CCISE190808701V01

FCC ID: V5PCM204GW

Test Report

Download: PDF
FCCID_4484792

M Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                            Report No: CCISE190808701V01



                                                FCC REPORT
                                                              (WCDMA)
Applicant:                                  PAX Technology Limited

                                            Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road,
Address of Applicant:
                                            Wanchai, Hong Kong

Equipment Under Test (EUT)

     Product Name:                          Communication Module

     Model No.:                             CM20

     Trade mark:                            PAX

FCC ID:                                     VSPCM2O04GW

                                            FCC     CFR     Title   47   Part   2
                                            FCC     CFR     Title   47   Part   22 Subpart H
Applicable standards:
                                            FCC     CFR     Title   47   Part   24 Subpart E
                                            FCC     CFR     Title   47   Part   27 Subpart L
Date of sample receipt:                     23 Aug., 2019

Date of Test:                               24 Aug., to 16 Sep., 2019

Date of report issued:                      18 Oct., 2019

Test Result:                                PASS*
+
      In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




         Bruce Zhang
       Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the preduct in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are refained for 90 days
only.


c c I s                                                                      Report No: CCISE190808701V0O1


2. Version
      Version No.                              Date                                   Description
             00                          17 Sep., 2019                                  Original
             01                          18 Oct., 2019                           Update page 4, page 26




  Tested by:                        M tlkGe—OU                           vate:             18 Oct., 2019
                                       Test Engineer


  Reviewed by:                      ww¥ M                                Date:             18 Oct., 2019
                                     Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 2 of 30


c c I s                                                                                          Report No: CCISE190808701V01

3. Contents
                                                                                                                                                    Page
1.         COVER PAGE                                                                                                                                    1
2.         VERSION                                                                                                                                       2
3.         CONTENTS                                                                                                                                      3
4.         TEST SUMMARY                                                                                                                                  4
5.     GENERAL INFORMATION                                                                                                                               5
     5.1      CLIENT INFORMATION :2200 00 0000000 n en en en n n n n n n ns nnnennnennnennnennnennnennne snn enneenneeseeeseeeseeeseeeseeeseeennencernees 5
     5.2      GENERAL DESCRIPTION OF E. U.T                                                                                                           «225
     5.3      TEST MODES ns ecccccncmememees.                                                                                                             7
     5.4      DESCRIPTION OF SupPoRt Units                                                                                                                7
     5.5      MEASUREMENT UNCERTAINTY.                                                                                                                    7
     5.6      LABORATORY FACILITY......                                                                                                                   7
     5.7      LABORATORY LOCATION                                                                                                                         8
     5.8      TEST INSTRUMENTS LIST...                                                                                                                    8
6.     TEST RESULTS                                                                                                                                      9
     6.1      CoONDUCTED QUTPuT PoOWER, ERP AND EIRP ..
     6.2      PEAK—TO—AvERAGE POWER RATIO
     6.3      OCCUPY BANDWIDTH .....
     6.4      MODULATION CHARACTERISTIC
     6.5      OUT OF BAND EMISSION AT ANTENNA TERMINALS
     6.6      FIELD STRENGTH OF SPURIOUS RADIATION MEASUREMENT
     6.7      FREQUENCY STABILITY V.S. TEMPERATURE MEASUREMENT.
     6.8      FREQUENCY STABILITY V.S. VOLTAGE MEASUREMENT .........

7      TEST SETUP PHOTO                                                                                                                                 21
8      EUT CONSTRUCTIONAL DETAILS                                                                                                                       22




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                                            Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                  Page 3 of 30


CCIS                                                                         Report No : CCISE190808701V01

