RFExp

FCC ID: UZ7FX9600

RF Exposure Info

Download: PDF
FCCID_3626643

         RF Exposure Evaluation Report                                           Report No. : FA751510




                 RF Exposure Evaluation Report

                        APPLICANT      : Zebra Technologies Corporation

                        EQUIPMENT      : RFID READER

                        BRAND NAME     : Zebra

                        MODEL NAME     : FX9600

                        FCC ID         : UZ7FX9600

                        STANDARD       : 47 CFR Part 2.1091


      We, SPORTON INTERNATIONAL INC., would like to declare that the device has been
      evaluated in accordance with 47 CFR Part 2.1091, and pass the limit. Without written
      approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced
      except in full.




          Reviewed by: Eric Huang / Manager




          Approved by: Jones Tsai / Manager



                                 SPORTON INTERNATIONAL INC.
No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City, Taiwan (R.O.C.)




SPORTON INTERNATIONAL INC.                                        Page Number        : 1 of 7
TEL : 886-3-327-3456                                              Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                              Report Version     : Rev. 01
FCC ID : UZ7FX9600


            RF Exposure Evaluation Report                                                                                         Report No. : FA751510

                                                        Table of Contents
1. ADMINISTRATION DATA ........................................................................................................................... 4
     1.1.     Testing Laboratory ............................................................................................................................. 4
2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 5
3. MAXIMUM RF AVERAGE OUTPUT POWER AMONG PRODUCTION UNITS ........................................ 5
4. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 6
5. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 7
     5.1.     Standalone Power Density Calculation ............................................................................................. 7




SPORTON INTERNATIONAL INC.                                                                                    Page Number        : 2 of 7
TEL : 886-3-327-3456                                                                                          Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                                                                          Report Version     : Rev. 01
FCC ID : UZ7FX9600


         RF Exposure Evaluation Report                                           Report No. : FA751510
                                         Revision History
   REPORT NO.        VERSION                        DESCRIPTION                     ISSUED DATE

    FA751510         Rev. 01   Initial issue of report                               Oct. 30, 2017




SPORTON INTERNATIONAL INC.                                        Page Number        : 3 of 7
TEL : 886-3-327-3456                                              Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                              Report Version     : Rev. 01
FCC ID : UZ7FX9600


          RF Exposure Evaluation Report                                                 Report No. : FA751510
1. Administration Data

1.1. Testing Laboratory
Testing Laboratory
Test Site                    SPORTON INTERNATIONAL INC.
                             No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan
                             City, Taiwan (R.O.C.)
Test Site Location
                             TEL: +886-3-327-3456
                             FAX: +886-3-328-4978


                                                Applicant
Company Name                 Zebra Technologies Corporation
Address                      1 Zebra Plaza, Holtsville, NY 11742-1300, USA


                                              Manufacturer
Company Name                 Zebra Technologies Corporation
Address                      1 Zebra Plaza, Holtsville, NY 11742-1300, USA




SPORTON INTERNATIONAL INC.                                               Page Number        : 4 of 7
TEL : 886-3-327-3456                                                     Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                                     Report Version     : Rev. 01
FCC ID : UZ7FX9600


         RF Exposure Evaluation Report                                                          Report No. : FA751510
2. Description of Equipment Under Test (EUT)
                                          Product Feature & Specification
EUT Type                   RFID READER
Brand Name                 Zebra
Model Name                 FX9600
FCC ID                  UZ7FX9600
Wireless Technology and
                        RFID : 902.75MHz ~ 927.25MHz
Frequency Range
Mode                    RFID : ASK
Hardware                   0.0.5.0
OS version                 2.2.10.0
Radio Firmware             2.1.2.0
Radio RFBoard              13.0.0.0
MFD                        30SEP17
EUT Stage                    Identical Prototype
Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual
for more detailed description.




3. Maximum RF average output power among production units
                                   Mode                              Average Power (dBm)
                                   RFID                                        30




SPORTON INTERNATIONAL INC.                                                       Page Number        : 5 of 7
TEL : 886-3-327-3456                                                             Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                                             Report Version     : Rev. 01
FCC ID : UZ7FX9600


         RF Exposure Evaluation Report                                                           Report No. : FA751510
4. RF Exposure Limit Introduction
According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of

human exposure to radio frequency (RF) radiation as specified in §1.1310.




    The MPE was calculated at 23 cm to show compliance with the power density limit.
    The following formula was used to calculate the Power Density:


                                                           𝐏𝐆
                                                    𝐒=
                                                          𝟒𝛑𝐑𝟐
    Where:
    S = Power Density
    P = Output Power at Antenna Terminals
    G = Gain of Transmit Antenna (linear gain)
    R = Distance from Transmitting Antenna




SPORTON INTERNATIONAL INC.                                                        Page Number        : 6 of 7
TEL : 886-3-327-3456                                                              Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                                              Report Version     : Rev. 01
FCC ID : UZ7FX9600


         RF Exposure Evaluation Report                                                         Report No. : FA751510
5. Radio Frequency Radiation Exposure Evaluation

5.1. Standalone Power Density Calculation
                                                                                                Power
                                         Antenna Maximum Maximum Maximum Average
                          Frequency                                                           Density at       Limit
          Band                            Gain       Power      EIRP       EIRP       EIRP
                            (MHz)                                                                23cm      (mW/cm^2)
                                          (dBi)      (dBm)     (dBm)        (W)      (mW)
                                                                                             (mW/cm^2)
          RFID               902.75        6.00       30.00    36.000      3.981 3981.072        0.599         0.602
Note: For conservativeness, the lowest frequency of each band is used to determine the MPE limit of that band.




Conclusion:

According to 47 CFR §2.1091, the RF exposure analysis concludes that the RF Exposure is FCC compliant.




SPORTON INTERNATIONAL INC.                                                      Page Number        : 7 of 7
TEL : 886-3-327-3456                                                            Report Issued Date : Oct. 30, 2017
FAX : 886-3-328-4978                                                            Report Version     : Rev. 01
FCC ID : UZ7FX9600



Document Created: 2017-10-31 18:25:22
Document Modified: 2017-10-31 18:25:22

© 2025 FCC.report