Test Report 15B main

FCC ID: V2TSDHTAG3NFC

Test Report

Download: PDF
FCCID_4508966

                                            TEST REPORT
                                          No.: 17-1-0133808T05a-C1


                                                         According to:
                                                  FCC Regulations Part 15B
                                                  Part 15.109 (Class B limits)

                                                       ISED-Regulations
                                                        ICES-003, Issue 6




                                                                 for

                                    WITTE - Velbert GmbH & Co. KG


                                            DAG SDH TAG3 NFC
                                         Outer Door Handle with NFC

                                                FCC ID: V2T-SDHTAG3NFC




                                            Laboratory Accreditation and Listings




                                                   Accredited EMC-Test Laboratory




                                      accredited according to DIN EN ISO/IEC 17025

                                                       CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                       Page 1 of 15
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 17-1-0133808T05a-C1, Page 2 of 15


Table of contents
1. SUMMARY OF TEST RESULTS                                                                       3
  1.1. TEST OVERVIEW ACCORDING FCC PART 15B                                                      3
2. ADMINISTRATIVE DATA                                                                           4
  2.1. Identification of the testing laboratory                                                  4
  2.2. Test location                                                                             4
  2.3. Organizational items                                                                      4
  2.4. Applicant’s details                                                                       4
  2.5. Manufacturer’s details                                                                    4
3. EQUIPMENT UNDER TEST (EUT)                                                                    5
  3.1. EUT: Type, S/N etc. and short descriptions used in this test report                       5
  3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions                           5
  3.3. EUT set-ups                                                                               5
  3.4. EUT operating modes                                                                       5
  3.5. Additional declaration and description of EUT                                             6
  3.6. Configuration of cables used for testing                                                  6
4. DESCRIPTION OF TEST SYSTEM SET-UP’S                                                           7
  4.1. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz                7
5. MEASUREMENTS                                                                                  8
  5.1. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz                         8
  5.2. Measurement uncertainties                                                                 9
6. ABBREVIATIONS USED IN THIS REPORT                                                            10
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES                               10
8. INSTRUMENTS AND ANCILLARY                                                                    11
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY)                                                    15



Table of annex                                                                          Total pages
Annex 1: Measurement diagram, separate document CETECOM-TR17-1-0133808T05a-A1-C1                 4
Annex 2: Internal photographs, separate document to be issue by applicant              NOT ISSUED
Annex 3: External photographs, separate document CETECOM-TR17-1-0133808T05a-A3-C1                6
Annex 4: Test set-up photographs, separate document CETECOM-TR17-1-0133808T05a-A4-C1             3

The listed attachments are an integral part of this report.




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 3 of 15



1. Summary of test results

The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveillance tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a digital device with no support of
radiofrequency technologies. A typical operating mode (one or more) as used in the real usage was tested or a
special test program simulating this was used. Pls. see chapter Operating-Mode for more details.

Following tests have been performed to show compliance with applicable standards as shown in table below:


1.1. TEST OVERVIEW ACCORDING FCC PART 15B

    No. of                                                              References & Limits                                         EUT
                                                                                                                       EUT
   Diagram              Test case               Port                                                                                 op-          Result
                                                                                                                      set-up
    group                                                FCC Standard   ISED Standard           Test limit                          mode
                                                                                               FCC 15.109
                       Receiver                                                               class B limits
                                   Cabinet +
                        radiated                                        ICES-003, Issue
        3                        Interconnec               §15.109                                                       1             1          Passed
                       emissions                                              6           ICES-003, Issue 6,
                                  ting cables
                    30 MHz-1 GHz                                                          Chapter 6.2.1, Table
                                                                                                   5


Test report CETECOM-TR17-1-0133808T05a-C1 replace test report CETECOM-TR17-1-0133808T05a, issued 2019-10-18.
The replaced test report gets invalid herewith.



                          Digital signiert von:                                                                                CN = Hicham Laayouni
                                                                                                                               email = hicham.
                          Christian Lorenz
                                                                                                                               laayouni@cetecom.com
                          Datum: 2019.11.07                                                                                     C = DE O = CETECOM
                          12:19:38 +01'00'                                                                                     2019.11.07 11:03:11 +
                                                                                                                               01'00'
......................................................                                                 ....................................................
Dipl.-Ing. Christian Lorenz                                                                                                  B.Sc. H. Laayouni
Responsible for test section                                                                                     Responsible for test report




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 4 of 15


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Volker Wittmann
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report and
project leader:                                                       B.Sc. H. Laayouni
Receipt of EUT:                                                       2019-10-09
Date(s) of test:                                                      2019-10-10
Date of report:                                                       2019-11-07
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     WITTE - Velbert GmbH & Co. KG
Address:                                                              Höferstraße 3-15
                                                                      42551, Velbert
                                                                      Germany

Contact person:                                                       Mr. Kay Lackmann

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see applicant´s details

Address:                                                              please see applicant´s details




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 5 of 15


3. Equipment under test (EUT)
3.1. EUT: Type, S/N etc. and short descriptions used in this test report
 Short
                                                                        S/N               HW               SW
 descrip-            EUT                       Type
                                                                   serial number        hardware         software
 tion*)
                                                                                         status           status
 EUT A        DAG SDH TAG3             Outer Door Handle
                                                                    191004-03            19.45.00        19.28.11
   S45            NFC                      with NFC

*) EUT short description is used to simplify the identification of the EUT in this test report.



3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

    AE
                                                                        S/N               HW              SW
   short     Auxiliary Equipment               Type
                                                                   serial number       hardware      software status
 descrip-
                                                                                         status
  tion *)
  AE 1              Shield                       --                190514_023                  --           --
                BearingBracket                                    Homologation
  AE 2                                    DH Electronic                                   D5-2            D5-2
                  Electronic                                       DAG SDH
                                        Banana to Banana
  AE 3           Power Cable                                             --                    --           --
                                             Cable
                                           Yuasa (12V,
  AE 4              Battery                                         1807303L                   --           --
                                          4AH)/NP4-12S
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.3. EUT set-ups

 EUT set-up
                       Combination of EUT and AE                                      Remarks
   no.*)

    set. 1          EUT A + AE1 + AE2 + AE3 + AE4                                         --
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.


3.4. EUT operating modes

    EUT
                  Description of
  operating                                                      Additional information
                 operating modes
 mode no.*)
                                         EUT Powered on and processor running
    op. 1           Ping-Mode
                                         Without NFC continuous fire.
*) EUT operating mode no. is used to simplify the test report.




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 6 of 15

3.5. Additional declaration and description of EUT
(Applicant's declaration,  = not selected,  = selected)
 EUT A                                                       table-top            typical use          typical operating
                                                                                                        cycle of EUT.
                                                             floor-              portable use          < 0,5 sec.
                                                            standing              fixed use             :
                                                             wall-mounted  vehicular use
                                                             not defined
 Place of use                                                Residential, commercial and light industry
                                                             Industrial environment
                                                             vehicular use
 Highest internal frequency generated by EUT                 less than 108 MHz          -> up to 1 GHz
 and required upper frequency of radiated                    108 MHz - 500 MHz -> up to 2 GHz
 disturbance measurement                                     500 MHz - 1 GHz            -> up to 5 or 6 GHz
 Power line:                                                EUT-grounding:
                                                                                             (in case of deviation during tests the
  DC  12V                                                  none                              single details are described on
                                                             with power supply                            chapter 4)
                                                             additional:
 Other Ports                                                  possible total cable length       shielding          connected
                                                                                                                    during test
 (description of interconnecting cables)
                               Connector
 1. Power Cable                Banana              < 3m         > 3m              screened                          yes
                                                   : other                         unscreened                        no
 Does EUT contain devices susceptible to magnetic fields, e.g. Hall elements, electrodynamics                          yes
 microphones, etc.?                                                                                                    no
                                                                                                                       yes
 Is mounting position / usual operating position defined?
                                                                                                                       no


3.6. Configuration of cables used for testing
   Cable
                                                                             S/N                HW                Cable length
  number                Item                         Type
                                                                        serial number      hardware status
 Cable 1           Power Cable               Banana to Banana                 --                   --                100cm
                                                  Cable




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 7 of 15


4. Description of test system set-up’s
      4.1. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz


 Specification:              ANSI C63.4-2014 chapter 8.2.3, ANSI C63.10-2013 chapter 6.5

 General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                             regulatory commissions.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                             turntable. By rotating the turntable (range 0° to    position, etc. either on 10m OATS or 3m semi-
                             360°, step 90°) and the EUT itself either on 3-      anechoic room.
                             orthogonal axis (portable equipment) or 2-
                             orthogonal axis (defined operational position of     First a frequency zoom around the critical frequency
                             EUT) the emission spectrum and it’s                  is done to locate the frequency more precisely. After
                             characteristics was recorded with an EMI-            this step, for all identified critical frequencies, the
                             receiver, broadband antenna and software.            maximum peak was determined.

                             Measurement antenna: horizontal and vertical,        Following parameters were varied: the turntable
                             heights: 1,0 m and 1,82 m as worst-case              angle continuously in the range 0 to 360 degree, the
                             determined by an exploratory emission                EUT itself either over 3-orthogonal axis (not
                             measurements. The results are documented in a        defined usage position) or 2-orthogonal axis
                             diagram. Critical frequencies (low margin to         (defined usage position). The measurement antenna
                             limit) are saved within a table for further          height between 1 m and 4 m.
                             investigations. If various operating modes are
                             supported, further investigations are made to find   On the determined worst-case position, a final
                             the worst-case of them. Also the interconnection     measurement with necessary bandwidth and
                             cables and equipment position were varied in         detector according standard has been carried out.
                             order to maximize the emissions.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                       CL = Cable loss
                             M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA = Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 8 of 15


5. Measurements

5.1. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.1.1. Test location and equipment
 test location       CETECOM Essen (Chapter. 2.2.1)          Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
 test site           441 EMI SAR  487 SAR NSA
 receiver            377 ESCS30       001 ESVS 30           489   ESU 40        620 ESU 26
 spectr. analys.     584 FSU          120 FSEM              264   FSEK
 antenna             574 BTA-L        133 EMCO3115          302   BBHA9170      289 CBL 6141         030 HFH-Z2         477 GPS
 signalling          392 MT8820A  371 CBT32                 547   CMU           594 CMW
 DC power            Battery Powered  457 EA 3013A          459   EA 2032-50    268 EA- 3050         494 AG6632A  498 NGPE

5.1.2. Requirements/Limits
                       FCC
                                                 Part 15 Subpart B, §15.109, class B
                                                 Part 15 Subpart C, §15.209 @ frequencies defined in §15.205

                                                 RSS-Gen., Issue 5, Chapter 8.9, Table 5+6+7 (licence-exempt radio apparatus)
                                                 RSS-Gen., Issue 5, Chapter 7.3, Table 3 (receiver)
                    ISED (IC)
                                                 ICES-003, Issue 6, Table 4(class A)/Table 5(Class B)
                                                 RSS-247, Issue 2, Chapter 5.5  RSS-247, Issue 2, Chapter 6.2

                                                 C63.4-2014
                      ANSI
                                                 C63.10-2013
                                                                         Radiated emissions limits, 3 meters
                       Frequency [MHz]
                                                           QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                            30 - 88                              100                                         40.0
     Limit
                           88 - 216                              150                                         43.5
                          216 - 960                              200                                         46.0
                          above 960                              500                                         54.0


5.1.3. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m hight                   floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
 General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”

5.1.4. MEASUREMENT RESULTS
The results are presented below in summary form only. For more information please consult the diagrams
included in annex 1.


   Dia-                               Set-                 OP-                                                Used detector           Result
                   Frequency
   gram                                up                  mode                      Remark
                     range
    no.                               no.                   no.
                                                                                                             PK      AV    QP
               30 MHz – 1
   3.01                                  1                   1               EUT position standing                                 passed
                  GHz
               30 MHz – 1
   3.02                                  1                   1                EUT position laying                                  passed
                  GHz
Remark: see diagrams in annex 1 for more details




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 9 of 15

5.2. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
     RF-Measurement           Reference         Frequency range                                                      Remarks
                                                                           confidence level of 95%
 Conducted emissions                     9 kHz - 150 kHz           4.0 dB
                            CISPR 16-2-1                                                                                -
 (U CISPR)                               150 kHz - 30 MHz          3.6 dB
 Radiated emissions                      30 MHz - 1 GHz            4.2 dB
                            CISPR 16-2-3                                                                             E-Field
 Enclosure                               1 GHz - 18 GHz            5.1 dB
 Disturbance power          CISPR 16-2-2 30 MHz - 300 MHz          -                                                    -
                                                                                                                Substitution
 Power Output radiated               -     30 MHz - 4 GHz          3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                           Set-up No.                            BT1     W1     W2         --
                                                                    C1     C2
 Power Output conducted              -     9 kHz - 12.75 GHz       N/A 0.60       0.7   0.25   N/A         --           -
                                           12.75 - 26.5GHz         N/A 0.82        --   N/A    N/A         --
 Conducted emissions                 -     9 kHz - 2.8 GHz         0.70 N/A      0.70   N/A    0.69        --    N/A - not
 on RF-port                                2.8 GHz - 12.75GHz      1.48 N/A      1.51   N/A    1.43        --    applicable
                                           12.75 GHz - 18GHz       1.81 N/A      1.83   N/A    1.77        --
                                           18 GHz - 26.5GHz        1.83 N/A      1.85   N/A    1.79        --
 Power density                       -     1 – 2.8GHz              1.40 dB                                      --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
 Occupied bandwidth                  -     9 kHz - 4 GHz                                                        error
                                                                   1.0 dB                                       Power
                                     -                             0.1272 ppm (Delta Marker)                    Frequency
 Emission bandwidth                        9 kHz - 4 GHz                                                        error
                                     -                             See above: 0.70 dB                           Power
 Frequency stability                 -     9 kHz - 20 GHz          0.0636 ppm                                         -
                                           150 kHz - 30 MHz        5.0 dB                                       Magnetic
 Radiated emissions                        30 MHz - 1 GHz          4.2 dB                                       field
                                     -
 Enclosure                                 1 GHz - 20 GHz          3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 10 of 15




6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropic radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 ISED                    Innovation, Science and Economic Development
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Documents from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         FCC, Federal Communications
      (MRA US-EU
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)                             Commission
          0003)
 348                 Mains Ports Conducted Interference Measurements                          Laboratory Division, USA
 348                 Telecommunication Ports Conducted Interference Measurem.
 337        --       Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                              ISED, Industry Canada
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              Certification and Engineering
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R- 4452     Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550    G- 20013     Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348    C- 20009     Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348    T- 20006     Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 11 of 15


8. Instruments and Ancillary

The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
Ref.-No.




                         Equipment                        Type             Serial-No.        Version of Firmware or Software during the test


012        Signal Generator (EMS-cond.)          SMY 01             839069/027          Firm.= V 2.02
013        Power Meter (EMS cond.)               NRVD               839111/003          Firm.= V 1.51
017        Digital Radiocommunication Tester     CMD 60 M           844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
           RT Harmonics Analyzer dig.
119                                              B10                G60547              Firm.= V 3.1DHG
           Flickermeter
261        Thermal Power Sensor                  NRV-Z55            825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262        Power Meter                           NRV-S              825770/0010         Firm.= 2.6
                                                                                        UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295        Racal Digital Radio Test Set          6103               1572
                                                                                        SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                        R&S Test Firmware =3.53 /3.54 (current Testsoftw. f. all
298        Univ. Radio Communication Tester      CMU 200            832221/091
                                                                                        band used
323        Digital Radiocommunication Tester     CMD 55             825878/0034         Firm.= 3.52 .22.01.99
                                                 System EMS
335        CTC-EMS-Conducted                                        -                   EMC 32 V 8.52
                                                 Conducted
340        Digital Radiocommunication Tester     CMD 55             849709/037          Firm.= 3.52 .22.01.99
366        Ultra Compact Simulator               UCS 500 M4         V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371        Bluetooth Tester                      CBT32              100153              CBT V5,30+ SW-Option K55, K57
377        EMI Test Receiver                     ESCS 30            100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378        Broadband RF Field Monitor            RadiSense III      03D00013SNO-08      Firm.= V.03D13
389        Digital Multimeter                    Keithley 2000      0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                        Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392        Radio Communication Tester            MT8820A            6K00000788
                                                                                        GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                        R&S Test Firmware Base=5.14, Mess-Software=
436        Univ. Radio Communication Tester      CMU 200            103083
                                                                                        GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
                                                 System EMI field
441        CTC-SAR-EMI Cable Loss                                   -                   EMC 32 Version 8.52
                                                 (SAR)
                                                 System EMS field
442        CTC-SAR-EMS                                              -                   EMC 32 Version 8.40
                                                 (SAR)
                                                 System CTC-FAR-
443        CTC-FAR-EMI-RSE                                          -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                 EMI-RSE
                                                 System-EMS-Field
444        CTC-FAR-EMS field                                        -                   EMC 32 Version 9.15.00
                                                 (FAR)
                                                                                        R&S Test Firmware Base=5.14, GSM=5.14
460        Univ. Radio Communication Tester      CMU 200            108901
                                                                                        WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489        EMI Test Receiver                     ESU40              1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491        ESD Simulator dito                    ESD dito           dito307022          V 2.30
524        Voltage Drop Simulator                VDS 200            0196-16             Software Nr: 000037 Version V4.20a01
526        Burst Generator                       EFT 200 A          0496-06             Software Nr. 000034 Version V2.32
527        Micro Pulse Generator                 MPG 200 B          0496-05             Software-Nr. 000030 Version V2.43
528        Load Dump Simulator                   LD 200B            0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                        R&S Test Firmware Base=5.14, GSM=5.14
546        Univ. Radio Communication Tester      CMU 200            106436
                                                                                        WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                        R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547        Univ. Radio Communication Tester      CMU 200            835390/014
                                                                                        f. all band used, GSM = 5.14 WCDMA: = 5.14
584        Spectrum Analyzer                     FSU 8              100248              2.82_SP3
                                                                                        R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597        Univ. Radio Communication Tester      CMU 200            100347
                                                                                        not installed, Mainboard= µP1=V.850
607        Signal Generator                      SMR 20             832033/011          V1.25
620        EMI Test Receiver                     ESU 26             100362              4.43_SP3
642        Wideband Radio Communication Tester   CMW 500            126089              Setup V03.26, Test programm component V03.02.20
670        Univ. Radio Communication Tester      CMU 200            106833              µP1 =V8.50, Firmware = V.20
689        Vector Signal Generator               SMU200             100970              02.20.360.142
                                                                                        CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692        Bluetooth Tester                      CBT 32             100236
                                                                                        RF)
699        Audio Analyzer                        UPL16              833494/005          3.06




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 12 of 15



8.1.2. Single instruments and test systems
Ref.-No.




                                                                                                                    calibration
                                                                                                                    Interval of



                                                                                                                                  Remark
                         Equipment                           Type              Serial-No.       Manufacturer                                  Cal
                                                                                                                                              due

005        AC - LISN (50 Ohm/50µH, test site 1)   ESH2-Z5                  861741/005       Rohde & Schwarz         12 M          -        23.05.2020
007        Single-Line V-Network (50 Ohm/5µH)     ESH3-Z6                  892563/002       Rohde & Schwarz         12 M          -        23.05.2020
009        Power Meter (EMS-radiated)             NRV                      863056/017       Rohde & Schwarz         24 M          -        23.05.2021
016        Line Impedance Simulating Network      Op. 24-D                 B6366            Spitzenberger+Spies     36 M          -        22.05.2022
                                                                                                                    36/12
020        Horn Antenna 18 GHz (Subst 1)          3115                     9107-3699        EMCO                                  -        31.07.2021
                                                                                                                    M
021        Loop Antenna (H-Field)                 6502                     9206-2770        EMCO                    36 M          -        30.05.2021
033        RF-current probe (100kHz-30MHz)        ESH2-Z1                  879581/18        Rohde & Schwarz         24 M          -        23.05.2021
057        relay-switch-unit (EMS system)         RSU                      494440/002       Rohde & Schwarz         pre-m         1a
060        power amplifier (DC-2kHz)              PAS 5000                 B6363            Spitzenberger+Spies     -             3
                                                  WRCT 1900/2200-5/40-
066        notch filter (WCDMA; FDD1)                                      5                Wainwright GmbH         12 M          1g       16.11.2019
                                                  10EEK
086        DC - power supply, 0 -10 A             LNG 50-10                -                Heinzinger Electronic   pre-m         2
087        DC - power supply, 0 -5 A              EA-3013 S                -                Elektro Automatik       pre-m         2
091        USB-LWL-Converter                      OLS-1                    007/2006         Ing. Büro Scheiba       -             4
099        passive voltage probe                  ESH2-Z3                  299.7810.52      Rohde & Schwarz         36 M          -        30.05.2021
100        passive voltage probe                  Probe TK 9416            without          Schwarzbeck             36 M          -        30.05.2021
110        USB-LWL-Converter                      OLS-1                    -                Ing. Büro Scheiba       -             4
           RT Harmonics Analyzer dig.
119                                               B10                      G60547           BOCONSULT               36 M          -        22.05.2022
           Flickermeter
133        horn antenna 18 GHz (Meas 1)           3115                     9012-3629        EMCO                    36 M          1c       10.03.2020
134        horn antenna 18 GHz (Subst 2)          3115                     9005-3414        EMCO                    36 M          -        10.03.2020
248        attenuator                             SMA 6dB 2W               -                Radiall                 pre-m         2
249        attenuator                             SMA 10dB 10W             -                Radiall                 pre-m         2
252        attenuator                             N 6dB 12W                -                Radiall                 pre-m         2
256        attenuator                             SMA 3dB 2W               -                Radiall                 pre-m         2
257        hybrid                                 4031C                    04491            Narda                   pre-m         2
260        hybrid coupler                         4032C                    11342            Narda                   pre-m         2
261        Thermal Power Sensor                   NRV-Z55                  825083/0008      Rohde & Schwarz         24 M          -        30.05.2020
262        Power Meter                            NRV-S                    825770/0010      Rohde & Schwarz         24 M          -        30.05.2020
265        peak power sensor                      NRV-Z33, Model 04        840414/009       Rohde & Schwarz         24 M          -        30.05.2020
266        Peak Power Sensor                      NRV-Z31, Model 04        843383/016       Rohde & Schwarz         24 M          -        30.05.2020
267        notch filter GSM 850                   WRCA 800/960-6EEK        9                Wainwright GmbH         pre-m         2
270        termination                            1418 N                   BB6935           Weinschel               pre-m         2
271        termination                            1418 N                   BE6384           Weinschel               pre-m         2
272        attenuator (20 dB) 50 W                Model 47                 BF6239           Weinschel               pre-m         2
273        attenuator (10 dB) 100 W               Model 48                 BF9229           Weinschel               pre-m         2
274        attenuator (10 dB) 50 W                Model 47 (10 dB) 50 W    BG0321           Weinschel               pre-m         2
275        DC-Block                               Model 7003 (N)           C5129            Weinschel               pre-m         2
276        DC-Block                               Model 7006 (SMA)         C7061            Weinschel               pre-m         2
279        power divider                          1515 (SMA)               LH855            Weinschel               pre-m         2
                                                  AMF-2D-100M4G-35-
287        pre-amplifier 25MHz - 4GHz                                      379418           Miteq                   12 M          1c       16.11.2019
                                                  10P
291        high pass filter GSM 850/900           WHJ 2200-4EE             14               Wainwright GmbH         12 M          1c       16.11.2019
298        Univ. Radio Communication Tester       CMU 200                  832221/091       Rohde & Schwarz         pre-m         3
300        AC LISN (50 Ohm/50µH, 1-phase)         ESH3-Z5                  892 239/020      Rohde & Schwarz         12 M          -        22.05.2020
301        attenuator (20 dB) 50W, 18GHz          47-20-33                 AW0272           Lucas Weinschel         pre-m         2
302        horn antenna 40 GHz (Meas 1)           BBHA9170                 155              Schwarzbeck             36 M          -        14.03.2020
303        horn antenna 40 GHz (Subst 1)          BBHA9170                 156              Schwarzbeck             36 M          -        20.03.2020
331        Climatic Test Chamber -40/+180 Grad    HC 4055                  43146            Heraeus Vötsch          24 M          -        10.01.2021
341        Digital Multimeter                     Fluke 112                81650455         Fluke                   24 M          -        30.05.2020
342        Digital Multimeter                     Voltcraft M-4660A        IB 255466        Voltcraft               24 M          -        23.05.2021
347        laboratory site                        radio lab.               -                -                       -             5
348        laboratory site                        EMI conducted            -                -                       -             5
354        DC - Power Supply 40A                  NGPE 40/40               448              Rohde & Schwarz         pre-m         2
357        power sensor                           NRV-Z1                   861761/002       Rohde & Schwarz         24 M          -        21.05.2021
373        Single-Line V-Network (50 Ohm/5µH)     ESH3-Z6                  100535           Rohde & Schwarz         12 M          -        22.05.2020
377        EMI Test Receiver                      ESCS 30                  100160           Rohde & Schwarz         12 M          -        22.05.2020
389        Digital Multimeter                     Keithley 2000            0583926          Keithley                pre-m         -
392        Radio Communication Tester             MT8820A                  6K00000788       Anritsu                 12 M          -        01.07.2020
396        Thermo/Hygrometer                      Thermo/Hygrometer        -                Conrad                  24 M          -        09.01.2021
431        Model 7405                             Near-Field Probe Set     9305-2457        EMCO                    -             4
436        Univ. Radio Communication Tester       CMU 200                  103083           Rohde & Schwarz         12 M          -        25.05.2020
439        UltraLog-Antenna                       HL 562                   100248           Rohde & Schwarz         36 M          -        10.03.2020
                                                  System CTC-FAR-EMI-                       ETS-Lindgren /
443        CTC-FAR-EMI-RSE                                                 -                                        12 M          5        16.11.2019
                                                  RSE                                       CETECOM
                                                  WRCT 1850.0/2170.0-                       Wainwright
448        notch filter WCDMA_FDD II                                       5                                        12 M          1c       16.11.2019
                                                  5/40-10SSK                                Instruments GmbH
                                                  WRCT 824.0/894.0-5/40-
449        notch filter WCDMA FDD V                                        1                Wainwright              12 M          1c       16.11.2019
                                                  8SSK
454        Oscilloscope                           HM 205-3                 9210 P 29661     Hameg                   -             4
456        DC-Power supply 0-5 A                  EA 3013 S                207810           Elektro Automatik       pre-m         2
459        DC -Power supply 0-5 A , 0-32 V        EA-PS 2032-50            910722           Elektro Automatik       pre-m         2


CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 13 of 15
Ref.-No.




                                                                                                                         calibration
                                                                                                                         Interval of



                                                                                                                                       Remark
                           Equipment                         Type                   Serial-No.        Manufacturer                                 Cal
                                                                                                                                                   due

460        Univ. Radio Communication Tester         CMU 200                  108901              Rohde & Schwarz         12 M          -        30.05.2020
463        Universal source                         HP3245A                  2831A03472          Agilent                 -             4
466        Digital Multimeter                       Fluke 112                89210157            Fluke USA               24 M          -        30.05.2020
467        Digital Multimeter                       Fluke 112                89680306            Fluke USA               36 M          -        30.05.2021
468        Digital Multimeter                       Fluke 112                90090455            Fluke USA               36 M          -        30.04.2021
477        ReRadiating GPS-System                   AS-47                    -                   Automotive Cons. Fink   -             3
480        power meter (Fula)                       NRVS                     838392/031          Rohde & Schwarz         24 M          -        30.05.2021
482        filter matrix                            Filter matrix SAR 1      -                   CETECOM (Brl)           -             1d
                                                    AMF-5D-02501800-25-
484        pre-amplifier 2,5 - 18 GHz                                        1244554             Miteq                   12 M          -        16.11.2019
                                                    10P
           System CTC NSA-Verification SAR-         System EMI field (SAR)                       ETS Lindgren /
487                                                                          -                                           24 M          -        16.04.2021
           EMI                                      NSA                                          CETECOM
489        EMI Test Receiver                        ESU40                    1000-30             Rohde & Schwarz         12 M          -        30.06.2020
                                                    WRCG 1709/1786-
502        band reject filter                                                SN 9                Wainwright              pre-m         2
                                                    1699/1796-
                                                    WRCG 824/849-814/859-
503        band reject filter                                                SN 5                Wainwright              pre-m         2
                                                    60/10SS
                                                    WRCA 800/960-02/40-
512        notch filter GSM 850                                              SN 24               Wainwrght               12 M          1c       16.11.2019
                                                    6EEK
                                                    HF Relais Box Keithley
517        relais switch matrix                                              SE 04               Keithley                pre-m         2
                                                    System
523        Digital Multimeter                       L4411A                   MY46000154          Agilent                 24 M          -        23.05.2021
529        6 dB Broadband resistive power divider   Model 1515               LH 855              Weinschel               pre-m         2
           10 dB Broadband resistive power
530                                                 R 416110000              LOT 9828            -                       pre-m         2
           divider
                                                                                                                         36/12
549        Log.Per-Antenna                          HL025                    1000060             Rohde & Schwarz                       -        31.07.2021
                                                                                                                         M
552        high pass filter 2,8-18GHz               WHKX 2.8/18G-10SS        4                   Wainwright              12 M          1c       16.11.2019
557        System CTC-OTA-2                         R&S TS8991               -                   Rohde & Schwarz         12 M          5        24.01.2020
                                                                                                                         36/12
574        Biconilog Hybrid Antenna                 BTA-L                    980026L             Frankonia                             -        03.05.2022
                                                                                                                         M
584        Spectrum Analyzer                        FSU 8                    100248              Rohde & Schwarz         pre-m         -
594        Wideband Radio Communication Tester      CMW 500                  101757              Rohde & Schwarz         12 M          -        26.06.2020
597        Univ. Radio Communication Tester         CMU 200                  100347              Rohde & Schwarz         pre-m         -
600        power meter                              NRVD (Reserve)           834501/018          Rohde & Schwarz         24 M          -        30.05.2021
602        peak power sensor                        NRV-Z32 (Reserve)        835080              Rohde & Schwarz         24 M          -
611        DC power supply                          E3632A                   KR 75305854         Agilent                 pre-m         2
612        DC power supply                          E3632A                   MY 40001321         Agilent                 pre-m         2
613        Attenuator                               R416120000 20dB 10W      Lot. 9828           Radiall                 pre-m         2
616        Digitalmultimeter                        Fluke 177                88900339            Fluke                   24 M          -        30.05.2020
617        Power Splitter/Combiner                  ZFSC-2-2-S+              S F987001108        Mini Circuits           -             2
618        Power Splitter/Combiner                  50PD-634                 600994              JFW Industries USA      -             2
619        Power Splitter/Combiner                  50PD-634                 600995              JFW Industries, USA     -             3
620        EMI Test Receiver                        ESU 26                   100362              Rohde-Schwarz           12 M          -        30.05.2020
621        Step Attenuator 0-139 dB                 RSP                      100017              Rohde & Schwarz         pre-m         2
625        Generic Test Load USB                    Generic Test Load USB    -                   CETECOM                 -             2
634        Spectrum Analyzer                        FSM (HF-Unit)            826188/010          Rohde & Schwarz         pre-m         2
                                                    HDMI cable with
637        High Speed HDMI with Ethernet 1m                                  -                   KogiLink                -             2
                                                    Ethernet 1m
                                                    HDMI cable with
638        HDMI Kabel with Ethernet 1,5 m flach                              -                   Reichelt                -             2
                                                    Ethernet 1,5m
640        HDMI cable 2m rund                       HDMI cable 2m rund       -                   Reichelt                -             2
                                                    Certified HDMI cable
641        HDMI cable with Ethernet                                          -                   PureLink                -             2
                                                    with
644        Amplifierer                              ZX60-2534M+              SN865701299         Mini-Circuits           -             -
670        Univ. Radio Communication Tester         CMU 200                  106833              Rohde & Schwarz         24 M          -        30.05.2020
671        DC-power supply 0-5 A                    EA-3013S                 -                   Elektro Automatik       pre-m         2
678        Power Meter                              NRP                      101638              Rohde&Schwarz           pre-m         -
683        Spectrum Analyzer                        FSU 26                   200571              Rohde & Schwarz         12 M          -        30.05.2020
687        Signal Generator                         SMF 100A                 102073              Rohde&Schwarz           12 M          -        30.05.2020
688        Pre Amp                                  JS-18004000-40-8P        1750117             Miteq                   pre-m         -
690        Spectrum Analyzer                        FSU                      100302/026          Rohde&Schwarz           24 M          -        30.05.2021
691        OSP120 Base Unit                         OSP120                   106833              Rohde & Schwarz         12 M          -        30.05.2020
692        Bluetooth Tester                         CBT 32                   100236              Rohde & Schwarz         36 M          -        29.05.2020
                                                    CTC-Radio Lab
693        TS8997                                                            -                   Rohde&Schwarz           12 M          5        07.01.2020
                                                    1_TS8997
697        Power Splitter                           ZN4PD-642W-S+            165001445           Mini-Circuits           -             2
701        CMW500 wide. Radio Comm.                 CMW500                   158150              Rohde & Schwarz         24 M          -        30.07.2020
                                                    MA 4010-KT080-XPET-      MA4170-KT100-
703        INNCO Antennen Mast                                                                   INNCO                   pre-m         -
                                                    ZSS3                     XPET-ZSS3
                                                                             CO3000/933/384105   INNCO Systems
704        INNCON Controller                        CO 3000-4port                                                        pre-m         -
                                                                             16/L                GmBh
711        Harmonic Mixer 90 GHz - 140GHz           RPG FS-Z140              101004              RPG                     36 M          -        22.02.2020
712        Harmonic Mixer 75 GHz - 110GHz           FS-Z110                  101468              Rohde & Schwarz         36 M          -        22.02.2020
713        Harmonic Mixer, 50 GHz - 75GHz           FS-Z75                   101022              Rohde & Schwarz         24 M          -        05.07.2021
714        Signal Analyzer 67GHz                    FSW67                    104023              Rohde & Schwarz         24 M          -        04.07.2021
715        Harmonic Mixer, 140 GHz - 220GHz         FS-Z220                  101009              RPG Radiometer          36 M          -        03.08.2020


CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 14 of 15
Ref.-No.




                                                                                                                     calibration
                                                                                                                     Interval of



                                                                                                                                   Remark
                            Equipment                    Type                  Serial-No.        Manufacturer                                  Cal
                                                                                                                                               due

                                                                                            Physics
                                                                                            RPG Radiometer
716        Harmonic Mixer 220 GHz to 325 GHZ   FS-Z325                   101005                                      36 M          -        13.02.2020
                                                                                            Physics
747        Spectrum Analyzer                   FSU 26                    200152             Rohde & Schwarz          12 M          -        30.05.2020
748        Pickett-Potter Horn Antenna         FH-PP 4060                010001             Radiometer Physiscs      36 M          -
750        Pickett-Potter Horn Antenna         FH-PP 220                 010011             Radiometer Physics       36 M          -
751        Digital Optical System              optoCAN-FD Transceiver    17-010416          mk-messtechnik GmbH      -             -
752        Digital Optical System              optoCAN-FD Transceiver    17-010083          mk-messtechnik GmbH      -             -
753        Digital Optical System              optoCAN-FD Transceiver    17-010084          mk-messtechnik GmbH      -             -
754        Digital Optical System              optoCAN-FD Transceiver    17-010415          mk-messtechnik GmbH      -             -
                                               optoLAN-100-MAX
755        Digital Optical System                                        17-010795          mk-messtechnik GmbH      -             -
                                               Transceiver
           WIDEBAND RADIO
757                                            CMW500                    163673             Rohde&Schwarz            12 M          -        30.05.2020
           COMMUNICATION
                                                                                            Elektro-Automatik
781        Power Supply                        PS 2042-10 B              2815450369                                  -             -
                                                                                            GmbH &Co.KG
                                                                                            lektro-Automatik
782        Power Supply                        PS 2042-10 B              2815450348                                  -             -
                                                                                            GmbH &Co.KG
783        Spectrum Analyzer                   FSU 26                    100414             Rohde & Schwarz          12 M          -        30.05.2020
784        Power Supply                        NGSM 32/10                00196              Rohde & Schwarz          12 M          -
                                               RF Step Attenuator
785        RSP                                                           860712/012         Rohde & Schwarz          12 M          -
                                               0…139.9dB
786        SAR Probe                           ES3DV3                    3340               Speag                    36 M          -        14.02.2021
787        OSP                                 OSP B157WX                101264             Rohde & Schwarz          24 M          -        30.05.2020
                                                                                            Seibersdorf
788        Precision Omnidirectional Dipole    POD 618                   6182558/Q                                   36 M          -        30.06.2021
                                                                                            Labaratories
                                                                                            Seibersdorf
789        Precision Omnidirectional Dipole    POD 16                    162496/Q                                    36 M          -        30.06.2021
                                                                                            Laboratories
                                                                                            Antenna System
790        Horn Antenna                        ASY-SGH-124-SMA           29F14182337                                 36 M          -        08.10.2021
                                                                                            Solutions
791        Pickett-Potter Horn Antenna         FH-PP-325                 10024              Radiometer Physics       36 M          -
792        Pickett-Potter Horn Antenna         FH-PP 075                 10006              Radiometer Physics       36 M          -
793        Pickett-Potter Horn Antenna         FH-PP 140                 10008              Radiometer Physics       36 M          -
794        Pickett-Potter Horn Antenna         FH-PP 110                 10014              Radiometer Physics       36 M          -
795        SGH Antenna                         SGH-26-WR10               1144               Anteral S.L.             36 M          -
798        WR-22 Rectangular Gain Horn         SAR-2309-22-S2            13254-01           SAGE Millimeter, Inc.    36 M          -
799        Transceiver                         optoLAN-Gb                18-014746          mk messtechnik           pre-m         -
801        Spectrum Analyzer                   FSP 13                    100960             Rohde & Schwarz          24 M          -        14.01.2021
                                                                                            NARDA Safety
802        Exposure Level Tester               ELT-400                   O-0026                                      24 M          -        30.01.2021
                                                                                            Solutions
                                                                                            Narda Safety Test
803        Probe                               ELT probe 3cm²            O-0026                                      24 M          -        30.01.2021
                                                                                            Solution
805        Thermo-Hygrometer                   Web-Thermo-Hygrometer     02749814           W&T                      24 M          -
806        AC2600 Smart Wifi Router            Netgear Nighthawk x4S     5K5188590067B      Netgear                  -             -
                                               Direct Coupler C-05020-
807        Direct Coupler                                                511                ET Industries            -             -
                                               10
808        Diode Power Sensor                  NRV-Z1                    829894/001         Rohde & Schwarz          24 M          -        24.05.2021
                                                                                            Pasternack Enterprises
809        Standard gain Horn Antenna          WR-159 Horn Antenna       -                                           -             -
                                                                                            Inc.




CETECOM_TR17_1_0133808T05a_C1.docx


Test Report 17-1-0133808T05a-C1, Page 15 of 15



8.1.3. Legend

Note / remarks                       Calibrated during system calibration:
                           1a        System CTC-SAR-EMS (Ref.-No. 442)
                           1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                           1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                           1d        System CTC-SAR-EMI (Ref.-No . 441)
                           1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                           1f        System CTC-CTIA-OTA (Ref.-No . 420)
                           1g        System CTC-FAR-EMS (Ref.-No . 444)
                           2         Calibration or equipment check immediately before measurement
                           3         Regulatory maintained equipment for functional check or support purpose
                           4         calibration of this equipment
                                     Ancillary equipment   without has no effect
                                                                   calibration   onmechanical
                                                                               e.g. measuring result
                                                                                              equipment or monitoring equipment
                           5         Test System


Interval of calibration    12 M      12 month
                           24 M      24 month
                           36 M      36 month
                           24/12 M   Calibration every 24 months, between this every 12 months internal validation
                           36/12 M   Calibration every 36 months, between this every 12 months internal validation
                           Pre-m     Check before starting the measurement
                           -         Without calibration




9. Versions of test reports (change history)

      Version             Applied changes                                                                                     Date of release
        --                Initial release                                                                                      2019-10-18
        C1                Removal ISED ID, new references to annexes                                                           2019-11-07




                                                END OF TEST REPORT




CETECOM_TR17_1_0133808T05a_C1.docx



Document Created: 2019-11-07 12:19:42
Document Modified: 2019-11-07 12:19:42

© 2024 FCC.report