RF Exposure Report

FCC ID: V5PQ30

RF Exposure Info

Download: PDF
FCCID_3501769

                      Test Report No.: SA170704W004



                                      RF EXPOSURE REPORT
                        Product: POS Terminal

             Model Name: Q30
                         FCC ID: V5PQ30
                    Applicant: PAX Technology Limited
                       Address: Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road,
                                Wanchai, Hong Kong
            Manufacturer: PAX Computer Technology (Shenzhen) Co., Ltd.
                       Address: 4/F, No.3 Building, Software Park, Second Central
                                Science-Tech Road, High-Tech industrial Park, Shenzhen,
                                Guangdong, P.R.C.
              Prepared by: Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch
            Lab Location: No. 34, Chenwulu Section, Guantai Rd., Houjie Town,
                          Dongguan City, Guangdong 523942, China
                                TEL: +86 769 8593 5656
                                FAX: +86 769 8593 1080
                         E-MAIL: customerservice.dg@cn.bureauveritas.com
                 Report No.: SA170704W004
         Received Date: Jun. 30, 2017
                    Test Date: Jul. 01, 2017 ~ Jul. 10, 2017
               Issued Date: Jul. 11, 2017

                                                                                         This report should not be used by the client to claim
                                                                                         product certification, approval, or endorsement by
                                                                                         A2LA or any government agencies.

 Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written
 permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
 representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
 expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have
 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice
 shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
 unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
 uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.




                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie                      Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                               Fax: +86 769 8593 1080
Dongguan Branch                                     Guangdong 523942, China                                            Email: customerservice.dg@cn.bureauveritas.com

                                                                                  Page 1 of 9                                                       Report Version 1


                  Test Report No.: SA170704W004


                                    TABLE OF CONTENTS

 RF EXPOSURE REPORT............................................................................................. 1
 RELEASE CONTROL RECORD .................................................................................. 3
 1     CERTIFICATION .................................................................................................... 4
 2     GENERAL INFORMATION .................................................................................... 5
   2.1 GENERAL DESCRIPTION OF EUT ................................................................... 5
 3 RF EXPOSURE ...................................................................................................... 6
     3.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ............................ 6
     3.2 MPE CALCULATION FORMULA ....................................................................... 6
     3.3 CLASSIFICATION .............................................................................................. 6
     3.4 CONDUCTED POWER ...................................................................................... 7
     3.5 CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ..................... 9




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                           Page 2 of 9                                        Report Version 1


                  Test Report No.: SA170704W004




                                    RELEASE CONTROL RECORD

   ISSUE NO.               REASON FOR CHANGE                                                         DATE ISSUED
   SA170704W004            Original release                                                          Jul. 11, 2017




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                          Page 3 of 9                                        Report Version 1


                  Test Report No.: SA170704W004




 1 CERTIFICATION

                   PRODUCT: POS Terminal
            BRAND NAME: PAX
            MODEL NAME: Q30
                APPLICANT: PAX Technology Limited
                      TESTED: Jul. 01, 2017 ~ Jul. 10, 2017
           TEST SAMPLE: Production Unit
             STANDARDS: FCC Part 2 (Section 2.1091)
                                    FCC OET Bulletin 65, Supplement C (01-01)
                                    KDB 447498 D01 General RF Exposure Guidance v06
                                    IEEE C95.1




 The above equipment has been tested by Bureau Veritas Shenzhen Co., Ltd.
 Dongguan Branch and found compliance with the requirement of the above
 standards. The test record, data evaluation & Equipment Under Test (EUT)
 configurations represented herein are true and accurate accounts of the
 measurements of the sample’s EMC characteristics under the conditions specified in
 this report.




     PREPARED BY :                                                         ,   DATE:            Jul. 11, 2017
                                      (Harry Li/ Engineer)




     APPROVED BY :                                                         ,   DATE:            Jul. 11, 2017
                                    ( Sam Tung / Manager)



                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                         Page 4 of 9                                        Report Version 1


                  Test Report No.: SA170704W004


 2 GENERAL INFORMATION
 2.1     GENERAL DESCRIPTION OF EUT
  PRODUCT                           POS Terminal
  MODEL NAME                        Q30
  NOMINAL VOLTAGE   5.0Vdc (adapter or host equipment)
  OPERATING
                    0 ~ 40℃
  TEMPERATURE RANGE
                                        CCK, DQPSK, DBPSK for DSSS
                    WLAN
                                        64QAM, 16QAM, QPSK, BPSK for OFDM
                                    Bluetooth                GFSK, π/4-DQPSK, 8DPSK
  MODULATION TYPE
                                    BT_LE                    BT-LE(GFSK) for DTS
                                    NFC                      ASK

