Test Report 15B annex

FCC ID: V2TSDHTAG3NFC

Test Report

Download: PDF
FCCID_4508965

                                  Annex 1: Measurement diagrams to
                                        TEST REPORT
                                     No: 17-1-0133808T05a-C1



                                                        According to:
                                                 FCC Regulations Part 15B
                                                 Part 15.109 (Class B limits)

                                                       ISED-Regulations
                                                        ICES-003, Issue 6


                                                                for
                                    WITTE - Velbert GmbH & Co. KG

                                           DAG SDH TAG3 NFC
                                        Outer Door Handle with NFC

                                              FCC ID: V2T-SDHTAG3NFC




                                            Laboratory Accreditation and Listings




                                                   Accredited EMC-Test Laboratory




                                      accredited according to DIN EN ISO/IEC 17025

                                                       CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                        Page 1 of 4
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Annex A1-C1 to Test Report to 17-1-0133808T05a-C1, Page 2 of 4


Table of contents
1. MEASUREMENT DIAGRAMS OF EMISSION TEST                                        3
  1.1. Diagrams of radiated field strength emissions, 30 MHz - 1 GHz standing   3
  1.2. Diagrams of radiated field strength emissions, 30 MHz - 1 GHz laying     4




CETECOM_TR17_1_0133808T05a_A1_C1.docx


Annex A1-C1 to Test Report to 17-1-0133808T05a-C1, Page 3 of 4


1. Measurement diagrams of emission test
1.1. Diagrams of radiated field strength emissions, 30 MHz - 1 GHz standing

                                                                 3.01
Common Information
  Test description:                                   Electric Field Strength Measurement
  Test site and distance:                             Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance
  Version of Testsoftware:                            EMC32 V9.25.0
  Distance correction:                                not used
  Used filter:                                        not used
  Technical Data:                                     please see page 2 for detailed data of measurement setup
  Test specification.:                                FCC 15.109 Class B; ICES-003. Issue 6
  Operator:                                           HLa
  Operating Mode:                                     ping mode
  Environmental Conditions::                          Humidity : 48,3%rH; Temperature: 26,6°C
  EUT Setup:                                          standing
  Verdict:                                            Passed


EUT Information
  Manufacturer:                                       WITTE Velbert GmbH & Co. KG
  Product:                                            DAG SDH TAG3 NFC
  EUT Model:                                          Outer Door Handle with NFC
  Serial number:                                      191004-03
  SW:                                                 19.28.11
  HW:                                                 19.45.00
        Level in dBµV/m




Final_Result
    Frequency             QuasiP     Limit   Margin       Bandwidt   Heigh   Pol    Azimut   Corr.
      (MHz)                 eak     (dBµV/    (dB)            h        t               h     (dB)
                          (dBµV/      m)                    (kHz)    (cm)            (deg)
                            m)
     869.640000             32.28    46.00      13.72      120.000   368.0   H       138.0   26.8




CETECOM_TR17_1_0133808T05a_A1_C1.docx


Annex A1-C1 to Test Report to 17-1-0133808T05a-C1, Page 4 of 4

1.2. Diagrams of radiated field strength emissions, 30 MHz - 1 GHz laying


                                                                 3.02
Common Information
  Test description:                                   Electric Field Strength Measurement
  Test site and distance:                             Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance
  Version of Testsoftware:                            EMC32 V9.25.0
  Distance correction:                                not used
  Used filter:                                        not used
  Technical Data:                                     please see page 2 for detailed data of measurement setup
  Test specification.:                                FCC 15.109 Class B; ICES-003. Issue 6
  Operator:                                           HLa
  Operating Mode:                                     ping mode
  Environmental Conditions::                          Humidity : 47,0%rH; Temperature: 26,7°C
  EUT Setup:                                          laying
  Verdict:                                            Passed

EUT Information
  Manufacturer:                                       WITTE Velbert GmbH & Co. KG
  Product:                                            DAG SDH TAG3 NFC
  EUT Model:                                          Outer Door Handle with NFC
  Serial number:                                      191004-03
  SW:                                                 19.28.11
  HW:                                                 19.45.00
        Level in dBµV/m




Final_Result
    Frequency             QuasiP     Limit   Margin       Bandwidt   Heigh   Pol    Azimut   Corr.
      (MHz)                 eak     (dBµV/    (dB)            h        t               h     (dB)
                          (dBµV/      m)                    (kHz)    (cm)            (deg)
                            m)
      95.000000             20.26    43.50      23.24      120.000   360.0   H         0.0     8.2
     156.450000             23.05    43.50      20.45      120.000   197.0   H        94.0     9.0


                                                        END OF ANNEX
CETECOM_TR17_1_0133808T05a_A1_C1.docx



Document Created: 2019-11-10 13:58:46
Document Modified: 2019-11-10 13:58:46

© 2024 FCC.report