User manual_07-0002 HF3000-Series Install Manual.v.5.pdf

FCC ID: UQYHF3000

Users Manual

Download: PDF
FCCID_4180751

                                                                                                                                                                 Doc. No. Revision

                                          HF3000-Series Installation Manual                                                                                       07-0002 Rev.3

                                                                                                                                                                     Page 1 of 14



                                                            HF3000-Series Installation Manual

Contents
1 Purpose .............................................................................................................................................................................. 2
2 Scope .................................................................................................................................................................................. 2
3 Reference Documents ........................................................................................................................................................ 2
4 Product Specification: ........................................................................................................................................................ 2
5 Responsibility ..................................................................................................................................................................... 3
6 Work Safety ........................................................................................................................................................................ 3
7 Unpacking and Transport ................................................................................................................................................... 4
   7.1 Unpacking the HF3000 .................................................................................................................................................. 4
   7.2 Cabinet and Shelf Transportation ................................................................................................................................. 5
8 Cabinet and Shelf Installation Process ............................................................................................................................... 7
   8.1 Cabinet Installation ....................................................................................................................................................... 7
   8.2 Shelf installation............................................................................................................................................................ 8
   8.3 Shelf Removal................................................................................................................................................................ 9
9 Cabinet Wall Securing Process ......................................................................................................................................... 10
   9.1 Directions for installing with Screw Inserts................................................................................................................. 10
   9.2 Directions for installing with Expanding Inserts. ........................................................................................................ 10
10 Cabinet Servicing Process ................................................................................................................................................ 12
11 Cabinet Cleaning Process ................................................................................................................................................. 12
   11.1 Cleaning with a detergent ......................................................................................................................................... 12
   11.2 Cleaning with wipes .................................................................................................................................................. 12
12 Appendix .......................................................................................................................................................................... 13
      Appendix 1: Notice of FCC Compliance .......................................................................................................................... 13
      Appendix 2: Notice of Industrie Canada Compliance ..................................................................................................... 13
13 Revision History................................................................................................................................................................ 14




      © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                                  trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                           Doc. No. Revision

                              HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                              Page 2 of 14




1 PURPOSE
      This procedure describes the specifications, installation steps, and regulatory information for
      the HF3000-series SmartCabinet.

2 SCOPE
      This procedure applies to installation of HF3000-series SmartCabinets

3 REFERENCE DOCUMENTS
      None

4 PRODUCT SPECIFICATION:
      Power Brick                100-240 VAC, 1.5A Max, 50-60 Hz, power supply is rated to IEC/EN/UL-62368-1
                                 and IEC/EN/UL-60601-1 (medical grade).

      Cabinet Power              12.5V DC, 7.2A

      AC Cable                   The cabinet is supplied with a power cable.

      Fuse                       None

      Environment                Operating environment between 50 and 90 degrees F (10C – 32C), non-
                                 condensing; must be installed in an environment free of corrosive agents and
                                 excessive dust

      Size                       78 inches high by 36 inches wide by 27 inches deep

      Weight                             Weight in lbs.                 Without Doors         With Doors
                                   Base Cabinet with 2 shelves               160                 220
                                   Cabinet with 3 shelves                    175                 235
                                   Cabinet with 4 shelves                    190                 250
                                   Cabinet with 5 shelves                    205                 265
                                   Cabinet with 6 shelves                    220                 280
                                   Cabinet with 7 shelves                    235                 295
                                   Cabinet with 8 shelves                    250                 310
                                   Cabinet with 9 shelves                    265                 325
                                   Cabinet with 10 shelves                   280                 340
                                   Cabinet with 11 shelves                   295                 355

      Weight Capacity            The weight capacity of each shelf if 25 lbs.

      Network                    Auto-select 10/100Mbps Ethernet



  © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                              trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                           Doc. No. Revision

                              HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                              Page 3 of 14




5 RESPONSIBILITY
        Activity                                                                                            Responsible Party
        Shipping                                                                                            WaveMark
        Receiving                                                                                           Customer
        Unpacking                                                                                           Customer
        Moving Cabinet and Shelves from Receiving to Department                                             Customer
        Training on shelf installation and shelf movement                                                   WaveMark
        Shelf Installation                                                                                  Customer
        Placing Inventory on shelves                                                                        Customer
        Connecting cabinet to power and Ethernet                                                            Customer
        Installing wall bracket                                                                             Customer


6 WORK SAFETY

      It is our highest priority that all field installations comply with the company’s installation and safety
      procedures and any safety procedures in place at the location of installation.

                     In order to assure that equipment is installed in a safe manner and in compliance
                     with installation guidelines only trained personnel are authorized to activate or
                     service cabinets. This product contains no user-serviceable components.




  © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                              trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                           Doc. No. Revision

                              HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                              Page 4 of 14




7 UNPACKING AND TRANSPORT
       NOTE: Two people are required to move the cabinet from the shipping container to its final location.
             Cabinet contains sensitive electronic components. Take care in moving the cabinet from the
             shipping container.



  7.1 Unpacking the HF3000
        Step 1        Prior to unpacking the cabinets, inspect all packing for shipping damage. Take pictures of
                      any observed damage and immediately report to WaveMark Customer Support toll free at
                      877.492.8362 or email support@wavemark.com. Include all relevant pictures, a brief
                      description of damage, as well as cabinet serial number.
                      Note: Side marked “Ramp” must be facing out with 10ft (3 meters) of clearance to
                            accommodate ramp and cabinet unloading.
        Step 2        Cut and remove strapping. Remove outer layers of packaging and discard. Be careful not
                      to damage the cabinet when cutting the packaging.
        Step 3        Lower ramp:
                          1. Remove packing foam from ramp.
                          2. Lift the wooden ramp out of the groove and position ramp by inserting pin on the
                             ramp into the hole on the pallet. The edge of the ramp should sit flat against the
                             crate edge.




        Step 4        With one person holding each side of the cabinet, guide cabinet down the ramp to the floor.

        Step 5        Inspect the cabinet for damage. Take pictures of observed damage and immediately
                      report to WaveMark Customer Support toll free at 877.492.8362 or email
                      support@wavemark.com. Include all relevant pictures, a brief description of damage, as
                      well as cabinet serial number.
                      Don’t proceed with the installation of any damaged cabinet.

        Step 6        If required, clean the cabinet exterior following procedure in Section 11.




  © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                              trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                         Doc. No. Revision

                            HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                            Page 5 of 14



7.2 Cabinet and Shelf Transportation

       Step 1         Identify cabinet location and locate nearest electrical outlet and network jack.
                      Confirm that the cabinet location is free from airborne corrosive agents, excessive dust or
                      dripping water. The floor should be level and dry

       Step 2         Before moving a cabinet to its location, walk the route to identify obstructions such as signs,
                      door frames, or flooring issues such as elevator thresholds that might be a problem for the
                      cabinet wheels.
                                 The cabinet is designed to be rolled over smooth flooring; the cabinet should never
                                 be tilted, placed on its side, or rolled across parking lots.

       Step 3         Except for the top and bottom shelves, cabinet shelves will be shipped separately from the
                      cabinet. Remove shelves from their shipping containers and carefully place on the bottom
                      shelf for transport.
                      Shelves should first be placed vertically and then tilted gently to create points of contact with
                      both side walls. This reduces the risk of the shelves being damaged during transport inside
                      the hospital facility.




© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                            trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                         Doc. No. Revision

                            HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                            Page 6 of 14



                      While not necessary, packing foam and bags can be used for added safety during
                      transport.




                       To avoid injury and/or damage to equipment during cabinet transport,
                       follow these safety precautions:
                        Do not place more than 10 shelves inside a cabinet.
                          Do not use the cabinet to transport any other materials (e.g. RFID tags, point of use
                           stations, box readers, etc.) as it may damage the cabinet or materials and will void
                           warranty.
                          Do not transport shelves in the following orientations. This will increase the risk of injury
                           or damage to the shelves.




       Step 4         Move the cabinet with shelves to its final location by pushing/pulling only the lower half of
                      the cabinet. Move the cabinet safely to avoid objects and people who may be traveling in the
                      same corridors.
                      The cabinet is designed to be very stable but moving too quickly and pushing against the top
                      of the cabinet may cause it to tip.



© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                            trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                           Doc. No. Revision

                              HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                              Page 7 of 14



                                   When entering and exiting elevators, the cabinet’s wheels may lodge in the
                                   elevator door gap. If this happens, gently move the cabinet from side to side and
                                   pull/push to dislodge it. DO NOT USE EXCESSIVE FORCE!


CABINET AND SHELF INSTALLATION PROCESS

  8.1 Cabinet Installation
         Step 1         Locate power and network cables shipped with the cabinet and remove all packaging
                        and safety covers.

         Step 2         The cabinet network and power connections are located in the base of the cabinet back
                        panel near the floor.




         Step 3         Connect the DC power cable (attached to the power brick) to the cabinet and twist the
                        connector until secure. This requires several full turn twists until completely tightened.
                        Connect the electrical AC cable to the power brick.

         Step 4         Connect network cable to the back of the cabinet next to the power connector.

         Step 5         Tuck power brick into the cavity as shown below:




  © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                              trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                         Doc. No. Revision

                            HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                            Page 8 of 14




       Step 6         Connect network cable to network port on wall, and connect AC power cord to an
                      electrical outlet on wall. The wall outlet must be easily accessible.
                      NOTE: If the network cable is not long enough, obtain a longer straight-thru network
                      cable (a crossover cable will not work). In the final installation the network cable should
                      not be under physical stress and should not be resting against electrical equipment such
                      as motors or heating units.
                      When successfully connected, the cabinet shelf illumination lights, shelf indicator LEDs,
                      and eBox LEDs will turn on in about one minute. The cabinet is now ready for
                      configuration.
                      If this does not occur and power/network connections and sources are confirmed to be
                      correct and live, contact WaveMark Customer Support via phone at 877.492.8362 or via
                      email at support@wavemark.com

        Step 7        Place cabinet into its final position.


        Step 8        Secure cabinet to the wall with the included mounting hardware. See Section 9 for more
                      information.


8.2 Shelf installation

       NOTE: Only trained technicians should install or adjust shelf location.
             The bottom and top shelves must remain in place and should not be moved.

      Step 1       Stabilize cabinet against a wall or equivalent.
                   Note: If this is the initial installation, remove shelves transported in cabinet and set aside.

      Step 2       Use the allen wrench provided with the cabinet to remove the end corner caps by removing
                   the four screws from each corner cap. Set corner caps aside in a manner that will prevent
                   them from falling over.

      Step 3       Insert Shelf:
                    1. Orient shelf so the red receptacle is facing out towards front of cabinet and on the right
                       to be closest to the red network cables.
                    2. Place shelf in the desired location ensuring that it is aligned in the same numbered
                       track on each side of the cabinet. Shelf center-to-center spacing should not be less
                       than 6.5”.
                    3. Push shelf toward the back of the cabinet until secure.




© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                            trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                         Doc. No. Revision

                            HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                            Page 9 of 14




      Step 4       Insert nearest red cable into the red receptacle on the front-right of each shelf. Repeat
                   steps 3 and 4 for additional shelves.

      Step 5       Secure all unused network connectors and excess cables are secured in the cable
                   chase. Be sure that cables are not twisted or crossed.




      Step 6       Replace end covers and secure with the screws. The cabinet is now ready for final
                   configuration. If cabinet was previously configured the cabinet will resume normal
                   inventory cycle counting.



8.3 Shelf Removal
      Step 1       Stabilize cabinet against a wall or equivalent.

      Step 2       Use the allen wrench provided with the cabinet to remove the end corner caps by removing
                   the four screws from each corner cap. Set corner caps aside in a manner that will prevent
                   them from falling over.

      Step 3       Unplug red cable from shelf to be removed.

      Step 3       Slide shelf out and set aside.




© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                            trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                           Doc. No. Revision

                              HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                             Page 10 of 14




8 CABINET WALL SECURING PROCESS

                Safety Warning: The HF3000-series must be secured to a wall to provide
                stability and prevent personal injury from tipping. Hospital personnel must
                secure cabinet using appropriate hardware.



  9.1 Directions for installing with Screw Inserts.
        Step 1       Place a mark on the wall 79” from the floor at the point that will be the center of the cabinet.

        Step 2       Place bottom edge of bracket on the mark.

        Step 3       Place a mark in the center of the 2 holes.

        Step 4       Drill approximately 1 ½” deep using a ¼” drill where you placed the marks indicating the center
                     of the holes.
                                  Prior to drilling the hole, ensure that the wall can accommodate the bracket. Confirm
                                  with the appropriate authorities that the target section of the wall may be drilled,
                                  penetrated, and can support hardware without adverse impact on safety, health or
                                  operating environment.

        Step 5       Remove screws from plastic inserts and tap the plastic inserts into drilled hole until the flanges
                     are flush with the wall.

        Step 6       Place the bracket in place and insert the screws. Tighten the screws only tight enough to hold
                     the bracket in place until the cabinet is in place.

        Step 7       Position cabinet so it interfaces with bracket and tighten screws.


  9.2 Directions for installing with Expanding Inserts.
        Step 1       Place a mark on the wall 79” from the floor at the point that will be the center of the cabinet.

        Step 2       Place bottom edge of bracket on the mark.

        Step 3       Place a mark in the center of the 2 holes.

        Step 4       Drill approximately 1 ½” deep using a ¼” drill where you placed the marks indicating the
                     center of the holes.
                                  Prior to drilling the hole, ensure that the wall can accommodate the bracket.
                                  Confirm with the appropriate authorities that the target section of the wall may be
                                  drilled, penetrated, and can support hardware without adverse impact on safety,
                                  health or operating environment.




  © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                              trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                         Doc. No. Revision

                            HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                           Page 11 of 14




      Step 5       Remove screws from plastic inserts and tap the plastic inserts into drilled hole until the
                   flanges are flush with the wall.
      Step 6       Place the expanding inserts in the holes. Tighten the screws until the inserts are snug.
                   Remove screws from the inserts.

      Step 7       Hold the bracket in position and insert screws back into the inserts. Tighten the screws
                   enough to hold the bracket in place until the cabinet is in position.
      Step 8       Position cabinet so it interfaces with bracket and tighten screws.

     Illustrations for mounting bracket and securing cabinet:




© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                            trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                           Doc. No. Revision

                              HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                             Page 12 of 14




9 CABINET SERVICING PROCESS

  The cabinet must be serviced only by trained service personnel.


10 CABINET CLEANING PROCESS

  11.1 Cleaning with a detergent

           Mix a mild detergent solution such as 1:100 dilution of Alconox, Liquinox, or other mild
           detergent. Isopropyl Alcohol is an acceptable alternative. Quaternary Ammonium (Quat) is
           also an acceptable alternative. Do not use Sodium Hypochlorite or other bleach solutions as
           they could oxidize stainless steel and other electronic parts.



  11.2 Cleaning with wipes

           Clean all surfaces by spraying liberally with the cleaning solution and wiping down with
           general purpose wipes. Wipe dry with general purpose wipes. Dispose of wipes in
           accordance with local and hospital regulations.

                           To clean under the cabinet, carefully move the cabinet (disconnect wall-mount
                           hardware, unplug the cabinet, then roll cabinet away from its location).




  © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                              trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                               Doc. No. Revision

                                  HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                                 Page 13 of 14




11 APPENDIX

 Appendix 1: Notice of FCC Compliance
  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
  Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
  interference when the equipment is operated in a commercial environment. This equipment generates, uses,
  and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
  manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
  area is likely to cause harmful interference in which case the user will be required to correct the interference
  at his/her own expense.

  Changes or modifications not expressly approved by Cardinal Health could void the user’s authority to operate
  the equipment.

  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
  this device may not cause harmful interference, and (2) this device must accept any interference received,
  including interference that may cause undesired operation.

  This product must be professionally activated by Cardinal Health/ WaveMark trained personnel and must only
  be serviced by Cardinal Health/ WaveMark trained service personnel.


 Appendix 2: Notice of Industrie Canada Compliance
  Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this
  device must accept any interference, including interference that may cause undesired operation of the device.

  .

  This device has been designed to operate with the antennas listed below and having a maximum gain of 0
  dB. Antennas not included in this list are strictly prohibited for use with this device. Acceptable antenna is
  Cardinal Health part number 04-0175-R.

  To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that
  the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful
  communication.



  Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer
  d’interférences et (2) cet appareil doit accepter toute 13ause1313rence, y compris les 13ause1313rences
  pouvant provoquer un fonctionnement indésirable de l’appareil..

  Cet appareil a été conçu pour fonctionner avec les antennes énumérées ci-dessous et ayant un gain
  maximal de 0 dB. Les antennes ne figurant pas dans cette liste sont strictement interdites d’utilisation avec
  cet appareil. L’antenne acceptable est la pièce numéro 04-0175-R de Cardinal Health.



      © 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and ESSENTIAL TO CARE are trademarks or registered
                                  trademarks of Cardinal Health. All other marks are the property of their respective owners.


                                                                                                                              Doc. No. Revision

                                 HF3000-Series Installation Manual                                                             07-0002 Rev.3

                                                                                                                                Page 14 of 14




  Pour réduire le 14ause14 de brouillage radioélectrique 14ause aux autres utilisateurs, le type d’antenne et
  son gain doivent être choisis de manière à ce que la puissance rayonnée isotrope équivalente (par
  exemple) ne soit pas supérieure à celle autorisée pour une communication réussie.


12 REVISION HISTORY

Rev.           Date             Reviewer             Description of the Revision                                                 Change No.
                                   Lars
 1        12.12.2018                      New Document                                                                                  NA
                                Rohrberg
                                   Rich
 3         1.30.2019                      Updates, change-bars activated                                                                NA
                               Leitermann
 4         2.20.2019           Bob Quinn Updates                                                                                        N/A