RF Exposure

FCC ID: UX6-00001

RF Exposure Info

Download: PDF
FCCID_1634872

                                                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                                                                                                              Application No.: GZEM1112005022RF
                                                                                                                              Page:                             1 of 2
                                                                                                                              FCC ID: UX6-00001



      RF Exposure Compliance Requirement
    1. Standard requirement
                           Systems operating under the provisions of this section shall be operated in a manner that
                           ensures that the public is not exposed to radio frequency energy level in excess limit for
                           maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section
                           2.1091 this device has been defined as a mobile device whereby a distance of 0.2m normally
                           can be maintained between the user and the device.
    (a) Limits for Occupational / Controlled Exposure
                                                    Electric Field                        Magnetic Field                                                                  Averaging Times
       Frequency Range                                                                                                            Power Density
                                                     Strength (E)                           Strength (H)                                                                     ‫׀‬E‫׀‬    2
                                                                                                                                                                                        ,‫׀‬H‫ ׀‬2or S
                   (MHz)                                                                                                             (S)(mW/cm2)
                                                            (V/m)                                  (A/m)
                                                                                                                                                                                 (minutes)
                  0.3-3.0                                     614                                   1.63                                    (100)*                                   6
                   3.0-30                                   1842/f                                 4.89/f                                 (900/f)*                                        6
                  30-300                                     61.4                                  0.163                                      1.0                                         6
                300-1500                                                                                                                    F/300                                         6
            1500-100000                                                                                                                         5                                         6


    (b) Limits for General Population / Uncontrolled Exposure
                                                    Electric Field                        Magnetic Field                                                                  Averaging Times
       Frequency Range                                                                                                            Power Density
                                                     Strength (E)                           Strength (H)                                                                     ‫׀‬E‫׀‬
                                                                                                                                                                                    2
                                                                                                                                                                                        ,‫׀‬H‫ ׀‬2or S
                   (MHz)                                                                                                             (S)(mW/cm2)
                                                            (V/m)                                  (A/m)
                                                                                                                                                                                 (minutes)
                 0.3-1.34                                     614                                   1.63                                    (100)*                                  30
                  1.34-30                                    824/f                                 2.19/f                                 (180/f)*                                       30
                  30-300                                     27.5                                  0.073                                      0.2                                        30
                300-1500                                                                                                                    F/500                                        30
            1500-100000                                                                                                                       1.0                                        30

    Note: f=frequency in MHz; *Plane-wave equivalent power density




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only.


                                                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                                                                                                              Application No.: GZEM1112005022RF
                                                                                                                              Page:                             2 of 2
                                                                                                                              FCC ID: UX6-00001



    2. MPE Calculation Method
                                                             0.5                                                         2        2
                           E (V/m)=(30*P*G) /d                             Power Density: Pd(W/m )=E /377
                           E=Electric Field (V/m)
                           P=Peak RF output Power (W)
                           G=EUT Antenna numeric gain (numeric)
                           d= Separation distance between radiator and human body (m)
                           The formula can be changed to
                           Pd= (30*P*G)/(377*d2)
                           From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as
                           well as the gain of the used antenna, the RF power density can be obtained.


    3. Calculated Result and Limit

    Normal:
                                                               Peak                     Peak                                                    Limit of
                                   Antenna                                                                         Power
       Frequency                                              Output                   Output                                                    Power
                                    Gain                                                                         Density (S)                                                   Test Result
         (MHz)                                                Power                    Power                                                   Density (S)
                                  (Numeric)                                                                      (mW/cm2)
                                                              (dBm)                    (mW)                                                    (mW/cm2)
             2402                        1.0                     5.60                     3.63                     0.00722                               1                      Compliance
             2441                        1.0                     5.43                     3.49                     0.00694                               1                      Compliance
             2480                        1.0                     4.94                     3.12                     0.00623                               1                      Compliance

    EDR:
                                                               Peak                     Peak                                                    Limit of
                                   Antenna                                                                         Power
       Frequency                                              Output                   Output                                                    Power
                                    Gain                                                                         Density (S)                                                   Test Result
         (MHz)                                                Power                    Power                                                   Density (S)
                                  (Numeric)                                                                      (mW/cm2)                               2
                                                              (dBm)                    (mW)                                                    (mW/cm )
             2402                        1.0                     4.95                     3.13                     0.00623                               1                      Compliance
             2441                        1.0                     4.70                     2.95                     0.00587                               1                      Compliance
             2480                        1.0                     3.90                     2.45                     0.00487                               1                      Compliance

Remark: Antenna gain is 0 dBi and Antenna Gain (Numeric) is 1.0




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction
issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s)
are retained for 90 days only.



Document Created: 2012-02-03 10:39:00
Document Modified: 2012-02-03 10:39:00