                          FCC Radio Test Report


                                   This report concerns: Original Grant


              Project No.             19050134
              Equipment               Charge Rise
              Test Model              SFQ—15
              Series Model            N/A
              Applicant               Beautiful Enterprise Co., Ltd.
              Address                 27th Floor, Beautiful Group Tower, 77 Connaught
                                      Road Central, Hong Kong



               Date of Receipt      : May 28, 2019
               Date of Test         : May 31, 2019 ~Jun. 18, 2019
              Issued Date           : Jul. 17, 2019
              Tested by             : BTL Inc.



                                                                  *                   m
              Testing Engineer                    :           l['b” {Hi               ldl I
                                                                      (Vincent Tan)


              Technical Manager                                 \S‘QE’,\/W ]JJ\
                                                                      (Steven Lu)


              Authorized Signatory                :          7’£ML
                                                                       (Ethan Ma)




                     B TL                                I N C .
          No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan,
                              Guangdong, China.
             TEL: +86—769—8318—3000      FAX: +86—769—8319—6000
                                         o
                                           $n




                                         F:’:’T/F;_fl\:‘j:
                                            n             [ACCREDITED)

                                                 Certificate #£5123.02


Report No.: BTL—FCCP—1—1905C 134                                                                    Page 1 of 29
                                                                                              Report Version: RO1


   Declaration
   BTL represents to the client that testing is done in accordance with standard procedures as applicable and
   that test instruments used has been calibrated with standards traceable to international standard(s) and/or
   national standard(s).
   BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility
   to ensure that additional production units of this model are manufactured with the identical electrical and
   mechanical components. BTL shall have no liability for any declarations, inferences or generalizations
   drawn by the client or others from BTL issued reports.
   The report must not be used by the client to claim product certification, approval, or endorsement by
   NVLAP, NIST, A2LA, or any agency of the U.S. Government.
   This report is the confidential property of the client. As a mutual protection to the clients, the public and
   ourselves, the test report shall not be reproduced, except in full, without our written approval.
   BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements,
   and accredited by the conformity assessment authorities listed in this test report.
   BTL is not responsible for the sampling stage, so the results only apply to the sample as received.
   The information, data and test plan are provided by manufacturer which may affect the validity of results,
   so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of
   applied standards and in all the possible configurations as representative of its intended use.
   Limitation
   For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
   test report is (are) included in the conformity assessment authorities acceptance respective.
   Please note that the measurement uncertainty is provided for informational purpose only and are not use
   in determining the Pass/Fail results.




Report No.: BTL-FCCP-1-1905C134                                                                         Page 2 of 29
                                                                                                  Report Version: R01


                                  Table of Contents                 Page


    REPORT ISSUED HISTORY                                              4
    1 . GENERAL SUMMARY                                                5
    2 . SUMMARY OF TEST RESULTS                                        6
       2.1 TEST FACILITY                                               7
       2.2 MEASUREMENT UNCERTAINTY                                     7
    3 . GENERAL INFORMATION                                            8
       3.1 GENERAL DESCRIPTION OF EUT                                  8
       3.2 DESCRIPTION OF TEST MODES                                   9
       3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10
       3.4 SUPPORT UNITS                                             10
    4 . AC POWER LINE CONDUCTED EMISSIONS TEST                       11
       4.1 LIMIT                                                     11
       4.2 TEST PROCEDURE                                            11
       4.3 DEVIATION FROM TEST STANDARD                              11
       4.4 TEST SETUP                                                12
       4.5 EUT OPERATING CONDITIONS                                  12
       4.6 EUT TEST CONDITIONS                                       12
       4.7 TEST RESULTS                                              12
    5 . RADIATED EMISSION TEST                                       13
       5.1 LIMIT                                                     13
       5.2 TEST PROCEDURE                                            13
       5.3 DEVIATION FROM TEST STANDARD                              13
       5.4 TEST SETUP                                                14
       5.5 EUT OPERATING CONDITIONS                                  14
       5.6 EUT TEST CONDITIONS                                       14
       5.7 TEST RESULT - 9 KHZ TO 30 MHZ                             14
       5.8 TEST RESULT - 30 MHZ TO 1000 MHZ                          14
    6 . MEASUREMENT INSTRUMENTS LIST                                 15
    7 . EUT TEST PHOTO                                               16
    APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS                   19
    APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ                 22
    APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ              27




Report No.: BTL-FCCP-1-1905C134                                      Page 3 of 29
                                                               Report Version: R01


                                  REPORT ISSUED HISTORY

         Report Version                         Description   Issued Date
             R00              Original Issue.                 Jul. 11, 2019
              R01             Modified the comments of TCB.   Jul. 17, 2019




Report No.: BTL-FCCP-1-1905C134                                     Page 4 of 29
                                                              Report Version: R01


3LL                                                                                            3@
 1. GENERAL SUMMARY

     Equipment      _: Charge Rise
     Brand Name :       SounDFREAQ.


     Test Model     _: SFQ—A15
     Series Model :     N/A
     Applicant      :   Beautiful Enterprise Co., Ltd.
     Manufacturer   :   Beautiful Enterprise Co., Ltd.
     Address        :   27th Floor, Beautiful Group Tower, 77 Connaught Road Central, Hong Kong
     Factory        :   Shenzhen Synchron Electronics Co., Ltd.
     Address        :   No. 9 Mei Li Road, Xia Mei Lin, Fu Tian Area, Shenzhen, Guangdong, P.R.
                        China
     Date of Test : May 31, 2019 ~Jun. 18, 2019
     Test Sample : Engineering Sample No.: DG19053050
     Standard(s) : FCC Part15, Subpart C (15.209)
                        ANSI C63.10—2013

  The above equipment has been tested and found compliance with the requirement of the relative
  standards by BTL Inc.
  The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
  BTL—FCCP—1—1905C134) were obtained utilizing the test procedures, test instruments, test sites
  that has been accredited by the Authority of A2LA according to the ISO/IEC 17025 quality
  assessment standard and technical standard(s).




Report No.: BTL—FCCP—1—1905C 134                                                           Page 5 of 29
                                                                                     Report Version: RO1


 2. SUMMARY OF TEST RESULTS

  Test procedures according to the technical standard(s):
                                  FCC Part15, Subpart C (15.209)

       Standard(s)
                                  Test Item                 Test Result   Judgment      Remark
         Section
                          AC Power Line Conducted
         15.207                                             APPENDIX A     PASS          ------
                                Emissions
                                                            APPENDIX B
        15.209(a)            Radiated Emissions                            PASS          ------
                                                            APPENDIX C
  NOTE:
      (1) “N/A” denotes test is not applicable to this device.




Report No.: BTL-FCCP-1-1905C134                                                            Page 6 of 29
                                                                                     Report Version: R01


  2.1 TEST FACILITY
     The test facilities used to collect the test data in this report is at the location of No.3, Jinshagang
    1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China.
     BTL's Test Firm Registration Number for FCC: 357015
     BTL's Designation Number for FCC: CN1240

  2.2 MEASUREMENT UNCERTAINTY
    ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the
    emissions test results be included in the report. The measurement uncertainties given below
    are based on a 95% confidence level (based on a coverage factor (k=2))
    The BTL measurement uncertainty as below table:

     A. AC power line conducted emissions Measurement:

                    Test Site   Method       Measurement Frequency Range             U, (dB)
                    DG-C02      CISPR             150 kHz ~ 30 MHz                    2.32

     B. Radiated emissions Measurement:

                                            Measurement Frequency            Ant.
                    Test Site   Method                                               U, (dB)
                                                    Range                    H/V
                                                9 KHz~30 MHz                  V        3.79
                                                9 KHz~30 MHz                  H        3.57
                                              30 MHz~200 MHz                  V        3.82
                                              30 MHz~200 MHz                  H        3.78
                                             200 MHz~1,000 MHz                V        4.10
                   DG-CB03      CISPR
                                             200 MHz~1,000 MHz                H        4.06
                                                1 GHz~18 GHz                  V        3.12
                                                1 GHz~18 GHz                  H        3.68
                                               18 GHz~40 GHz                  V        4.15
                                               18 GHz~40 GHz                  H        4.14

    Note: Unless specifically mentioned, the uncertainty of measurement has not been taken into
    account to declare the compliance or non-compliance to the specification.




Report No.: BTL-FCCP-1-1905C134                                                                     Page 7 of 29
                                                                                              Report Version: R01


3UL
 3. GENERAL INFORMATION

  3.1 GENERAL DESCRIPTION OF EUT

      Equipment                    Charge Rise

      Brand Name
      Model Name                   SFQ—15
      Series Model                 N/A
      Model Difference(s)          N/A
      Hardware Version             V1.0
      Software Version             V1.0
                                   DC voltage supplied from AC/DC adapter.
      Power Source
                                   Model: DYS836—120250W—K
      Power Rating                 I/P: 100—240V ~50/60Hz, 1.0A MAX      O/P: 12.0V === 2.5A
      Operation Frequency          120kHz~130kHz

  Note:
  1. For a more detailed features description, please refer to the manufacturer‘s specifications or the
     user‘s manual.

  2. Channel List:
                      Test Channel                               Test Frequency
                         CHO1                                      127.759KHz




Report No.: BTL—FCCP—1—1905C 134                                                              Page 8 of 29
                                                                                        Report Version: RO1


  3.2 DESCRIPTION OF TEST MODES

  The test system was pre-tested based on the consideration of all possible combinations of EUT
  operation mode.

            Pretest Mode                                  Description
              Mode 1                                     TX Mode
  Following mode(s) as (were) found to be the worst case(s) and selected for the final test.

                              AC power line conducted emissions test
           Final Test Mode                                Description
               Mode 1                                      TX Mode

                                       Radiated emissions test

           Final Test Mode                                Description

               Mode 1                                      TX Mode

  Remark: The EUT has the maximum average output power when the support unit is in low power
          and being charged by EUT.




Report No.: BTL-FCCP-1-1905C134                                                             Page 9 of 29
                                                                                      Report Version: R01


  3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED




  3.4 SUPPORT UNITS

   Item       Equipment              Brand        Model No.      Series No.
    A        Mobile phone          SAMSUNG        GALAXY S9         N/A

   Item       Cable Type          Shielded Type   Ferrite Core     Length
     1         DC Cable               NO              NO           1.8m




Report No.: BTL-FCCP-1-1905C134                                         Page 10 of 29
                                                                   Report Version: R01


 4. AC POWER LINE CONDUCTED EMISSIONS TEST

  4.1 LIMIT

                                                              Limit (dBμV)
    Frequency of Emission (MHz)
                                                Quasi-peak                       Average
               0.15 - 0.5                        66 to 56*                       56 to 46*
               0.5 - 5.0                            56                              46
               5.0 - 30.0                           60                              50
   Note:
  (1) The tighter limit applies at the band edges.
  (2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the
      frequency in the range.

  4.2 TEST PROCEDURE
   a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
       to the power mains through a line impedance stabilization network (LISN). All other support
       equipment powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
       impedance for the measuring instrument.
   b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
       and forth in the center forming a bundle 30 to 40 cm long.
    c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
       cable may be terminated, if required, using the correct terminating impedance. The overall
       length shall not exceed 1 m.
   d. LISN at least 80 cm from nearest part of EUT chassis.
   e. For the actual test configuration, please refer to the related Item –EUT Test Photos.

  4.3 DEVIATION FROM TEST STANDARD
  No deviation




Report No.: BTL-FCCP-1-1905C134                                                                Page 11 of 29
                                                                                         Report Version: R01


  4.4 TEST SETUP


                       Vertical Reference Ground Plane




               40 cm           EUT                                          Test Receiver



                                                         80 cm

               LISN


                                             Horizontal Reference Ground Plane




  4.5 EUT OPERATING CONDITIONS
  The EUT was configured for testing in a typical fashion (as a customer would normally use it). The
  EUT has been programmed to continuously transmit during test. This operating condition was
  tested and used to collect the included data.

  4.6 EUT TEST CONDITIONS
  Temperature: 25°C Relative Humidity: 53%               Test Voltage: AC 120V/60Hz

  4.7 TEST RESULTS
  Please refer to the APPENDIX A.

  Remark:
      (1) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP
          Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
          shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
          but AVG Mode didn‘t perform.In this case, a “ * ” marked in AVG Mode column of
          Interference Voltage Measured.
      (2) Measuring frequency range from 150 kHz to 30 MHz.




Report No.: BTL-FCCP-1-1905C134                                                                  Page 12 of 29
                                                                                            Report Version: R01


  5. RADIATED EMISSION TEST

 5.1 LIMIT

  In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit
  in the table below has to be followed.

  LIMITS OF RADIATED EMISSION MEASUREMENT(9 kHz-1000 MHz)

             Frequency                       Field Strength              Measurement Distance
                (MHz)                     (microvolts/meter)                     (meters)
             0.009-0.490                     2400/F(kHz)                           300
             0.490-1.705                    24000/F(kHz)                            30
              1.705-30.0                          30                                30
                 30-88                           100                                 3
                88-216                           150                                 3
               216-960                           200                                 3
              Above 960                          500                                 3

  Note:
     (1) The limit for radiated test was performed according to FCC PART 15C.
     (2) The tighter limit applies at the band edges.
     (3) Emission level (dBuV/m)=20log Emission level (uV/m).

 5.2 TEST PROCEDURE
   a. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the
       top of a rotating table 0.8 meter above the ground at a 3 meter semi-anechoic chamber. The
       table was rotated 360 degrees to determine the position of the highest radiation.(below 1 GHz)
   b. The height of the equipment or of the substitution antenna shall be 0.8m or 1.5m; the height of
       the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of
       the antenna are set to make the measurement.
   c. For each suspected emission, the EUT was arranged to its worst case and then the antenna
       was tuned to heights find the maximum reading (used Bore sight function).
   d. The initial step in collecting radiated emission data is a receiver peak detector mode
       pre-scanning the measurement frequency range. Significant peaks are then marked and then
       Quasi Peak detector mode re-measured.
   e. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the
       Peak reading compliance with the QP Limits and then QP Mode measurement didn‘t perform.
       (below 1 GHz)
    f. For the actual test configuration, please refer to the related Item –EUT Test Photos.

 5.3 DEVIATION FROM TEST STANDARD
  No deviation.




Report No.: BTL-FCCP-1-1905C134                                                              Page 13 of 29
                                                                                        Report Version: R01


 5.4 TEST SETUP

                                            9 kHz-30 MHz




                                          30 MHz to 1 GHz
                                          Absorbers



                                                                               1-4 m

                                            3m


                       EUT
                                                                              1m
             0.8 m


                                        Ground Plane




                                                              Receiver        Amp.



 5.5 EUT OPERATING CONDITIONS
  The EUT was programmed to be in continuously transmitting mode.

 5.6 EUT TEST CONDITIONS
  Temperature: 24°C Relative Humidity: 68%         Test Voltage: AC 120V/60Hz

 5.7 TEST RESULT - 9 kHz TO 30 MHz

  Please refer to the APPENDIX B

   Remark:
       (1) Distance extrapolation factor = 40 log (specific distance / test distance) (dB).
       (2) Limit line = specific limits (dBuV) + distance extrapolation factor.

 5.8 TEST RESULT - 30 MHz TO 1000 MHz
  Please refer to the APPENDIX C.

Report No.: BTL-FCCP-1-1905C134                                                             Page 14 of 29
                                                                                       Report Version: R01


 6. MEASUREMENT INSTRUMENTS LIST

                             AC Power Line Conducted Emissions
   Item Kind of Equipment Manufacturer       Type No.       Serial No.               Calibrated until
     1 EMI Test Receiver       R&S             ESCI           100382                 Mar. 10, 2020
     2          LISN          EMCO            3816/2           52765                 Mar. 10, 2020
     3 50ohm Terminator        SHX            TF5-3         15041305                 Mar. 10, 2020
          Artificial-Mains SCHWARZBEC
     4                                      NSLK 8127        8127685                  Mar. 10, 2020
              Network           K
           TRANSIENT
     5                         EM            EM-7600            772                   Mar. 10, 2020
             LIMITER
          Measurement                        EZ-EMC
     6                        Farad                             N/A                        N/A
             Software                    Ver.NB-03A1-01
     7          Cable          N/A            RG223             12m                   Mar. 12, 2020


                                  Radiated Emissions - 9 kHz to 30 MHz
   Item Kind of Equipment        Manufacturer      Type No.         Serial No.       Calibrated until
     1    Loop Antenna               EM          EM-6876-1             230           Jan. 15, 2020
     2        Cable                  N/A           RG 213/U           C-102          May 31, 2020
     3 EMI Test Receiver            R&S              ESCI            100895          Mar. 10, 2020
          Measurement                              EZ-EMC
     4                              Farad                              N/A                 N/A
            Software                           Ver.NB-03A1-01


                                  Radiated Emissions - 30 MHz to 1 GHz
   Item Kind of Equipment        Manufacturer      Type No.         Serial No.       Calibrated until
     1       Antenna             Schwarzbeck      VULB9160          9160-3232        Mar. 09, 2020
     2       Amplifier                HP            8447D          2944A09673        Aug. 11, 2019
     3      Receiver                Agilent        N9038A         MY52130039         Aug. 11, 2019
                                              LMR-400(30MHz-
     4            Cable              emci                              N/A            May 24, 2020
                                               1GHz)(8m+5m)
     5         Controller             CT            SC100              N/A                 N/A
     6         Controller             MF           MF-7802        MF780208416              N/A
              Measurement                          EZ-EMC
     7                              Farad                              N/A                 N/A
               Software                        Ver.NB-03A1-01

         Remark: “N/A” denotes no model name, serial no. or calibration specified.
                 All calibration period of equipment list is one year.




Report No.: BTL-FCCP-1-1905C134                                                           Page 15 of 29
                                                                                     Report Version: R01


   7. EUT TEST PHOTO

                        AC Power Line Conducted Emissions Test Photos




Report No.: BTL-FCCP-1-1905C134                                              Page 16 of 29
                                                                        Report Version: R01


                                  Radiated Measurement Photos
                                        9 kHz to 30 MHz




Report No.: BTL-FCCP-1-1905C134                                      Page 17 of 29
                                                                Report Version: R01


                                  Radiated Emissions Test Photos

                                      30 MHz to 1000 MHz




Report No.: BTL-FCCP-1-1905C134                                         Page 18 of 29
                                                                   Report Version: R01


        APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS




Report No.: BTL-FCCP-1-1905C134                     Page 19 of 29
                                               Report Version: R01


  Test Mode:       TX Mode

                                             Line




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 20 of 29
                                                            Report Version: R01


  Test Mode:       TX Mode

                                            Neutral




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 21 of 29
                                                            Report Version: R01


         APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ




Report No.: BTL-FCCP-1-1905C134                        Page 22 of 29
                                                  Report Version: R01


  Test Mode:       TX Mode

                                            Ant 0°




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 23 of 29
                                                            Report Version: R01


  Test Mode:       TX Mode

                                            Ant 0°




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 24 of 29
                                                            Report Version: R01


  Test Mode:       TX Mode

                                            Ant 90°




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 25 of 29
                                                            Report Version: R01


  Test Mode:       TX Mode

                                            Ant 90°




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 26 of 29
                                                            Report Version: R01


      APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ




Report No.: BTL-FCCP-1-1905C134                      Page 27 of 29
                                                Report Version: R01


  Test Mode:       TX Mode

                                            Vertical




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




Report No.: BTL-FCCP-1-1905C134                                  Page 28 of 29
                                                            Report Version: R01


  Test Mode:       TX Mode


                                          Horizontal




  REMARKS:
  (1) Measurement Value = Reading Level + Correct Factor.
  (2) Margin Level = Measurement Value - Limit Value.




                                        End of Test Report