                                    WLAN                     2412 ~ 2462MHz for 11b/g/n(HT20)
  OPERATING
  FREQUENCY                         Bluetooth/BT_LE 2402MHz ~ 2480MHz
                                    NFC                      13.56MHz

  ANTENNA GAIN                      PCB Antenna with 0.6dBi gain
  HW VERSION                        Q30-XXX-XXX-XXXX
  SW VERSION                        PED4.0
  I/O PORTS                         Refer to user’s manual
  CABLE SUPPLIED                    N/A
 NOTE:
 1. For a more detailed features description, please refer to the manufacturer’s specifications or the
    user's manual.
 2. The EUT was powered by the following adapter:
    ADAPTER
    BRAND:                   N/A
    MODEL:                   HKA00505010-2P
    INPUT:                   AC 100-240V, 250mA
    OUTPUT:                  DC 5V, 1000mA
    MANUFACTURER: SHENZHEN HUNKEY ELECTRIC CO., LTD
 3. For the test results, the EUT had been tested with all conditions. But only the worst case was
     shown in test report.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                         Page 5 of 9                                        Report Version 1


                  Test Report No.: SA170704W004



 3       RF EXPOSURE
 3.1     LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
     FREQUENCY              ELECTRIC FIELD       MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
                                                                        2
     RANGE (MHz)            STRENGTH (V/m)       STRENGTH (A/m)   (mW/cm )                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
        300-1500                    …                      …                        F/1500                        30
     1500-100,000                   …                      …                         1.0                          30

 F = Frequency in MHz

 3.2     MPE CALCULATION FORMULA
 Pd = (Pout*G) / (4*pi*r2)
 where
 Pd = power density in mW/cm2
 Pout = output power to antenna in mW
 G = gain of antenna in linear scale
 Pi = 3.1416
 R = distance between observation point and center of the radiator in cm


 3.3     CLASSIFICATION

 The antenna of this product, under normal use condition, is at least 20cm away from
 the body of the user. So, this device is classified as Mobile device.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch                     Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com

                                                         Page 6 of 9                                         Report Version 1


                  Test Report No.: SA170704W004

 3.4     CONDUCTED POWER
 WIFI 2.4G


   802.11b

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    1               2412            15.35               N/A
                                    6               2437            15.20               N/A
                                    11              2462            15.17               N/A

   802.11g

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    1               2412            14.58               N/A
                                    6               2437            14.53               N/A
                                    11              2462            14.26               N/A

   802.11n (20MHz)

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    1               2412            13.65               N/A
                                    6               2437            12.85               N/A
                                    11              2462            12.37               N/A




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch                         Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 7 of 9                                         Report Version 1


                  Test Report No.: SA170704W004



 Bluetooth

   GFSK

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    0               2402             8.63               N/A
                                    39              2441             8.84               N/A
                                    78              2480             8.52               N/A

   DQPSK

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    0               2402             4.91               N/A
                                    39              2441             5.53               N/A
                                    78              2480             4.68               N/A

   8DPSK

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    0               2402             4.90               N/A
                                    39              2441             5.27               N/A
                                    78              2480             4.46               N/A



 BT-LE (GFSK)

                                        CHANNEL AVERAGE
                               CHANNEL FREQUENCY POWER  PASS/FAIL
                                          (MHz)   (dBm)
                                    0               2402             7.46               N/A
                                    19              2440             7.17               N/A
                                    39              2480             6.80               N/A




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch                         Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 8 of 9                                         Report Version 1


                     Test Report No.: SA170704W004



    3.5     CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

    BT & WIFI 2.4G

                                       Antenna        Tune-up         E.I.R.P       Power
            Frequency Operating                                                               limit   PASS /
  Band                                  Gain           Power          Power         Density
               (MHz)   Mode                                                                 (mW/cm^2) FAIL
                                        (dBi)          (dBm)           (mW)       (mW/cm^2)

Bluetooth       2441       BT_GFSK        0.6            9.0           9.120           0.002             1.00          PASS
WIFI 2.4G       2412           11b        0.6           15.5          40.738           0.008             1.00          PASS




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
   Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
   Dongguan Branch                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com

                                                            Page 9 of 9                                         Report Version 1



Document Created: 2017-08-02 10:50:13
Document Modified: 2017-08-02 10:50:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC