C2PC SAR report

FCC ID: V65C5155

RF Exposure Info

Download: PDF
FCCID_1783395

                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1




                                   Specific Absorption Rate
                                             (SAR)

                                       FCC 47 CFR Part 2


                                              Test Report

                                                     For

                                 Kyocera Corporation
                           c/o Kyocera Communication, Inc.




              Product:                  Dual-Band CDMA Mobile Phone
               Model:                              C5156




© 2012 Comptest Services LLC                         Page 1 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                                                Applicant:       Kyocera
                                                                                                 FCC ID:         V65C5155
                                                                                                Report #:        CT-C5156-9-0712-R1

                                                          TABLE OF CONTENTS

1     SUMMARY OF TESTING ................................................................................................................. 4
2     EQUIPMENT UNDER TEST INFORMATION ................................................................................... 5
3     ACCESSORIES ................................................................................................................................ 5
    3.1      BODY W ORN ACCESSORIES ........................................................................................................ 5
    3.2      BATTERIES ................................................................................................................................. 5
4     TEST CONDITIONS ......................................................................................................................... 6
    4.1      TEST FACILITIES ......................................................................................................................... 6
    4.2      AMBIENT CONDITIONS ................................................................................................................. 6
    4.3      RF CHARACTERISTICS OF THE TEST SITE ...................................................................................... 6
    4.4      TEST SIGNAL, FREQUENCIES AND OUTPUT POWER ....................................................................... 7
    4.5      DEVICE TEST CONDITIONS........................................................................................................... 9
    4.6      MULTIPLE TRANSMITTERS AND ANTENNAS SAR EVALUATIONS..................................................... 10
    4.7      ROUTER SAR EVALUATIONS...................................................................................................... 12
    4.8      HAND SAR EVALUATIONS.......................................................................................................... 12
    4.9      SAR TESTS IN MOUTH AND JAW REGIONS OF THE SAM PHANTOM .............................................. 13
5     DESCRIPTION OF THE TEST EQUIPMENT ................................................................................. 14
    5.1      DOSIMETRIC SYSTEM ................................................................................................................ 14
    5.2      ADDITIONAL EQUIPMENT NEEDED IN VALIDATION.......................................................................... 16
    5.3      TISSUE STIMULANTS ................................................................................................................. 16
    5.4      PHANTOMS DESCRIPTION .......................................................................................................... 17
    5.5      ISOTROPIC E-FIELD PROBE ....................................................................................................... 18
6     SYSTEM VALIDATION .................................................................................................................. 19
7     DESCRIPTION OF THE TEST PROCEDURE ................................................................................ 21
    7.1      TEST POSITIONS ....................................................................................................................... 21
    7.2      SCAN PROCEDURES .................................................................................................................. 23
    7.3      SAR AVERAGING METHODS ...................................................................................................... 23
8     MEASUREMENT UNCERTAINTY.................................................................................................. 24
9     TEST DATA.................................................................................................................................... 25
    9.1      HEAD SAR TEST RESULTS ........................................................................................................ 25
    9.2      BODY-W ORN SAR TEST RESULTS ............................................................................................. 28
10    SIMULTANEOUS SAR EVALUATION ........................................................................................... 31
    10.1     SUMMATION OF HIGHEST MEASURED SAR VALUES .................................................................... 31
    10.2     SUMMATION OF HIGHEST SCALED SAR VALUES ......................................................................... 32
11    LIST OF APPENDIX ....................................................................................................................... 33




© 2012 Comptest Services LLC                         Page 2 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1




                                             ATTESTATION

 The tested device complies with the requirements in respect of all parameters subject to the test.
 The test results and statements relate only to the items tested.
 The test equipment used was suitable for the tests performed and within manufacturer’s published
 specifications and operating parameters.
 The test methods were consistent with the methods described in the relevant standards.

                           Product: Dual-Band CDMA Mobile Phone with Bluetooth and WLAN

                           Model #: C5156

                            FCC ID: V65C5155

      Tested in accordance with: FCC §2.1093/OET-65 Supplement C
                                 IEEE P2528/D1.2 – 2003
                                 FCC KDB 248227 D01 v01r02
                                 FCC KDB 648474 D01 v01r05
                                 FCC KDB 941225 v2
              Test Requested by: KYOCERA Corporation
                                 C/o KYOCERA Communication Inc.
                                 8611 Balboa Avenue
                                 San Diego, CA 92123 United States
               Test performed by: CompTest Services LLC

                      Date of Test: July 11 – August 7, 2012




    Responsible Engineer                                            Reviewed and approved by:



     Benjamin Nguyen
    Benjamin Nguyen                                                 Tammy To
    Test Engineer                                                   Quality Manager




© 2012 Comptest Services LLC                         Page 3 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:     Kyocera
                                                                        FCC ID:       V65C5155
                                                                       Report #:      CT-C5156-9-0712-R1



1       SUMMARY OF TESTING
The equipment is deemed to fulfill the requirements if the measured values are less than or equal to the
limit.
                                             Measured Standalone            FCC Limit
    Mode-Band             Position                                                               Result
                                                 SAR (W/kg)                 (W/kg, 1g)
    CDMA-800                Head                    0.98                                        PASSED
                       Body – 15 mm                    0.70                                     PASSED
    CDMA-1900               Head                       1.36                     1.6             PASSED
                       Body – 15 mm                    0.75                                     PASSED
                            Head                       0.13                                     PASSED
    WLAN-2450
                       Body – 15 mm                    0.09                                     PASSED




© 2012 Comptest Services LLC                         Page 4 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1


2       EQUIPMENT UNDER TEST INFORMATION

                 Product:         Dual-Band CDMA Mobile Phone with Bluetooth and WLAN
                  FCC ID:         V65C5155
          Model Number:           C5156
      EUT Serial Number:          268435457816727796
                    Type:         [ ] Identical Prototype, [X] Pre-Production, [ ] Production
        Device Category:          Portable
RF Exposure Environment:          General Population / Uncontrolled
         CDMA Antenna:            Internal                                          Detachable:         No
    WiFi/Bluetooth Antenna:       Internal                                            Detachable:       No
                External Input: Audio/Digital Data
                     Quantity: Quantity production is planned
                                       CDMA                CDMA
                        Mode:        1X & EvDo           1x & EvDo            802.11             Bluetooth
                                      Rev0, A             Rev0, A              b/g/n
                      Band:            BC-0               BC-1                   --                 --
        TX Frequency (MHz):         824.7 -848.3        1850 -1910          2412 -2462         2400 -2483.5



3       ACCESSORIES

 3.1 Body Worn Accessories
    The device has been tested with the following body worn accessories that contains metal parts and
    separation distance between the device and the user’s body is listed in the table below.

     Accessory                          Model                                   Separation (mm)
     Air                                N/A                                     15.0




 3.2 Batteries
    The device was tested with the following battery packs:

     Battery                            Model                                   Specifications
     Standard                           SCP-46LBPS                              3.7V, 1500mAh




© 2012 Comptest Services LLC                         Page 5 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1


4       TEST CONDITIONS


    4.1 Test Facilities
    The test sites and measurement facilities used to collect data are located at 8611 Balboa Avenue,
    San Diego, CA 92123, USA




    4.2 Ambient Conditions
    All tests were performed under the following environmental conditions:

             Ambient Temperature:                            22  1 Degrees C
             Tissue simulating liquid temperature:           22  1 Degrees C
             Humidity:                                       38 %
             Pressure:                                       1015 mB




 4.3     RF characteristics of the test site
    All SAR measurements were performed inside a shielded room that provides isolation from external
    EM fields.

    External fields are minimizing by the shielded room, leaving the phone as the dominant radiation
    source. Two 2-foot square ferrite panels are placed on the floor of the room beneath the phantom
    area of the DASY system to minimize reflected energy that would otherwise re-enter the phantom
    and combine constructively or destructively with the desired fields. These ferrite panels provide
    roughly 12 to 13 dB of attenuation in the frequency range of 900 MHz, and 7 to 8 dB of attenuation
    in the frequency range of 1.9 GHz.




© 2012 Comptest Services LLC                         Page 6 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

 4.4     Test Signal, Frequencies and Output Power
   In all operating bands, the measurements were performed on low, mid and high channels.
   The phone was set to nominal maximum power level during all tests and at the beginning of each
   test.

   DASY4 system measures power drift during SAR testing by comparing E-field in the same location
   at the beginning and at the end of measurement. These records were used to monitor stability of
   power output.

   4.4.1 CDMA2000/EVDO Test conditions
   The device supports CDMA2000 in 1X (Phase I, Protocol revision 6) and 1x EvDo Rev 0, A
   modes. CDMA2000 1X includes TIA/EIA-95B as a subset and was approved for publishing in July
   1999. It provides voice and data capabilities within a standard 1.25 MHz CDMA channel. This RF
   bandwidth is identical to the legacy IS-95 B system standard.

   4.4.1.1 SAR Test Reduction

   When maximum output variation across channels of each band/mode is < ½ dB, either maximum
   output or middle channels may be used to determine test reduction for each mode in a cellphone;
   otherwise, the maximum output channel was used to determine test reduction for each band/mode.

   If the SAR measured at the reduction tested channel is at least 3dB lower than the SAR limit,
   testing at other channels were optional.

   4.4.1.2 Head SAR Measurements

   SAR for head exposure configurations was measured in RC3 with the EUT configured to transmit at
   full rate using Loopback Service Option SO55. SAR for RC1 was not required when the maximum
   average output of each channel was less than ¼ dB higher than that measured in RC3. Otherwise,
   SAR was measured on the maximum output channel in RC1 using the exposure configuration that
   results in the highest SAR for that channel in RC3.




© 2012 Comptest Services LLC                         Page 7 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

   4.4.1.3 Body SAR Measurements

   SAR for body exposure configurations was measured in RC3 with the DUT configured to transmit at
   full rate on FCH with all other code channels disabled using TDSO / SO32. SAR for multiple code
   channels (FCH + SCHn) was not required when the maximum average output of each RF channel
   was less than ¼ dB higher than that measured with FCH only. Otherwise, SAR was measured on
   the maximum output channel (FCH + SCHn) with FCH at full rate and SCH0 enabled at 9600 bps
   using the exposure configuration that results in the highest SAR for that channel with FCH only.
   When multiple code channels were enabled, the DUT output may shift by more than 0.5 dB and
   lead to higher SAR drifts and SCH dropouts.

   Body SAR in RC1 was not required when the maximum average output of each channel was less
   than ¼ dB higher than that measured in RC3. Otherwise, SAR was measured on the maximum
   output channel in RC1; with Loopback Service Option SO55, at full rate, using the body exposure
   configuration that resulted in the highest SAR for that channel in RC3.

   4.4.1.4 Devices with Ev-Do

   For devices with Ev-Do capabilities, when the maximum average output of each channel in Rev. 0
   was less than ¼ dB higher than that measured in RC3 (1x RTT), body SAR for Ev-Do was not
   required. Otherwise, SAR for Rev. 0 was measured on the maximum output channel at 153.6 kbps
   using the body exposure configuration that resulted in the highest SAR for that channel in RC3.
   SAR for Rev. A was not required when the maximum average output of each channel was less than
   that measured in Rev. 0 or less than ¼ dB higher than that measured in RC3. Otherwise, SAR was
   measured on the maximum output channel for Rev. A using a Reverse Data Channel payload size
   of 4096 bits and a Termination Target of 16 slots defined for Subtype 2 Physical Layer
   configurations. A Forward Traffic Channel data rate corresponding to the 2-slot version of 307.2
   kbps with the ACK Channel transmitting in all slots should be configured in the downlink for both
   Rev. 0 and Rev. A


   4.4.1.5 Power Reduction (PR)

   The device does:

      not implement power reduction.

       implement power reduction only at the following conditions:

    Configuration:
    Band:
    Mode:
    Power Reduction:




© 2012 Comptest Services LLC                         Page 8 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:    Kyocera
                                                                        FCC ID:      V65C5155
                                                                       Report #:     CT-C5156-9-0712-R1

   4.4.1.6 RF Conducted Power Data

   Table 4.4 below shows the maximum power level vs RCs:

       CONFIGURATION                                  CONDUCTED POWER (dBm)
            (Full Rate)                      CDMA 800 BC-0                          CDMA 1900 BC-1
                                       Ch          Ch           Ch           Ch           Ch           Ch
                                      1013         384          777          25           600         1175

                  RC1                24.70        24.70        24.60        24.54        24.62       24.65
    SO2
                  RC3                24.65        24.73        24.60        24.55        24.56       24.66

                  RC1                24.60        24.68        24.58        24.61        24.70       24.50
    SO55
                  RC3                24.63        24.73        24.61        24.62        24.72       24.62

                  RC3
                                     24.60        24.71        24.61        24.58        24.69       24.60
    TDSO          (SCH)
    SO32          RC3
                                     24.69        24.68        24.59        24.59        24.69       24.59
                  (+FCH-SCH)
                  RTAP               24.72        24.70        24.68        24.61        24.70       24.68
    EvDo
    Rev 0
                  FTAP               24.63        24.70        24.67        24.68        24.70       24.76

                  RTAP               24.72        24.74        24.72        24.66        24.79       24.78
    EvDo
    Rev A
                  FTAP               24.69        24.73        24.70        24.67        24.76       24.77

    Maximum output variation
                                                 < ½ dB                                 < ½ dB
    across channels:

                       Table 4.4 RC Configuration tested at “all up” power control bit.


  4.5 Device Test Conditions
   The EUT was tested with a fully charged battery as supplied with the handset. Conducted RF
   power measurements were performed before and after each SAR measurements to confirm the
   output power.




© 2012 Comptest Services LLC                         Page 9 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                         Applicant:   Kyocera
                                                                          FCC ID:     V65C5155
                                                                         Report #:    CT-C5156-9-0712-R1



  4.6 Multiple Transmitters and Antennas SAR evaluations
   Licensed transmitters required routine SAR evaluation as followed by IEEE 1528 Supplement C 3G
   FCC SAR Procedures.

   Guidelines provided in FCC “SAR Evaluation Considerations for Handsets with Multiple
   Transmitters and antennas, February 2008” were followed for evaluation of the need for
   simultaneous transmission SAR testing. If the sum of measured 1g SAR is < 1.6 W/kg for all
   simultaneous transmitting antennas, or If the SAR-to-Peak-Location-Separation-Ratio for two
   simultaneous transmitting antennas is < 0.3, SAR evaluation for simultaneous transmission is not
   required.

   For an unlicensed transmitter such as 802.11 a/b/g and Bluetooth devices that does not transmit
   simultaneously with other transmitters and its output conducted power is < 60/f(GHz) mW, SAR
   evaluation is not required.

   If the handset contains unlicensed transmitters, which may simultaneously transmit with the
   licensed transmitter, the conducted output power of the unlicensed transmitter was measured and
   compared with the power reference (Pref) as shown in table 4.6. The antenna separation was
   determined by the closest distance between the antennas. Both criteria were evaluated to
   determine whether stand-alone SAR or simultaneous transmission SAR testing is required.

         Freq. Band:               2.45 GHz               5.15-5.35 GHz                5.47-5.85 GHz
          Pref (mW):                  12                       6                             5
                            Table 4.6aUnlicensed Transmitter Output Power Threshold

   When there is simultaneous transmission -
                                      Standalone SAR not required when
         Output Power                               Antenna Separation (cm)
              ≤ Pref              < 2.5 with other transmitters output power ≤ Pref or 1g SAR <1.2 W/kg
              ≤ Pref                                         ≥ 2.5 and ≤ 5.0
             ≤ 2*Pref                                            ≥ 5.0
                                    Table 4.6b Standalone SAR requirements

   When Stand-alone SAR measurements is required. SAR is tested on highest output channel for
   each wireless mode and exposure condition. If SAR for highest output channel is > 50% of SAR
   limit, all channels will be evaluated according to normal procedures.

                                    Simultaneous SAR not required when
   Unlicensed only:           Standalone SAR is not required and antenna is > 5cm from other antennas
      Licensed &           Sum of SAR is < 1.6 W/kG for each pair of simultaneous transmitting antennas
      Unlicensed:       SAR to peak location separation ratio of simultaneous transmitting antenna pair is <0.3
                                 Table 4.6c Simultaneous SAR requirements




© 2012 Comptest Services LLC                        Page 10 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                        Applicant:   Kyocera
                                                                         FCC ID:     V65C5155
                                                                        Report #:    CT-C5156-9-0712-R1

   4.6.1    Bluetooth/WLAN Test Conditions

   4.6.1.1 Bluetooth/WLAN RF Conducted Power Data

   Unlicensed transmitters are controlled by chipset based test mode software to establish maximum
   output power.

              Mode           Data Rate                         CONDUCTED POWER (dBm)
                              (Mbps)                   Ch 01              Ch 06                 Ch 11
                                                      2412 MHz          2437 MHz            2462 MHz
             802.11b                    1              13.87              14.51                 12.38
                                       11              13.89              14.68                 12.52
             802.11g                    6              12.57              13.35                 10.78
                                       54              10.32              10.70                  9.02
             802.11n              MSC0                 12.57              13.51                 10.87
                                  MSC7                  9.97              10.28                  8.69
           WLAN supported:      Yes              No
        1) Per KDB 248227, highest average output power channel for the lowest data rate are selected for SAR
           evaluation. Other IEEE802.11 modes (including 802.11n) are not investigated if the average output
           powers are not greater than 0.25dB than that of the corresponding channel in the lowest data rate
           IEEE802.11b mode.
        2) SAR measurements were tested at the bolded data rate. Mode bolded in blue resulted in the highest
           SAR data.

   Based on the Antenna separation and output power, Stand-Alone and Simultaneous Transmission
   SAR testing requirements are listed below:

        MEASURED PARAMETERS (UNLICENSED TRANSMITTER)
                   Transmitter:                          Bluetooth                       802.11
               Antenna Separation                         4.5 cm                         4.5 cm
                                  3)
                 Output Power                              1 mW                          71 mW
                                       4)
                Standalone SAR                                 No                         Yes
              Simultaneous TX SAR                              No                          No
                                            5)
           Highest 1g SAR value, Body
                                                               --                         0.84
                (CDMA + WLAN)
        3) Rounded to the nearest mW
        4) Only highest power transmitter was tested, if applicable.
        5) Voice call in head configuration is not supported with Bluetooth mode.




© 2012 Comptest Services LLC                        Page 11 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

  4.7 Router SAR Evaluations
   For portable devices equipped with wireless router (Hotspot) feature, additional SAR evaluation is
   performed per interim guidelines provided at the October 2010 TCB Workshop.

   This device is not capable of functioning as a WiFi to Cellular mobile hotspot. Testing was not
   performed at 10 mm.




  4.8 Hand SAR Evaluations
   When applicable, Hand SAR was evaluated with following test procedures:

      Test separation distance: 0 (zero) mm
      SAR is averaged over 10g of tissue

   Hand SAR required:       Yes       No




© 2012 Comptest Services LLC                        Page 12 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

  4.9 SAR Tests in Mouth and Jaw Regions of the SAM Phantom
   Antennas located near the bottom of a phone may require SAR measurements around the mouth and
   jaw regions of the SAM head phantom. This typically applies to clam-shell style phones that are
   generally longer in the unfolded normal use positions or to certain older style long rectangular
   phones. It has been known for some time that there are SAR measurement difficulties in these
   regions of the SAM phantom. SAR probes are calibrated in tissue-equivalent liquids with sufficient
   separation between the probe sensors and nearby physical boundaries to ensure scattering does not
   affect probe calibration. When the probe tip is moved into tight regions with multiple boundaries
   surrounding its sensors, probe calibration and measurement accuracy can become questionable. In
   addition, these measurement locations often require a probe to be tilted at steep angles, where it may
   no longer comply with calibration requirements and measurement protocols, or satisfy the required
   measurement uncertainty. In some situations it is not feasible to tilt the probe or rotate the phantom,
   as suggested by measurement standards, to conduct these measurements.

   In order to ensure there is sufficient conservativeness for ensuring compliance until practical solutions
   are available, additional measurement considerations are necessary to address these technical
   difficulties. When measurements are required near the mouth, nose, jaw or similar tight regions of
   the SAM phantom, area or zoom scans are often unable to fully enclose the peak SAR location as
   required by IEEE 1528 and Supplement C, due to probe orientation and positioning difficulties. Even
   when limited measurements are possible, the test results could be questionable due to probe
   calibration and measurement uncertainty issues. Under these circumstances, the following
   procedures apply:

   The SAR required in these regions of SAM should be measured using a flat phantom.

      Rectangular shaped phones should be positioned with its bottom edge positioned from the flat
       phantom with the same distance provided by the cheek touching position using SAM. The ear
       reference point (ERP, as defined for SAM) of the phone should be positioned ½ cm from the flat
       phantom shell.
      Clam-shell phones should be positioned with the hinge against a smooth edge of the flat phantom
       where the upper half of the phone is unfolded and extended beyond the phantom side wall. The
       lower half of the phone is secured in the test device holder at a fixed distance below the flat
       phantom determined by the minimum separation along the lower edge of the phone in the cheek
       touching position using SAM. If there is substantial variation in separation distance along the
       lower edge of a clam- shell phone when placed in the cheek touching position using SAM, the
       FCC Laboratory may be contacted for additional guidance to position the phone for testing.

   The flat phantom data should allow test results to be compared uniformly across measurement
   systems, until suitable solutions are available in measurement standards to address certain probe
   calibration and positioning issues, due to implementation differences between horizontal and up- right
   SAM configurations. These flat phantom procedures are only applicable to stand-alone SAR
   evaluation in tight regions of the SAM phantom, where measurement is not feasible or test results
   can be questionable due to probe calibration and accessibility issues. Details on device positioning
   and photos showing how separation distances are determined should be included in the SAR report.
   SAR for other regions of the head must be evaluated using SAM; therefore, a phone with antennas at
   different locations may require flat and SAM phantom evaluation for the different antennas. When
   simultaneous transmission SAR evaluation is necessary in these regions of SAM and until practical
   solutions are available, the FCC Laboratory should be contacted for interim guidance.




© 2012 Comptest Services LLC                        Page 13 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:     Kyocera
                                                                        FCC ID:       V65C5155
                                                                       Report #:      CT-C5156-9-0712-R1


5       DESCRIPTION OF THE TEST EQUIPMENT

    5.1 Dosimetric System
    The measurements were performed with an automated near-field scanning system (as shown in
    Figure 5.1), DASY4, manufactured by Schmid & Partner Engineering AG (SPEAG) of Zurich,
    Switzerland. The system is comprised of high precision robot, robot controller, computer, near-field
    probe, probe alignment sensor and the SAM phantom containing brain or muscle equivalent material.
    The measurement uncertainty budget is given in section 8.

    Below is a list of the calibrated equipment used for the measurements:

                  Test Equipment                  Serial Number        Cal. Due Date            Used
         DASY4 DAE4                                      603               09-27-12
         DASY4 DAE4                                      675               05-23-13
         DASY4 DAE4                                      530               05-30-13
         E-field Probe ET3DV6                           1618               09-19-12
         E-field Probe ES3DV3                           3035               02-22-13
         E-field Probe ES3DV3                           3036               05-11-12
         E-field Probe ES3DV3                           3078               09-19-12
         Dipole Validation kit, D835V2                   467               09-02-12
         Dipole Validation kit, D1900V2                5d016               09-07-12
         Dipole Validation kit, D2450V2                  776               07-09-13


    The calibration records of E-field probe and dipoles are attached in Appendix C and Appendix D
    respectively.




                                           Figure 5.1 DASY 4 System




© 2012 Comptest Services LLC                        Page 14 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:    Kyocera
                                                                        FCC ID:      V65C5155
                                                                       Report #:     CT-C5156-9-0712-R1

   5.1.1 Extended SAR Dipole Calibrations
   Dipoles are calibrated on a 2-year intervals. Return-loss and input impedances are measured
   annually to confirm in maintaining requirements per KDB Publication 450824 DO2, Dipole SAR
   Validation Verification v01:

      Return Loss is <-20dB or within 20% of calibrated measurement
      Impedance is within 5 of calibrated measurement

                                                  835 MHz - HEAD
        Dipole                               Return Loss      Impedance ()
                   Date       Description                                                   Comments
         S/N                                     (dB)       Real         Img
                 09/02/10           Target      -37.1       49.8         -1.4       Within 1 year of calibration
         467     10/20/11       Measured        -25.5       46.3          2.0       No physical damage found
                            Delta


                                                  1900 MHz - HEAD
        Dipole                               Return Loss      Impedance ()
                   Date       Description                                                   Comments
         S/N                                     (dB)       Real         Img
                 09/07/10           Target      -27.0       51.2          4.4       Within 1 year of calibration
        5d016    10/20/11       Measured        -30.6       51.1          1.0       No physical damage found
                            Delta




© 2012 Comptest Services LLC                        Page 15 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:    Kyocera
                                                                        FCC ID:      V65C5155
                                                                       Report #:     CT-C5156-9-0712-R1

  5.2 Additional equipment needed in validation

                   Test Equipment                            Serial Number               Cal. Due Date
    Communication Test Set Agilent 8960                       US41070147                   10-20-12
    Signal Generator, Agilent E4438C                          MY44270167                   08-12-12
    Power meter, Giga-tronics 8541C                             1833762                    11-21-12
    Power Sensor, Giga-tronics 80601A                           1831776                    11-21-12
    Network Analyzer, Agilent E5062A                          MY44100250                   05-16-12
    Electronic Calibration Module, Agilent                        1763                     05-16-12
    Thermometer                                                 186700                     08-03-13
    Dielectric Probe, HP 85070E                                     --                   No cal required




  5.3 Tissue Stimulants
   All dielectric parameters of tissue stimulants were measured within 24 hours of SAR
   measurements. The depth of the tissue stimulant in the ear reference point and flat reference point
   of the phantom were at least 15 cm. during all the tests. The depth of the liquid is measured by
   running a program that brings the probe to the bottom surface of the phantom then raise it up 15
   centimeters. The operator at this point performs a visual inspection and makes sure that the liquid
   level is at or above the probe tip.

   The list of ingredients and the percent composition used for the Head and Muscle tissue simulates
   are listed in the table below:


                                 835 MHz           1700 MHz             1900 MHz              2450 MHz
    INGREDIENT            HEAD      MUSCLE      HEAD     MUSCLE       HEAD     MUSCLE      HEAD      MUSCLE
    Water                51.07%      65.45%     56.6%      68%        54%       69.91%      55 %     68.64%
    Cellulose             0.23%        --         --         --         --          --        --        --
    Glycol monobuthyl       --         --        43%       31.5%     44.91%     29.96%      45%      31.37%
    Sugar                47.31%      34.31%       --         --         --          --        --        --
    Preventol             0.24%       0.1%        --         --         --          --        --        --
    Salt                  1.15%      0.62%      0.4%       0.5%      0.21%      0.13%         --        --

   The ingredients above are adopted from Application Note: Recipes for Head/Muscle Tissue
   Simulating Liquid by SPEAG.




© 2012 Comptest Services LLC                        Page 16 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1



  5.4 Phantoms Description
   SAM v4.0 phantom, manufactured by SPEAG, was used during the measurement. It has fiberglass
   shell integrated in a wooden table. The shape of the shell corresponds to the phantom defined in
   IEEE 1528/D1.2. It enables the dosimetric evaluation of left and right hand phone usage as well as
   body mounted usage at the flat phantom region. Reference markings on the phantom allow the
   complete set-up of all predefined phantom positions and measurement grids by manually teaching
   three points in the robot.

   The thickness of phantom shell is 2mm except for the ear, where an integrated ear spacer provides
   6mm spacing from the tissue boundary. Manufacturer reports tolerance in shell thickness to be ±
   0.1mm.




                                        Figure 5.4 SAM Twin Phantom




© 2012 Comptest Services LLC                        Page 17 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

  5.5 Isotropic E-Field Probe



                       Model:       ET3DV6



                                    Symmetrical design with triangular core
                                    Built-in optical fiber for surface detection system
              Construction:         Built-in shielding against static charges
                                    PEEK enclosure material (resistant to organic solvents, e.g.,
                                     glycol)
                 Calibration:       Calibration certificate in Appendix C
                                    10MHz to 3GHz (dosimetry); Linearity:  0.2dB (30MHz to
                 Frequency:
                                     3GHz)

            Optical Surface:
                                      0.2mm repeatability in air and clear liquid over diffuse
                                     reflecting
                   Detection:       Surface
                                     0.2dB in HSL (rotation around probe axis)
                  Directivity:
                                     0.4dB in HSL (rotation normal to probe axis)
           Dynamic Range:           5 uW/g to > 100 mW/g; Linearity:  0.2dB
                                    Overall length: 330mm
                                    Tip length: 16mm
                Dimensions:         Body diameter: 12mm
                                    Tip diameter: 6.8mm
                                    Distance from probe tip to dipole centers: 2.7mm
                                    General dosimetry up to 3GHz
                Application:        Compliance tests of mobile phones
                                    Fast automatic scanning in arbitrary phantoms.




© 2012 Comptest Services LLC                        Page 18 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1


6           SYSTEM VALIDATION

The probes are calibrated annually by the manufacturer. Dielectric parameters of the stimulating liquids are
measured with an automated Hewlett Packard 85070E dielectric probe in conjunction with an Agilent
E5062A ENA serial network analyzer.

The SAR measurements of the device were done within 24 hours of system accuracy verification, which
was done using the dipole validation kit. Power level of 20dBm was supplied to a dipole antenna placed
under the flat section of SAM phantom. The validation results are in the table below and printouts of the
validation test are attached in Appendix A. All the measured parameters are within the specification.

The system validation with head tissues was used for the device testing in muscle. Based on OET 65
Supplement C EAB Part 22/27/24 SAR review Reminder Sheet 01/2002, this is a valid test.

                                      System/Tissue Verification - HEAD
                                    Validation        Dielectric
                                       SAR          Parameters
    Freq.                                                              Temp.                 Comments
              Date      Description  (mW/g),       εr        σ (S/m)     o
    (MHz)                                                               ( C)
                                        1g
                              FCC Reference*:    41.50        0.90      20-26
             04/20/09     Target       0.967                                     From Speag Certificate
    835
             07/16/12    Measured      0.97      43.00       0.91       22±1     For device testing in Head.
             07/17/12    Measured      0.98      42.70       0.91       22±1     For device testing in Head.
                              FCC Reference*:    40.00       1.40       20-26
             09/07/10     Target       3.96                                      From Speag Certificate
    1900     07/11/12    Measured      4.01      38.60       1.40       22±1     For device testing in Head.
             07/12/12    Measured      4.07      39.20       1.43       22±1     For device testing in Head.
             07/16/12    Measured      3.92      38.60       1.41       22±1     For device testing in Head.
                              FCC Reference*:    39.20       1.80       20-26
             09/07/10     Target       5.32                                      From Speag Certificate
    2450
             08/06/12    Measured      5.15      38.70       1.86       22±1     For device testing in Head.
             08/07/12    Measured      5.11      38.80       1.87       22±1     For device testing in Head.




© 2012 Comptest Services LLC                        Page 19 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

                                     System/Tissue Verification - BODY
                                  Validation          Dielectric
  Freq.                             SAR             Parameters         Temp.                 Comments
            Date     Description                                         o
  (MHz)                          (mW/g), 1g         εr       σ (S/m)    ( C)
                             FCC Reference*:       55.2        0.97    20-26
   835    04/20/09      Target        0.995                                      From Speag Certificate
          07/18/12    Measured        0.94        54.60       0.94      22±1     For device testing in Muscle
                             FCC Reference*:       53.3       1.52      20-26
  1900    09/07/10      Target         4.01                                      From Speag Certificate
          07/17/12     Measured        4.08       51.70       1.52      22±1     For device testing in Muscle
                             FCC Reference*:       52.7       1.95      20-26
  2450    07/09/12      Target        5.28                                       From Speag Certificate
          08/07/12    Measured        4.83        52.80       1.92      22±1     For device testing in Muscle



*FCC reference values are adopted from OET Bulletin 65 (97-01) Supplement C (01-01).

When applicable, the measured 10g SAR were verified within 10% of the expected target values for Hand SAR
measurements.




© 2012 Comptest Services LLC                        Page 20 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1


7       DESCRIPTION OF THE TEST PROCEDURE
Measurements were made on both left hand side and right hand side of the phantom.

The device was position against phantom according to OET Bulletin 65 (97-01) Supplement C (01-01).
Definitions of terms used in aligning the device to a head phantom are available in IEEE Standard
P1528/D1.2 “Recommended Practice for Determining the Spatial-Peak Specific Absorption Rate (SAR)
in the Human Body Due to Wireless Communications Devices: Experimental Techniques”

    7.1 Test Positions
    The device was placed in the holder. The bottom of the device aligns with the bottom of the holder
    clamp to provide a standard positioning and ensure enough free space for antenna.

    Device holder was provided by SPEAG together with DASY4.



    7.1.1   Initial Ear Position

    The device was initially positioned with the earpiece region pressed against the ear spacer of a head
    phantom parallel to the “Neck-Front” (N-F) line defined along the base of the ear spacer that contains
    the “Ear Reference Point” (ERP). The “test device reference point” (point A) is aligned to the ERP on
    the head phantom and the “vertical centerline” is aligned to the “phantom reference plane”.

                                vertical
                               center line
                          wt/2 wt/2


                           .           horizonta
                                         l line
                                       A
             acousti
             c output                  B
                                             bottom of
                                             handset


                         wb/2 wb/2


     Figure 7-1a – Handset vertical and                           Figure 7-1b - Close up side view of
     horizontal reference lines.                                  phantom showing the ear region.




© 2012 Comptest Services LLC                        Page 21 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:     Kyocera
                                                                        FCC ID:       V65C5155
                                                                       Report #:      CT-C5156-9-0712-R1


   7.1.2 Cheek Position
   “Initial ear position” alignments are maintained and the device is brought toward the mouth of the head
   phantom by pivoting along the “Neck-Front” line until any point on the display, keypad or mouthpiece
   portions of the handset is in contact with the phantom or when any portion of a foldout, sliding or
   similar keypad cover opened to its intended self-adjusting normal use position is in contact with the
   cheek or mouth of the phantom.




                           Figure 7.1c - Phone position 1, “cheek” or “touch” position.



   7.1.3 Tilt Position
   In the “cheek position”, if the earpiece of the device is not in full contact with the phantom’s ear spacer
   and the peak SAR location for the “cheek position” is located at the ear spacer region or corresponds
   to the earpiece region of the handset, the device is returned to the “initial ear position” by rotating it
   away from the mouth until the earpiece is in full contact with the ear spacer. Otherwise, the device is
   moved away from the cheek perpendicular to the line passes through both “ear reference points” for
   approximate 2-3cm. While it is in this position, the device is tilted away from the mouth with respect to
   the “test device reference point” by 15o. After the tilt, it is then moved back toward the head
   perpendicular to the line passes through both “ear reference point” until the device touches the
   phantom or the ear spacer. If the antenna touches the head first, the positioning process is repeated
   with a tilt angle less than 15o so that the device and its antenna would touch the phantom
   simultaneously.




                                 Figure 7.1d - Phone position 2, “tilted” position.




© 2012 Comptest Services LLC                        Page 22 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

   7.1.4 Body Worn Configuration
   Body worn accessories, when available, were tested for the FCC RF exposure compliance. The
   device was positioned into the carrying case and placed below the flat phantom. Hands-free headset
   was connected during measurements.

   The SAR levels were also measured with air space for the hands-free application, which allow user to
   use other body-worn accessories that contains no metal and provides at least specified separation
   from the closest point of the handset to the body.




  7.2 Scan Procedures
   First, coarse scans are used for a quick determination of the field distribution. Then an area scan
   measures all reachable points, it computes all of the field maxima found in the scanned area, within
   a range of 2dB as specified in IEEE P1528, (see the configuration below). For cases where
   multiple maxima were detected, the number of zoom scans could be increased accordingly.

   Next a cube scan, 7x7x7 points (spacing between each point is 5x5x5mm), is performed around the
   highest E-field value to determine the averaged SAR-distribution over 1g. If two peaks are within
   2dB of the highest one, two zoom scans are performed to provide the evaluations. A fine resolution
   volume scan determines the one-gram average SAR for both peaks.




  7.3 SAR Averaging Methods
   The maximum SAR value is average over its volume using interpolation and extrapolation.

   The interpolation of the points is done with a 3d-Spline. The 3d-Spline is composed of three one-
   dimensional splines with the “Not a knot” –condition [W. Gander, Computermathematik, p. 141-150]
   (x, y and z – directions) [numerical Recipes in C, Second Edition, p 123].

   The extrapolation is based on least square algorithm [W. Gander, Computermathematik, p. 168-
   180]. Through the points in the first 30mm in all z-axis, polynomials of order four are calculated.
   This polynomial is then used to evaluate the points between the surface and the probe tip. The
   points, calculated from the surface, have a distance of 1mm from one another.




© 2012 Comptest Services LLC                        Page 23 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                          Applicant:   Kyocera
                                                                           FCC ID:     V65C5155
                                                                          Report #:    CT-C5156-9-0712-R1


8       MEASUREMENT UNCERTAINTY

 Table 8.1 shows the uncertainty budget for SAR assessment according to IEEE P1528.
                                                                                        Stand.
                                                  Uncert    Prob                1                    2
                                                                              Ci        Uncert      Vi or
               Uncertainty Description            . Value     .     Div
                                                                              1g         (1g)        Veff
                                                    ( %)   Dist.
                                                                                         (%)
      Measurement system
      Probe calibration                             5.9       N      1         1         5.9          ∞
      Axial isotropy                                4.7       R      √3       0.7        1.9          ∞
      Hemispherical Isotropy                        9.6       R      √3       0.7        3.9          ∞
      Boundary effects                              1.0       R      √3        1         0.6          ∞
      Linearity                                     4.7       R      √3        1         2.7          ∞
      System Detection limit                        1.0       R      √3        1         0.6          ∞
      Readout Electronics                           0.3       N      1         1         0.3          ∞
      Response Time                                 0.8       R      √3        1         0.5          ∞
      Integration Time                              2.6       R      √3        1         1.5          ∞
      RF ambient conditions                         3.0       R      √3        1         1.7          ∞
      Mech. Constrains of robot                     0.4       R      √3        1         0.2          ∞
      Probe positioning                             2 9       R      √3        1         1.7          ∞
      Max. SAR Evaluation (ext., int., avg.)        1.0       R      √3        1         0.6          ∞
      Test Sample Related
      Device positioning                            3.0       N      1         1           .0         ∞
      Device Holder                                 3.6       N      1         1         3.6          ∞
      Power drift                                   5.0       N      √3        1         2.9          ∞
      Phantom and setup
      Phantom uncertainty                           4.0       R      √3        1         2.3          ∞
      Liquid conductivity (target)                  5.0       R      √3      0.64        1.8          ∞
      Liquid conductivity (meas.)                   3.5       N      1       0.64        2.2          ∞
      Liquid permittivity (target)                 5 0             √3     0.6             1.7         ∞
      Liquid permittivity (meas.)                   3.5     N      1      0.6             2.1         ∞
                                               Combined Standard Uncertainty:            11.0
                                          Extended Standard Uncertainty ( =2):           22.1

         N: Normal
         R: Rectangular

                        Table 8.1 Worst-Case uncertainty budget for SAR assessment




© 2012 Comptest Services LLC                        Page 24 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                        Applicant:    Kyocera
                                                                         FCC ID:      V65C5155
                                                                        Report #:     CT-C5156-9-0712-R1



9       TEST DATA

The following tables list the SAR results in each configuration and operating mode. The channels tested
for each configuration have similar SAR distributions. Highest SAR (bold blue color) plots for each
configuration is provided in Appendix B.

    9.1 Head SAR Test Results


    9.1.1   Cellular BC-0

            CDMA 800                                      Channel:        1013            384           777
            BC-0 HEAD                          Frequency (MHz):          824.70          836.49       848.31
                                                     Phone
       Mode        Test Position       Battery                                       SAR, 1g (W/kg)
                                                  Configuration
                     Left Cheek        Standard                             --            0.55           --

                      Left Tilt        Standard                             --            0.29           --
                                                        Closed
                    Right Cheek        Standard                             --            0.48           --

                      Right Tilt       Standard                             --            0.29           --
       RC3-
       SO55          Left Cheek        Standard                            0.98           0.96         0.91

                      Left Tilt        Standard                             --            0.26           --
                                                         Open
                    Right Cheek        Standard                             --            0.44           --

                      Right Tilt       Standard                             --            0.19           --

    Note:
    1. All modes of operation were evaluated and the worst case results are reported.
    2.     SAR Test Reduction procedures applied, marking “--“
    3. SAR measurements in open configuration next to ear are additional data for use conditions that could be
       possible but not expected to be a normal use configuration.




© 2012 Comptest Services LLC                        Page 25 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:    Kyocera
                                                                        FCC ID:      V65C5155
                                                                       Report #:     CT-C5156-9-0712-R1

   9.1.2   PCS BC-1

           CDMA 1900                                      Channel:         25            600           1175
           BC-1 HEAD                          Frequency (MHz):          1851.25          1880        1908.75
                                                    Phone
      Mode       Test Position        Battery                                       SAR, 1g (W/kg)
                                                 Configuration
                   Left Cheek        Standard                             1.17           1.36          1.36

                     Left Tilt       Standard                             0.76           0.90          0.77
                                                        Closed
                  Right Cheek        Standard                             0.73           0.93          0.93

                    Right Tilt       Standard                             0.75           0.90          0.71
      RC3-
      SO55         Left Cheek        Standard                             0.96           1.10          1.08

                     Left Tilt       Standard                               -            0.47            -
                                                         Open
                  Right Cheek        Standard                               -            0.51            -

                    Right Tilt       Standard                               -            0.55            -

   Note:
   1. All modes of operation were evaluated and the worst case results are reported.
   2.     SAR Test Reduction procedures applied, marking “--“
   3. SAR measurements in open configuration next to ear are additional data for use conditions that could be
      possible but not expected to be a normal use configuration.




© 2012 Comptest Services LLC                        Page 26 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:    Kyocera
                                                                        FCC ID:      V65C5155
                                                                       Report #:     CT-C5156-9-0712-R1

   9.1.3   WLAN Band

           WLAN 2450                                      Channel:          1              6            11
             HEAD                             Frequency (MHz):            2412           2437          2462
                                                    Phone
      Mode       Test Position        Battery                                       SAR, 1g (W/kg)
                                                 Configuration
                   Left Cheek        Standard                               --           0.06            --

                     Left Tilt       Standard                               --           0.07            --
                                                        Closed
                  Right Cheek        Standard                               --           0.07            --

                    Right Tilt       Standard                               --           0.13            --
     802.11b
                   Left Cheek        Standard                               --           0.01            --

                     Left Tilt       Standard                               --           0.05            --
                                                         Open
                  Right Cheek        Standard                               --           0.04            --

                    Right Tilt       Standard                               --           0.06            --

   Note:
   1. All modes of operation were evaluated and the worst case results are reported.
   2.     SAR Test Reduction procedures applied, marking “--“
   3. SAR measurements in open configuration next to ear are additional data for use conditions that could be
      possible but not expected to be a normal use configuration.




© 2012 Comptest Services LLC                        Page 27 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

  9.2 Body-Worn SAR Test Results


   9.2.1    Cellular BC-0


           CDMA 800                                         Channel:        1013          384          777
           BC-0 BODY                              Frequency (MHz):         824.70       836.49        848.31
                                    Spacing      Phone
       Mode         Accessory                                  Side                 SAR, 1g (W/kg)
                                     (mm)        Config.

                                                               Back           --          0.70           --
                                                  Closed
                                                               Front          --          0.44           --
       RC3 –
                        Air            15
       SO55
                                                               Back           --          0.70           --
                                                  Open
                                                               Front          --          0.52           --


   Note:
   1. Battery used:   Standard        Extended
   2. All modes of operation were evaluated and the worst case results are reported.
   3.     SAR Test Reduction procedures applied, marking “--“




© 2012 Comptest Services LLC                        Page 28 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:    Kyocera
                                                                        FCC ID:      V65C5155
                                                                       Report #:     CT-C5156-9-0712-R1

   9.2.2   PCS Band


           CDMA 1900                                      Channel:         25            600          1175
             BODY                               Frequency (MHz):        1851.25         1880         1908.75
                                   Spacing      Phone
        Mode        Accessory                                Side                   SAR, 1g (W/kg)
                                    (mm)        Config.

                                                             Back           --           0.75           --
                                                Closed
                                                             Front          --           0.49           --
       RC3 –
                         Air           15
       SO55
                                                             Back           --           0.48           --
                                                 Open
                                                             Front          --           0.31           --


   Note:
   1. Battery used:   Standard        Extended
   2. All modes of operation were evaluated and the worst case results are reported.
   3.     SAR Test Reduction procedures applied, marking “--“




© 2012 Comptest Services LLC                        Page 29 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

   9.2.3    WLAN Band


           WLAN 2450                                     Channel:          1             6            11
             BODY                              Frequency (MHz):          2412          2437          2462
                                   Spacing     Phone
       Mode         Accessory                               Side                 SAR, 1g (W/kg)
                                    (mm)       Config.

                                                            Back           --          0.09            --
                                                Closed
                                                            Front          --          0.02            --
      802.11b            Air          15
                                                            Back           --          0.03            --
                                                 Open
                                                            Front          --          0.03            --


   Note:
   1. Battery used:   Standard        Extended
   2. All modes of operation were evaluated and the worst-case results are reported.
   3.     SAR Test Reduction procedures applied, marking “--“
   4. The device does not support held-to-ear operation in WLAN/BT mode. Only Body-worn conditions apply.




© 2012 Comptest Services LLC                        Page 30 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1



10      SIMULTANEOUS SAR EVALUATION

  10.1 Summation of Highest Measured SAR Values

                                   Phone CLOSED, Head, 1g SAR (W/kg)
      Configuration                          CDMA                    WLAN                     SAR
      Left Cheek                                 1.36                   0.06                    1.42
      Left Tilt                                  0.90                   0.07                    0.97
      Right Cheek                                0.93                   0.07                    1.00
      Right Tilt                                 0.90                   0.13                    1.03
                                     Phone OPEN, Head, 1g SAR (W/kg)
      Configuration                           CDMA                   WLAN                     SAR
      Left Cheek                               1.10                   0.01                      1.11
      Left Tilt                                0.47                     0.05                    0.52
      Right Cheek                              0.51                     0.04                    0.55
      Right Tilt                               0.55                     0.05                    0.60


   Note:
   1. SAR Test was not required due to exclusions listed in section 4.7, marking “ ** “
   2. Volumetric SAR summation is not required since the numerical Sums are below the limits.




© 2012 Comptest Services LLC                        Page 31 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1

  10.2 Summation of Highest Scaled SAR Values

                                   Phone CLOSED, Head, 1g SAR (W/kg)
                                            CDMA at                WLAN at
      Configuration                                                                           SAR
                                            25.1 dBm               18.5 dBm
      Left Cheek                               1.52                   0.06                     1.58
      Left Tilt                                0.99                   0.07                     1.06
      Right Cheek                              1.01                   0.07                     1.08
      Right Tilt                               0.98                   0.13                     1.11


                                     Phone OPEN, Head, 1g SAR (W/kg)
                                            CDMA at                WLAN at
      Configuration                                                                           SAR
                                            25.1 dBm               18.5 dBm
      Left Cheek                               1.20                   0.01                     1.21
      Left Tilt                                0.51                   0.05                     0.56
      Right Cheek                              0.55                   0.04                     0.59
      Right Tilt                               0.60                   0.05                     0.65




   Note:
   1. SAR Test was not required due to exclusions listed in section 4.7, marking “ ** “
   2. Volumetric SAR summation is not required since the numerical Sums are below the limits.
   3. The highest measured SAR values are scaled to maximum rated output power (using formula: Scaled_
      SAR = Measured_SAR*10^(Power Delta/10)) at following modes:
       CDMA: 25.1 dBm,
       WLAN: 18.5dBm.




© 2012 Comptest Services LLC                        Page 32 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.


                                                                       Applicant:   Kyocera
                                                                        FCC ID:     V65C5155
                                                                       Report #:    CT-C5156-9-0712-R1



11       LIST OF APPENDIX

Appendix Description                                                     Note
     A       Validation Test Plots                                       Please see separate attachment
     B       SAR Distribution Plots                                      Please see separate attachment
     C       Probe Calibration Certificate                               Please see separate attachment
     D       Dipole Calibration Certificate                              Please see separate attachment
     E       EUT Setup Photos                                            Please see separate attachment




© 2012 Comptest Services LLC                        Page 33 of 33                                     SAR Report
    This report shall not be reproduced except in full, without the written consent of CompTest Services LLC.



Document Created: 2012-08-28 14:40:40
Document Modified: 2012-08-28 14:40:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC