+SCH)                          24.80                           24.69

    In all operating modes, the phone was set to rated maximum RF power level and the
    measurements were performed on low, mid and high channels.


    The measurement system measures power drift during HAC testing by comparing E/H-field in the
    same location at the beginning and at the end of measurement. These records were used to
    monitor stability of power output during tests. Conducted RF power measurements were also
    performed before and after each HAC measurements to confirm the output power.




© 2012 Comptest Services LLC                         Page 5 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0




   During tests, the EUT was put in in-call mode and controlled by a CDMA simulator to generate the
   required signal and power:

   Protocol:                                      6 (IS-2000)
   Radio Configuration:                           3
   Power Control:                                 All Up Bits
   Service Option:                                55
   Data Rate:                                     Full



 3.4      EUT Operating Conditions
   The EUT was tested with the follow configurations and conditions, if applicable:

     X Fully charged standard battery as supplied with the handset
       Closed configurations at ear use position 1
       Both retracted and extended antenna positions
     X Back-light always ON
       Simultaneous transmission with Bluetooth transmitter ON 2

   Note: *The Bluetooth transmitter was not enable during tests, since the intended use of the CDMA
   transmitter does not include support simultaneous operation when held to ear.




© 2012 Comptest Services LLC                         Page 6 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



4         DESCRIPTION OF TEST EQUIPMENT

    4.1     Test Equipment Used
    Below is a list of the calibrated equipment used for the measurements.
    The calibration certificates of E-field and H-field probes are attached in Appendix A.
    Description                      Manufacturer           Model        Serial Number        Cal Due Date
                                                           Number
    Power Meter                      Giga-tronics        8541C          1831306              02/24/13
    Signal Generator                 Hewlett Packard     E4421B         US38440337           06/28/13
    Radio Communication Tester       Agilent             8960           GB44052789           02/24/14
    Data Acquisition                 Speag               DAE4           675                  05/23/13
    E-field Probe                    Speag               ER3DV6         2282                 02/17/13
    H-field Probe                    Speag               H3DV5          6123                 02/17/13
    Dipole Antenna (835MHz)          Speag               CD835V3        1020                 03/08/13
    Dipole Antenna (1880MHz)         Speag               CD1880V3 1015                    03/08/13
    Note: Dipoles are calibrated on a 2-year interval. Dipoles return-loss and input impedances are
    measured annually (50824 DO2 Dipole SAR Validation Verification v01).

 4.2        Near Field Measurement System
    The measurements were performed with Dasy4 automated near-field scanning system comprised
    of high precision robot, robot controller, computer, near-field probe, probe alignment sensor, non-
    conductive phone positioner, Test Arch and software extension. The overall expanded uncertainty
    (K=2) of the measurement system is 10.9% and 14.7% for H-field and E-field resp. The
    measurement uncertainty budget is given in section 6.




© 2012 Comptest Services LLC                         Page 7 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



 4.3      Isotropic E-Field Probe
   Model                       ER3DV6
   Construction                One dipole parallel, two dipoles normal to probe axis
                               Built-in shielding against static charges
                               PEEK enclosure material (resistant to organic solvents, e.g., glycolether)
   Calibration                 In air from 100 MHz to 3.0 GHz (absolute accuracy ± 6%; k=2)
   Frequency                   100MHz to 6 GHz
                               Linearity: ± 0.2dB (100MHz to 3GHz)
   Directivity                 ± 0.2 dB in air (rotation around probe axis)
                               ± 0.4 dB in air (rotation normal to probe axis)
   Dynamic Range               2 V/m to > 1000 V/m
                               Linearity: ± 0.2 dB
   Dimensions                  Overall length: 330 mm (Tip: 16 mm)
                               Tip diameter: 8 mm (Body: 12 mm)
                               Distance from probe tip to dipole centers: 2.5 mm
   Application                 General near-field measurements up to 6 GHz
                               Field component measurements
                               Fast automatic scanning in phantoms



  4.4 Isotropic -Field Probe
   Model                       H3DV6
   Construction                Three concentric loop sensors with 3.8 mm loop diameters
                               Resistively loaded detector diodes for linear response
                               Built-in shielding against static charges
                               PEEK enclosure material (resistant to organic solvents, e.g., glycolether)
   Frequency                   200 MHz to 3 GHz (± 6.0%, k=2); Output linearized
   Directivity                 ± 0.25 dB (spherical isotropy error)
   Dynamic Range               10 mA/m to 2 A/m at 1 GHz
   E-Field Interference        < 10% at 3 GHz (for plane wave)
   Dimensions                  Overall length: 330 mm (Tip: 40 mm)
                               Tip diameter: 6 mm (Body: 12 mm)
                               Distance from probe tip to dipole centers: 3 mm
   Application                 General magnetic near-field measurements up to 3 GHz
                               Field component measurements
                               Surface current measurements
                               Measurements in air or liquids
                               Low interaction with the measured field




© 2012 Comptest Services LLC                         Page 8 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



5       SYSTEM VALIDATION

 5.1       Dipole Validation Setup
    The probes are calibrated annually by the manufacturer. The HAC measurements of the device
    were done within 24 hours of system accuracy verification, which was done using calibration
    dipoles. Unmodulated continous wave of power level of 20dBm was supplied to a dipole antenna
    placed under Test Arch. The measurement probes are positioned over the illuminated dipole at
    10mm distance from the top surface of the dipole element to the calibration reference point of the
    sensor, defined by the probe manufacturer.




                                        Figure 5 System Check Setup




© 2012 Comptest Services LLC                         Page 9 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



 5.2      Dipole Validation Results
   The length of the dipole was scanned with both E and H-field probes and the maximum values for
   each were recorded. The validation results are in the table below and printouts of the validation
   test are attached in Appendix B. All the measured parameters were within the specification.
    Freq. (MHz)      Parameter         Target       Measured      Delta (%)     Limit (%)       Test date
                                      (SPEAG)
        835          E dB(V/m)          169.7          163.2         -3.83          25          07/23/12
                     H dB(A/m)          0.474          0.481         1.48           25          07/23/12
        1880         E dB(V/m)          143.9          141.2         -1.88          25          07/23/12
                     H dB(A/m)          0.474          0.477         0.55           25          07/23/12




© 2012 Comptest Services LLC                        Page 10 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



6       DESCRIPTION OF TEST PROCEDURE


    6.1 Test Positions
    The device was placed on a non-conductive phone positioner under the Test Arch.



    6.2 RF Emission Measurements Reference and Plane
    Figure 6.2 illustrates the references and reference plane that shall be used in the EUT emissions
    measurement:

     The grid is 5 cm by 5 cm area that is divided into 9 evenly sized blocks or sub-grids.
     The grid is centered on the audio frequency output transducer (speaker) of the EUT.
     The grid is in a reference plane, which is defined as the planar area that contains the highest
      point in the area of the phone that normally rests against the user's ear. It is parallel to the
      centerline of the receiver of the EUT and is defined by the points of the receiver-end of the EUT,
      which, in normal handset use, rest against the ear.
     The measurement plane is parallel to, and 1.5 cm in front of, the reference plane.



                            Vertical centerline of phone

     5 x 5 cm grid

                                    Horizontal centerline of
                                    acoustic output




                                               Measurement plane
                                                                   1.5 cm
                                               Reference plane




                              Figure 6.2 – Measurement Reference and Plane




© 2012 Comptest Services LLC                        Page 11 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:   Kyocera
                                                                          FCC ID:     V65C5155
                                                                         Report #:    CT-C5156_20RF-0712-R0

  6.3 RF Emissions Measurement Procedures
   Flowchart below shows the near field emission measurement:
   1. The center of the probe was scan to the edges of the grid. Accordingly the total area covered by
      the outside edge of the probe was the 5 cm by 5 cm area, increased by half (½) the probe
      diameter on all sides.
   2. The nearest point on the probe measurement element(s) was held 1.0 cm from the EUT
      reference plane.
   3. The probe element is that portion of the probe that is designed to receive and sense the field
      being measured.
   4. The physical body of the probe housing was not used when setting this 1.0 cm distance as this
      would place the sensing elements at an indeterminate distance from the reference plane.
   5. The step size of the scan is set to 5 mm or less.
   6. Up to three blocks were excluded for each field measurement.
           The center block containing the EUT output was not excluded.
           A maximum of five blocks were excluded for both E- and H-field measurements for the
             EUT output being measured. Stated differently, the center sub-grid or block and 3 other
             blocks were common to both the E- and H-field measurements for a given grid.


                        Confirm proper operation of probes and
                         instrumentation
                        Position EUT in test position
                        Configure EUT TX Operation


                        Initialize field probe and take first reading
                        Scan Area
                        Measure Drift


                        Identify exclusion area and then identify and      Rescan for E or H-Field as
                         record maximum reading in V/m or A/m                needed




                                      All Configurations and
                                         Both E & H Field
                                            Scanned?

                                                    Yes


                          Identify and record Category




                               Figure 7.6 Near field emission measurement flowchart




© 2012 Comptest Services LLC                        Page 12 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0


7         PROBE MODULATION FACTOR (PMF)

    7.1 PMF Measurement Procedures
    A calibration was made of the modulation response of the probe and its instrumentation chain. This
    calibration was performed with the field probe, attached to its instrumentation. The response of the
    probe system to a CW field at the frequency of interest is compared to its response to a modulated
    signal with equal peak amplitude to that of a CW signal. The field level of the test signals shall be
    more than 10 dB above the ambient level and the noise floor of the instrumentation being used. The
    ratio of the CW reading to that taken with a modulated reading was applied to the DUT
    measurements. The measurement procedures are as following:

     1. Fix the field probe in a set location relative to the dipole antenna, as illustrated in Figure 7.4.
     2. Setup the wireless device (EUT) with intended signal at the intended measurement frequency.\
     3. Record the reading of the probe measurement system.
     4. Replace the wireless device with a RF signal generator producing an unmodulated CW signal
        and set to the wireless device operating frequency.
     5. Set the peak power of the unmodulated signal to equal that recorded from the wireless device
     6. Record the reading of the probe measurement system of the unmodulated CW signal.
     7. The ratio of probe reading (CW) in step 6 to the probe reading (EUT) in step 3 is the
        modulation factor.




                                                   Figure 7.4




© 2012 Comptest Services LLC                        Page 13 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0




 7.2      PMF Test Results
  The modulation factors obtained by above method shall be applied to readings taken of the actual
  WD, in order to obtain an accurate peak field reading.
                                                 E-Field
    Frequency        Peak Power         Protocol         Protocol Reading       Modulation Factor
      (MHz)             (dBm)                                 (V/m)
       835               24.32             CW                 127.6
                           24.3         CDMA (full rate)              127.4                     1.00
                          24.32                AM                     77.77                     1.64
        1880              22.92                CW                     69.51
                          22.92         CDMA (full rate)              70.66                     0.98
                          22.92                AM                     44.42                     1.56
                                                  H-Field
     Frequency        Peak Power            Protocol           Protocol Reading         Modulation Factor
       (MHz)            (dBm)                                       (A/m)
        835              24.5                  CW                   0.343
                           24.5         CDMA (full rate)              0.335                     1.02
                          24.61                AM                     0.223                     1.54
        1880              22.92                CW                     0.272
                          22.94         CDMA (full rate)              0.277                     0.98
                          22.92                AM                     0.173                     1.57




© 2012 Comptest Services LLC                        Page 14 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



  7.3 PMF Peak Power Measurement Plots
                                                CDMA-800




                                                      CW




                                                   80% AM




© 2012 Comptest Services LLC                        Page 15 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0

                                                 CDMA-1880




                                                      CW




                                                   80% AM




© 2012 Comptest Services LLC                        Page 16 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



8       EMISSION DATA EXTRACTION AND POSTPROCESSING

 At the end of the measurements, the DASY4 system automatically evaluates the slot-averaged
 results, exclusion of the three highest subgrid, application of the AWF factor per ANSI-C63.19
 requirements.

 The following AWF factors were used for the standard transmission protocols:

         Standard                       Technology                      AWF
      TIA/EIA/IS-2000                      CDMA                           0
        TIA/EIA-136                    TDMA (50 Hz)                       0
         J-STD-007                       GSM (217)                       -5
      T1/T1P1/3GPP                   UMTS (WCDMA)                         0
                TM
           iDEN                    TDMA(22 and 11 Hz)                     0


                               Table 8.1 Articulation Weighting Factor (AWF)

 All DASY4 measurements are in RMS values. The Dasy4 system incorporates the crest factor of the
 signal in the computation of the RMS values. Although the software also has the capability to
 estimate the peak field by applying a square root of the crest factor value to the readings, the probe
 modulation factor was applied manually instead per ANSI C63.19 in the measurement tables in this
 report using equation:

                                 Peak Field = (DASY4 reading) x PMF


         where DASY4 reading = measurement from DASY4 in V/m or A/m
               PMF = Probe Modulation Factor in linear unit




© 2012 Comptest Services LLC                        Page 17 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:     Kyocera
                                                                       FCC ID:       V65C5155
                                                                      Report #:      CT-C5156_20RF-0712-R0


9        MEASUREMENT UNCERTAINTY

 Table 8.1 shows the uncertainty budget for HAC free field assessment according to ANSI C63.19-
 2007. The budget is valid for the frequency range 800 MHz - 3 GHz and represents a worst-case
 analysis. For specific tests and configurations, the uncertainty could be smaller.

      Uncertainty Description       Uncert    Prob    Div.     Ci      Ci     Stand.        Stand.
                                    . Value     .             (E)     (H)    Uncert (E)    Uncert (H)
                                      ( %)   Dist.                            (%)          (%)
    Measurement system
    Probe calibration                5.1        N      1       1      1            5.1         5.1
    Axial isotropy of the probe      4.7        R      √3      1      1            2.7         2.7
    Sensor displacement              16.5       R      √3      1     0.14          9.5         1.4
                                                                      5
    Boundary effects                  2.4       R      √3      1      1            1.4         1.4
    Probe linearity                   4.7       R      √3      1      1            2.7         2.7
    Scaling to Peak Envelope          2.0       R      √3      1      1            1.2         1.2
    Power
    System Detection limit            1.0       R      √3      1      1            0.6         0.6
    Readout electronics               0.3       N      1       1      1            0.3         0.3
    Response time                     0.8       R      √3      1      1            0.5         0.5
    Integration time                  2.6       R      √3      1      1            1.5         1.5
    RF ambient conditions             3.0       R      √3      1      1            1.7         1.7
    RF Reflections                    12        R      √3      1      1            6.9         6.9
    Probe Positioner                  1.2       R      √3      1     0.67          0.7         0.5
    Probe positioning                 4.7       R      √3      1     0.67          2.7         1.8
    Extrap. and integration           1.0       R      √3      1      1            0.6         0.6
    Test Sample Related
    Device positioning vertical       4.7       R      √3      1     0.67          2.7         1.8
    Device Positioning Lateral        1.0       R      √3      1      1            0.6         0.6
    Device Holder and Phantom         2.4       R      √3      1      1            1.4         1.4
    Power drift                       5.0       R      √3      1      1            2.9         2.9
    Phantom and Setup Related
    Phantom thickness                2.4     R      √3     1     0.67           1.4           0.9
                                     Combined Standard Uncertainty:             14.7          10.9
                        Extended Standard Uncertainty on Power (k=2):           29.4          21.8
                         Extended Standard Uncertainty on Field (k=2):          14.7          10.9
          N: Normal
          R: Rectangular

                  Table 9.1 Worst-Case uncertainty budget for HAC free field assessment




© 2012 Comptest Services LLC                        Page 18 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



10      RF EMISSIONS TESTS


  10.1 Emission Limits
      FCC: § 20.19, ANSI C63.19-2007
        IC:
   Table 10.1 shows the M-rating criteria from ANSCI C63.19. All digital transmission modes in all
   frequency bands contained in a HAC phone must meet M3 or M4 levels.

             Near                          Wireless Device RF Parameters
             Field                                   [AWF = 0]
                                E-Field Emissions                       H-Field Emissions
          Category
                         dB(V/m) Peak          V/m Peak         dB(A/m) Peak           A/m Peak
                                               Freq < 960 MHz
              M1         56.0 to 61.0       631.0 to 1122.0       5.6 to 10.6         1.91 to 3.39
              M2         51.0 to 56.0        354.8 to 631.0       0.6 to 5.6          1.07 to 1.91
              M3         46.0 to 51.0        199.5 to 354.8       -4.4 to 0.6         0.60 to 1.07
              M4             < 46.0             < 199.5              < -4.4              < 0.60
                                               Freq > 960 MHz
              M1         46.0 to 51.0        199.5 to 354.8       -4.4 to 0.6         0.60 to 1.07
              M2         41.0 to 46.0        112.2 to 199.5      -9.4 to -4.4         0.34 to 0.60
              M3         36.0 to 41.0        63.1 to 112.2       -14.4 to -9.4        0.19 to 0.34
              M4             < 36.0              < 63.1             < -14.4              < 0.19



                                        Table 10.1 RF Emission Limits




© 2012 Comptest Services LLC                        Page 19 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0




 10.2 CDMA 800 BC-0 Test Results
  Configuration:      Slide Close                                       Antenna:       Fixed
                                              CDMA 800 E-Field
       Ch.         Backlight         Power           Dasy4            PMF          Peak Field      Category
                                                    Reading

        #                             dBm             V/m                             V/m              M
      1013             ON             24.63           70.90           1.00           70.90             4
       384             ON             24.73           69.00           1.00           69.00             4
       777             ON             24.61           60.00           1.00           60.00             4
                                              CDMA 800 H-Field
       Ch.         Backlight         Power           Dasy4            PMF          Peak Field      Category
                                                    Reading

        #                             dBm             A/m                             A/m              M
      1013             ON             24.63           0.109           1.00           0.109             4
       384             ON             24.73           0.101           1.00           0.101             4
       777             ON             24.61           0.089           1.00           0.089             4




© 2012 Comptest Services LLC                        Page 20 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0



10.3 CDMA 1900 Test Results
 Configuration:        Slide Close                                           Antenna:         Fixed
                                             CDMA 1900 E-Field
      Ch.         Backlight          Power          Dasy4            PMF           Peak Field         Category
                                                   Reading

       #                             dBm              V/m                               V/m              M
      25              ON             24.62           44.30            1.00           44.30               4
      600             ON             24.72           46.40            1.00           46.40               4
     1175             ON             24.57           47.80            1.00           47.80               4
                                             CDMA 1900 H-Field
      Ch.         Backlight          Power          Dasy4            PMF           Peak Field         Category
                                                   Reading

       #                             dBm              A/m                               A/m              M
      25              ON             24.62           0.146            1.00           0.146               4
      600             ON             24.72           0.164            1.00           0.164               4
     1175             ON             24.57           0.154            1.00           0.154               4




© 2012 Comptest Services LLC                        Page 21 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:    Kyocera
                                                                       FCC ID:      V65C5155
                                                                      Report #:     CT-C5156_20RF-0712-R0


10.4 Worst-Case Configuration Evaluation
The probe was rotated 360o at Azimuth axis in the worst case configuration. The rotation was performed
at the location of maximum field strength in the included blocks.


                                           CDMA 800 BC-0 E-Field
   Configuration:          Slide Close                            Antenna:         Fixed
       Ch.          Backlight      Conducted       Peak Field         PMF          Peak Field      Category
                                     Power
         #                            dBm             V/m                             V/m              M
       1013            ON             24.63           69.61           1.00            69.61            4



                                              CDMA 1900 E-Field
   Configuration:          Slide Close                            Antenna:         Fixed
       Ch.          Backlight     Conducted        Peak Field         PMF          Peak Field      Category
                                    Power
         #                            dBm             V/m                             V/m              M
       1175            ON          24.57             48.79            1.00            48.79            4
        Data plots are shown in Appendix C




© 2012 Comptest Services LLC                        Page 22 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                      Applicant:   Kyocera
                                                                       FCC ID:     V65C5155
                                                                      Report #:    CT-C5156_20RF-0712-R0


11      APPENDIX A: PROBE CALIBRATION CERTIFICATION

(See attachment)

12      APPENDIX B: SYSTEM VALIDATION DATA PLOTS

(See attachment)

13      APPENDIX C: TEST RESULTS/PLOTS

(See attachment)

14      APPENDIX D: PHOTO TEST SETUP

(See attachment)




© 2012 Comptest Services LLC                        Page 23 of 23                                 HAC RF Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.



Document Created: 2012-08-07 12:46:39
Document Modified: 2012-08-07 12:46:39

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC