Test Report HAC RF Appendix A

FCC ID: UZ7TC57HO

Test Report

Download: PDF
FCCID_4047227

Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2018/9/13


HAC_E_Dipole_835
DUT: HAC-Dipole 835 MHz

Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.6 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn910; Calibrated: 2018/6/21
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD835 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x361x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 123.0 V/m; Power Drift = -0.07 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 109.3 V/m
Average value of Total=(109.3+107.3) / 2 = 108.3 V/m

                                         PMF scaled E-field
                                          Grid 1 M4 Grid 2 M4 Grid 3 M4
                                          105.7 V/m      109.3 V/m   108.0 V/m
                                          Grid 4 M4      Grid 5 M4   Grid 6 M4
                                          62.51 V/m      63.56 V/m   62.89 V/m
                                          Grid 7 M4      Grid 8 M4   Grid 9 M4
                                          105.7 V/m      107.3 V/m   105.6 V/m
                                                        Cursor:
                                                   Total = 109.3 V/m
                                                    E Category: M4
                                               Location: -1, -75.5, 9.7 mm




                    0 dB = 109.3 V/m = 40.77 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2018/9/13


HAC_E_Dipole_1880
DUT: HAC Dipole 1880 MHz

Communication System: CW; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.6 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn910; Calibrated: 2018/6/21
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD1880 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 147.2 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 88.77 V/m
Average value of Total=(88.77+84.5) / 2 = 86.635 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          88.09 V/m      88.77 V/m   86.29 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          69.40 V/m      69.59 V/m   67.75 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          83.12 V/m      84.50 V/m   83.48 V/m
                                                        Cursor:
                                                   Total = 88.77 V/m
                                                    E Category: M3
                                                 Location: 1, -31, 9.7 mm




                    0 dB = 88.77 V/m = 38.97 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2018/9/14


HAC_E_Dipole_2450
DUT: HAC Dipole 2450 MHz

Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.6 ℃

DASY5 Configuration:
- Probe: EF3DV3 - SN4053; ConvF(1, 1, 1); Calibrated: 2018/3/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn910; Calibrated: 2018/6/21
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD2450 = 10mm & 15mm
2/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid: dx=0.5000
mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 76.03 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 90.56 V/m
Average value of Total=(88.75+90.56) / 2 = 89.655 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          88.04 V/m      88.75 V/m   85.98 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          77.84 V/m      78.04 V/m   76.20 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          89.60 V/m      90.56 V/m   87.68 V/m
                                                        Cursor:
                                                   Total = 90.56 V/m
                                                    E Category: M3
                                               Location: 0.5, 24.5, 9.7 mm




                    0 dB = 90.56 V/m = 39.14 dBV/m


Test Laboratory: Sporton International Inc. SAR/HAC Testing Lab       Date: 2018/9/13


HAC_E_Dipole_2600
DUT: HAC Dipole 2600 MHz

Communication System: CW ; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium: Air Medium parameters used: σ = 0 S/m, εr = 1; ρ = 0 kg/m3
Ambient Temperature:23.6 ℃

DASY5 Configuration:
- Probe: ER3DV6 - SN2358; ConvF(1, 1, 1); Calibrated: 2018/1/19;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn910; Calibrated: 2018/6/21
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BA;
- Measurement SW: DASY52, Version 52.10 (0);SEMCAD X Version 14.6.10 (7417)


E Scan - measurement distance from the probe sensor center to CD2600 = 10mm &
15mm/Hearing Aid Compatibility Test at 15mm distance (41x181x1): Interpolated grid:
dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 72.46 V/m; Power Drift = 0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 92.14 V/m
Average value of Total=(84.22+92.14) / 2 = 88.18 V/m

                                         PMF scaled E-field
                                          Grid 1 M3 Grid 2 M3 Grid 3 M3
                                          83.71 V/m      84.22 V/m   82.43 V/m
                                          Grid 4 M3      Grid 5 M3   Grid 6 M3
                                          87.34 V/m      89.03 V/m   87.99 V/m
                                          Grid 7 M3      Grid 8 M3   Grid 9 M3
                                          90.54 V/m      92.14 V/m   90.72 V/m
                                                        Cursor:
                                                   Total = 92.14 V/m
                                                    E Category: M3
                                                 Location: 0, 20, 9.7 mm




                    0 dB = 92.14 V/m = 39.29 dBV/m



Document Created: 2019-03-30 00:43:13
Document Modified: 2019-03-30 00:43:13