Ins-30060-US            Long range reader

Technical Support
                 1 800 672 PAXT                               support@paxton.co.uk
             Technical help is available:   Monday - Friday from 5am - 11pm PST / 8am - 2am EST
                                             Saturday from 7am - 11am PST / 10am - 2pm EST
			
 Documentation on all Paxton Access products can be found on our web site - http://www.paxton-access.com/


  What is Hands Free?
  A long range reader can read Paxton hands free tokens up to a maximum of 5 yards. The system comprises of a
  long range reader with an integral hands free interface and hands free tokens (keycard or keyfob). The system
  operates by using the field being transmitted by the reader to wake up the token which then communicates with
  the interface.

  Existing Switch2 or Net2 control units, can be used without modification. Standard Paxton tokens/keyfobs can
  be used with this reader but at their normal read range (see table on back page)

  Hands free tokens also include a standard proximity ID chip and can therefore be presented to any Paxton


   Layout




LED indications
  The unit has a single high intensity LED array that displays RED or GREEN indications.

  Steady RED -      Waiting for card ( IDLE state )
  Flashing GREEN - Access Granted ( or held unlocked )
  Flashing RED -    User Access Denied

  If an error condition exists ( ACU powered off, Cable break, etc) the LED will show a steady RED indication.


Before you install
Positioning readers

  Readers should not positioned so that their active fields overlap.
  (see table on back page for typical hand free read ranges)

  For maximum read range the Hands Free reader field should not be
  overlapped by the field from other interference sources at or around 125KHz.
  These include Loop readers, non Paxton readers, etc.
 For optimum keyfob battery life please choose your reader location carefully to avoid placing it within hands free
 range of work stations, rest or smoking areas.




Read in, read out
 When using in and out readers, users may be picked up by both readers as they move through the door which
 will effect the reliability of any Roll Call or Antipassback application. Ensure that sufficient spacing is provided
 between these readers for optimum range and reliability.
 NOTE: Each long range reader requires a dedicated ACU reader port.




Wiring




                                                                                                                                                                                                                                      Net2Air Interface
                                                                                         Black/White
                                    Orange
                                                       Yellow
                                                                             Brown


                                                                                                        Mauve
                                                                                                                Blue

                                                                                                                                  Yellow
                                                                                                                                            Green

                                                                                                                                                          Orange
                                                                                                                                                                   Brown
                                                                                                                                                                           Red




                                                                                                                                                                                                      Not Connected         Entry                                                                           Entry
                                                                                                                                                                                                                                                                                                                     Not Connected
                                                                                                                                                                                                                               0V                                                                              0V
                Red 12v dc                   Keypad 2                                                                       Reader 2                                                         +12V
                                                                                                                                                                                 Power




                                                                                                                                                                                                                                     Net2 Control Unit




                Brown                                                                                                                                                                           0V
                                                                                                                                                                                                                      Media Detect                                                                    Media Detect
                                                                                                   z-14401



                                                                                                                  TestID: 012345678901


                                                                                                                                              241821
                                                                                                                                              Seriel number




                Orange                                                                                                                                                                        N.C.-                     Clock/D1                                                                        Clock/D1
                                                Caution: For 12V d.c readers only. For
                                                connection of old 5v readers, refer to




                                                                                                                                                                                 Relay 1
                                  Reader 1




                                                                                                                                                                                                                                                                                             Reader




                Green                                                                                                                                                                         N.O.-                      Data/D0                                                                         Data/D0

                Yellow                                                                                                                                                                        Com                     Green LED                                                                       Green LED
                Blue                                                                                                                                                                          N.C.-
                                                                                                                                                                                                                      Amber LED                                                                       Amber LED
                                                                                                                                                                                 Relay 2




                Mauve                                                                                                                                                                         N.O.-
                                                                                                                                                    3




                                                                                                                                                                                                                         Red LED                                                                         Red LED
                Black/White                                                                                                                                                                   Com
                                                                                                                                                    24898 00000
                                                instructions




                                                                                                                                                                                 Alarm Output                                                                                                                                         Not Connected
                                                                                                                                                                                                                              12v                                                                             12v
                Brown
                                   Keypad1




                                                                                                                                                                                                                                                                           Green LED
                                                                                                                                                                                                                                                              Exit/Entry




                Yellow                                                                                                                                                                          0V
                                                                                                                                                                                                                                                                                       12V
                                                                                                                                                                                                                                                         0V




                Orange                                                                                                                                                                     Contact
                Screen or spare cores
                                                                                                                                                                                                0V
                                                                                                                                                    4




                from network cable
                                                                                                                                                                             Inputs




                1     White/Green                                                                                                                                                              Exit
                                              CAT5 Cable coding
                                                                  Networkj




                2     Green                                                                                                                                                                     0V
                3     White/Orange                                                                                                                                                          Tamper
                4     Orange                                                                                                                                                                  PSU
                                                                             Relay 1
                                                                                         Relay 2

                                                                                                         Exit

                                                                                                                Contact
                                                                                                                                   Tamper
                                                                                                                                            PSU
                                                                                                                                                          OK
                                                                                                                                                                   5V
                                                                                                                                                                           12V
                                   RX
                                                     TX




                                                                                                                                                                                                                                                                                                                       12Vdc
                                                                                                                                                                                                                                                                                                                       Power Supply




To achieve the maximum range for the device, the interface PCB has been mounted upside down to position the
internal aerial away from other reader components.




 A data cable must be run from the control unit to the reader interface. The recommended cable for this is Belden
 9540; a 10 core overall screened cable with a maximum cable length of 100 yards. Spare cores should be used
 to double up on the power wires (Red/Black) to the interface.

 The reader requires a higher current (up to 1A) than can be supplied by the ACU reader port and so an
 independent 12V DC power feed must be provided. As per the wiring diagram, the spare outputs on the Paxton
 2A boxed power supply can be used for this purpose.

It is important to run an appropriate power cable to the reader that is capable of carrying a current of 1A.


Fitting




                                             11                                                              22




                                                  33                                                           4
                                                                                                               4


The long range reader consists of a reader module mounted inside the front half of the housing and a hands free
interface mounted inside the rear half. An interconnect cable is supplied that connects the two sections together.

Two 5 yard cables for data and power are provided. These enter the module at the rear through two compression
glands. If longer cables are required, refer to the previous section for further details.

Determine the position of the reader and mark and drill holes for the fixing screws and cable access.

Fix the mounting plate to the post with the locating hooks at the top. (Fig 1)

Feed the cables for power and data thorough the mounting plate and into the rear section of the reader leaving
enough slack to allow easy connection to the circuit boards later in the installation.

Tighten the weatherproof cable glands at the rear of the reader. (Fig 2)

Hang the rear reader section on the mounting plate and secure with two screws. (Fig 3)

Complete the wiring of the reader as shown in this instruction.

Join the front section to the rear section with the Allen screws provided. (Fig 4)

NOTE: It may be necessary to briefly remove the reader from its mounting plate if access to the Allen screws is
limited by the post or wall.


      Configuration


  Changing frequency channel

  If you are experiencing problems with the range or reliability this may be due to poor reader positioning, adjacent
  interfering 125KHz or 2.4 GHz equipment, e.g. an adjacent wireless PC network. Please refer to the ‘Before you
  install’ information regarding unit locations. If you are still unable to improve the system performance then you
  may try an alternative 2.4 GHz channel using Switch 1. Power cycle the unit after any changes.

  The system has 16 different channels available. The unit is set to channel 4 as this frequency is normally clear of
  other device transmissions. This can be changed using a small flat blade screwdriver. Take care not to contact the
  circuit board with the screwdriver blade as this may damage components.


                                                                        Switch                         IEEE 802.15.4
SW2                                                                     position             GHz
                                                                                                          channel
                                                                            0                2.405           11
                                                                            1                2.41            12
                                                                            2                2.415           13
                                                                            3                2.42            14
                                                                            4                2.425           15
                                                                            5                2.43            16
                                                                            6                2.435           17
                                                                            7                2.44            18
                                                                            8                2.445           19
                                                                            9                2.45            20
                                                                            A                2.455           21
                                                                            B                2.46            22
                                                                            C                2.465           23
                                                                            D                2.47            24
                                                                            E                2.475           25
                                                                            F                2.48            26



                                                                          SW1. Rotate the switch to select an
                                                                                   alternate channel.
                                                                         The switch should initially be set to the
  All hands free tokens automatically configure themselves to use                  default position ‘4’
  the new channel. No configuration of the token is required.



  Keycard configuration

  The switch SW2 is used to select which button on a Keycard is active for this interface.

  The unit must be power cycled if the switch position is changed to reconfigure the settings.

  Please refer to instruction sheet ins-30037-US for switch configuration supplied with the keycard.


Using an entry confirmation button

Where two door readers may pick up the same hands free token, a push to make button can be used to confirm
an entry request for the specific door. Where fitted, the button LED will flash for 5 seconds after the hands free
token has been recognised and must be pressed to unlock the door.
To enable the use of an entry confirmation button do the following steps:

1. Power down the interface board
2. Power up the interface board
3. Press and hold the entry confirmation button for a minumum of 3 seconds within 60 seconds of power up.

To disable the use of the button repeat the above process.




                                                 Specifications
        Electrical                                           Min                   Max
   Voltage                                               11V DC                 14V DC
   Current                                                                          1A
   Additional power supply required                                                                      Yes
   Carrier frequency                                     119 kHz                140 kHz
                                                        2.405 GHz              2.480 GHz
   Clock and data bit period                                                                           600 µs
        System Specification                                 Min                    Max
   Button confirmation input                                                                             Yes
   Cable type for extensions                                                                         Belden 9540
   Cable length between ACU and reader                                          100 yds
        Read Range                                        Token                 Keyfob                Watchprox
   Long range reader                                      3 inch               1   1/2   inch          1/2   inch

        Read range with Hands Free token                     Min                    Max

   Long range reader                                                               16 ft
   P200E metal mount                                                                6 ft
  P200                                                                              8 ft
  P75                                                                               5 ft
  P50                                                                               4 ft
  P38                                                                               3 ft
         Environment                                         Min                    Max
   Operating temperature                                 - 20 °C                + 55 °C
   Waterproof                                                                                        Outdoor Use
        Dimensions                                        Width                 Height                  Depth
                                                        8 1/2 inch             8 1/2 inch             4 3/4 inch



  FCC Compliance
  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
  device may not cause harmful interference, and (2) this device must accept any interference received, including
  interference that may cause undesired operation.

  Changes or modifications not expressly approved by the party responsible for compliance
  could void the user’s authority to operate the equipment.



Document Created: 2008-02-08 16:19:44
Document Modified: 2008-02-08 16:19:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC