Test report DFS

FCC ID: V5PIM304GBW

Test Report

Download: PDF
FCCID_4434954

                            Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190704605

1       Cover Page
                                DFS TEST REPORT
 Applicant:                                 PAX Technology Limited
                                            Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road,
 Address of Applicant:
                                            Wanchai, Hong Kong
 Equipment Under Test (EUT)

    Product Name:                           POS Terminal

    Model No.:                              IM30

 Applicable standards:                      PAX

 FCC ID:                                    V5PIM304GBW

 Applicable standards:                      FCC CFR Title 47 Part 15 Subpart E Section 15.407

 Date of sample receipt:                    11 Jul., 2019

 Date of Test:                              11 Jul., to 19 Aug., 2019

 Date of report issued:                     20 Aug., 2019

 Test Result:                               PASS*
 *In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190704605

2      Version
       Version No.                            Date                                 Description
             00                         20 Aug., 2019                                Original




    Tested by:                                                           Date:          20 Aug., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          20 Aug., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 2 of 20


                                                                                                                     Report No: CCISE190704605

3 Contents
                                                                                                                                                                         Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1       CLIENT INFORMATION ........................................................................................................................................... 5
    5.2       GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................... 5
    5.3       TEST ENVIRONMENT AND TEST MODE .................................................................................................................. 5
    5.4       DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 5
    5.5       RELATED SUBMITTAL(S) / GRANT (S) .................................................................................................................. 5
    5.6       LABORATORY FACILITY ........................................................................................................................................ 6
    5.7       LABORATORY LOCATION ...................................................................................................................................... 6
    5.8       TEST INSTRUMENTS LIST....................................................................................................................................... 6
6     DFS TECHNICAL REQUIREMENTS .................................................................................................................. 7
    6.1       DFS PARAMETERS ............................................................................................................................................... 7
    6.2       DFS TECHNICAL REQUIREMENTS ........................................................................................................................ 9
    6.3       DFS THRESHOLD LEVEL ...................................................................................................................................... 9
    6.4       TEST SETUP BLOCK.............................................................................................................................................. 9
    6.5       EUT CONFIGURATION FOR DFS TEST ............................................................................................................... 10
7     TEST RESULT .................................................................................................................................................... 11
    7.1       VERIFICATION OF RADAR TYPE AND LEVEL ....................................................................................................... 11
    7.2       CHANNEL MOVE TIME AND CHANNEL CLOSING TRANSMISSION TIME .............................................................. 18
    7.3       NON-OCCUPANCY PERIOD ................................................................................................................................. 19
8     TEST SETUP PHOTO ........................................................................................................................................ 20
9     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 20




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                           Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                   Page 3 of 20


CCGIS                                                                          Report No: CCISE190704605

4 Test Summary
                  Test Items                                       Limit                     Result

         Channel Availability Check                            > 60 seconds                   N/A
                                                        > 100% of the UNII 99%
          UNII Detection Bandwidth                                                            N/A
                                                     transmission power bandwidth

                                                        Radar type 1,2,3.4 2 60%
                                                     Aggregate Radar type 1~4 and
       Statistical Performance Check                                                          N/A
                                                                  5280%
                                                           Radar type 6 270%
             Channel Move Time                                 < 10 seconds                   Pass
                                                   <20ms + aggregate of 60ms over
    Channel Closing Transmission Time                                                         Pass
                                                       remaining 10 second period
           Non—Occupancy Period                                > 30 minutes                   Pass
 Note: "Pass" means meet the requirements, "N/A" means not applicable




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1907046
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 4 of 20


c c I s                                                                          Report No: CCISE190704605

5 General Information
5.1 Client Information
        Applicant:                        PAX Technology Limited
        Address:                          Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road, Wanchai,
                                          Hong Kong
        Manufacturer:                     PAX Computer Technology(Shenzhen) Co. Ltd.
        Address:                          401—402 No.3 Building, Software Park, Nanshan district, Shenzhen,
                                          Guangdong, P.R.C.

5.2 General Description of E.U.T.
       Product Name:                       POS Terminal
       Model No.:                          IM30
       Transmitter frequency range:       5150MHz~5250MHz, 5250MHz~5350MHz
                                          5470MHz~5725MHz, 5725MHz~5825MHz
       Modulation type:                   OFDM
       WLAN Function:                     802.11a/802.11n/802.11ac
       Bandwidth:                         20MHz/A0MHz/80MHz
       Antenna Type:                       Internal Antenna
       Antenna Gain:                       1.0 dBi
       DFS Operation Type:                [—] Master Device
                                          [_] Slaver Device with Radar detection function
                                          [X] Slaver Device without Radar detection function
       Power supply:                       DC 12V—48V
       Test Sample Condition:             The test samples were provided in good working order with no visible
                                          defects.

5.3 Test Environment and test mode
       Data Load mode:                    Keep the EUT in normal transmitting mode by WiFi
       Temperature:                       20 ~ 25 °C
       Humidity:                          60% ~65%
       Atmospheric pressure:              1012 kPa

5.4 Description of Support Units
         Manufacturer                     Description                       Model              Serial Number
           LENOVO                            Laptop                         SL510                 2847A65
           WAVLINK                        WiFi Router                    WL—WNS75A2            WL1512260097

5.5 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1907046
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 5 of 20


c c I s                                                                           Report No: CCISE190704605

5.6 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ® FCC — Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The test firm Registration No. is 727551.
        @ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
        ©® CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/EC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        ® A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: htips:/portal. a2la.org/scopepdt/4346—01 .pdf

5.7 Laboratory Location
     Shenzhen Zhongjian Nanfang Testing Co., Ltd.
     Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
     Bac‘an District, Shenzhen, Guangdong, China
     Tel: +86—755—23118282, Fax: +86—755—23116366
     Email: info@ccis—cb.com, Website: http//www.ccis—cb.com

5.8 Test Instruments list
    Test Equipment            Manufacturer         Model No.         Serial No.      (i:'l_r?_:z;;;e   i:}::z_t;e

   Spectrum Analyzer             Agilent            N9020A          MY50510123        11—10—2018        11—09—2019
 Vector Signal Generator         Agilent            NS182A          MY49060014        11—10—2018        11—09—2019
      RFE Switch Unit           Ascentest         AT890—REB             =                  =                —
    DFS Test Software          MWRETEST            MTS 8310                        Version: 2.0.0.0
  N76078 Signal Studio         KEYSIGHT               —                            Version: 2.0.0.1




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1907046
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 6 of 20


c c I s                                                                         Report No: CCISE190704605

6 DFS Technical Requirements
6.1 DFS Parameters
                  Table D.1: Applicability of DFS Requirements Prior to Use of a Channel
                                                                Operational Mode
                 Requirement                   Master   Client Without Radar      Client With Radar
                                                              Detection               Detection
             Non—Occupancy period               Yes          Not required                Yes
            DFS Detection Threshold             Yes          Not required                Yes
        Channel Availability Check Time         Yes          Not required            Not required
           U—NII Detection Bandwidth            Yes          Not required                Yes

                  Table D.2: Applicability of DFS requirements during normal operation
                                                               Operational Mode
                Requirement
                                                    Master           Client Without Radar Detection
           DFS Detection Threshold                    Yes                      Not required
      Channel Closing Transmission Time               Yes                          Yes
             Channel Move Time                        Yes                          Yes
           U—NII Detection Bandwidth                          Yes                      Not required


                                                                      Operational Mode
     Additional requirements for devices
         —       &         &                       Master Device or Client with    Client Without Radar
       with multiple bandwidth modes                    Radar Detection                  Detection
         U—NII Detection Bandwidth and                                                              :
         Statistical Performance Check             All BW modes must be tested             Not required
       Channel Move Time and Channel                Test using widest BW mode       Test using the widest BW
           Closing Transmission Time                          available             mode available for the link
                  All other tests                       Any single BW mode                Not required
    Note: Frequencies selected for statistical performance check (Section 7.8.4) should include several
    frequencies within the radar detection bandwidth and frequencies near the edge of the radar detection
    bandwidth. For 802.11 devices it is suggested to select frequencies in each of the bonded 20 MHz
    channels and the channel center frequency.

                                        Table D.3: DFS Detection Thresholds
                            Maximum Transmit Power                               Value (See Notes 1,2, and 3)
                             EIRP = 200 mW                                                 —64 dBm
          EIRP < 200 mW and power spectral density < 10 dBm/MHz                            —62 dBm
          EIRP < 200 mW that do not meet the power spectral density
                                        .                                                  —64 dBm
                                    requirement
    Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
    Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the
    test transmission waveforms to account for variations in measurement equipment. This will ensure that
    the test signal is at or above the detection threshold level to trigger a DFS response.
    Note 3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication
    662911 DQ1.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1907046
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                 Page 7 of 20


                                                                                 Report No: CCISE190704605

                                       Table D.4: DFS requirement values
                          Parameter                                           Value
                     Non-occupancy period                              Minimum 30 minutes
                Channel Availability Check Time                            60 seconds
                      Channel Move Time                              10 seconds (See Note 1)
                                                           200 ms + an aggregate of 60ms over remaining
               Channel Closing Transmission Time
                                                               10 second period (See Notes 1 and 2)
                                                            Minimum 100% of the UNII 99% transmission
                   U-NII Detection Bandwidth
                                                                   power bandwidth (See Note 3)
    Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed with Radar Type
            0. The measurement timing begins at the end of the Radar Type 0 burst.
    Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of the
            Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move
            (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration
            of control signals will not count quiet periods in between transmissions.
    Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For each frequency
            step, the minimum percentage of detection is 90 percent. Measurements are performed with no data
            traffic.

                                Table D.5: Short Pulse Radar Test Waveforms
                                                                           Minimum                      Minimum
                       Pulse Width       PRI                             Percentage of
      Radar Type         (μsec)         (μsec)      Number of Pulses      Successful                    Number of
                                                                                                          Trials
                                                                           Detection
           0                1           1428               18             See Note 1                   See Note 1


                                            Test A
           1                 1                                                         60%                  30
                                            Test B


           2                 1-5     150-230             23-29                60%                30
           3                6-10     200-500             16-18                60%                30
           4               11-20     200-500             12-16                60%                30
                                        Aggregate (Radar Types 1-4)           80%               120
    Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move time,
    and channel closing time tests.

                                 Table D.6: Long Pulse Radar Test Waveform
                                                                           Minimum
        Radar        Pulse   Chirp      PRI     Number of    Number     Percentage of                   Minimum
                     Width   Width              Pulses per                                              Number of
        Type         (μsec) (MHz)     (μsec)      Burst     of Bursts     Successful                      Trials
                                                                          Detection
                                      1000-
          5         50-100   5-20                  1-3        8-20          80%                             30
                                       2000
                       Long Pulse Radar Test Signal Wave form 12 second transmission




                              Table D.7: Frequency Hopping Radar Test Waveform
                                                             Hopping       Minimum
                    Pulse                         Hopping                                               Minimum
        Radar       Width      PRI      Pulses      Rate    Sequence     Percentage  of                 Number of
        Type                  (μsec) per Hop                 Length       Successful
                    (μsec)                         (kHz)     (msec)        Detection                      Trials
          6            1       333        0        0.333       300           70%                            30



Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 8 of 20


                                                                              Report No: CCISE190704605

6.2 DFS Technical Requirements
                                                                    DFS Operational mode
               Requirement                                           Slave without       Slave with Radar
                                                   Master
                                                                   Radar Detection         Detection
       Channel Availability Check                   √               Not Required          Not Required
        UNII Detection Bandwidth                    √               Not Required               √
      Statistical Performance Check                 √               Not Required               √
           Channel Move Time                        √                     √                    √
      Channel Closing Transmission
                                                    √                    √                       √
                    Time
         Non-Occupancy Period                       √                    √                       √

6.3 DFS Threshold Level
                                            DFS Threshold Level
           5250MHz ~ 5350MHz                                -62 dBm @ antenna connector
           5470MHz ~ 5725MHz                                -62 dBm @ antenna connector
   Note: The worst case level was selected to perform the test.

6.4 Test Setup Block
       For master device




       For Slaver without radar detection function device




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 9 of 20


                                                                            Report No: CCISE190704605


       For Slaver with radar detection function device




6.5 EUT Configuration for DFS Test
                     Test Items                                          Channel Frequency
                Channel Move Time                                        5290MHz, 5530MHz
          Channel Closing Transmission Time                              5290MHz, 5530MHz
               Non-Occupancy Period                                      5290MHz, 5530MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                        Page 10 of 20


                                                                         Report No: CCISE190704605

7 Test Result
7.1 Verification of Radar Type and Level
                                                    80MHz/5290MHz




                                                      Radar Type 0




                                                      Radar Type 1




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 11 of 20


                                                                         Report No: CCISE190704605




                                                      Radar Type 2




                                                      Radar Type 3




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 12 of 20


                                                                         Report No: CCISE190704605




                                                      Radar Type 4




                                                      Radar Type 5




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 13 of 20


                                                                         Report No: CCISE190704605




                                                     Radar Type 6
                                                   80MHz@5530MHz




                                                      Radar Type 0




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 14 of 20


                                                                         Report No: CCISE190704605




                                                      Radar Type 1




                                                      Radar Type 2




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 15 of 20


                                                                         Report No: CCISE190704605




                                                      Radar Type 3




                                                      Radar Type 4




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 16 of 20


                                                                         Report No: CCISE190704605




                                                      Radar Type 5




                                                      Radar Type 6




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 17 of 20


                                                                         Report No: CCISE190704605

7.2 Channel Move Time and Channel Closing Transmission Time
                                                    80MHz/5290MHz




               Test Items                                       Value               Limit
    Channel Closing Transmission Time                           14 ms              260 ms
          Channel Move Time                                    323 ms               10 s

                                                    80MHz/5530MHz




               Test Items                                       Value               Limit
    Channel Closing Transmission Time                           55 ms              260 ms
          Channel Move Time                                    318 ms               10 s




                                                                                  Test Result: Pass


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 18 of 20


                                                                         Report No: CCISE190704605

7.3 Non-Occupancy Period
                                                    80MHz/5290MHz




                 Test Items                                    Value                Limit
            Non-Occupancy Period                               1820 s         30 minutes (1800 s)

                                                    80MHz/5530MHz




                 Test Items                                    Value                Limit
            Non-Occupancy Period                               1820 s         30 minutes (1800 s)

                                                                                   Test Result: Pass


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1907046
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 19 of 20



Document Created: 2019-08-27 14:17:10
Document Modified: 2019-08-27 14:17:10

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC