Modular test report

FCC ID: V5PIM304GBW

Test Report

Download: PDF
FCCID_4434920

            FCC RF Test Report                                                Report No. : FG8O1914-01A




                            FCC RF Test Report
           APPLICANT                      :   Fibocom Wireless Inc
           EQUIPMENT                      :   LTE module
           BRAND NAME                     :   Fibocom
           MODEL NAME                     :   NL668-AM-00
           FCC ID                         :   ZMONL668AM00
           STANDARD                       :   FCC 47 CFR Part 2, 22(H), 24(E), 27(L)
           CLASSIFICATION                 :   PCS Licensed Transmitter (PCB)

      The product was received on Oct. 19, 2018 and completely tested on Dec. 12, 2018. We,
      Sporton International (Shenzhen) Inc., would like to declare that the tested sample has been
      evaluated in accordance with the procedures given in ANSI C63.26-2015 and shown
      compliance with the applicable technical standards.
      The test results in this report apply exclusively to the tested model / sample. Without written
      approval of Sporton International (Shenzhen) Inc., the test report shall not be reproduced
      except in full.




            Approved by: Eric Shih / Manager


                              Sporton International (Shenzhen) Inc.
        1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen City,
                                        Guangdong Province 518055, China




Sporton International (Shenzhen) Inc.                                      Page Number        : 1 of 14
TEL : 86-755-8637-9589                                                     Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                     Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                             Report Template No.: BU5-FG22/24/27 Version 2.0


               FCC RF Test Report                                                                                       Report No. : FG8O1914-01A



                                                     TABLE OF CONTENTS
REVISION HISTORY.......................................................................................................................................... 3
SUMMARY OF TEST RESULT ......................................................................................................................... 4
1    GENERAL DESCRIPTION .......................................................................................................................... 5
      1.1      Applicant ............................................................................................................................................ 5
      1.2      Manufacturer ..................................................................................................................................... 5
      1.3      Product Feature of Equipment Under Test ....................................................................................... 5
      1.4      Product Specification of Equipment Under Test ............................................................................... 6
      1.5      Modification of EUT ........................................................................................................................... 6
      1.6      Maximum ERP/EIRP Power, Frequency Tolerance, and Emission Designator ............................... 6
      1.7      Testing Location ................................................................................................................................ 7
      1.8      Applicable Standards ........................................................................................................................ 7
2    TEST CONFIGURATION OF EQUIPMENT UNDER TEST ........................................................................ 8
      2.1      Test Mode.......................................................................................................................................... 8
      2.2      Connection Diagram of Test System ................................................................................................ 9
      2.3      Support Unit used in test configuration ............................................................................................. 9
      2.4      Frequency List of Low/Middle/High Channels ................................................................................... 9
3    CONDUCTED TEST RESULT................................................................................................................... 10
      3.1      Measuring Instruments .................................................................................................................... 10
      3.2      Test Setup ....................................................................................................................................... 10
      3.3      Conducted Output Power and ERP/EIRP ....................................................................................... 10
4    RADIATED TEST ITEMS .......................................................................................................................... 11
      4.1      Measuring Instruments .................................................................................................................... 11
      4.2      Test Setup ....................................................................................................................................... 11
      4.3      Test Result of Radiated Test ........................................................................................................... 11
      4.4      Field Strength of Spurious Radiation Measurement ....................................................................... 12
5    LIST OF MEASURING EQUIPMENT ........................................................................................................ 13
6    UNCERTAINTY OF EVALUATION ........................................................................................................... 14
APPENDIX A. TEST RESULTS OF CONDUCTED TEST
APPENDIX B. TEST RESULTS OF RADIATED TEST
APPENDIX C. TEST SETUP PHOTOGRAPHS
APPENDIX D. PRODUCT EQUALITY DECLARATION




Sporton International (Shenzhen) Inc.                                                                           Page Number        : 2 of 14
TEL : 86-755-8637-9589                                                                                          Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                                                          Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                                                  Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                        Report No. : FG8O1914-01A




                                           REVISION HISTORY

   REPORT NO.           VERSION                             DESCRIPTION                             ISSUED DATE

  FG8O1914-01A           Rev. 01        Initial issue of report                                      Dec. 19, 2018




Sporton International (Shenzhen) Inc.                                              Page Number        : 3 of 14
TEL : 86-755-8637-9589                                                             Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                             Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                     Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                          Report No. : FG8O1914-01A




                                 SUMMARY OF TEST RESULT

          Report
                         FCC Rule          Description                 Limit            Result      Remark
          Section

                                        Conducted Output
                          §2.1046                                  Reporting Only        PASS           -
                                            Power
                                        Effective Radiated
                       §22.913(a)(5)                                 < 7 Watts           PASS           -
                                              Power
             3.3
                                        Equivalent Isotropic
                        §24.232(c)                                   < 2 Watts           PASS           -
                                         Radiated Power
                                        Equivalent Isotropic
                       §27.50(d)(4)                                  < 1 Watts           PASS           -
                                         Radiated Power
                          §2.1053                                                                 Under limit
                        §22.917(a)       Field Strength of                                        35.70 dB at
             4.4                                               < 43+10log10(P[Watts])    PASS
                        §24.238(a)      Spurious Radiation                                         3465.200
                         §27.53(h)                                                                   MHz




Sporton International (Shenzhen) Inc.                                               Page Number        : 4 of 14
TEL : 86-755-8637-9589                                                              Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                              Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                      Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                  Report No. : FG8O1914-01A


1      General Description
1.1 Applicant
       Fibocom Wireless Inc
       5/F,Tower A,Technology Building II,1057 Nanhai Avenue,Shenzhen,China


1.2 Manufacturer
       Fibocom Wireless Inc
       5/F,Tower A,Technology Building II,1057 Nanhai Avenue,Shenzhen,China


1.3 Product Feature of Equipment Under Test
                                                  Product Feature
       Equipment                                 LTE module
       Brand Name                                Fibocom
       Model Name                                NL668-AM-00
       FCC ID                                    ZMONL668AM00
                                                 WCDMA/HSPA/DC-HSDPA/HSPA+(16QAM uplink is not
       EUT supports Radios application
                                                 supported)/LTE
       IMEI Code                                 Radiation: 866857032754380
       HW Version                                V1.0.1
       SW Version                                19006.1000.00.02.77.07
       EUT Stage                                 Production Unit
       Remark:
       1. The above EUT's information was declared by manufacturer. Please refer to the specifications or
           user's manual for more detailed description.
       2. The report is in accordance with C2PC and the product equality declaration as Appendix D. Based
           on the similarity between current and previous project, the test cases of Power/ERP/EIRP/RSE
           from original test report (Sporton Report Number FG8O1914A) were verified for the differences.




Sporton International (Shenzhen) Inc.                                        Page Number        : 5 of 14
TEL : 86-755-8637-9589                                                       Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                       Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                               Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                    Report No. : FG8O1914-01A


1.4 Product Specification of Equipment Under Test
                                        Standards-related Product Specification
                                                    WCDMA:
                                                    Band V: 826.4 MHz ~ 846.6 MHz
       Tx Frequency
                                                    Band II:   1852.4 MHz ~ 1907.6 MHz
                                                    Band IV: 1712.4 MHz ~ 1752.6 MHz
                                                    WCDMA:
                                                    Band V: 871.4 MHz ~ 891.6 MHz
       Rx Frequency
                                                    Band II:   1932.4 MHz ~ 1987.6 MHz
                                                    Band IV: 2112.4 MHz ~ 2152.6 MHz
                                                    WCDMA:
                                                    Band V: 23.53 dBm
       Maximum Output Power to Antenna
                                                    Band II:   24.17 dBm
                                                    Band IV: 23.74 dBm
       Antenna Type                                Dipole Antenna
                                                   Cellular Band: 4.00 dBi
       Antenna Gain                                PCS Band: 4.00 dBi
                                                   AWS Band: 4.50 dBi
                                                   WCDMA : BPSK (Uplink)
                                                   HSDPA/DC-HSDPA : QPSK (Uplink)
       Type of Modulation                          HSUPA : QPSK (Uplink)
                                                   HSPA+ : 16QAM (uplink is not supported)
                                                   DC-HSDPA : 64QAM


1.5 Modification of EUT
       No modifications are made to the EUT during all test items.



1.6 Maximum ERP/EIRP Power, Frequency Tolerance, and Emission
    Designator
                                                                                                   Maximum
     FCC Rule                             System                       Type of Modulation          ERP/EIRP
                                                                                                       (W)
      Part 22H                WCDMA Band V RMC 12.2Kbps                       BPSK                   0.3451
      Part 24E                WCDMA Band II RMC 12.2Kbps                      BPSK                   0.6561
      Part 27L                WCDMA Band IV RMC 12.2Kbps                      BPSK                   0.6668




Sporton International (Shenzhen) Inc.                                         Page Number        : 6 of 14
TEL : 86-755-8637-9589                                                        Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                        Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                      Report No. : FG8O1914-01A


1.7 Testing Location
      Sporton International (Shenzhen) Inc. is accredited to ISO 17025 by National Voluntary Laboratory
      Accreditation Program (NVLAP code: 600156-0).

        Test Site               Sporton International (Shenzhen) Inc.

                                No. 3 Bldg the third floor of south, Shahe River west, Fengzeyuan Warehouse, Nanshan
        Test Site Location District, Shenzhen City, Guangdong Province 518055, China
                                TEL: +86-755- 3320-2398
                                  Sporton Site No.        FCC designation No.          FCC Test Firm Registration No.
        Test Site No.
                                        03CH02-SZ               CN5019                                577730



1.8 Applicable Standards
       According to the specifications of the manufacturer, the EUT must comply with the requirements of the
       following standards:
             47 CFR Part 2, 22(H), 24(E), 27(L)
             ANSI C63.26-2015
             FCC KDB 971168 D01 Power Meas. License Digital Systems v03r01
             FCC KDB 412172 D01 Determining ERP and EIRP v01r01


       Remark: All test items were verified and recorded according to the standards and without any deviation
       during the test.




Sporton International (Shenzhen) Inc.                                            Page Number        : 7 of 14
TEL : 86-755-8637-9589                                                           Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                           Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                   Report Template No.: BU5-FG22/24/27 Version 2.0


             FCC RF Test Report                                                Report No. : FG8O1914-01A


2      Test Configuration of Equipment Under Test
2.1 Test Mode
       Antenna port conducted and radiated test items were performed according to KDB 971168 D01 Power
       Meas. License Digital Systems v03r01 with maximum output power.
       Radiated measurements were performed with rotating EUT in different three orthogonal test planes to
       find the maximum emission.
       Radiated emissions were investigated as following frequency range:
       1.    30 MHz to 10th harmonic for WCDMA Band V.
       2.    30 MHz to 10th harmonic for WCDMA Band IV.
       3.    30 MHz to 10th harmonic for WCDMA Band II.
       All modes and data rates and positions were investigated.
       Test modes are chosen to be reported as the worst case configuration below:
                                                   Test Modes
                Band                         Radiated TCs                            Conducted TCs
            WCDMA Band V           RMC 12.2Kbps Link                        RMC 12.2Kbps Link
            WCDMA Band II          RMC 12.2Kbps Link                        RMC 12.2Kbps Link
            WCDMA Band IV          RMC 12.2Kbps Link                        RMC 12.2Kbps Link




Sporton International (Shenzhen) Inc.                                       Page Number        : 8 of 14
TEL : 86-755-8637-9589                                                      Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                      Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                              Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                                     Report No. : FG8O1914-01A


2.2 Connection Diagram of Test System


                  System                                                                                     BT
                                      AP router              Notebook            GPS Station
                 Simulator                                                                                Earphone



                  Power
                                                               EUT                                        Notebook
                  Source




                  Cradle                Earphone               iPod                WLAN AP                 Monitor




                                  This example is connection diagram of EUT test configurations.

                   . For detail, please refer to test mode configuration and setup photographs for each test item.




2.3 Support Unit used in test configuration
       Item Equipment                Trade Name Model No.                        FCC ID      Data Cable              Power Cord
       1.     System Simulator R&S                      CMU 200                  N/A         N/A                     Unshielded, 1.8m
       2.     USB cable              N/A                N/A                      N/A         Unshielded,1.2m N/A
       3.     Adapter                N/A                N/A                      N/A         N/A                     N/A
       4.     Test Jig               N/A                N/A                      N/A         N/A                     N/A
       5.     WWAN Antenna           N/A                HYT-690-2700H-3 N/A                  N/A                     N/A



2.4 Frequency List of Low/Middle/High Channels
                                                        Frequency List
      Band             Channel/Frequency(MHz)                         Lowest                  Middle                  Highest
     WCDMA                         Channel                             4132                    4182                     4233
     Band V                      Frequency                            826.4                    836.4                   846.6
     WCDMA                         Channel                             9262                    9400                     9538
     Band II                     Frequency                            1852.4                  1880.0                   1907.6
     WCDMA                         Channel                             1312                    1413                     1513
     Band IV                     Frequency                            1712.4                  1732.6                   1752.6




Sporton International (Shenzhen) Inc.                                                        Page Number        : 9 of 14
TEL : 86-755-8637-9589                                                                       Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                                       Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                               Report Template No.: BU5-FG22/24/27 Version 2.0


               FCC RF Test Report                                                 Report No. : FG8O1914-01A


3       Conducted Test Result
3.1       Measuring Instruments
          See list of measuring instruments of this test report.

3.2       Test Setup
3.2.1     Conducted Output Power




3.3 Conducted Output Power and ERP/EIRP
3.3.1     Description of the Conducted Output Power and ERP/EIRP
         A system simulator was used to establish communication with the EUT. Its parameters were set to
         enforce EUT transmitting at the maximum power. The measured power in the radio frequency on the
         transmitter output terminals shall be reported.
         The ERP of mobile transmitters must not exceed 7 Watts for WCDMA Band V.
         The EIRP of mobile transmitters must not exceed 2 Watts for WCDMA Band II.
         The EIRP of mobile transmitters must not exceed 1 Watts for WCDMA Band IV.
         According to KDB 412172 D01 Power Approach,
         EIRP = PT + GT – LC, ERP = EIRP -2.15, where
         PT = transmitter output power in dBm
         GT = gain of the transmitting antenna in dBi
         LC = signal attenuation in the connecting cable between the transmitter and antenna in dB



3.3.2     Test Procedures
          1.     The testing follows ANSI C63.26 Section 5.2
          2.     The transmitter output port was connected to the system simulator.
          3.     Set EUT at maximum power through the system simulator.
          4.     Select lowest, middle, and highest channels for each band and different modulation.
          5.     Measure and record the power level from the system simulator.




Sporton International (Shenzhen) Inc.                                          Page Number        : 10 of 14
TEL : 86-755-8637-9589                                                         Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                         Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                 Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                 Report No. : FG8O1914-01A


4         Radiated Test Items
4.1       Measuring Instruments
          See list of measuring instruments of this test report.



4.2       Test Setup
4.2.1     For radiated test from 30MHz to 1GHz




4.2.2     For radiated test above 1GHz




4.3       Test Result of Radiated Test
          Please refer to Appendix B.




Sporton International (Shenzhen) Inc.                                       Page Number        : 11 of 14
TEL : 86-755-8637-9589                                                      Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                      Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                              Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                    Report No. : FG8O1914-01A


4.4 Field Strength of Spurious Radiation Measurement
4.4.1     Description of Field Strength of Spurious Radiated Measurement
         The power of any emission outside of the authorized operating frequency ranges must be attenuated
         below the transmitter power (P) by a factor of at least 43 + 10 log (P) dB. The spectrum is scanned
         from 30 MHz up to a frequency including its 10th harmonic.



4.4.2     Test Procedures
            1. The testing follows ANSI C63.26 Section 5.5
            2. The EUT was placed on a rotatable wooden table 0.8 meters for frequency below 1GHz and
                1.5 meter for frequency above 1GHz above the ground.
            3. The EUT was set 3 meters from the receiving antenna, which was mounted on the antenna
                tower.
            4. The table was rotated 360 degrees to determine the position of the highest spurious emission.
            5. The height of the receiving antenna is varied between one meter and four meters to search for
                the maximum spurious emission for both horizontal and vertical polarizations.
            6. Make the measurement with the spectrum analyzer's RBW = 1MHz, VBW = 3MHz, taking
                record of maximum spurious emission.
            7. A horn antenna was substituted in place of the EUT and was driven by a signal generator.
            8. Tune the output power of signal generator to the same emission level with EUT maximum
                spurious emission.
            9. Taking the record of output power at antenna port.
            10. Repeat step 7 to step 8 for another polarization.
            11. EIRP (dBm) = S.G. Power – Tx Cable Loss + Tx Antenna Gain
            12. ERP (dBm) = EIRP - 2.15
            13. The RF fundamental frequency should be excluded against the limit line in the operating
                frequency band.
            14. The limit line is derived from 43 + 10log(P) dB below the transmitter power P(Watts)




Sporton International (Shenzhen) Inc.                                          Page Number        : 12 of 14
TEL : 86-755-8637-9589                                                         Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                         Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                 Report Template No.: BU5-FG22/24/27 Version 2.0


                 FCC RF Test Report                                                              Report No. : FG8O1914-01A


    5        List of Measuring Equipment
                                                                              Calibration
Instrument      Manufacturer Model No. Serial No.           Characteristics                    Test Date       Due Date        Remark
                                                                                 Date
  Spectrum                                                                                                                      Radiation
                    R&S             FSV40       101041       10Hz~40GHz       Oct. 20, 2018 Dec. 12, 2018     Oct. 19, 2019
  Analyzer                                                                                                                    (03CH02-SZ)
                                                                                                                                Radiation
Bilog Antenna      TeseQ           CBL6112D      35407       30MHz-2GHz       May 10, 2018 Dec. 12, 2018      May 09, 2019
                                                                                                                              (03CH02-SZ)
Double Ridge                        BBHA                                                                                        Radiation
             SCHWARZBECK                      9120D-1285     1GHz~18GHz       Dec. 13, 2017 Dec. 12, 2018     Dec. 12, 2018
Horn Antenna                        9120D                                                                                     (03CH02-SZ)
                               TTA1840-35                                                                                       Radiation
 HF Amplifier      MITEQ                       1871923       18GHz~40GHz      Jul. 30, 2018   Dec. 12, 2018   Jul. 29, 2019
                                  -HG                                                                                         (03CH02-SZ)
                                                                                                                                Radiation
SHF-EHF Horn     com-power          AH-840      101071       18Ghz-40GHz      Mar. 30, 2018 Dec. 12, 2018     Mar. 29, 2019
                                                                                                                              (03CH02-SZ)
                                                                                                                                Radiation
 LF Amplifier     Burgeon          BPA-530      102211       0.01~3000Mhz     Oct. 20, 2018 Dec. 12, 2018     Oct. 19, 2019
                                                                                                                              (03CH02-SZ)
                                                                                                                                Radiation
 HF Amplifier      Agilent          8449B     3008A01023    1GHz~26.5GHz      Oct. 20, 2018 Dec. 12, 2018     Oct. 19, 2019
                                                                                                                              (03CH02-SZ)
  AC Power                                    61601000247                                                                       Radiation
                  Chroma            61601                        N/A              NCR         Dec. 12, 2018       NCR
   Source                                          0                                                                          (03CH02-SZ)
                                                                                                                                Radiation
 Turn Table       Chaintek          T-200         N/A        0~360 degree         NCR         Dec. 12, 2018       NCR
                                                                                                                              (03CH02-SZ)
                                                                                                                                Radiation
Antenna Mast      Chaintek         MBS-400        N/A          1 m~4 m            NCR         Dec. 12, 2018       NCR
                                                                                                                              (03CH02-SZ)
    NCR: No Calibration Required




    Sporton International (Shenzhen) Inc.                                                   Page Number        : 13 of 14
    TEL : 86-755-8637-9589                                                                  Report Issued Date : Dec. 19, 2018
    FAX : 86-755-8637-9595                                                                  Report Version     : Rev. 01
    FCC ID : ZMONL668AM00                                                          Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                           Report No. : FG8O1914-01A


6      Uncertainty of Evaluation
       Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)
             Measuring Uncertainty for a Level of
                                                                          2.5dB
               Confidence of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (1 GHz ~ 18 GHz)
              Measuring Uncertainty for a Level of
                                                                          3.3dB
                Confidence of 95% (U = 2Uc(y))


       Uncertainty of Radiated Emission Measurement (18 GHz ~ 40 GHz)
              Measuring Uncertainty for a Level of
                                                                          3.7dB
                Confidence of 95% (U = 2Uc(y))




Sporton International (Shenzhen) Inc.                                 Page Number        : 14 of 14
TEL : 86-755-8637-9589                                                Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                        Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                      Report No. : FG8O1914-01A




Appendix A. Test Results of Conducted Test

      Conducted Output Power(Average power)
                                         Conducted Power (*Unit: dBm)
                     Band                 WCDMA Band V       WCDMA Band II     WCDMA Band IV
                   Channel              4132 4182 4233 9262 9400 9538 1312 1413 1513
                  Frequency             826.4 836.4 846.6 1852.4 1880 1907.6 1712.4 1732.6 1752.6
                  RMC 12.2K             23.42   23.53   23.45   24.17     24.02    23.78    23.74    23.63     23.65
              HSDPA Subtest-1           22.58   22.52   22.49   22.87     22.76    22.89    22.38    22.44     22.41
              HSDPA Subtest-2           22.62   22.60   22.54   22.88     22.82    22.85    22.39    22.40     22.35
              HSDPA Subtest-3           22.12   22.12   22.04   22.40     22.35    22.47    21.92    21.93     21.88
              HSDPA Subtest-4           22.13   22.12   22.05   22.38     22.34    22.45    21.91    21.92     21.88
           DC-HSDPA Subtest-1           22.31   22.24   22.23   22.63     22.52    22.65    22.12    22.18     22.16
           DC-HSDPA Subtest-2           22.36   22.33   22.29   22.64     22.57    22.60    22.12    22.12     22.09
           DC-HSDPA Subtest-3           21.86   21.85   21.79   22.16     22.10    22.22    21.65    21.65     21.62
           DC-HSDPA Subtest-4           21.88   21.86   21.80   22.14     22.08    22.19    21.65    21.65     21.62
              HSUPA Subtest-1           22.12   22.15   21.90   22.16     22.24    22.18    21.64    21.84     21.66
              HSUPA Subtest-2           21.53   21.37   21.38   21.69     21.70    21.66    21.02    21.23     21.22
              HSUPA Subtest-3           21.23   20.92   20.96   21.40     21.31    21.59    20.93    20.81     20.93
              HSUPA Subtest-4           21.57   21.47   21.52   21.75     21.66    21.85    21.46    21.37     21.21
              HSUPA Subtest-5           22.50   22.20   22.40   22.80     22.80    22.90    22.30    22.30     22.30




Sporton International (Shenzhen) Inc.                                            Page Number        : A1 of A2
TEL : 86-755-8637-9589                                                           Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                           Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                   Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                                                   Report No. : FG8O1914-01A



      ERP/EIRP

                                        WCDMA Band V (GT - LC = 4.00 dBi)
                                                  4132                   4182                       4233
                Channel
                                                 (Low)                   (Mid)                     (High)
              Frequency
                                                  826.4                 836.4                       846.6
                 (MHz)
      Conducted Power (dBm)                       23.42                 23.53                       23.45
     Conducted Power (Watts)                     0.2198                 0.2254                     0.2213
              ERP(dBm)                            25.27                 25.38                       25.30
              ERP(Watts)                         0.3365                 0.3451                     0.3388



                                        WCDMA Band II (GT - LC = 4.00 dBi)
                                                  9262                   9400                       9538
                Channel
                                                 (Low)                   (Mid)                     (High)
              Frequency
                                                 1852.4                  1880                      1907.6
                 (MHz)

      Conducted Power (dBm)                       24.17                 24.02                       23.78

     Conducted Power (Watts)                     0.2612                 0.2523                     0.2388
              EIRP(dBm)                           28.17                 28.02                       27.78
             EIRP(Watts)                         0.6561                 0.6339                     0.5998


                                        WCDMA Band IV (GT - LC = 4.50 dBi)
                                                  1312                   1413                       1513
                Channel
                                                 (Low)                   (Mid)                     (High)
              Frequency
                                                 1712.4                 1732.6                     1752.6
                 (MHz)

      Conducted Power (dBm)                       23.74                 23.63                       23.65

     Conducted Power (Watts)                     0.2366                 0.2307                     0.2317
              EIRP(dBm)                           28.24                 28.13                       28.15
             EIRP(Watts)                         0.6668                 0.6501                     0.6531




Sporton International (Shenzhen) Inc.                                         Page Number        : A2 of A2
TEL : 86-755-8637-9589                                                        Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                                                        Report Version     : Rev. 01
FCC ID : ZMONL668AM00                                                Report Template No.: BU5-FG22/24/27 Version 2.0


              FCC RF Test Report                                                      Report No. : FG8O1914-01A



  Appendix B. Test Results of Radiated Test

  Radiated Spurious Emission
                                                 WCDMA Band V(RMC 12.2Kbps)
                                                      Over       SPA        S.G.      TX Cable    TX Antenna
          Frequency         ERP             Limit                                                            Polarization
Channel                                               Limit    Reading     Power        loss         Gain
            ( MHz )       ( dBm )         ( dBm )                                                               (H/V)
                                                      ( dB )    (dBm)     ( dBm )      ( dB )        (dBi)
            1672.8        -61.71           -13        -48.71    -72.08    -64.96        4.00          9.40            H
            2509.2        -65.20           -13        -52.20    -80.18    -68.77        4.88         10.60            H
            3345.6        -64.14           -13        -51.14    -81.11    -69.07        5.52         12.60            H
Middle
            1672.8        -63.15           -13        -50.15    -73.31    -66.40        4.00          9.40            V
            2509.2        -65.42           -13        -52.42    -80.25    -68.99        4.88         10.60            V
            3345.6        -64.09           -13        -51.09    -81.06    -69.02        5.52         12.60            V
  Remark: Spurious emissions within 30-1000MHz were found more than 20dB below limit line.


                                                 WCDMA Band II(RMC 12.2Kbps)
                                                      Over       SPA        S.G.      TX Cable    TX Antenna
          Frequency         EIRP            Limit                                                            Polarization
Channel                                               Limit    Reading     Power        loss         Gain
            ( MHz )       ( dBm )         ( dBm )                                                               (H/V)
                                                      ( dB )    (dBm)     ( dBm )      ( dB )        (dBi)
             3760         -60.42           -13        -47.42    -78.92    -67.17        5.85         12.60            H
             5640         -54.83           -13        -41.83    -77.00    -60.63        7.30         13.10            H
             7520         -54.89           -13        -41.89    -82.66    -58.04        8.35          11.50           H
Middle
             3760         -60.53           -13        -47.53    -79.07    -67.28        5.85         12.60            V
             5640         -54.60           -13        -41.60    -77.17    -60.40        7.30         13.10            V
             7520         -55.46           -13        -42.46    -83.04    -58.61        8.35          11.50           V
  Remark: Spurious emissions within 30-1000MHz were found more than 20dB below limit line.




  Sporton International (Shenzhen) Inc.                                            Page Number        : B1 of B2
  TEL : 86-755-8637-9589                                                           Report Issued Date : Dec. 19, 2018
  FAX : 86-755-8637-9595                                                           Report Version     : Rev. 01
  FCC ID : ZMONL668AM00                                                   Report Template No.: BU5-FG22/24/27 Version 2.0


              FCC RF Test Report                                                     Report No. : FG8O1914-01A



                                                 WCDMA Band IV(RMC 12.2Kbps)
                                                      Over       SPA       S.G.      TX Cable    TX Antenna
          Frequency         EIRP            Limit                                                           Polarization
Channel                                               Limit    Reading    Power        loss         Gain
            ( MHz )       ( dBm )         ( dBm )                                                              (H/V)
                                                      ( dB )    (dBm)    ( dBm )      ( dB )        (dBi)

            3465.2        -48.70           -13        -35.70   -65.82    -55.55        5.65         12.50            H
            5197.8        -55.07           -13        -42.07   -76.74    -60.74        7.13         12.80            H
            6930.4        -56.77           -13        -43.77   -83.57    -60.17        8.40          11.80           H
Middle
            3465.2        -48.96           -13        -35.96    -66.11   -55.81        5.65         12.50            V
            5197.8        -56.54           -13        -43.54   -78.66    -62.21        7.13         12.80            V
            6930.4        -56.71           -13        -43.71   -83.62    -60.11        8.40          11.80           V
  Remark: Spurious emissions within 30-1000MHz were found more than 20dB below limit line.




  Sporton International (Shenzhen) Inc.                                           Page Number        : B2 of B2
  TEL : 86-755-8637-9589                                                          Report Issued Date : Dec. 19, 2018
  FAX : 86-755-8637-9595                                                          Report Version     : Rev. 01
  FCC ID : ZMONL668AM00                                                  Report Template No.: BU5-FG22/24/27 Version 2.0


            FCC RF Test Report                      Report No. : FG8O1914-01A



Appendix D. Product Equality Declaration




Sporton International (Shenzhen) Inc.            Page Number        : D1 of D1
TEL : 86-755-8637-9589                           Report Issued Date : Dec. 19, 2018
FAX : 86-755-8637-9595                           Report Version     : Rev. 01
FCC ID : ZMONL668AM00                   Report Template No.: BU5-FG22/24/27 Version 2.0


                           Fibocom Wireless Inc.
            5/F, Tower A, Technology Building II, 1057# Nanhai Avenue, Shenzhen


                                                                   Date: December 19, 2018




                     Product Equality Declaration


We, Fibocom Wireless Inc., declare on our sole responsibility for the product of NL668-
AM-00 as below:


The differences between LCC and previous model, LCC are as below:
1,The power supply is different between LCC and previous model, LCC’s power supply is DC
power source by the ADP substrate , previous model’s power supply is MiniPCIe interface
2,The I/O interface is different between LCC and previous model, LCC’s I/O interface is ADP
substrate. previous model’s I/O interface is MiniPCIe interface
3,The RF antenna trace is different between LCC and previous model, LCC’s RF antenna trace
is ADP substrate. previous model’s RF antenna trace is MiniPCIe RF antenna trace


Except listings above, the others are all the same as previous version.
Should you have any questions or comments regarding this matter, please have my best
attention.


Sincerely yours,




Contact Person: XueShan Huang
Company: Fibocom Wireless Inc.
Tel: +8675526733555
Fax: +86-755-26520841


E-Mail: keith.huang@fibocom.com



Document Created: 2019-09-07 18:34:10
Document Modified: 2019-09-07 18:34:10

© 2024 FCC.report