Test report

FCC ID: V5PIM30BW

Test Report

Download: PDF
FCCID_4434518

                       Shenzhen ZhongjianNanfang Testing Co., Ltd.
                                                                                 Report No: CCISE190704306V01

1        Cover Page

                              FCC REPORT
    Applicant:                          PAX Technology Limited
    Address of Applicant:  Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road,
                           Wanchai, Hong Kong
    Equipment Under Test (EUT)

    Product Name:                       POS Terminal
    Model No.:                          IM30
    Trade mark:                         PAX
    FCC ID:                             V5PIM30BW
    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.225

    Date of sample receipt:             11 Jul., 2019
    Date of Test:                       11 Jul., to 16 Aug., 2019
    Date of report issue:               05 Step., 2019
    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




Bruce Zhang
   Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                            Report No: CCISE190704306V01


2      Version
      Version No.                        Date                                   Description
            00                     19 Aug., 2019                                  Original
            01                     05 Step., 2019                           Update page 11~13




    Tested by:                                                          Date:          05 Step., 2019

                                       Test Engineer

    Reviewed by:                                                        Date:          05 Step., 2019

                                    Project Engineer




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                         Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                        Page 2 of 24


                                                                                                                 Report No: CCISE190704306V01



3         Contents
                                                                                                                                                                           Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1       CLIENT INFORMATION ............................................................................................................................................ 5
    5.2       GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3       TEST MODE ............................................................................................................................................................ 6
    5.4       MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.5       DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.6       LABORATORY FACILITY.......................................................................................................................................... 6
    5.7       LABORATORY LOCATION ....................................................................................................................................... 6
    5.8       TEST INSTRUMENTSLIST........................................................................................................................................ 7
6     TEST RESULTS ANDMEASUREMENT DATA ................................................................................................. 8
    6.1       ANTENNA REQUIREMENT ....................................................................................................................................... 8
    6.2       RADIATED EMISSION ............................................................................................................................................. 9
    6.3       20DB BANDWIDTH ............................................................................................................................................... 16
    6.4       FREQUENCY TOLERANCE .................................................................................................................................... 18
    6.5       CONDUCTED EMISSION ....................................................................................................................................... 20
7     TEST SETUP PHOTOS...................................................................................................................................... 23
8     EUT CONSTRUCTIONAL PHOTOS ................................................................................................................. 24




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                                                                        Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                  Page 3 of 24


                                                                                 Report No: CCISE190704306V01

4      Test Summary
                    Test Item                                 Section in CFR 47                      Result
              Antenna requirement                                       15.203                        Pass
    Field strength of the fundamental signal                       15.225 (a)                         Pass
               Spurious emissions                             15.225(d)& 15.209                       Pass
                20dB Bandwidth                                     15.215(c)                          Pass
              Frequency tolerance                                  15.225 (e)                         Pass
              Conducted Emission                                        15.207                        Pass
 Remarks:
 Pass: The EUT complies with the essential requirements in the standard.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                             Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 4 of 24


                                                                         Report No: CCISE190704306V01


5      General Information
5.1 Client Information
         Applicant:                     PAX Technology Limited
         Address:                       Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road, Wanchai,
                                        Hong Kong
         Manufacturer/ Factory:         PAX Computer Technology(Shenzhen) Co. Ltd.
         Address:                       401-402 No.3 Building, Software Park, Nanshan district, Shenzhen,
                                        Guangdong, P.R.C.

5.2 General Description of E.U.T.
         Product Name:                  POS Terminal
         Model No.:                     IM30
         Operation Frequency:           13.56MHz
         Channel numbers:               1
         Modulation type:               ASK
         Antenna Type:                  Induction Coil Antenna
         IC Card Type:                  Support: Type A, Type B, Type M
         Power supply:                  DC 12V-48V
         Test Sample Condition:         The test samples were provided in good working order with no visible
                                        defects.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                         Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 5 of 24


c c I s                                                                      Report No: CCISE190704306V01

5.3 Test mode
      Transmitting mode:               Keep the EUT in transmitting mode with modulation
  Pre—Test Mode:
  CCIS has verified the construction and function in typical operation,The EUT was placed on three different
  polar directions;i.e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
               Axis                            X                         Y                            Z
    Field Strength(dBuV/m)                  59.33                       59.95                       §8.21
  Final Test Mode:
  According to ANSI C63.4 standards, the test results are both the "worst case" and "worst setup": Y axis
  (see the test setup photo).

5.4 Measurement Uncertainty
                   Parameters                                                Expanded Uncertainty
        Conducted Emission (@kHz ~ 30MHz)                                       +1.60 dB (k=2)
           Radiated Emission (OkHz ~ 3OMHz)                                     +3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                      +4.32 dB (k=2)

5.5 Description of Support Units
    Manufacturer              Description                    Model              Serial Number        FCC ID/DoC

       HONOR                  AC Adapter            ADS—65H1—19A—2 24065E             N/A                   N/A

5.6      Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ®@ FCC — Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        @ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
        @ CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
       ®     A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https //portal. a2la.org/scopepdf/4346—0 1 .pdf

5.7 Laboratory Location
         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
         Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
         Bao‘an District, Shenzhen, Guangdong, China
         Tel: +86—755—23118282, Fax: +86—755—23116366
         Email: info@ccis—cb.com, Website: http:/Avww.ccis—cb.com




Shenzhen ZhongjianNantang Testing Co., Ltd.                                            Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 6 of 24


                                                                           Report No: CCISE190704306V01

5.8 Test Instrumentslist
 Radiated Emission:
                                                                                           Cal.Date       Cal. Due date
   Test Equipment           Manufacturer               Model No.          Serial No.
                                                                                          (mm-dd-yy)       (mm-dd-yy)
      3m SAC                  SAEMC                    9m*6m*6m              966          07-22-2017       07-21-2020
  BiConiLog Antenna        SCHWARZBECK                 VULB9163              497          03-18-2019       03-17-2020
  Biconical Antenna        SCHWARZBECK                 VUBA9117              359          06-22-2017       06-21-2020
    Horn Antenna           SCHWARZBECK                BBHA9120D              916          03-18-2019       03-17-2020
    Horn Antenna           SCHWARZBECK                BBHA9120D             1805          06-22-2017       06-21-2020
    Horn Antenna           SCHWARZBECK                BBHA 9170          BBHA9170582      11-21-2018       11-20-2019
    Loop Antenna          SCHWARZBECK                FMZB 1519 B            00044      03-18-2019          03-17-2020
  EMI Test Software           AUDIX                      E3                         Version: 6.110919b
    Pre-amplifier               HP                     8447D             2944A09358    03-18-2019          03-17-2020
    Pre-amplifier               CD                    PAP-1G18              11804      03-18-2019          03-17-2020
  Spectrum analyzer       Rohde & Schwarz              FSP30               101454      03-18-2019          03-17-2020
  Spectrum analyzer       Rohde & Schwarz              FSP40               100363      11-21-2018          11-20-2019
  EMI Test Receiver       Rohde & Schwarz              ESRP7                101070         03-18-2019      03-17-2020
  Signal Generator        Rohde & Schwarz               SMX              835454/016        03-18-2019      03-17-2020
  Signal Generator             R&S                     SMR20             1008100050        03-18-2019      03-17-2020
       Cable                  ZDECL                 Z108-NJ-NJ-81          1608458         03-18-2019      03-17-2020
       Cable               MICRO-COAX                 MFR64639             K10742-5        03-18-2019      03-17-2020
       Cable                 SUHNER                 SUCOFLEX100           58193/4PE        03-18-2019      03-17-2020

 Conducted Emission:
                                                                                          Cal.Date     Cal.Due date
   Test Equipment           Manufacturer               Model No.         Inventory No.
                                                                                        (mm-dd-yy)      (mm-dd-yy)
   Shielding Room        ZhongShuo Electron      11.0(L)x4.0(W)x3.0(H)    CCIS0061      07-22-2017      07-21-2020
  EMI Test Receiver       Rohde & Schwarz                ESCI             CCIS0002      03-18-2019      03-17-2020
        LISN                  CHASE                    MN2050D            CCIS0074      03-18-2019      03-17-2020
                                                                                        07-21-2018      07-20-2021
         LISN             Rohde & Schwarz               ESH3-Z5          8438621/010
                                                                                        07-21-2019      07-20-2020
   Coaxial Cable                CCIS                      N/A             CCIS0086      03-18-2019      03-17-2020
  EMI Test Software             AUDIX                     E3                         Version: 6.110919b




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                              Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 7 of 24


                                                                        Report No: CCISE190704306V01



6      Test results andMeasurement Data
6.1 Antenna requirement
        Standard requirement:          FCC Part15 C Section 15.203
      15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
       E.U.T Antenna:
       The EUT make use of an Induction coil antenna.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                       Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                       Page 8 of 24


                                                                             Report No: CCISE190704306V01

6.2 Radiated Emission
        Test Requirement:               FCC Part15 C Section 15.225(a) and 15.209
        Test Method:                    ANSI C63.10: 2013
        TestFrequencyRange:             9 kHz to 1000MHz
        Test site:                      Measurement Distance: 3m(Semi-Anechoic Chamber)
        Receiver setup:                    Frequency          Detector        RBW          VBW            Remark
                                          9kHz-150kHz        Quasi-peak      200Hz        600Hz       Quasi-peak Value
                                         150kHz-30MHz        Quasi-peak       9kHz        30kHz       Quasi-peak Value
                                          30MHz-1GHz         Quasi-peak      120kHz      300KHz       Quasi-peak Value
                                          Above 1GHz           Peak           1MHz        3MHz          Peak Value
        Limit:                                  Frequency                 Limit (uV/m @30m)       Limit (dBuV/m @3m)
        (Field strength of the            13.553MHz-13.567MHz                   15848                      124.0
        fundamental signal)              13.410MHz-13.553MHz &
                                                                                  334                      90.5
                                          13.567MHz-13.710MHz
                                         13.110MHz-13.410MHz &
                                                                                  106                      80.5
                                          13.710MHz-14.010MHz
                                        Remark: Per FCC part 15.31, when performingmeasurements at a closer
                                        distancethan specified, the results shallbe extrapolated to the specified
                                        distanceby either making measurementsat a minimum of two distances on atleast
                                        one radial to determine the properextrapolation factor or by using thesquare of an
                                        inverse linear distance extrapolationfactor (40 dB/decade).
        Limit:                                Frequency (MHz)               Limit (uV/m @3m)             Distance (m)
        (Spurious Emissions)                    0.009-0.490                    2400/F(kHz)                   300
                                                0.490-1.705                   24000/F(kHz)                    30
                                                  1.705-30                           30                       30
                                                    30-88                           100                       3
                                                   88-216                           150                       3
                                                  216-960                           200                       3
                                                Above 1GHz                          500                       3
        Test Procedure:                 a. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the groundat a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees todetermine the position of the highest radiation.
                                        b. The EUT was set 3 meters away from the interference-receiving
                                           antenna, whichwas mounted on the top of a variable-height antenna
                                           tower.
                                        c. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make
                                           the measurement.
                                        d. For each suspected emission, the EUT was arranged to its worst case
                                           and thenthe antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatabletable was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        e. The test-receiver system was set to Peak Detect Function and
                                           SpecifiedBandwidth with Maximum Hold Mode.
                                        f. If the emission level of the EUT in peak mode was 10dB lower than
                                           the limitspecified, then testing could be stopped and the peak values
                                           of the EUT wouldbe reported. Otherwise the emissions that did not
                                           have 10dB margin would bere-tested one by one using peak, quasi-
                                           peak or average method as specified andthen reported in a data
                                           sheet.
        Test setup:                     9kHz-30MHz



Shenzhen ZhongjianNanfang Testing Co., Ltd.                                               Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 9 of 24


                                                                           Report No: CCISE190704306V01




                                        30MHz-1GHz




                                        Above 1GHz




        Test Instruments:               Refer to section 5.7 for details
        Test mode:                      Refer to section 5.3 for details
        Measurement Record:                                                              Uncertainty:±4.88 dB
        Test results:                   Pass




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                       Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                     Page 10 of 24


c c I s                                                                            Report No: CCISE190704306V01

Measurement Data:
Field Strength of fundamental signal:
Product Name:                     POS Terminal                      Product Model:           IM30
Test By:                          Mike                              Test mode:               NFC Tx moade

Test Voltage:                     AC 120/60Hz                       Environment:             Temp: 24°C       Huni: 57%


           110Level (dBuVim)

           100



               so                                                                      power
                                                                                    15225    umt

               60                                               i

                                                     w
            40
                    M/—\M/'\Mh/\,_/\/\                   J\\/                            WeHrmvemtecrmemce)


               20



                    1311    132                          13.5                                                 14.01
                                                         Frequency (MHz)




                                      Read&ntenna   Cable Preamp                    Limit     Over
                            Freq     Level Factor    Loss Factor           Level     Line    Limit Remark

                    ______MHz dBu¥y dB/mdb — dB dBu¥/m dBu¥/m                                  db —
           1               13.560    34.28 —26.47    0.64       0.00       59.95 124.00 —64.05 Peak




Remark:
1. _Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                 Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 11 of 24


CCIS                                                                                   Report No: CCISE190704306V01

Spurious Emissions:
Test frequency range: 9 kHz— 30 MHz

Product Name:               POS Terminal                               Product Model:             IM30
Test By:                    Mike                                       Test mode:                 NCF Tx mode

Test Frequency:             150 kHz ~ 30 MHz                           Polarization:              Vertical

Test Voltage:               AC 120/60Hz                                Environment:               Temp: 24°C        Huni: 57%


           110l.\t§el (dBuVim)
                     *
           100}          *\\5
                                          PBALL_
              so|                                  ~bBhas,                             Fundamental signal




                                                             Frequency (MHz)

                                   ReadiAnt enna     Cable Preamp                       Limit      Over
                         Freq    Level Factor          Loss Factor             Level      Line    Limit Remark

                    ~— NHz
                        MHz dBu¥
                              dBu¥ dB/mdb
                                    dB/m  _dB dBu¥/m dBu¥/m —db —
          1           0.0098     27.40    —25.60       0.02         0.00       53.32 108         —54. 68     Peak
          2           0. 014     28.03    —25.85       0.04        0.00        53.72 104         —50. 59     Peak
          3           0. 021     27. 53   —25.90       0.06        0.00        53.19 100         —47.57      Peak
          4           0.031      23.09    —25.95       0.12        0.00        48.76 97          —48. 37     Peak
          5           0. 156     23.30    —26.16       0.28        0.00        48.92 83          —34. 15     Peak
          6           0. 495     15. 24   —26.30       0.45        0.00        40.89 52          —12. 03     Peak


Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of 9 kHz~150 kHz are background noise and very lower than the limit, not show in test report.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                      Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 12 of 24


c c I s                                                                            Report No: CCISE190704306V01


Product Name:                POS Terminal                             Product Model:                   IM30
Test By:                     Mike                                     Test mode:                       NFC Tx moade

Test Frequency:              150 kHz ~ 30 MHz                         Polarization:                    Horizontal

Test Voltage:                AC 120/60Hz                              Environment:                     Temp: 24°C             Huni: 57%


              Level (dBuVim)
          110 ’\\_\
          100                L1
                                           SA

           89                                                                      Fundamental signal


           60) ,
                                                                                                                   FCjp 9K—30M

           40


           20



                .009   .02           .05     A       2          $          1           2           5          10         20      30
                                                          Frequency (MHz)


                                 Readéntenna         Cable Preamp                          Limit        Over
                        Freq    Level Factor          Loss Factor              Level        Line       Limit Remark

                   """"""NHz dBu¥ dB/mdb — dB dBu¥/m dBu¥/m —db —
           1           0.010        28.36   —25.80       0.03       0.00       54.09 107.08 —52.99 Peak
           2           0.015        27.10   —25.85       0.04       0.00       52.179 103.81 —51.02 Peak
           3           0.031        24.21   —25.95       0.12       0.00       49.88 97.06 —47.18 Peak
           4           0.154        23.87   —26.16       0.27       0.00       49.48 83.14 —33.66 Peak
           5           0. 317       20.90   —26.25       0.36       0.00       46.51 T76.82 —30.31 Peak
           6           0.564        17.15   —26.30       0.50       0.00       42.85 51.88 —9.03 Peak


Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of 9 kHz~150 kHz are background noise and very lower than the limit, not show in test report.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                        Project No.: CCISE1907043
No.B—C, 1/F. ., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                             Page 13 of 24


CCIS                                                                              Report No: CCISE190704306V01

Test frequency range: 30MHz—1000MHz

Product Name:              POS Terminal                              Product Model:             IM30
Test By:                   Mike                                      Test mode:                 NFC Tx moade

Test Frequency:            30 MHz ~ 1 GHz                            Polarization:             Vertical

Test Voltage:              AC 120/60Hz                               Environment:              Temp: 24°C           Huni: 57%


           go Level (dBuVim)

           70

           60
                                                                                                FCC PART15 CLAS$ 8
           50

           40

           30

           20

           10

                30         50                   100                 200                         500                  1000
                                                          Frequency (MHz)

                                 Read&ntenna          Cable Preanp                   Limit       Over
                        Freq    Level Factor           Loss Factor          Level     Line      Limit Remark

                 ''''''NHz dBu¥y dB/mdbdb dBu¥/m dBu¥/m —db —
           1          45.375    44.42      12.28       1.29     29.86       28.13    40.00    —11.87       QP
           2          86.503    47.31       9. 07      1.91     29.59       28.T0    40.00    —11.30       QP
           3         117. 360   47.04      11.07       2.13     29.41       30.83    43.50    —12.67       QP
           4         149.486    47.90       8.94       2.§1     29.22       30.13    43.50    —13.37       QP
           5         242.525    46.77      12.42       2.82     28.58       33.43    46.00    —12.57       QP
           6         654.232    36.80      19.78       3.89     28.77       31.170   46.00    —14.30       QP


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                   Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 14 of 24


CCIS                                                                             Report No: CCISE190704306V01


Product Name:                 POS Terminal                          Product Model:             IM30
Test By:                      Mike                                  Test mode:                 NFC Tx moade

Test Frequency:               30 MHz ~ 1 GHz                        Polarization:              Horizontal

Test Voltage:                 AC 120/60Hz                           Environment:              Temp: 24°C             Huni: 57%


           80Level (dBuVim)


           70

           60


           4——————H———t————EECCD
                                                                                              FCC PART1S CLAS$ 8



           40
                                                                                                                 6
           30

           20

           10


                30            50                100                200                        500                    1000
                                                         Frequency (MHz)

                                    Read&ntenna       Cable Preamp                  Limit       Over
                           Freq    Level Factor         Loss Factor        Level     Line      Limit Remark

                     ~       NBz     dBu¥y    db/mdb                dB dBu¥/m dBu¥/m _              db
           1             116.950   45.60     i1.11     2.13    29.41       29.43    43.50    —14.07       QP
           2             186.441   49.56     10.18     2.77    28.93       33.58    43.50     —9.92       QP
           3             243.377   46.02     12.42     2.82    28.58       32.68    46.00    —13.32       QP
           4             301.422   44.51     13.63     2.94    28.45       32.63    46.00    —13.37       QP
           5             502.940   41.07     18.21     3.64    28.96       33.96    46.00    —12.04       QP
           6             848.056   33.21     22.60     4.20    28.01       32.00    46.00    —14.00       QP


Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                  Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 15 of 24


                                                                           Report No: CCISE190704306V01

6.3 20dB Bandwidth
        Test Requirement:               FCC Part15 C Section 15.215 (c)
        Test Method:                    ANSI C63.4:2014
        Receiver setup:                 RBW=200Hz, VBW=300Hz, detector: Peak
        Limit:                          The fundamental emission be kept within atleast the central 80% of the
                                        permitted band
        Test Procedure:                 1. According to the follow Test-setup, keep the relative position between
                                           the artificial antenna and the EUT.
                                        2. Set the EUT to proper test channel.
                                        3. Max hold the radiated emissions, mark the peak power frequency
                                           point and the -20dB upper and lower frequency points.
                                        4. Read 20dB bandwidth.
        Test setup:




        Test Instruments:               Refer to section 5.7 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed


Measurement Data
        20dB bandwidth (kHz)                           Limit (kHz)                          Results
                 0.600                                     11.2                             Passed
 Note: For 13.56MHz, permitted Band is 14 kHz, so the Limit is 11.2 kHz.




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                         Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                        Page 16 of 24


                                                                                                     Report No: CCISE190704306V01

 Test plot as follows:
                                                                          * RBW       200 Hz   Delta 1 [T1 ]
                                                                          * VBW       300 Hz              -0.30 dB
                           Ref    0 dBm               * Att   20 dB        SWT 125 ms             600.000000000 Hz

                           0     Offset    1 dB                                                Marker 1 [T1 ]
                                                                                                         -48.56 dBm
                                                                                                   13.559790000 MHz    A
                           -10

                    1 PK
                    MAXH
                           -20
                                                                                                                      LVL


                                    D1 -28.33 dBm
                           -30



                           -40

                                                                      1           1
                                          D2 -48.33 dBm
                           -50


                                                                                                                      6DB
                           -60



                           -70



                           -80



                           -90


                           -100

                           Center 13.56 MHz                           500 Hz/                            Span 5 kHz




                    Date: 24.JUL.2019             19:17:27




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                                                           Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                         Page 17 of 24


CCIS                                                                                Report No: CCISE190704306V01

6.4 Frequency Tolerance
        Test Requirement:                FCC Part15 C Section 15.225 (e)
        Test Method:                     ANSI ©63.10: 2013
        Receiver setup:                  RBW=200Hz, VBW=300Hz, span=14kHz, detector: Peak
        Limit:                           +0.01% of the operating frequency
        Test mode:                       Transmitting mode
        Test Procedure:                       Frequency stability V.S. Temperature measurement
                                         1.   The equipment under test was powered by a fresh battery.
                                         2.   RF output was connected to spectrum analyzer via feed through
                                              attenuators.
                                         3.   The EUT was placed inside the temperature chamber.
                                         4.    Set the spectrum analyzer RBW low enough to obtain the desired
                                              frequency resolution and measure EUT 20°C operating frequency as
                                              reference frequency.
                                         5.   Turn EUT off and set the chamber temperature to —20°C. After the
                                              temperature stabilized for approximately 30 minutes recorded the
                                              frequency.
                                         6.   Repeat step measure with 10°C increased per stage until the highest
                                              temperature of +50°C reached
                                              Frequency stability V.S. Voltage measurement
                                         1.    Set chamber temperature to 25°C. Use a variable DC power source
                                              to power the EUT and set the voltage to rated voltage.
                                         2.   Set the spectrum analyzer RBW low enough to obtain the desired
                                              frequency resolution and recorded the frequency.
                                              Reduce the input voltage to specify extreme voltage variation (+/—
                                              15%) and endpoint, record the maximum frequency change.
        Test setup:                               Spectrum Analyzer
                                                             ==I=
                                                             ==I=
                                                             ==I=

                                                             aat                  E.U.T
                                                                                               1
                                                            Non—Conducted Table




                                                           Ground Reference Plane


        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                                Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong.China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 18 of 24


CCIS                                                                              Report No: CCISE190704306V01

Measurement Data:
a) Frequency stability V.S. Temperature measurement
    Voltage         Temperature
                         <            Frequency Tolerance        Frequency Error          Limit
                                                                                                          Results
      (Vdc)              (C)                  (MHz)                    (%)                 (%)
                         20                   0.082                  0.0060               0.01             Pass
                         —10                  0.076                  0.0056               0.01             Pass
                          0                   —0.075                 —0.0055              0.01             Pass
      24.0               +10                  0.081                  0.0060               0.01             Pass
         —               +20                  —0.079                 —0.0058              0.01             Pass
                         +30                  0.062                  0.0046               0.01             Pass
                         +40                  0.079                  0.0058               0.01             Pass
                         +50                  —0.042                  —0.003              0.01             Pass

b) Frequency stability V.S. Voltage measurement
 Temperature           Voltage        Frequency Tolerance        Frequency Error          Limit           R
       —                                                                                                      esults
      (°C)              (Vde)                 (MHz)                       (%)              (%)
                         10.2                 —0.085                    —0.0068           0.01             Pass
       25               24.0                  0.071                     0.0054            0.01             Pass
                        55.2                  0.092                     0.0066            0.01             Pass




Shenzhen ZhongjianNantang Testing Co., Ltd.                                              Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 19 of 24


                                                                                Report No: CCISE190704306V01

6.5 Conducted Emission
        Test Requirement:                FCC Part15 B Section 15.207
        Test Method:                     ANSI C63.4:2014
        TestFrequencyRange:              150kHz to 30MHz
        Class / Severity:                Class B
        Receiver setup:                  RBW=9kHz, VBW=30kHz
        Limit:                                                                              Limit (dBµV)
                                          Frequency range (MHz)
                                                                             Quasi-peak                     Average
                                                 0.15-0.5                     66 to 56*                     56 to 46*
                                                   0.5-5                          56                           46
                                                  0.5-30                          60                           50
                                         * Decreases with the logarithm of the frequency.
        Test setup:




        Test procedure                   1. The E.U.T and simulators are connected to the main power through a line
                                            impedance stabilization network (L.I.S.N.).It provide a 50ohm/50uH coupling
                                            impedance for the measuring equipment.
                                         2. The peripheral devices are also connected to the main power through a LISN
                                            that provides a 50ohm/50uH coupling impedance with 50ohm termination.
                                            (Please refer to the block diagram of the test setup and photographs).
                                         3. Both sides of A.C. line are checked for maximum conducted interference. In
                                            order to find the maximum emission, the relative positions of equipment and all
                                            of the interface cables must be changed according to ANSI C63.4: 2003 on
                                            conducted measurement.
        Test environment:                Temp.:        23C           Humid.:     56%             Press.:     101kPa
        Measurement Record:                                                                         Uncertainty: 3.28dB
        Test Instruments:                Refer to section 5.7 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Pass




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                                 Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 20 of 24


CCIS                                                                                                   Report No: CCISE190704306V01

Measurement Data:
Product name:                                           POS Terminal                      Product model:      IM30
Test by:                                                Mike                              Test mode:          NFC Tx mode

Test frequency:                                         150 kHz ~ 30 MHz                  Phase:              Line

Test voltage:                                           AC 120 V/60 Hz                    Environment:        Temp: 22.5°C     Huni: 55%


                                             Level (dBuV)
                          80,

                          70

                        so                                                                                           FCC PART15 B OP
                                               ~—L_
                                                                                                                     FCC PART15 B AV
                          50




                                                                                  Frequency (MHz)


                                                                Read   LISN      Cable              Limit     Over
                                                       Freq    Level Factor       Loss    Level      Line    Limit Remark

                                                        MHz     dBu¥        dB      dB     dBu¥      dBu¥

                                                      0.162    33.05     —0.44   10.77    43.38     65.34   —21.96 QP
            No — C to co —4 C Cn B C) ho +




                                                      0.234    27.58     —0.40   10.17§   37.93     62.30   —24.31 QP
                                                      0.393    27.40     —0.37   10.72    37.15     57.99   —20. 24 QP
                                                      0.393    19.32     —0.37   10.72    29.67     41.99   —18. 32 Average
                                                      0.608    16.02     —0.38   10.77    26.41     46.00   —19. 59 Average
                                                      0.686    24.17     —0.38   10.77    34.56     56.00   —21.44 QP
                                                      0. 759   14.40     —0.38   10.80    24.82     46.00   —21.18 Average
                                                      1.000    11.02     —0.38   10.87    21.51     46.00   —24.49 Average
                                                      1.043    22.32     —0.38   10.88    32.82     56.00   —23.18 QP
                                                      1.619    10.18     —0.40   10.93    20.71     46.00   —25.29 Average
                                                      2.721    14.16     —0.43   10.93    24.66     46.00   —21. 34 Average
                                                      2.809    19.94     —0.44   10.93    30.43     56.00   —25.57 QP


Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                                     Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                    Page 21 of 24


CCIS                                                                           Report No: CCISE190704306V01


Product name:             POS Terminal                             Product model:          IM30
Test by:                  Mike                                    Test mode:               NFC Tx mode

Test frequency:           150 kHz ~ 30 MHz                         Phase:                  Neutral

Test voltage:             AC 120 V/60 Hz                           Environment:           Temp: 22.5°C         Huni: 55%


             80Level (dBuV)


             70
             so                                                                                      FCC PART15 B OP

             50\\\                                                                                   FCC PART15 B AV

            40

             30

             20

             10



        Trace: 25                                         Freguency (Mifé)
                                   Read   LISN          Cable                Limnit        Over
                         Freq     Level Factor           Loss      Level      Line        Limit Remark

                    """MHz dBu¥y _ db _db dBu¥ dBu¥ —db
             1          0.461      29.52     —0.6§5     10.74      39.61     56.67       —17.06   QP
             2          0.461      23.11     —0.6§5     10.74      33.20     46.67       —13.47   Average
             3          0.608      31.77     —0.64      10.77      41.90     56.00       —14.10   QP
             4          0.647T     31.26     —0.64      10.77      41.39     56.00       —14.61   QP
             5          0.647      23.42     —0.64      10.77      33.55     46.00       —12.45   Average
             6          0.727      30.18     —0.64      10.78      40.32     56.00       —15.68   QP
             1          0.783      21.71     —0.64      10.81      31.88     46.00       —14.12   Average
             8          0.871      19.34     —0.63      10.83      29.54     46.00       —16.46   Average
             9          1.049      29.83     —0.63      10.88      40.08     56.00       —15.92   QP
            10          1.645      26.73     —0.66      10.93      37.00     56.00       —19.00   qP
            11          1.645      19.27     —0.66      10.93      29.54     46.00       —16.46   Average
            12          2.824      17.27     —0.67      10.93      27.53     46.00       —18.47   Average


Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen ZhongjianNantang Testing Co., Ltd.                                                  Project No.: CCISE1907043
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 22 of 24


                                                                        Report No: CCISE190704306V01

7      Test Setup Photos
                                                  Radiated Emission
                                                     9kHz-30MHz




                                                    30MHz-1000MHz




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                    Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                  Page 23 of 24


                                                                           Report No: CCISE190704306V01


                                                 Conducted Emission




 8       EUT Constructional Photos
 Reference to the test report No. CCISE190704301



                                               ------End of report------




Shenzhen ZhongjianNanfang Testing Co., Ltd.                                       Project No.: CCISE1907043
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                     Page 24 of 24