Test report

FCC ID: UU8-MFC05

Test Report

Download: PDF
FCCID_1948490

                                                            Shenzhen EBO Technology Co., Ltd.

     1-4F, Huafeng Science Park, Xin’an Sixth Road, 82th District, Bao’an,
     Shenzhen, China.
     Telephone: +86-755-29451282,
     Fax: +86-755-22639141
                                                                                             Report No.: FCC13-RTE041802
                                                                                             Page 1 of 19



                                        TEST REPORT
 Applicant:                               Lexibook America
 Address of Applicant:                    C/O NATXIS PRAMEX INTERNATIONAL -NORTH AMERICA 1251
                                          avenue of the Americas 34th floor
 Equipment Under Test (EUT)

   Product Name:                          Tablet

   Model No.:                             MFC410EN

   Trade mark:                            Lexibook

 FCC ID:                                  UU8-MFC05

 Applicable standards:                    FCC CFR Title 47 Part 15 Subpart B:2012

 Date of sample receipt:                  April 08, 2013

 Date of Test:                            April 08-18, 2013

 Date of report issued:                   April 18, 2013

 Test Result :                            PASS *
* In the configuration tested, the EUT complied with the standards specified above.




     Authorized Signature:




                 Kavin Yu
             Laboratory Manager
    This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
    samples of the same product and does not permit the use of the EBO product certification mark. The manufacturer should ensure that
    all products in series production are in conformity with the product sample detailed in this report.
    This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that
    detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of EBO
    International Electrical Approvals or testing done by EBO International Electrical Approvals in connection with, distribution or use of the
    product described in this report must be approved by EBO International Electrical Approvals in writing.
    This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
    or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
    Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90
    days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 2 of 19



2 Version


    Version No.                                 Date                                                Description
            00                             April 18, 2013                                                Original




Prepared by:                                                                     Date:                         April 18, 2013

                                           Project Engineer


Reviewed by:                                                                     Date:                         April 18, 2013

                                                 Reviewer




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                              Shenzhen EBO Technology Co., Ltd.
                                                                                                         Report No.: FCC13-RTE041802
                                                                                                         Page 3 of 19




3 Contents
                                                                                                                                                         Page
1      COVER PAGE ...........................................................................................................................................1

2      VERSION .................................................................................................................................................. 2

3      CONTENTS .............................................................................................................................................. 3

4      TEST SUMMARY ..................................................................................................................................... 4

5      GENERAL INFORMATION...................................................................................................................... 5
    5.1        CLIENT INFORMATION.......................................................................................................................... 5
    5.2        GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.3        TEST MODE AND VOLTAGE .................................................................................................................. 5
    5.4        TEST FACILITY .................................................................................................................................... 6
    5.5        TEST LOCATION .................................................................................................................................. 6
    5.6        DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7
    5.7        DEVIATION FROM STANDARDS ............................................................................................................. 7
    5.8        ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 7
    5.9        OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 7
6      TEST INSTRUMENTS LIST ..................................................................................................................... 8

7      TEST RESULTS AND MEASUREMENT DATA...................................................................................... 9
    7.1        CONDUCTED EMISSIONS ..................................................................................................................... 9
    7.2        RADIATED EMISSION ......................................................................................................................... 12
8      TEST SETUP PHOTO ............................................................................................................................ 18

9      EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 19




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 4 of 19



4 Test Summary
                     Test Item                                        Section in CFR 47                                   Result
Conducted Emission                                                         Part15.107                                      PASS
Radiated Emissions                                                         Part15.109                                      PASS
PASS: The EUT complies with the essential requirements in the standard.




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 5 of 19



5 General Information
5.1 Client Information
        Applicant:                               Lexibook America
        Address of Applicant:                    C/O NATXIS PRAMEX INTERNATIONAL -NORTH AMERICA 1251
                                                 avenue of the Americas 34th floor
        Manufacturer:                            Lexibook America
        Address of Manufacturer                  C/O NATXIS PRAMEX INTERNATIONAL -NORTH AMERICA 1251
                                                 avenue of the Americas 34th floor

5.2 General Description of EUT
        Product Name:                            Tablet
        Model No.:                               MFC410EN
        Operation Frequency:                     2412MHz~2462MHz (802.11b/802.11g/802.11n(H20))
                                                 2422MHz~2452MHz (802.11n(H40))
        Power supply:                            Model No.:SJ-0520-U
                                                 Input: AC 100~240V~50/60Hz 0.5A
                                                 Output: 5.0V, 2.0A
                                                 DC 3.7V Li-ion Battery

5.3 Test mode and voltage
        Test mode:
        PC mode                                  Keep the EUT in Data Transfer with PC mode.
        Test voltage:                            AC 120V/60Hz




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 6 of 19



5.4 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:
      ● CNAS —Registration No.: CNAS L5775
        CNAS has accredited Global United Technology Services Co., Ltd. to ISO/IEC 17025 General Requirements for
        the competence of testing and calibration laboratories (CNAS-CL01 Accreditation Criteria for the Competence of
        Testing and Calibration Laboratories) for the competence in the field of testing.
      ● FCC —Registration No.: 600491
         Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and
         fuly described in a report filed with the (FCC) Federal Communications Commission.
         The acceptance letter from the FCC is maintained in out files. Registration 600491, July 20, 2010.
      ● Industry Canada (IC)
         The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. Has been
         Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
         Registration No.: 9079A-1.

5.5 Test Location
        All tests were performed at:
       Global United Technology Services Co., Ltd.
       Address: 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen,
       China
       Tel: 0755-27798480
       Fax: 0755-27798960




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 7 of 19



5.6 Description of Support Units
      Manufacturer                   Description                      Model                   Serial Number               FCC ID/DoC

             HP                         Printer                      CB495A                      05257893                       DoC
          Lenovo                       PC Host                        M6900                    EA05257893                       DoC
           DELL                       MONITOR                       E178FPC                          N/A                        DoC
           DELL                     KEYBOARD                         SK-8115                         N/A                        DoC
           DELL                        MOUSE                        MOC5UO                           N/A                        DoC

5.7 Deviation from Standards
        Biconical, log.per. antenna and horn antenna were used instead of dipole antenna.
        Semi-anechoic Chamber was used as alternation of open air test sites, and all test suites were
        performed with radiated method in it.

5.8 Abnormalities from Standard Conditions
        None.

5.9 Other Information Requested by the Customer
        None.




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 8 of 19




6      Test Instruments list
Radiated Emission:
                                                                                               Inventory         Cal.Date          Cal.Due date
Item        Test Equipment                 Manufacturer                 Model No.
                                                                                                  No.           (mm-dd-yy)         (mm-dd-yy)
          3m Semi- Anechoic
 1                                     ZhongYu Electron          9.2(L)*6.2(W)* 6.4(H)         GTS250          Mar. 29 2013        Mar. 28 2015
              Chamber
 2          Control Room    ZhongYu Electron 6.2(L)*2.5(W)* 2.4(H)                             GTS251               N/A                 N/A
 3        EMI Test Receiver Rohde & Schwarz         ESU26                                      GTS203          Jul. 03 2012        Jul. 02 2013
                            SCHWARZBECK
 4    BiConiLog Antenna                           VULB9163                                     GTS214          Feb. 24 2013        Feb. 23 2014
                           MESS-ELEKTRONIK
   Double -ridged waveguide SCHWARZBECK
 5                                                9120D-829                                     GTS208         Mar. 09 2013        Mar. 08 2014
              horn         MESS-ELEKTRONIK
 6  Amplifier(100kHz-3GHz)        HP                8347A                                      GTS204          Jul. 03 2012        Jul. 02 2013
 7  Amplifier(2GHz-20GHz)         HP                8349B                                      GTS206          Jul. 03 2012        Jul. 02 2013
 8    EMI Test Software         AUDIX                  E3                                       N/A                 N/A                 N/A
 9       Coaxial cable           GTS                  N/A                                      GTS210          Jul. 03 2012        Jul. 02 2013
10      Coaxial Cable            GTS                  N/A                                      GTS211          Jul. 03 2012        Jul. 02 2013
11      Thermo meter              KTJ               TA328                                      GTS256          Jul. 06 2012        Jul. 05 2013


Conducted Emission
                                                                                               Inventory         Cal.Date          Cal.Due date
Item        Test Equipment                 Manufacturer                 Model No.
                                                                                                  No.           (mm-dd-yy)          (mm-dd-yy)
 1         Shielding Room             ZhongYu Electron 7.0(L)x3.0(W)x3.0(H)                    GTS252          Sep. 08 2011        Sep. 07 2013
 2        EMI Test Receiver           Rohde & Schwarz        ESCS30                            GTS223          Jul. 03 2012        Jul. 02 2013
 3        10dB Pulse Limita           Rohde & Schwarz           N/A                            GTS224          Jul. 03 2012        Jul. 02 2013
 4         Coaxial Switch             ANRITSU CORP            MP59B                            GTS225          Jul. 03 2012        Jul. 02 2013
                                      SCHWARZBECK
 5                LISN                                      NSLK 8127                          GTS226          Jul. 03 2012        Jul. 02 2013
                                     MESS-ELEKTRONIK
 6         Coaxial Cable                   GTS                  N/A                            GTS227          Jul. 03 2012        Jul. 02 2013
 7        EMI Test Software               AUDIX                 E3                              N/A                 N/A                 N/A
 8         Thermo meter                     KTJ               TA328                            GTS233          Jul. 03 2012        Jul. 02 2013



General used equipment:
                                                                                              Inventory          Cal.Date          Cal.Due date
Item      Test Equipment               Manufacturer                   Model No.
                                                                                                  No.          (dd-mm-yy)           (dd-mm-yy)
 1           Barometer                 ChangChun                        DYM3                  GTS257          July 10 2012         July 09 2013




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 9 of 19



7 Test Results and Measurement Data
7.1 Conducted Emissions
        Test Requirement:                     FCC Part15 B Section 15.107
        Test Method:                          ANSI C63.4:2003
        Test Frequency Range:                 150kHz to 30MHz
        Class / Severity:                     Class B
        Receiver setup:                       RBW=9kHz, VBW=30kHz
        Limit:                                                                                Limit (dBµV)
                                                  Frequency range (MHz)
                                                                                  Quasi-peak               Average
                                                         0.15-0.5                   66 to 56*              56 to 46*
                                                           0.5-5                       56                     46
                                                          0.5-30                       60                     50
        Test procedure                        The E.U.T and simulators are connected to the main power through a
                                              line impedance stabilization network(L.I.S.N.). The provide a
                                              50ohm/50uH coupling impedance for the measuring equipment. The
                                              peripheral devices are also connected to the main power through a LISN
                                              that provides a 50ohm/50uH coupling impedance with 50ohm
                                              termination. (Please refers to the block diagram of the test setup and
                                              photographs). Both sides of A.C. line are checked for maximum
                                              conducted interference. In order to find the maximum emission, the
                                              relative positions of equipment and all of the interface cables must be
                                              changed according to ANSI C63.4: 2003 on conducted measurement.
        Test setup:




        Test environment:                     Temp.:          25 °C            Humid.:         52%            Press.:        1 012mbar
        Measurement Record:                                                                                   Uncertainty: ± 3.45dB
        Test Instruments:                      Refer to section 6 for details
        Test mode:                            Refer to section 5.3 for details
        Test results:                          Pass


Measurement Data


“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 10 of 19


Line:




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 11 of 19



Neutral:




    Notes:
    1. An initial pre-scan was performed on the line and neutral lines with peak detector.
    2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak
        emission.
    3. Final Level =Receiver Read level + LISN Factor + Cable Loss
    4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to
        meet both limits and measurement with the average detector receiver is unnecessary.




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 12 of 19



7.2 Radiated Emission
        Test Requirement:                     FCC Part15 B Section 15.109
        Test Method:                          ANSI C63.4:2003
        Test Frequency Range:                 30MHz to 8GHz
        Test site:                             Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:
                                                  Frequency             Detector            RBW           VBW                 Remark
                                                   30MHz-             Quasi-peak          100KHz         300KHz        Quasi-peak Value
                                                    1GHz
                                                                          Peak             1MHz           3MHz             Peak Value
                                                Above 1GHz
                                                                          Peak             1MHz           10Hz           Average Value

        Limit:
                                                          Frequency                    Limit (dBuV/m @3m)                     Remark
                                                       30MHz-88MHz                                40.0                 Quasi-peak Value
                                                      88MHz-216MHz                                43.5                 Quasi-peak Value
                                                     216MHz-960MHz                                46.0                 Quasi-peak Value
                                                       960MHz-1GHz                                54.0                 Quasi-peak Value
                                                                                                  54.0                   Average Value
                                                         Above 1GHz
                                                                                                  74.0                     Peak Value
        Test Procedure:                       1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                                 ground at a 3 meter camber. The table was rotated 360 degrees to
                                                 determine the position of the highest radiation.
                                              2. The EUT was set 3 meters away from the interference-receiving
                                                 antenna, which was mounted on the top of a variable-height antenna
                                                 tower.
                                              3. The antenna height is varied from one meter to four meters above the
                                                 ground to determine the maximum value of the field strength. Both
                                                 horizontal and vertical polarizations of the antenna are set to make the
                                                 measurement.
                                              4. For each suspected emission, the EUT was arranged to its worst case
                                                 and then the antenna was tuned to heights from 1 meter to 4 meters
                                                 and the rota table was turned from 0 degrees to 360 degrees to find the
                                                 maximum reading.
                                              5. The test-receiver system was set to Peak Detect Function and Specified
                                                 Bandwidth with Maximum Hold Mode.
                                               6. If the emission level of the EUT in peak mode was 10dB lower than the
                                                  limit specified, then testing could be stopped and the peak values of the
                                                  EUT would be reported. Otherwise the emissions that did not have

“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 13 of 19

                                                  10dB margin would be re-tested one by one using peak, quasi-peak or
                                                  average method as specified and then reported in a data sheet.
        Test setup:                           Below 1GHz




                                              Above 1GHz




        Test environment:                     Temp.:          25 °C            Humid.:           52%             Press.:       1 012mbar
        Measurement Record:                                                                                       Uncertainty: ± 4.5dB
        Test Instruments:                      Refer to section 6 for details
        Test mode:                            Refer to section 5.3 for details
        Test results:                          Pass


Note:
The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
equation with a sample calculation is as follows:

Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor

“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 14 of 19



Measurement Data
Below 1GHz
Horizontal:




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 15 of 19



Vertical:




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 16 of 19



Above 1GHz
Horizontal:




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”


                                                       Shenzhen EBO Technology Co., Ltd.
                                                                                            Report No.: FCC13-RTE041802
                                                                                            Page 17 of 19


Vertical:




“This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
http://www.ebotek.cn and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
http://www.ebotek.cn. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of
this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the
limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a
transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in
full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test
report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.”



Document Created: 2013-04-19 11:57:08
Document Modified: 2013-04-19 11:57:08

© 2024 FCC.report