4. Test Summary
                    Test Item                                   Section in CFR 47                Result
                                                                                                  Pass
                                                                    Part 1.1310
               RF Exposure (SAR)                                                             (Please refer to
                                                                    Part 2.1091
                                                                                              MPE Report)
                                                                     Part 21046
                                                                 Part 22.913 (a)(5)
                RF Output Power                                                                   Pass*
                                                                   Part 24.232 (c)
                                                                  Part 27.50 (d)(4)
                                                                   Part 24.232 (d)
         Peak—to—Average Power Ratio                                                              Pass*
                                                                  Part 27.50(d)(5)
           Modulation Characteristics                               Part 2.1047                   Pass
                                                                    Part 21049
                                                                  Part 22.917(b)
      99% & —26 dB Occupied Bandwidth                                                             Pass*
                                                                  Part 24.238(b)
                                                                   Part 27.53(h)
                                                                    Part 21053
                                                                  Part 22.917 (a)
  Out of band emission at antenna terminals                                                       Pass*
                                                                  Part 24.238 (a)
                                                                   Part 27.53 (h)
                                                                  Part 22.917 (a)
       Field strength of spurious radiation                       Part 24.238 (a)                 Pass
                                                                   Part 27.53 (h)
                                                                   Part 22.355
                                                                   Part 24.235
      Frequency stability vs. temperature                                                         Pass*
                                                                    Part 27.54
                                                               Part 2.1055(a)(1)(b)
                                                                   Part 22.355
                                                                   Part 24.235
         Frequency stability vs. voltage                                                          Pass*
                                                                    Part 27.54
                                                                Part 21055(d)(2)
 Pass: The EUT complies with the essential requirements in the standard.
 Pass*: please refer to FCC ID: ZMONLEGG8AMOO, Report No.: FG8O1914—01A.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 4 of 30


CCIS                                                                     Report No: CCISE190808701V01

5. General Information
5.1 Client Information
        Applicant:                         PAX Technology Limited
        Address:                           Room 2416, 24/F., Sun Hung Kai Centre, 30 Harbour Road, Wanchai,
                                           Hong Kong
        Manufacturer:                      PAX Computer Technology (Shenzhen) Co., Ltd.
        Address:                           401—402 No.3 Building, Software Park, Nanshandistrict, Shenzhen,
                                           Guangdong, P.R.C.

5.2 General Description of E.U.T.
        Product Name:                     Communication Module
        Model No.:                        CM20
        Operation Frequency range:        WCDMA Band V: 826.4MHz—846.6MHz
                                          WCDMA Band II: 1852.4 MHz—1907.6 MHz
                                          WCDMA Band IV: 1712.4 MHz—1752.6 MHz
        Modulation type:                  UMTS: QPSK
        Antenna type:                     External Antenna
        Antenna gain:                     WCDMA Band V: 0.5 dBi
                                          WCDMA Band II: 1.0 dBi
                                          WCDMA Band IV: 1.0 dBi
        Adapter:                          Model: GLHO901000
                                          Input: AC100—240V, 50/60H2z, 0.5A
                                          Output: DC 9.0V, 1.0A
        Test Sample Condition:            The test samples were provided in good working order with no visible
                                          defects.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 5 of 30


c c I s                                                                        Report No: CCISE190808701V01

Operation Frequency List:
                     WCDMA Band V                                                  WCDMA Band 1
          Channel                   Frequency (MHz)                      Channel                 Frequency (MHz)
            4132                          826.40                          9262                       1852.40
            4133                          826.60                          9263                       1852.60

            4182                          836.40                          9399                       1879.80
            4183                          836.60                          9400                       1880.00
            4184                          836.80                          9401                       1880.20

            4232                          846.40                          9537                       1907.40
            4233                          846.60                          9538                       1907.60
                     WCDMA Band IV
          Channel                   Frequency (MHz)
            1312                         1712.40
            1318                         1712.60

            1412                         1732.40
            1413                         1732.60
            1414                         1732.80

            1512                         1752.40
            1513                         1752.60

Regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the
highest frequency of channel were selected to perform the test, and the selected channel see below:
                     WCDMA Band V                                                  WCDMA Band II
                Channel                  Frequency(MHz)                       Channel               Frequency(MHz)
      Lowest            4132                   826.40               Lowest              9262             1852.40
      Middle            4183                   836.60               Middle              9400             1880.00
      Highest           4233                   846.60               Highest             9538             1907.60
                     WCDMA Band IV
                Channel                  Frequency(MHz)
      Lowest               1312               1712.40
      Middle               1413               1732.60
      Highest              1513               1752.60




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 6 of 30


c c I s                                                                        Report No: CCISE190808701V01

5.3 Test modes
       Operating Environment:
       Temperature:           Normal: 15°C ~35°C, Extreme: —30°C ~+50°C
       Humidity:                    20 % ~ 75 % RH
       Atmospheric Pressure:        1008 mbar
       Voltage:                     Nominal: 120Vac, Extreme: Low 102 Vac, High 138 Vac
       Test mode:
       RMC mode               Keep the EUT communication with simulated station in RMC mode
       HSDPA                  Keep the EUT communication with simulated station in HSDPA mode
       HSUPA                  Keep the EUT communication with simulated station in HSUPA mode
       Remark: The EUT has been tested under continuous transmitting mode. Channel Low, Mid and High for
       each type band with rated data rate were chosen for full testing. The field strength of spurious radiation
       emission was measured as EUT stand—up position (H mode) and lie down position (E1, E2 mode) for
       these modes with power adaptor, earphone and Data cable. Just the worst case position (H mode)
       shown in report.

5.4 Description of Support Units
    Test Equipment                  Manufacturer                         Model No.                  Serial No.
    Simulated Station                   Anritsu                          MT8820C                    6201026545

5.5 Measurement Uncertainty
                    Parameters                                                  Expanded Uncertainty
         Radiated Emission (OkHz ~ 3OMHz)                                          +3.12 dB (k=2)
       Radiated Emission (3OMHz ~ 1000MHz)                                         +4.32 dB (k=2)
         Radiated Emission (1GHz ~ 18GHz)                                          +5.38 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                          +3.36 dB (k=2)
5.6 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ® FCC — Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        ®@ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A—1.
        © CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
       ®     A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https/portal.a2la.org/scopepdf/4346—0 1. pdf




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 7 of 30


CCIS                                                                            Report No: CCISE190808701V01

5.7 Laboratory Location
          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
          Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
          Bac‘an District, Shenzhen, Guangdong, China
          Tel: +86—755—23118282, Fax: +86—755—23116366
          Email: info@ccis—cb.com, Website: http—//www.ccis—cb.com

5.8 Test Instruments list
   Test Equipment           Manufacturer            Model No.              Serial No.       ("(::‘I::(:;)     c(:'mD_l;Z_dya;e

          3m SAC               SAEMC                9m*6m*6m                  966           07—22—2017         07—21—2020
  BiConiLog Antenna        SCHWARZBECK              VULB3163                  497           03—18—2019         03—17—2020
   Biconical Antenna       SCHWARZBECK              VUBAQ117                  359           06—22—2017         06—21—2020
        Horn Antenna       SCHWARZBECK             BBHAY120D                  916           03—18—2019         03—17—2020
        Horn Antenna       SCHWARZBECK             BBHA9Y120D                1805           06—22—2017         06—21—2020
        Horn Antenna       SCHWARZBECK              BBHA 9170            BBHAY170582        11—21—2018         11—20—2019
  EMI Test Software             AUDIX                    E3                              Version: 6.110919b
        Pre—amplifier             HP                  8447D               2944409358        03—18—2019         03—17—2020
        Pre—amplifier             CD                PAP—1G18                 11804          03—18—2019         03—17—2020
  Spectrum analyzer        Rohde & Schwarz            FSP30                 101454          03—18—2019         03—17—2020
  Spectrum analyzer        Rohde & Schwarz            FSP40                 100363          11—21—2018         11—20—2019
  EMI Test Receiver        Rohde & Schwarz            ESRPY                 101070          03—18—2019         03—17—2020
  Spectrum Analyzer             Agilent               N9020A              MY50510123        11—10—2018         11—09—2019
   Signal Generator        Rohde & Schwarz             SMX                835454/016        03—18—2019         03—17—2020
   Signal Generator             R&S                   SMR20               1008100050        03—18—2019         03—17—2020
    RFE Switch Unit          MWRETEST                 MW200                   N/A               N/A               N/A
        Test Software        MWRETEST                MTS8200                              Version: 2.0.0.0
           Cable                ZDECL             2108—NJ—NJ—81             1608458         03—18—2019         03—17—2020
           Cable            MICRO—COAX              MER64G39               K10742—5         03—18—2019         03—17—2020
        Cable                  SUHNER             SUCOFLEX100              58193/4PE        03—18—2019         03—17—2020
   DC Power Supply             XinNuoEr            WYK—10020K            1409050110020      10—31—2018         10—30—2019
        Temperature
  Humidity Chamber
                                HengPu              HPabs—s00            20140828008        09—24—2018         09—23—2019
    ;               ;                                                                       07—16—2018         07—15—2019
   Simulated Station       Rohde & Schwarz           CMW500                 140493          0r—16—2019         07—15—2020




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 8 of 30


CCIS                                                                        Report No: CCISE190808701V01

6. Test results
6.1 Conducted Output Power, ERP and EIRP
       Test Requirement:                 FCC part 22.913(a)(5), FCC part 24.232(c), FCC part 27.50(d)(4)
       Test Method:                     ANSUTIA—603—D 2010
       Limit:                           WCDMA Band V: 7W, WCDMA Band II: 2W, WCDMA Band IV: 1W
       Test setup:




                                           C               TCJ
                                                                            ATT
                                           System simulator                                       EUT
       Test Procedure:                  The transmitter output was connected to a calibrated attenuator, the other
                                        end of which was connected to the simulated station. Transmitter output
                                        power was read off in dBm.
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details
                                        Conducted Output Power is Refer to FCC ID: ZMONL668AMOOY, Report
       Test results:
                                         No.: FG8O1914—01A. Only retest ERP and EIRP




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 9 of 30


CCIS                                                                                Report No: CCISE190808701V01

Measurement Data:
                                                                                    Burst Average power (dBm)
                           EUT Mode                                     4132                  4183                  4233
                                                                    826.40 (MHz)          836.60 (MHz)          846.60 (MHz)
                                               Subtest 1                22.58                22.52                  22.49
              UMTS 850                         Subtest 2                22.62                22.60                  22.54
               HSDPA                           Subtest 3                22.12                22.12                  22.04
                                               Subtest 4                22.18                22.12                  22.05
                                               Subtest 1                22.31                22.24                  22.23
              UMTS 850                         Subtest 2                22.36                22.38                  22.29
             DC—HSDPA                          Subtest 3                21.86                21.85                  21.79
                                               Subtest 4                21.88                21.86                  21.80
                                               Subtest 1                22.12                22.15                  21.90
                                               Subtest 2                21.59                21.37                  21.38
              UMTS 850                         Subtest 3                21.23                20.92                  20.96
               HSUPA
                                               Subtest 4                21.57                21.47                  21.52
                                               Subtest 5                22.50                22.20                  22.40
          UMTS 850 RMC                          12.2kbps                23.42                23.59                  28.45
                      Antenna Gain (dBi)                                                      0.5
                       Max. ERP (dBm)                                                        24.03
                       ERP Limit (dBm)                                                       38.45



                                                                                    Burst Average power (dBm)
                           EUT Mode                                     9262                   9400                 9538
                                                                    1852.40 (MHz)        1880.00 (MHz)          1907.60 (MHz)
                                               Subtest 1                22.87                22.76                  22.89
             UMTS 1900                         Subtest 2                22.88                22.82                  22.85
              HSDPA                            Subtest 3                22.40                22.35                  22.47
                                               Subtest 4                22.38                22.34                  22.45
                                               Subtest 1                22.63                22.52                  22.65
             UMTS 1900                         Subtest 2                22.64                22.57                  22.60
             DC—HSDPA                          Subtest 3                22.16                22.10                  22.22
                                               Subtest 4                22.14                22.08                  22.19
                                               Subtest 1                22.16                22.24                  22.18
                                               Subtest 2                21.69                21.70                  21.66
             UMTS 1900                         Subtest 3                21.40                21.31                  21.59
               HSUPA
                                               Subtest 4                21.75                21.66                  21.85
                                               Subtest 5                22.80                22.80                  22.90
          UMTS 1900 RMC                         12.2kbps                24.17                24.02                  23.78
                      Antenna Gain (dBi)                                                      1.0
                       Max. EIRP (dBm)                                                       25.17
                       EIRP Limit (dBm)                                                      33.00
 Note: Burst Average power (dBm) is Refer to FCC ID: ZMONLEESAMOO
      EIAP (dBm) = Burst Average power(dBm) + Antenna Gain (dB)).
      EAP (dBm ) = EIRP (dBm) — 2.15 (dB),




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 10 of 30


c c I s                                                                             Report No: CCISE190808701V01


                                                                                    Burst Average power (dBm)
                          EUT Mode                                      1312                  1412                  1513
                                                                    1712.40 (MHz)         1732.40 (MHz)         1752.60 (MHz)
                                               Subtest 1                22.38                 22.44                 22.41
             UMTS 1700                         Subtest 2                22.39                 22.40                 22.35
              HSDPA                            Subtest 3                21.92                 21.93                 21.88
                                               Subtest 4                21.91                 21.92                 21.88
                                               Subtest 1                22.12                 22.18                 22.16
             UMTS 1700                         Subtest 2                22.12                 22.12                 22.09
             DC—HSDPA                          Subtest 3                21.65                 21.65                 21.62
                                               Subtest 4                21.65                 21.65                 21.62
                                               Subtest 1                21.64                 21.84                 21.66
                                               Subtest 2                21.02                 21.23                 21.22
             UT'ESU;ZOO                        Subtest 3                20.93                 20.81                 20.93
                                               Subtest 4                21.46                 21.97                 21.21
                                               Subtest 5                22.90                 22.30                 22.30
          UMTS 1700 RMC                         12.2bps                 23.74                 28.63                 28.65
                     Antenna Gain (dBi)                                                        1.0
                      Max. EIRP (dBm)                                                         24.74
                      EIRP Limit (dBm)                                                        30.00
 Note: Burst Average power (dBm) is Refer to FCC ID: ZMONLEESAMOO
      EIRP (dBm} = Burst Average power(dBm) + Anterna Gain (dB)).




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 11 of 30


CCIS                                                                        Report No: CCISE190808701V01

6.2 Peak—to—Average Power Ratio
       Test Requirement:                 FCC part 24.232(d), FCC part 27.50(d)(5)
       Test Method                       ANSUTIA—603—D 2010
        Limit:                           The peak—to—average ratio (PAR) of the transmission may not exceed 13
              '                          dB.
       Test setup:




                                             C              C

                                             System simulator                                       :


                                                                               Splitter    4T
                                                                                                        EUT
                                             C              TCJ

                                             Spectrum Analyzer
       Test Procedure:                   1     The RF output of the transceiver was connected to a spectrum
                                               analyzer through appropriate attenuation.
                                         2     Set the CCDF option in spectrum analyzer, RBW 2 OBW,
                                         3     Set the EUT working in highest power level, measured and recorded
                                               the 0.1% as PAPR level.
                                         4     Repeat step 1~3 at other frequency and modulations.
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details
       Test results:                     Refer to FCC ID: ZMONL6G8AMOOY, Report No.: FG8O1914—01A.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 12 of 30


c c I s                                                                       Report No: CCISE190808701V01

6.3 Occupy Bandwidth
       Test Requirement:                 FCC part 22.917(b), FCC part 24.238(b), FCC Part 27.53(h)
       Test Method:                     ANSUTIA—603—D 2010
       Test setup:




                                              &              C


                                              System simulator                                        :


                                                                                  Splitter   4T
                                                                                                          EUT
                                              C              TCJ

                                              Spectrum Analyzer
       Test Procedure:                   1.     The EUT‘s output RF connector was connected with a short cable to
                                                the spectrum analyzer
                                        2.      RBW was set to about 1% of emission BW, VBW= 3 times RBW.
                                        3.       —26dBe display line was placed on the sereen (or 99% bandwidth),
                                                the occupied bandwidth is the delta frequency between the two
                                                points where the display line intersects the signal trace.
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details
       Test results:                     Refer to FCC ID: ZMONL668AMOOY, Report No.: FG8O1914—01A.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 13 of 30


c c I s                                                                     Report No: CCISE190808701V01

6.4 Modulation Characteristic
    According to FCC § 2.1047(d), Part 22H & 24E & 27L there is no specific requirement for digital modulation,
    therefore modulation characteristic is not presented.

6.5 Out of band emission at antenna terminals
       Test Requirement:                 FCC part 22.917(a), FCC part 24.238(a), FCC Part 27.53 (h)
       Test Method:                     ANSUTIA—603—D 2010
       Limit:                           —13dBm
       Test setup:




                                             &              C


                                             System simulator                                     :


                                                                              Splitter   4T
                                                                                                      EUT
                                             C              TCJ

                                             Spectrum Analyzer
       Test Procedure:                   1     The RF output of the transceiver was connected to a spectrum
                                               analyzer through appropriate attenuation.
                                        2      The resolution bandwidth of the spectrum analyzer was set at 100
                                               kHz when below 1GHz, 1MHz when above 1 GHz; sufficient scans
                                               were taken to show the out of band Emissions if any up to 10th
                                               harmonic.
                                        3      For the out of band: Set the RBW=100 kHz, VBW=300 kHz when
                                               below 1 GHz, RBW =1 MHz, VBW=3 MHz when above 1 GHz,
                                               Start=30MHz, Stop= 10th harmonic.
                                        4      Band Edge Requirements: in the 1 MHz bands immediately outside
                                               and adjacent to the frequency block, a resolution bandwidth of at
                                               least 1 percent of the emission bandwidth of the fundamental
                                               emission of the transmitter may be employed to measure the out of
                                               band Emissions.
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details
       Test results:                     Refer to FCC ID: ZMONL668AMOOY, Report No.: FG8O1914—01A.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 14 of 30


CCIS                                                                                        Report No: CCISE190808701V01

6.6 Field strength of spurious radiation measurement
       Test Requirement:                 FCC       part 22.917(a), FCC part 24.238(a), FCC part 27.53(h)
       Test Method:                     ANSUTIA—603—D 2010
       Limit:                           —13dBm
       Test setup:                       Below 1GHz
                                              [=           Cooe                                                                  ;


                                                                                                                                 i
                                                                                             Amtoona       | _                   ]
                                                                 _                             %X           monna Tover          1
                                                            C| 5t                                      |                         i
                                                      I mss [(AAA/AA/J li&::
                                                                          24|                                                    1
                                                                  Ground RetvercePlane    sge
                                                                                         Generator
                                                                                         wet—|amter)—


                                        Above 1GHz

                                                                                                                             )
                                                                                                                           <_|
                                                                                                                             I
                                                                                                                             4


                                                           z>   [E                                                          A|


                                                                     |
                                                       |             |                                                      a


                                                                     estReceri


       Test Procedure:                   1.        The EUT was placed on an non—conductive turntable using a non—
                                                   conductive support. The radiated emission at the fundamental
                                                   frequency was measured at 3 m with a test antenna and EMI
                                                   spectrum analyzer.
                                                   During the tests, the antenna height and the EUT azimuth were
                                                   varied in order to identify the maximum level of emissions from the
                                                   EUT. This maximization process was repeated with the EUT
                                                   positioned in each of its three orthogonal orientations.
                                                   The frequency range up to tenth harmonic was investigated for each
                                                   of three fundamental frequency (Jow, middle and high channels).
                                                   Once spurious emission was identified, the power of the emission
                                                   was determined using the substitution method.
                                                   The spurious emissions attenuation was calculated as the difference
                                                   between radiated power at the fundamental frequency and the
                                                   spurious emissions frequency.
                                                    ERP / EIRP = $.G. output (dBm) + Antenna Gain{dB/dBi) —
                                                    Cable Loss (dB)
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details.
       Test results:                     Passed




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                                              Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                             Page 15 of 30


CCIS                                                                            Report No: CCISE190808701V01

Measurement Data (worst case):

                                                WCDMA BAND V 12.2k RMC
                                                      Lowest channel
                                           Spurious Emission                         2.
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
          1652.80                   Vertical                  —59.12
         2479.20                       V                      —51.63                   —13.00                 Pass
         3305.60                       V                      —51.84
          1652.80                 Horizontal                  —58.75
         2479.20                       H                      —50.71                   —13.00                 Pass
         3305.60                       H                      —51.5
                                                      Middle channel
                                         Spurious Emission                           20.
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization          Level (dBm)
          1673.20                   Vertical                  —59.84
         2509.80                       V                      —51.48                   —13.00                 Pass
         3346.40                       V                      —51.69
          1673.20                 Horizontal                  —58.67
         2509.80                       H                      —50.83                   —13.00                 Pass
         3346.40                       H                      —51.34
                                                      Highest channel
                                           Spurious Emission                         2.
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
          1693.20                   Vertical                  —59.76
         2539.80                       V                      —51.54                   —13.00                 Pass
         3386.40                       V                      —51.73
          1693.20                 Horizontal                  —58.69
         2539.80                       H                      —50.87                   —13.00                 Pass
         3386.40                       H                      —51.38
 Remark:
 1.     The emission levels of below 1 GHz are very lowerthan the limit and not show in test report.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 16 of 30


c c I s                                                                         Report No: CCISE190808701V01


                                                WCDMA Band II 12.2k RMC
                                                      Lowest channel
                                           Spurious Emission
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
         3704.80                    Vertical                  —50.13
         5557.20
                                     eNCZ
                                      V                       ~44.55
                                                                                       —13.00                 Pass
         3704.80                  Horizontal                  —49.16
                                                                                       —13.00                 Pass
         5557.20                       H                      —43.67
                                                      Middle channel
                                           Spurious Emission
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
         3760.00                    Vertical                  —50.16
                                                                                       —13.00                 Pass
         5640.00                       V                      ~44.87
         3760.00                  Horizontal                  —49.23
                                                                                       —13.00                 Pass
         5640.00                       H                      —43.68
                                                      Highest channel
                                           Spurious Emission
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
         3815.20                    Vertical                  —49.38
                                                                                       —13.00                 Pass
         5722.80                       V                      —44.89
         3815.20                  Horizontal                  —49.37
                                                                                       —13.00                 Pass
         5722.80                       H                      —43.72
 Remark:
 1.     The emission levels of below 1 GHz are very lowerthan the limit and not show in test report.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 17 of 30


c c I s                                                                         Report No: CCISE190808701V01


                                                WCDMA Band IV 12.2k RMC
                                                      Lowest channel
                                           Spurious Emission                         20
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
                                    Vertical                  —48.89
         342440                      e1c2                                              —13.00                 Pass
         5136.60                       V                       —44
                                  Horizontal                  —47.73
         8424.40                                                                       —13.00                 Pass
         5136.60                       H                      —40.35
                                                      Middle channel
                                           Spurious Emission
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
                                    Vertical                  —48.96
         8464.80                                                                       —13.00                 Pass
         5197.20                       V                      —44.24
                                  Horizontal                  —47.56
         3464.80                                                                       —13.00                 Pass
         5197.20                       H                      —40.68
                                                      Highest channel
                                           Spurious Emission
      Frequency (MHz)                 ——                                            Limit (dBm)              Result
                                 Polarization              Level (dBm)
                                    Vertical                  —49.21
         8505.20                                                                       —13.00                 Pass
         5257.80                       V                      —44.86
                                  Horizontal                  —47.58
         8505.20                                                                       —13.00                 Pass
         5257.80                       H                      —40.72
 Remark:
 1.     The emission levels of below 1 GHz are very lowerthan the limit and not show in test report.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 18 of 30


c c I s                                                                       Report No: CCISE190808701V01

6.7 Frequency stability V.S. Temperature measurement
       Test Requirement:                 FCC Part 22.355, FCC Part 24.235, FCC Part 27.54,
                                         FCC Part 2.1055(a)(1)(b)
       Test Method:                     ANSUTIA—6—3—D 2010
       Limit:                           £2.5 ppm for WCDMA 850
                                        Within authorized band for W1900 and W1700



       CUTT                              D—|_q
                                              SS




                                              SA




                                                                                           Temperature & Humidity Chamber




                                                                            Power Source

       Test procedure:                   1.   The equipment under test was connected to an external DC power
                                              supply and input rated voltage.
                                        2.    RF output was connected to a frequency counter or spectrum
                                              analyzer via feed through attenuators.
                                        3.    The EUT was placed inside the temperature chamber.
                                        4.     Set the spectrum analyzer RBW low enough to obtain the desired
                                              frequency resolution and measure EUT 25°C operating frequency as
                                              reference frequency.
                                        5.    Turn EUT off and set the chamber temperature to —30°C. After the
                                              temperature stabilized for approximately 30 minutes recorded the
                                              frequency.
                                        6.    Repeat step measure with 10°C increased per stage until the highest
                                              temperature of +50°C reached
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details
       Test results:                     Refer to FCC ID: ZMONL668AMOOY, Report No.: FG8O1914—01A.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 19 of 30


c c I s                                                                       Report No: CCISE190808701V01

6.8 Frequency stability V.S. Voltage measurement
       Test Requirement:                 FCC Part 22.355, FCC Part 24.235, FCC Part 27.54,
                                         FCC Part 2.1055(d)(2)
       Test Method:                     ANSUTIA—603—D 2010
                                        +2.5 ppm for WCDMA 850
       Limit:
                                        Within authorized band for W1900 and W1700
       Test setup:


                                              SS                I_U




                                                                                           Temperature & Humidity Chamber




                                                                            Power Source


       Test procedure:                   1.   Set chamber temperature to 25°C. Use a variable DC power source
                                              to power the EUT and set the voltage to rated voltage.
                                        2.     Set the spectrum analyzer RBW low enough to obtain the desired
                                              frequency resolution and recorded the frequency.
                                        3.     Reduce the input voltage to specify extreme voltage variation (+/—
                                              15%) and endpoint, record the maximum frequency change.
       Test Instruments:                 Refer to section 5.8 for details
       Test mode:                        Refer to section 5.3 for details
       Test results:                     Refer to FCC ID: ZMONL6G8AMOO, Report No.: FG8O1914—01A.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 20 of 30


                                                                         Report No: CCISE190808701V01


                                             Radiated Spurious Emission
                                                     Below 1GHz




                                                       Above 1GHz




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                        Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                       Page 21 of 30


c c I s                                                                  Report No: CCISE190808701V01

8    EUT Constructional Details




                                                                                                      PE ET
                                                                                              ooo T
                                                                                                      oo
               YAAA pasnng un PFi sn ooo y sys uce    Ns
                Jnd:JsJuu&sosmocozmobzoe n Ne eSA CAL h




                                                                                             s 9N 2
                                                                                   |Il|ll|
                                                                                   *




                                                                                  m|Q_
                UOZ 06 08 0 09 OS or 0t o2 0: 00| 06 o8 oz o9 os or o6 0Z 01




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 22 of 30


c c I s                                                                                       Report No: CCISE190808701V01




                                                                              001 o1 oz C
                                                                         C
                                                                         8




                                                                                             ut
                                                                         8
                                                                         [3




                                                                                 o5 09 OL us 06
                                                                         8
                                                                         8
                                                                         8
                                                                         E




                                     bouid
                                                                                                      CC




                                     Uss—Host
                                                                                                  iJ 2&




              oi ocar) |r||°-




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                                               Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                              Page 23 of 30


c c I s                                                                                   Report No: CCISE190808701V01




                                                                                                     Oz O€ O# OS 09 0Z |
                                                 omax
                                                 Model : CM20                    .l




                                                                                                    Oc uad)
                                                 LoBbEsr
                                                MX Computer Tchnology (Shenthon) o.lad.
                                                                                 Leo




               e o cssc




                         in




                                                                                               EW

               OO C OS s sA d




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                  Page 24 of 30


c c I s                                                                  Report No: CCISE190808701V01




                  06 O82 Oc                  o9 —Os=oOovr oc ot o.




                                                   a.a. a
                                                  eniucmnmnra




                                                                                hoR
                d6 08 Oc o9 oOs or os otu &\




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 25 of 30


CCGIS                                                                      Report No: CCISE190808701V01




                                                                                   e

                    d6       OS       oLr—og            oOs      ov      ost at a.




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 26 of 30


c c I s                                                                  Report No: CCISE190808701V01




                                                                                 C ied Eonse o6 00Z o1 oz
                                                                                          uko
                                                                              ol
                                                                                 in OR n3
                                                                                    t
               P




                                                                            ~0
               O i ccA




                                                                                                                                                  ov os o9 oz uw o6 00L or oz og or os o9 oz os os O
                                                                                                            w ol OZ O€ Or OS 05 Oz 08 06 pQJ 0%




               D stt O
                       c css sc




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                              Page 27 of 30


                                                                         Report No: CCISE190808701V01




                                                                                                                             wl uen WOesc 0d
                                                                                                sn d
                                                                                                  " oL Oc O€ Oor os oS oz
                e




                                                                              CS
                                                                               " ol Oc o€ Oor os os oz
                                          Eooo
                                          ce




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                                                                Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                      Page 28 of 30


c c I s                                                                  Report No: CCISE190808701V01


                                                                                          j
                                                                                          =d



                                                                                         P
                                                                                         [=]
                                                                                         eS
                                                                                         O




                                                                              e c
                                                                                        ho
                                                                                        o
                                                                                        m
                                                                                        o
                                                                                        L
                                                                                     «J
                                                                                     &




                                                                                    l e e Oe :
                                               PUAES
                                               PA e
                                               """iith




                                                                                    C
                                               (PEHTD
                                              ©000




                                                                          nllQ
               $Ob Oc aicaic sns ac)




                    08 O 09 OS Or O€f 02 04




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                        Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                        Page 29 of 30


CCGIS                                                                       Report No: CCISE190808701V01




                                              Lo                   :
                                               asecouon .   39 $1940—0
                                                            ECE




                 08 Oz 09 OS Oor o€f OZ 04


                                               ------ End of report——————




Shenzhen Zhongiian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1908087
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 30 of 30



Document Created: 2019-10-18 15:59:09
Document Modified: 2019-10-18 15:59:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC