RF Exposure report

FCC ID: V5PE700

RF Exposure Info

Download: PDF
FCCID_4407815

                                Test Report No.: SA190326W003-1



                                                  RF EXPOSURE REPORT
                              Product: Integrated Smart Terminal

                   Model Name: E700
                                FCC ID: V5PE700
                           Applicant: PAX Technology Limited
                             Address: Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road,
                                      Wanchai, Hong Kong
                  Manufacturer: PAX Computer Technology (Shenzhen) Co., Ltd.
                             Address: 4/F, No.3 Building, Software Park, Second Central
                                      Science-Tech Road, High-Tech industrial Park, Shenzhen,
                                      Guangdong, P.R.C.
                   Prepared by: BV 7Layers Communications Technology (Shenzhen) Co. Ltd
                 Lab Location: No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue,
                               North Area, Hi-Tech Industrial Park, Nanshan District,
                               Shenzhen, Guangdong, China
                                        TEL: +86 755 8869 6566
                                        FAX: +86 755 8869 6577
                                E-MAIL: customerservice.dg@cn.bureauveritas.com
                       Report No.: SA190326W003-1
              Received Date: Jul. 09, 2019
                          Test Date: Jul 18, 2019 ~ Jul 18, 2019
                    Issued Date: Jul 26, 2019

                                                                                                            This report should not be used by the client to claim
                                                                                                            product certification, approval, or endorsement by
                                                                                                            A2LA or any government agencies.


       This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
       http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any
       other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples
       identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
       identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
       Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by
       our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise
       such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                               No.B102, Dazu Chuangxin Mansion, North of Beihuan                                      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                               Avenue, North Area, Hi-Tech Industrial Park, Nanshan                                   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                                               District, Shenzhen, Guangdong, China                                                   Email: customerservice.dg@cn.bureauveritas.com

                                                                                                  Page 1 of 11                                                                  Report Version 1


                      Test Report No.: SA190326W003-1


       TABLE OF CONTENTS

       RF EXPOSURE REPORT ............................................................................................. 1
       RELEASE CONTROL RECORD .................................................................................. 3
       1            CERTIFICATION ............................................................................................ 4
       2            GENERAL INFORMATION ............................................................................ 5
         2.1 GENERAL DESCRIPTION OF EUT ................................................................... 5
       3      RF EXPOSURE .............................................................................................. 7
           3.1   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ............................ 7
           3.2   MPE CALCULATION FORMULA ....................................................................... 7
           3.3   CLASSIFICATION .............................................................................................. 7
           3.4   CONDUCTED POWER ...................................................................................... 8
           3.5   CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ..................... 9
           3.6   CONCLUSION OF SIMULTANEOUS TRANSMITTER .................................... 11




                                          No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                          Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                          District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                                Page 2 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1




                                       RELEASE CONTROL RECORD

        ISSUE NO.              REASON FOR CHANGE                                                         DATE ISSUED
        SA190326W003-1         Original release                                                          Jul 26, 2019




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 3 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1




       1 CERTIFICATION

                       PRODUCT: Integrated Smart Terminal
                 BRAND NAME: PAX
                 MODEL NAME: E700
                     APPLICANT: PAX Technology Limited
                        TESTED: Jul 18, 2019 ~ Jul 18, 2019
                TEST SAMPLE: Production Unit
                  STANDARDS: FCC Part 2 (Section 2.1091)
                                       FCC OET Bulletin 65, Supplement C (01-01)
                                       KDB 447498 D01 General RF Exposure Guidance v06
                                       IEEE C95.1




       The above equipment has been tested by BV 7Layers Communications
       Technology (Shenzhen) Co. Ltd and found compliance with the requirement of the
       above standards. The test record, data evaluation & Equipment Under Test (EUT)
       configurations represented herein are true and accurate accounts of the
       measurements of the sample’s EMC characteristics under the conditions specified in
       this report.




          PREPARED BY :                                                         ,    DATE:          Jul. 26, 2019
                                         (Alex Chen/ Engineer)




          APPROVED BY :                                                         ,    DATE:          Jul. 26, 2019
                                           (Luke Lu / Manager)




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 4 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1

       2 GENERAL INFORMATION
       2.1    GENERAL DESCRIPTION OF EUT
        PRODUCT                         Integrated Smart Terminal
        MODEL NAME                      E700
                                        24Vdc (adapter or host equipment)
        NOMINAL VOLTAGE
                                        3.63Vdc (Li-ion, battery)
        OPERATING
                          0 ~ 50℃
        TEMPERATURE RANGE
                                                             CCK, DQPSK, DBPSK for DSSS
                                        WLAN
                                                             64QAM, 16QAM, QPSK, BPSK for OFDM
                                        BT_LE                BT-LE for GFSK
                                        Bluetooth            GFSK, 8DPSK, π/4 DQPSK
        MODULATION TYPE
                                        WCDMA                BPSK/QPSK
                                        LTE                  QPSK, 16QAM
                                        RFID                 ASK
                                                             2412 ~ 2462MHz for 11b/g/n(HT20)
                                                             5180 ~ 5240MHz, 5260 ~ 5320 MHz,
                                        WLAN
                                                             5470 ~ 5700MHz, 5745 ~ 5825 MHz for 11a/
                                                             n(HT20)/ n(HT40) / ac(VHT80)
                                        Bluetooth/BT
                                                     2402MHz ~ 2480MHz
                                        _LE

        OPERATING                       RFID                 13.56MHz
        FREQUENCY
                                                             1852.4MHz ~ 1907.6MHz (FOR WCDMA II)
                                        WCDMA
                                                             826.4MHz ~ 846.6MHz (FOR WCDMA V)
                                                             1850.7MHz ~ 1909.3MHz (FOR LTE Band2)
                                                             1710.7MHz ~ 1754.3MHz (FOR LTE Band4)
                                        LTE                  824.7MHz ~ 848.3MHz (FOR LTE Band5)
                                                             699.7MHz ~ 715.3MHz (FOR LTE Band12)
                                                             706.5MHz ~ 713.5MHz (FOR LTE Band17)
                                        Bluetooth/BT
                                                     PIFA Antenna with 1.5dBi gain
                                        _LE
                                        WLAN 2.4G            PIFA Antenna with 1.5dBi gain
        ANTENNA GAIN
                                        WLAN 5G              PIFA Antenna with 1.5dBi gain for B1/ B2/ B3/ B4
                                        WCDMA V              Fixed Internal Antenna with 1.0dBi gain
                                        WCDMA II             Fixed Internal Antenna with 1.5dBi gain




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 5 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1

                                        LTE Band 2           Fixed Internal Antenna with 1.5dBi gain
                                        LTE Band 4           Fixed Internal Antenna with 1.5dBi gain
                                        LTE Band 5           Fixed Internal Antenna with 1.0dBi gain
                                        LTE Band 12          Fixed Internal Antenna with 1.0dBi gain
                                        LTE Band 17          Fixed Internal Antenna with 1.0dBi gain
        HW VERSION                      NA
        SW VERSION                      NA
        I/O PORTS                       Refer to user’s manual
        CABLE SUPPLIED                  N/A
       NOTE:
       1. For a more detailed features description, please refer to the manufacturer’s specifications or the
          user’s manual.
       2. The EUT was powered by the following adapter:
          ADAPTER
          BRAND:                   HONOTO
          MODEL:                   ADS-65HI-19A-3 24065E
          INPUT:                   AC 100-240V, 1.5A
          OUTPUT:                  DC 24V, 2.7A

       3.   For the test results, the EUT had been tested with all conditions. But only the worst case was
            shown in test report.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 6 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1



       3      RF EXPOSURE
       3.1    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
           FREQUENCY           ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                          AVERAGE TIME
           RANGE (MHz)         STRENGTH (V/m)         STRENGTH (A/m)    (Mw/cm2)                              (minutes)
                        LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
             300-1500                  …                        …                      F/1500                         30
           1500-100,000                …                        …                        1.0                          30

       F = Frequency in MHz

       3.2    MPE CALCULATION FORMULA
       Pd = (Pout*G) / (4*pi*r2)
       where
       Pd = power density in Mw/cm2
       Pout = output power to antenna in Mw
       G = gain of antenna in linear scale
       Pi = 3.1416
       R = distance between observation point and center of the radiator in cm


       3.3    CLASSIFICATION

       The antenna of this product, under normal use condition, is at least 20cm away from
       the body of the user. So, this device is classified as Mobile Device.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                       District, Shenzhen, Guangdong, China                    Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 7 of 11                                        Report Version 1


                     Test Report No.: SA190326W003-1

       3.4    CONDUCTED POWER

       TUNE-UP POWER TABLE


                                                                    Operating           Tune-Up Power
                                                Frequency
                                Band                                                    And Tolerance
                                                   (MHz)             Mode
                                                                                            (dBm)

                                  BT                2441               GFSK                    10.0
                                 BLE                2480               GFSK                    6.0
                              WIFI 2.4G             2437           11g(20MHz)                  24.0
                             WIFI 5G B1             5240           11a(20MHz)                  14.5
                             WIFI 5G B2             5320           11a(20MHz)                  15.0
                             WIFI 5G B3             5580           11a(20MHz)                  14.5
                             WIFI 5G B4             5825           11a(20MHz)                  12.5
                             WCDMA II              1907.6           RMC12.2K                   23.5
                             WCDMA V                846.6           RMC12.2K                   23.5
                                LTE 2               1900               QPSK                    23.0
                                LTE 4               1745               QPSK                    22.0
                                LTE 5               836.5              QPSK                    22.5
                               LTE 12                711               QPSK                    22.5
                               LTE 17                710               QPSK                    22.0




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                        District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                              Page 8 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1

       3.5    CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

       BT
                                         Antenna         Tune-up         E.I.R.P        Power
              Frequency Operating                                                                 limit   PASS /
    Band                                  Gain            Power          Power          Density
                 (MHz)   Mode                                                                   (mW/cm^2) FAIL
                                          (dBi)           (dBm)           (mW)        (mW/cm^2)
 Bluetooth        2441      BT_GFSK          1.5           10.0          14.125          0.003             1.00           PASS

       BLE
                                         Antenna         Tune-up         E.I.R.P        Power
              Frequency Operating                                                                 limit   PASS /
    Band                                  Gain            Power          Power          Density
                 (MHz)   Mode                                                                   (mW/cm^2) FAIL
                                          (dBi)           (dBm)           (mW)        (mW/cm^2)
     BLE          2441     BLE_GFSK          1.5            6.0           5.623           0.001            1.00           PASS


       WIFI 2.4G
                                         Antenna         Tune-up         E.I.R.P        Power
              Frequency Operating                                                                 limit   PASS /
    Band                                  Gain            Power          Power          Density
                 (MHz)   Mode                                                                   (mW/cm^2) FAIL
                                          (dBi)           (dBm)           (mW)        (mW/cm^2)
  WIFI 2.4G       2437          11b          1.5           24.0          354.81          0.071             1.00           PASS

       WIFI 5G
                                           Antenna       Tune-up          E.I.R.P        Power
                 Frequency Operating                                                               limit  PASS /
     Band                                   Gain          Power           Power          Density
                    (MHz)   Mode                                                                 (mW/cm^2) FAIL
                                            (dBi)         (dBm)            (mW)        (mW/cm^2)
  WIFI 5G B1        5240          11a          1.5          14.5          39.811          0.008             1.00          PASS
  WIFI 5G B2        5320          11a          1.5          15.0          44.668          0.009             1.00          PASS
  WIFI 5G B3        5580          11a          1.5          14.5          39.811          0.008             1.00          PASS
  WIFI 5G B4        5825          11a          1.5          12.5          25.119          0.005             1.00          PASS

       WCDMA
                                        Antenna         Tune-up          E.I.R.P        Power
              Frequency Operating                                                                 limit   PASS /
    Band                                 Gain            Power           Power          Density
                 (MHz)   Mode                                                                   (mW/cm^2) FAIL
                                         (dBi)           (dBm)            (mW)        (mW/cm^2)
 WCDMA II        1907.6    RMC12.2K         1.0           23.5           281.838         0.056             0.56           PASS
 WCDMA V         846.6     RMC12.2K         1.5           23.5           316.228         0.063             1.00           PASS

       LTE
                                           Antenna       Tune-up          E.I.R.P        Power
                 Frequency Operating                                                               limit  PASS /
     Band                                   Gain          Power           Power          Density
                    (MHz)   Mode                                                                 (mW/cm^2) FAIL
                                            (dBi)         (dBm)            (mW)        (mW/cm^2)
     Band 2         1900         QPSK          1.5          23.0         281.838          0.056             1.00          PASS




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                        District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                              Page 9 of 11                                       Report Version 1


                     Test Report No.: SA190326W003-1

     Band 4         1745         QPSK          1.5         22.00         223.872          0.045             1.00          PASS
     Band 5         836.5        QPSK          1.0         23.00         251.189          0.050             0.56          PASS
    Band 12          711         QPSK          1.0         23.00         251.189          0.050             0.47          PASS
    Band 17          710         QPSK          1.0         22.00         199.526          0.040             0.47          PASS




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                        District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                             Page 10 of 11                                        Report Version 1


                     Test Report No.: SA190326W003-1

       3.6    CONCLUSION OF SIMULTANEOUS TRANSMITTER



       Both of the WLAN and plug-in device can transmit simultaneously, the formula of
       calculated the MPE is:


       CPD1/LPD1+CPD2/LPD2+……etc. < 1
       CPD = Calculation power density
       LPD = Limit of power density


       Therefore the worst-case situation is, which is less than “1”, This confirmed that the
       device comply with FCC 1.1310 MPE limit.

                                                                                             Total
                  Frequency Power Density   limit   Power Density                                               MPE
     Band                    (mW/cm^2)    (mW/cm^2)
                                                                                         Power Density          Limit
                                                                                                                          PASS / FAIL
                    ( MHz )                            / Limit
                                                                                            / Limit

     WIFI
                     2437              0.071              1              0.071
   2.4G-11b                                                                                     0.127           1.000          PASS
  LTE Band 2         1880              0.056              1              0.056




       --END--




                                         No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                         Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd
                                         District, Shenzhen, Guangdong, China                   Email: customerservice.dg@cn.bureauveritas.com

                                                              Page 11 of 11                                        Report Version 1