                                                                                                Plot No.1
—   Test Laboratory: KTL
—   Model: PM60G174346E0C
—   Position: GSM850 RIGHT CHEEK TOUCH_190CH_1D N4313_NUMERIC
—   Test Date: 07/01/2014
—   Measured Liquid Temperature: 22.5 C, Ambient Temperature: 22.1 °C

Communication System: UID 0, GSM 850 (0); Communication System Band: Exported from older
format (data unavailable — please correct).; Frequency: 836.6 MHz;Communication System PAR: 9.191
dB; PMF: 2.88104
Medium parameters used (interpolated): f = 836.6 MHz; 0 = 0.89 $/m; &, = 41.478; p = 1000 kg/m®
Phantom section: Right Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

     e     Probe: ES3DV2 — SN3020; ConvF(6.39, 6.39, 6.39); Calibrated: 25.02.2014;
     e     Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
     e     Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
     +     Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QD000P4OCD; Serial: TP :xxxx
     e     DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Right/Touch/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.422 W/kg
Right/Touch/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 10.708 V/m; Power Drift = —0.09 dB
Peak SAR (extrapolated) = 0.497 W/kg
SAR(1 g) = 0.385 W/kg; SAR(10 g) = 0.294 W/kg
Maximum value of SAR (measured) = 0.423 W/kg




         —1.82



         —3.64



         —5.47



         —£.29



         —9.11
                  0 dB = 0.423 W/kg = —3.74 dBW/kg

nmmemmmmeeeeeereeeeeeeeeeeeeeneemmmmmnmmmmmmmmmen
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                            Tel: +82—31—500—0133
hittp://www.ktl.re.kr                                                                 Fax: +82—31—500—0149


    k‘t I taxteAye
          Korea Testing Laboratory                                                   14—030828—01—01

                                                                                           Plot No.2
—   Test Laboratory: KTL
—   Model: PM6O0G174346E0OC
—   Position: GSM850 BODY REAR 1.5cm_190CH_1D N4313_NUMERIC
—   Test Date: 07/03/2014
—   Measured Liquid Temperature: 22.7 °C, Ambient Temperature: 22.1 C

Communication System: UID 0, GSM 850 (0); Communication System Band: Exported from older
format (data unavailable — please correct).; Frequency: 836.6 MHz;Communication System PAR: 9.191
dB; PMF: 2.88104
Medium parameters used (interpolated): f = 836.6 MHz; 0 = 0.96 S/m; &, = 55.858; p = 1000 kg/m®
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

          Probe: ES3DV2 — SN3020; ConvF(6.17, 6.17, 6.17); Calibrated: 25.02.2014;
          Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
          Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
          Phantom: SAM with CRP v5.0(Right)2014_03_05; Type: QDOOOP40CD; Serial: TP :xxxx
          DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Body/Rear/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.523 W/kg
Body/Rear/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 23.555 V/m; Power Drift = —0.49 dB
Peak SAR (extrapolated) = 1.01 W/kg
SAR(1 g) = 0.535 W/kg; SAR(10 g) = 0.214 W/kg
Maximum value of SAR (measured) = 0.521 W/kg




       —2.31



       ~4.562



       —6.93



       —9.241



       11.55
                  0 dB = 0.523 W/kg = —2.81 dBW/kg
mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                       Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                            Fax: +82—31—500—0149


    k‘t I TsAblaA®e
          Korea Testing Latoratory                                                        14—030828—01—01

                                                                                                  Plot No.3
—   Test Laboratory: KTL
—   Model: PM60G174346E0C
—   Position: GSM1900 LEFT CHEEK TOUCH_661CH_1D N4313_NUMERIC
—   Test Date: 07/07/2014
— Measured Liquid Temperature: 22.3 °C, Ambient Temperature: 22.0 °C

Communication System: UID 0, DCS 1900 (0); Communication System Band: Exported from older
format (data unavailable — please correct).; Frequency: 1880 MHz;Communication System PAR: 9.191
dB; PMF: 2.88104
Medium parameters used: f = 1880 MHz; 0 = 1.45 S/m; s, = 39.74; p = 1000 kg/m3
Phantom section: Left Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

      e     Probe: ES3DV2 — SN3020; ConvF(4.85, 4.85, 4.85); Calibrated: 25.02.2014;
      e     Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
      e     Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
      +     Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QD000P4OCD; Serial: TP :xxxx
      e     DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Left/Touch/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.161 W/kg
Left/Touch/Zoom Scan (7x7x7) (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 4.437 V/m; Power Drift = 0.25 dB
Peak SAR (extrapolated) = 0.218 W/kg
SAR(1 g) = 0.145 W/kg; SAR(10 g) = 0.091 W/kg
Maximum value of SAR (measured) = 0.170 W/kg




          —2.90



          —5.80



          —8.71



          —11.61



          —14.51
                   0 dB = 0.170 W/kg = —7.70 dBW/kg

nmmemmmmeeeeeereeeeeeeeeeeeeeneemmmmmnmmmmmmmmmen
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                             Tel: +82—31—500—0133
hittp://www.ktl.re.kr                                                                  Fax: +82—31—500—0149


    k‘t I taxteAye
          Korea Testing Laboratory                                                      14—030828—01—01

                                                                                               Plot No.4
—   Test Laboratory: KTL
—   Model: PM6O0G174346E0OC
—   Position: GSM1900 BODY REAR 1.5¢m_661CH_2D N56O0x_NUMERIC
—   Test Date: 07/09/2014
—   Measured Liquid Temperature: 22.2 C, Ambient Temperature: 22.0 C

Communication System: UID 0, GPRS 1900 2tx (0); Communication System Band: Exported from older
format (data unavailable — please correct).; Frequency: 1880 MHz;Communication System PAR: 6.18
dB; PMF: 2.03704
Medium parameters used: f= 1880 MHz; o0 = 1.57 $/m; ; = 51.14; p = 1000 kg/m‘
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

          Probe: ES3DV2 — SN3020; ConvF(4.41, 4.41, 4.41); Calibrated: 25.02.2014;
          Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
          Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
          Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
          DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Body/Rear/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.285 W/kg
Body/Rear/Zoom Scan (7x7x7) (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.479 V/m; Power Drift = —0.36 dB
Peak SAR (extrapolated) = 0.365 W/kg
SAR(1 g) = 0.252 W/kg; SAR(10 g) = 0.166 W/kg
Maximum value of SAR (measured) = 0.291 W/kg




       —3.07



       —6.13



       —9.20



       —12.27



       —15.33
                  0 dB = 0.285 W/kg = —5.45 dBW/kg
mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                Fax: +82—31—500—0149


    k‘t I uaxelaiua
          Korea Testing Latoratory                                                        14—030828—01—01

                                                                                                 Plot No.5
—   Test Laboratory: KTL
—   Model: PM60G174346E0C
—   Position: WCDMA850 RIGHT CHEEK TOUCH_HIGH_1D N4313_NUMERIC
—   Test Date: 07/01/2014
— Measured Liquid Temperature: 22.5 C, Ambient Temperature: 22.0 °C

Communication System: UID 0, WCDMA 5 (0); Communication System Band: 4175; Frequency: 835
MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 835 MHz; 0 = 0.89 $/m; s, = 41.5; p = 1000 kg/m®
Phantom section: Right Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

      +     Probe: ES3DV2 — SN3020; ConvF(6.39, 6.39, 6.39); Calibrated: 25.02.2014;
      e     Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
      e     Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
      +     Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QD000P4OCD; Serial: TP :xxxx
      e     DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Right/Touch/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.474 W/kg
Right/Touch/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 9.994 V/m; Power Drift = —0.38 dB
Peak SAR (extrapolated) = 0.567 W/kg
SAR(1 g) = 0.435 W/kg; SAR(10 g) = 0.330 W/kg
Maximum value of SAR (measured) = 0.477 W/kg




          —1.87



          —3.75



          —5.62



          —7 49



          —9.37
                   0 dB = 0.477 W/kg = —8.21 dBW/kg

nmmemmmmeeeeeereeeeeeeeeeeeeeneemmmmmnmmmmmmmmmen
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                             Tel: +82—31—500—0133
hittp://www.ktl.re.kr                                                                  Fax: +82—31—500—0149


    k‘t I taxteAye
          Korea Testing Laboratory                                                   14—030828—01—01

                                                                                           Plot No.6
—   Test Laboratory: KTL
—   Model: PM6O0G174346E0OC
—   Position: WCDMA850 BODY REAR 1.5cm_4175CH_1D N4313_NUMERIC
—   Test Date: 07/03/2014
—   Measured Liquid Temperature: 22.7 °C, Ambient Temperature: 22.0 C

Communication System: UID 0, WCDMA 5 (0); Communication System Band: 4175; Frequency: 835
MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 835 MHz; 0 = 0.96 S/m; & = 55.87; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

          Probe: ES3DV2 — SN3020; ConvF(6.17, 6.17, 6.17); Calibrated: 25.02.2014;
          Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
          Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
          Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
          DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Body/Rear/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.574 W/kg
Body/Rear/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 24.184 V/m; Power Drift = —0.29 dB
Peak SAR (extrapolated) = 0.667 W/kg
SAR(1 g) = 0.529 W/kg; SAR(10 g) = 0.402 W/kg
Maximum value of SAR (measured) = 0.582 W/kg




       —2.44



       —4.89



       —£.33



       —9.77



       —12.21
                  0 dB = 0.574 W/kg = —2.41 dBW/kg


mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                       Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                            Fax: +82—31—500—0149


    k‘t I TsAblaA®e
          Korea Testing Latoratory                                                        14—030828—01—01

                                                                                                  Plot No.7
—   Test Laboratory: KTL
—   Model: PM60G174346E0C
—   Position: WCDMA1900 LEFT CHEEK TOUCH_9400CH_1D N4313_NUMERIC
—   Test Date: 07/07/2014
— Measured Liquid Temperature: 22.3 °C, Ambient Temperature: 22.0 °C

Communication System: UID 0, WCDMA 2 (0); Communication System Band: Exported from older
format (data unavailable — please correct).; Frequency: 1880 MHz;Communication System PAR: 0 dB;
PMF: 1
Medium parameters used: f = 1880 MHz; 0 = 1.45 S/m; s, = 39.74; p = 1000 kg/m3
Phantom section: Left Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

      e     Probe: ES3DV2 — SN3020; ConvF(4.85, 4.85, 4.85); Calibrated: 25.02.2014;
      e     Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
      e     Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
      +     Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QD000P4OCD; Serial: TP :xxxx
      e     DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Left/Touch 10/Area Scan (6x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.318 W/kg
Left/Touch 10/Zoom Scan (7x7x7) (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 6.808 V/m; Power Drift = —0.20 dB
Peak SAR (extrapolated) = 0.459 W/kg
SAR(1 g) = 0.304 W/kg; SAR(10 g) = 0.190 Wikg
Maximum value of SAR (measured) = 0.355 W/kg




          —2.04



          —5.67



          —8.51



          —11.34



          —14.18
                   0 dB = 0.355 W/kg = —4.50 dBW/kg

nmmemmmmeeeeeereeeeeeeeeeeeeeneemmmmmnmmmmmmmmmen
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                             Tel: +82—31—500—0133
hittp://www.ktl.re.kr                                                                  Fax: +82—31—500—0149


    k‘t I taxteAye
          Korea Testing Laboratory                                                      14—030828—01—01

                                                                                               Plot No.8
—   Test Laboratory: KTL
—   Model: PM6O0G174346E0OC
—   Position: WCDMA1900 BODY REAR 1.5cm_9400CH_2D N56Ox_QWERTY
—   Test Date: 07/09/2014
—   Measured Liquid Temperature: 22.2 C, Ambient Temperature: 22.0 C

Communication System: UID 0, WCDMA 2 (0); Communication System Band: Exported from older
format (data unavailable — please correct).; Frequency: 1880 MHz;Communication System PAR: 0 dB;
PMF: 1
Medium parameters used: f= 1880 MHz; o0 = 1.57 $/m; &, = 51.14; p = 1000 kg/m‘
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

          Probe: ES3DV2 — SN3020; ConvF(4.41, 4.41, 4.41); Calibrated: 25.02.2014;
          Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
          Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
          Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
          DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Body/Rear/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.520 W/kg
Body/Rear/Zoom Scan (7x7x7) (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 13.847 V/m; Power Drift = —0.13 dB
Peak SAR (extrapolated) = 0.650 W/kg
SAR(1 g) = 0.451 W/kg; SAR(10 g) = 0.301 W/kg




       —2.64



       —5.29



       —£.93



       10.57



       —13.22
                  0 dB = 0.520 W/kg = —2.84 dBW/kg

mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                Fax: +82—31—500—0149


 k‘t I TsAblaA®e
       Korea Testing Latoratory                                                         14—030828—01—01

                                                                                                Plot No.9
— Test Laboratory: KTL
— Model: PM60G174346E0C
— Position: 802.11b 2437 LEFT CHEEK TOUCH_6CH_2D N56Ox_QWERTY
— Test Date: 07/11/2014
— Measured Liquid Temperature: 22.6 °C, Ambient Temperature: 21.0 °C

Communication System: UID 0, WLAN (0); Communication System Band: Exported from older format
(data unavailable — please correct).; Frequency: 2437 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 2437 MHz; 0 = 1.823 $/m; s, = 37.59; p = 1000 kg/m®
Phantom section: Left Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

    +     Probe: ES3DV2 — SN3020; ConvF(4.18, 4.18, 4.18); Calibrated: 25.02.2014;
    e     Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
    e     Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
    +     Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QD000P4OCD; Serial: TP :xxxx
    e     DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Left/Touch/Area Scan (8x12x1); Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.284 W/kg
Left/Touch/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 8.154 V/m; Power Drift = —0.05 dB
Peak SAR (extrapolated) = 0.512 W/kg
SAR(1 g) = 0.224 W/kg; SAR(10 g) = 0.104 W/kg
Maximum value of SAR (measured) = 0.299 W/kg




        —6.91



        —13.82



        —20.73



        —27.64



        —34.55
                  0 dB = 0.299 W/kg = —5.24 dBW/kg

nmmemmmmeeeeeereeeeeeeeeeeeeeneemmmmmnmmmmmmmmmen
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
hittp://www.ktl.re.kr                                                                Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                      14—030828—01—01

                                                                                          Plot No.10
— Test Laboratory: KTL
— Model: PM6O0G174346E0OC
— Position: 802.11b 2437 BODY FRONT 1.5em_6CH_2D N56Ox_QWERTY
— Test Date: 07/14/2014
— Measured Liquid Temperature: 22.8 °C, Ambient Temperature: 23.0 C

Communication System: UID 0, WLAN (0); Communication System Band: Exported from older format
(data unavailable — please correct).; Frequency: 2437 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used (interpolated): f = 2437 MHz; 0 = 1.881 S/im; &; = 50.548; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

       Probe: ES3DV2 — SN3020; ConvF(3.78, 3.78, 3.78); Calibrated: 25.02.2014;
       Sensor—Surface: 3mm (Mechanical Surface Detection), z = 2.0, 32.0
       Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
       Phantom: SAM with CRP v5.0(Left)_2014_03_05; Type: QDOOOP4OCD; Serial: TP :xxxx
       DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Body/Front/Area Scan (7x10x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.0500 W/kg
Body/Front/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 3.151 V/m; Power Drift = —0.15 dB
Peak SAR (extrapolated) = 0.0750 W/kg
SAR(1 g) = 0.042 W/kg; SAR(10 g) = 0.024 W/kg
Maximum value of SAR (measured) = 0.0501 W/kg




     —2.41



     —4.81



     —1.22



     —9.63



     —12.04
               0 dB = 0.0500 W/kg = —18.01 dBW/kg

mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                        Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                             Fax: +82—31—500—0149


    k‘t I TsAblaA®e
          Korea Testing Latoratory                                                           14—030828—01—01

                                                                                                  Plot No.11
—   Test Laboratory: KTL
—   Model: PM60G174346E0C
—   Position: 802.11a 5240 LEFT TILT_48CH_2D N56Ox_QWERTY
—   Test Date: 07/16/2014
— Measured Liquid Temperature: 22.4 °C, Ambient Temperature: 23.0 °C

Communication System: UID 0, 5G FCC (0); Communication System Band: 5G FCC; Frequency: 5240
MHz;Communication System PAR: 0 dB; PMF: 1.12202e—005
Medium parameters used: f = 5240 MHz; 0 = 4.777 $/m; s, = 36.735; p = 1000 kg/m®
Phantom section: Left Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

      +        Probe: EX3DV4 — SN3905; ConvF(4.82, 4.82, 4.82); Calibrated: 26.02.2014;
      e        Sensor—Surface: 2mm (Mechanical Surface Detection), z = —3.0, 23.0
      e        Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
      +        Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QD000P4OCD; Serial: TP :xxxx
      e        DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Left/TILT/Area Scan (9x15x1); Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.405 W/kg
Left/TILT/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 4.620 V/m; Power Drift = 0.30 dB
Peak SAR (extrapolated) = 0.833 W/kg
SAR(1 g) = 0.246 W/kg; SAR(10 g) = 0.098 W/kg
Maximum value of SAR (measured) = 0.443 W/kg

          dB
          0



          —10.00



          —20.00



          —30.00


          —40.00                                                    ’

          —50.00
                      0 dB = 0.405 W/kg = —3.93 dBW/kg


nmmemmmmeeeeeereeeeeeeeeeeeeeneemmmmmnmmmmmmmmmen
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                                Tel: +82—31—500—0133
hittp://www.ktl.re.kr                                                                     Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                       14—030828—01—01

                                                                                           Plot No.12
— Test Laboratory: KTL
— Model: PM6O0G174346E0OC
— Position: 802.11a 5500 BODY REAR 1.5¢cm_100CH_2D N56O0x_NUMERIC
— Test Date: 07/21/2014
— Measured Liquid Temperature: 22.3 °C, Ambient Temperature: 23.0 C

Communication System: UID 0, 5G FCC (0); Communication System Band: 5G FCC; Frequency: 5500
MHz;Communication System PAR: 0 dB; PMF: 1.12202e—005
Medium parameters used: f = 5500 MHz; 0 = 5.78 $S/m; &, = 47.6; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

       Probe: EX3DV4 — SN3905; ConvF (3.74, 3.74, 3.74); Calibrated: 26.02.2014;
       Sensor—Surface: 2mm (Mechanical Surface Detection), z = —3.0, 23.0
       Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
       Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
       DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

Body/Rear/Area Scan (9x16x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 0.113 W/kg
Body/Rear/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 0.712 V/m; Power Drift = 1.56 dB
Peak SAR (extrapolated) = 0.300 W/kg
SAR(1 g) = 0.047 W/kg; SAR(10 g) = 0.013 W/kg




     —10.00



     —20.00



     —30.00



     —40.00



     —50.00
               0 dB = 0.113 W/kg = —9.47 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                         Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                              Fax: +82—31—500—0149


 k‘t I taxteAye Korea Testing Laboratory
                                                                                    14—030828—01—01
835 MHz Head — Verification DATA (D835V2 — 481)
— Test Date: 07/01/2014
— Measured Liquid Temperature: 22.5 C, Ambient Temperature: 22.1 C

Communication System: UID 0, CW (0); Communication System Band: D835 (835.0 MHz); Frequency:
835 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 835 MHz; 0 = 0.89 S/m; & = 41.5; p = 1000 kg/m®
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

   e     Probe: ES3DV2 — SN3020; ConvF(6.39, 6.39, 6.39); Calibrated: 25.02.2014;
             o Modulation Compensation:
         Sensor—Surface: 3mm (Mechanical Surface Detection), z = 1.0, 32.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

835MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/A¥rea Scan (7x8x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 2.90 W/kg
835MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Zoom Scan (7x7x7) (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 58.621 V/m; Power Drift = —0.00 dB
Peak SAR (extrapolated) = 3.69 W/kg
SAR(1 g) = 2.51 W/kg:; SAR(10 g) = 1.65 W/kg
Maximum value of SAR (measured) = 2.92 W/kg




       —3.79



       —1.58



       —11.36



       1515



       —18.94
                0 dB = 2.90 W/kg = 4.62 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                      Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                           Fax: +82—31—500—0149


 k‘t I taxteAye
              Korea Testing Laboratory
                                                                                   14—030828—01—01
835 MHz Body — Verification DATA (D835V2 — 481)
— Test Date: 07/03/2014
— Measured Liquid Temperature: 22.7 °C, Ambient Temperature: 22.1 C

Communication System: UID 0, CW (0); Communication System Band: D835 (835.0 MHz); Frequency:
835 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 835 MHz; 0 = 0.96 S/m; &, = 55.87; p = 1000 kg/m®
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

       Probe: ES3DV2 — SN3020; ConvF(6.17, 6.17, 6.17); Calibrated: 25.02.2014;
       Sensor—Surface: 3mm (Mechanical Surface Detection), z = 1.0, 32.0
       Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
       Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
       DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

835MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/A¥rea Scan (7x8x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 3.01 W/kg
835MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Zoom Scan (7x7x7) (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 57.277 V/m; Power Drift = —0.01 dB
Peak SAR (extrapolated) = 3.82 W/kg
SAR(1 g) = 2.6 W/kg; SAR(10 g) = 1.72 W/kg
Maximum value of SAR (measured) = 3.02 W/kg




     —~4.16



     —8.32



     —12.47



     —16.63



     —20.79
               0 dB = 3.01 W/kg = 4.78 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                      Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                           Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                         14—030828—01—01

1900 MHz Head— Verification DATA (D1900V2 — 5d038)
— Test Date: 07/07/2014
— Measured Liquid Temperature: 22.3 C, Ambient Temperature: 22.0 C

Communication System: UID 0, CW (0); Communication System Band: D1900 (1900.0 MHz);
Frequency: 1900 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 1900 MHz; 0 = 1.45 $/m; &, = 39.75; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

         Probe: ES3DV2 — SN3020; ConvF (4.85, 4.85, 4.85); Calibrated: 25.02.2014;
         Sensor—Surface: 3mm (Mechanical Surface Detection), z = 1.0, 32.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

1900MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Area Scan (7x8x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 12.3 W/kg
1900MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Zoom Scan (7x7x7) (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 98.124 V/m; Power Drift = —0.01 dB
Peak SAR (extrapolated) = 18.9 W/kg
SAR(1 g) = 10.5 W/kg:; SAR(10 g) = 5.56 W/kg
Maximum value of SAR (measured) = 13.3 W/kg

    dB
     U



     —6.42



     —12.84



     —19.26



     —25.68



     —32.10
                0 dB = 12.3 W/kg = 10.89 dBW/kg




mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                        14—030828—01—01

1900 MHz Body— Verification DATA (D1900V2 — 5d038)
— Test Date: 07/09/2014
— Measured Liquid Temperature: 22.2 C, Ambient Temperature: 22.0 C

Communication System: UID 0, CW (0); Communication System Band: D1900 (1900.0 MHz);
Frequency: 1900 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 1900 MHz; 0 = 1.57 $/m; &, = 51.05; p = 1000 kg/m‘
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

         Probe: ES3DV2 — SN3020; ConvF(4.41, 4.41, 4.41); Calibrated: 25.02.2014;
         Sensor—Surface: 3mm (Mechanical Surface Detection), z = 1.0, 32.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

1900MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Area Scan (7x8x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 12.9 W/kg
1900MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Zoom Scan (7x7x7) (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 96.271 V/m; Power Drift = —0.03 dB
Peak SAR (extrapolated) = 18.6 W/kg
SAR(1 g) = 10.6 W/kg:; SAR(10 g) = 5.63 W/kg
Maximum value of SAR (measured) = 13.4 W/kg

    dB
     U



     —6.79



     —13.58



     —20.37



     —27.16



     —33.95
                0 dB = 12.9 W/kg = 11.10 dBW/kg




mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                          Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                               Fax: +82—31—500—0149


 k‘t I taxteAyeKorea Testing Laboratory
                                                                                       14—030828—01—01
2450 MHz Head— Verification DATA (D2450V2— 746)
— Test Date: 07/11/2014
— Measured Liquid Temperature: 22.6 °C, Ambient Temperature: 22.0 C

Communication System: UID 0, CW (0); Communication System Band: D2450 (2450.0 MHz);
Frequency: 2450 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 2450 MHz; o0 = 1.84 S/m; &, = 37.547; p = 1000 kg/m®
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

         Probe: ES3DV2 — SN3020; ConvF(4.18, 4.18, 4.18); Calibrated: 25.02.2014;
         Sensor—Surface: 3mm (Mechanical Surface Detection), z = 1.0, 32.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

2450MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Area Scan (7x8x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 17.1 W/kg
2450MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Z0om Scan (7x7x7) (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 101.9 V/m; Power Drift = —0.01 dB
Peak SAR (extrapolated) = 28.2 W/kg
SAR(1 g) = 13.7 Wikg:; SAR(10 g) = 6.39 W/kg
Maximum value of SAR (measured) = 18.0 W/kg

    dB
     U



     —6.41



     —12.83



     —19.24



     —25.65



     —32.06
                0 dB = 17.1 W/kg = 12.32 dBW/kg




mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                          Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                               Fax: +82—31—500—0149


 k‘t I taxteAye    Korea Testing Laboratory
                                                                                          14—030828—01—01
2450 MHz Body— Verification DATA (D2450V2— 746)
— Test Date: 07/14/2014
— Measured Liquid Temperature: 22.8 °C, Ambient Temperature: 23.0 C

Communication System: UID 0, CW (0); Communication System Band: D2450 (2450.0 MHz);
Frequency: 2450 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 2450 MHz; o0 = 1.897 S/m; s, = 50.545; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

   e        Probe: ES3DV2 — SN3020; ConvF(3.78, 3.78, 3.78); Calibrated: 25.02.2014;
               o Modulation Compensation:
            Sensor—Surface: 3mm (Mechanical Surface Detection), z = 1.0, 32.0
            Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
            Phantom: SAM with CRP v5.0(Left)_2014_03_05; Type: QDOOOP4OCD; Serial: TP :xxxx
            DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

2450MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Area Scan (7x8x1): Measurement grid:
dx=15mm, dy=15mm
Maximum value of SAR (measured) = 16.0 W/kg
2450MHz/d=10mm, Pin=xx mW, dist=3.0mm (ES—Probe) 2/Z0om Scan (7x7x7) (5x5x7)/Cube 0:
Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 96.914 V/m; Power Drift = —0.01 dB
Peak SAR (extrapolated) = 27.3 W/kg
SAR(1 g) = 13.1 W/kg:; SAR(10 g) = 6.12 W/kg
Maximum value of SAR (measured) = 17.2 W/kg

       dB
        U



       —6.42



       —12.84



       —19.27



       —25.69



       —32.11
                   0 dB = 16.0 W/kg = 12.03 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                             Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                  Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                         14—030828—01—01

5200 MHz Head— Verification DATA (D5GHzV2— 1147)
— Test Date: 07/16/2014
— Measured Liquid Temperature: 22.4 °C, Ambient Temperature: 23.0 C

Communication System: UID 0, CW; Communication System Band: D5GHz (5000.0 — 6000.0 MHz);
Frequency: 5200 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 5200 MHz; 0 = 4.727 S/m; &, = 36.596; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

         Probe: EX3DV4 — SN3905; ConvF (4.82, 4.82, 4.82); Calibrated: 26.02.2014;
         Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, £=5200
MHz/Area Scan (10x10x1);: Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 13.6 W/kg
System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5200
MHz/Zoom Scan (4x4x1.4mm, graded), dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 69.960 V/m; Power Drift = —0.02 dB
Peak SAR (extrapolated) = 32.7 W/kg
SAR(1 g) = 8.12 W/kg:; SAR(10 g) = 2.37 W/kg
Maximum value of SAR (measured) = 18.8 W/kg

    dB
     U



     —6.57



     —13.14



     —19.71



     —26.28



     —32.85
                0 dB = 13.6 W/kg = 11.34 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                         14—030828—01—01

5500 MHz Head— Verification DATA (D5GHzV2— 1147)
— Test Date: 07/18/2014
— Measured Liquid Temperature: 22.2 °C, Ambient Temperature: 23.0 C

Communication System: UID 0, CW; Communication System Band: D5GHz (5000.0 — 6000.0 MHz); Frequency:
5500 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 5500 MHz; 0 = 5.053 S/m; s, = 35.827; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

          Probe: EX3DV4 — SN3905; ConvF(4.52, 4.52, 4.52); Calibrated: 26.02.2014;
          Sensor—Surface: 1.4mm (Mechanical Surface Detection), z2 = 1.0, 25.0
          Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
          Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP40CD; Serial: TP :xxxx
          DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5500 MHz/Area
Scan (10x10x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 15.2 W/kg
System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5500 MHz/Zoom
Scan (4x4x1.4mm, graded), dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 73.160 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 37.6 W/kg
SAR(1 g) = 8.96 W/kg; SAR(10 g) = 2.56 W/kg
Maximum value of SAR (measured) = 21.2 W/kg


     dB
      U



     —£.39



     —14.78



     —22.17



     —29.56



     —36.95
                  0 dB = 15.2 Wi/kg = 11.83 dBW/kg




mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                         14—030828—01—01

5500 MHz Body— Verification DATA (D5GHzV2— 1147)
— Test Date: 07/21/2014
— Measured Liquid Temperature: 22.3 °C, Ambient Temperature: 23.0 C

Communication System: UID 0, CW; Communication System Band: D5GHz (5000.0 — 6000.0 MHz);
Frequency: 5500 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 5500 MHz; 0 = 5.78 $S/m; &, = 47.6; p = 1000 kg/m*
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

         Probe: EX3DV4 — SN3905; ConvF (3.74, 3.74, 3.74); Calibrated: 26.02.2014;
         Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5500
MHz/Area Scan (10x10x1);: Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 13.3 W/kg
System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5500
MHz/Zoom Scan (4x4x1.4mm, graded), dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 68.829 V/m; Power Drift = —0.07 dB
Peak SAR (extrapolated) = 34.2 W/kg
SAR(1 g) = 8.5 W/kg; SAR(10 g) = 2.39 W/kg
Maximum value of SAR (measured) = 19.6 W/kg

    dB
     U



     —£.38



     —14.75



     —22.13



     —29.50



     —36.88
                0 dB = 13.3 W/kg = 11.23 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                           Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                                Fax: +82—31—500—0149


 k‘t I taxteAye
       Korea Testing Laboratory                                                     14—030828—01—01

5800 MHz Head— Verification DATA (D5GHzV2— 1147)
— Test Date: 07/23/2014
— Measured Liquid Temperature: 22.5 C, Ambient Temperature: 23.0 C

Communication System: UID 0, CW; Communication System Band: D5GHz (5000.0 — 6000.0 MHz);
Frequency: 5800 MHz;Communication System PAR: 0 dB; PMF: 1
Medium parameters used: f = 5800 MHz; 0 = 5.464 $/m; &, = 35.218; p = 1000 kg/m®
Phantom section: Flat Section
Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2007)

DASY Configuration:

         Probe: EX3DV4 — SN3905; ConvF(5.2, 5.2, 5.2); Calibrated: 26.02.2014;
         Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
         Electronics: DAE4 Sn1422; Calibrated: 13.01.2014
         Phantom: SAM with CRP v5.0(Right)_2014_03_05; Type: QDOOOP4OCD; Serial: TP:xxxx
         DASY52 52.8.7(1137); SEMCAD X 14.6.10(7164)

System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5800
MHz/Area Scan (10x10x1);: Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 14.6 W/kg
System Performance Check with D5GHzV2 Dipole (graded grid)/d=10mm, Pin=100mW, f=5800
MHz/Zoom Scan (4x4x1.4mm, graded), dist=1.4mm (8x8x7)/Cube 0: Measurement grid: dx=4mm,
dy=4mm, dz=1.4mm
Reference Value = 68.354 V/m; Power Drift = —0.03 dB
Peak SAR (extrapolated) = 37.9 W/kg
SAR(1 g) = 8.23 W/kg:; SAR(10 g) = 2.34 W/kg
Maximum value of SAR (measured) = 20.3 W/kg

    dB
     U



     —10.00



     —20.00



     —30.00



     —40.00



     —50.00
                0 dB = 14.6 W/kg = 11.65 dBW/kg



mm
723 Haean—ro, Sa—dong, Sangnok—gu, Ansan—si, 426—910 Korea                       Tel: +82—31—500—0133
http:://www.ktl.re.kr                                                            Fax: +82—31—500—0149



Document Created: 2014-09-26 11:07:59
Document Modified: 2014-09-26 11:07:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC