Test report_ES2787-1 FCC 15.225 Final Report rev3.pdf

FCC ID: UQYHF3000

Test Report

Download: PDF
FCCID_4180749

                                                                                                                  Test Report
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS



                  Report No                ES2787-1

                         Client            WaveMark, Incorporated


                      Address              300 Baker Avenue
                                           Suite 160 Concord, MA 01742

                        Phone              978-431-1633

               Items tested                Labrador
                   FCC ID                  UQYHF3000
                         IC                8182A-HF3000
                       FRN                 0013630066

        Equipment Type                     Part 15 Low Power Communication Device Transmitter
        Equipment Code                     DXX

     FCC/IC Rule Parts                     CFR Title 47 FCC Part 15.225, ISED Canada RSS-210 Issue 9 Annex
                                           B.6

                 Test Dates                October 8th to 11th, 2018

                       Results             As detailed within this report



               Prepared by
                                               Chris Hamel – EMC Engineer



             Authorized by

                                               Yunus Faziloglu – Sr. Engineer


                  Issue Date                   2/11/2019


    Conditions of Issue                    This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’
                                           section on page 22 of this report.


Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under
Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation.
                           ____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                                                         page 1 of 23


                    Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
               ______________________________________________________________________


Contents

 Contents .................................................................................................................................. 2
 Summary and Test Methodology ............................................................................................. 3
 Product Tested - Configuration Documentation ....................................................................... 4
 Statement of Conformity .......................................................................................................... 5
 Modifications Required for Compliance ................................................................................... 5
 Test Results ............................................................................................................................ 6
   Transmitter Fundamental ..................................................................................................... 6
   Frequency Mask .................................................................................................................. 7
   99% Occupied Bandwidth .................................................................................................... 9
   Radiated Spurious Emissions ............................................................................................ 10
   AC Line Conducted Emissions ........................................................................................... 14
 Measurement Uncertainty...................................................................................................... 21
 Conditions Of Testing ............................................................................................................ 22


                                                                                                                  Form Final Report REV 12-07-15




                       ____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                                                    page 2 of 23


                    Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
               ______________________________________________________________________



Summary and Test Methodology

This test report supports an application for certification of a transmitter operating pursuant to:
CFR Title 47 FCC Part 15.225, ISED Canada RSS-210 Issue 9 Annex B.6

The product is Labrador. It is an RFID cabinet that operates at 13.56MHz with loop antennas.
Only one of the loop antennas in the cabinet can transmit at a time.


All testing was performed in accordance with ANSI C63.10 2013. Radiated emissions were
maximized by rotating the device and varying the test antenna’s height and polarity. EUT
antennas are internal and therefore cannot be maximized separately. The loop antenna under
test is labelled in the corresponding data tables.


Frequency stability test under extreme conditions was not performed due to the size of the EUT.
Compliance claim for that requirement is based on the existing certification of the RFID module
with FCC ID: PJMLRM1002 and IC: 6633A-LRM1002.


EUT operating voltage is 100-240VAC.
For AC line conducted emissions 50Ω/50µH LISN was used.
Environmental conditions are shown in the associated data tables.
Following bandwidths were used during radiated spurious and line conducted emissions tests.

             Frequency                                      RBW                                        VBW
             9-150KHz                                      200Hz                                       1kHz
            0.15-30MHz                                      9kHz                                       30kHz
            30-1000MHz                                     120kHz                                      1MHz

We found that the product met the above requirements without modification. The test sample
was received in good condition.




Release Control Record
   Issue No.     Reason for change                  Date Issued
       1        Original Release                    February 11, 2019
               _____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                               page 3 of 23


                       Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                  ______________________________________________________________________


Product Tested - Configuration Documentation

                                                                             EUT Configuration
            Work Order:         S2787
              Company:          WaveMark, Incorporated
        Company Address:        300 Baker Avenue Suite 160
                                Concord, MA, 01742

                   Contact:     Robert Quinn

                                                     MN                                              PN                                      SN
                  EUT:                             Labrador                                                                                Sample 1
        EUT Description:        RFID cabinet
     EUT Max Frequency:         13.56 MHz
     EUT Min Frequency:         13.56 MHz

Support Equipment                                               MN                                                                   SN
Laptop computer
Apple iPad

     Port Label          Port Type       # ports      # populated      cable type       shielded        ferrites   length (m)   in/out    under       comment
                                                                                                                                           test
AC Mains                Power AC        1             1              Power AC          No             No           2            in        yes
Ethernet                Ethernet        1             1              Ethernet          No             No           10           in        yes

Software Operating Mode Description:
RFID antennas are active and transmitting.



                                                                             Clock Frequencies
            frequencies (MHz)      13.56 **This clock list corresponds to the transmitter portion of the device




                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                       page 4 of 23


                Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
           ______________________________________________________________________


Statement of Conformity
RSS-GEN       RSP-100         RSS 210          Part 15          Comments
6.4                                            15.15(b)         There are no controls accessible to the user that
                                                                varies the output power to operate in violation of the
                                                                regulatory requirements.
              3.1                                 15.19         The label is shown in the label exhibit.
              3.2                                 15.21         Information to the user is shown in the instruction
                                                                manual exhibit.
                                                  15.27         No special accessories are required for compliance.
3.2                                               15.31         The EUT was tested in accordance with the
                                                                measurement standards in this section.
6.13.2                                            15.33         Frequency range was investigated according to this
                                                                section, unless noted in specific rule section under
                                                                which the equipment operates.
6.13.1                                            15.35         The EUT emissions were measured using the
                                                                measurement detector and bandwidth specified in
                                                                this section, unless noted in specific rule section
                                                                under which the equipment operates.
6.8                                              15.203         EUT has an integral loop antenna
8.10                                             15.205         The fundamental is not in a Restricted band and the
                                                 15.209         spurious and harmonic emissions in the Restricted
                                                                bands comply with the general emission limits of
                                                                15.209 or RSS-Gen as applicable
8.8                                              15.207         EUT meets the AC Line conducted emissions
                                                                requirements of this section.
                                                 15.225         The unit complies with the requirements of 15.225.
                                                                For frequency stability under extreme conditions
                                                                compliance claim is based on the existing
                                                                certification of the RFID module with
                                                                FCC ID: PJMLRM1002
                              Annex B.6                         The unit complies with the requirements of RSS-210
                                                                Annex B.6. For frequency stability under extreme
                                                                conditions compliance claim is based on the existing
                                                                certification of the RFID module with
                                                                IC: 6633A-LRM1002
6.7                                                             Occupied Bandwidth measurements were made.


Modifications Required for Compliance

None




                 _____________________________________________________________
         Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
         One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 5 of 23


                           Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                      ______________________________________________________________________


Test Results
Transmitter Fundamental
LIMIT
15.225(a) Field strength of any emissions within the band 13.553-13.567 MHz shall not exceed
15,848 microvolts/meter at 30 meters.

MEASUREMENTS / RESULTS
**Tested Loops 1-12 on top, mid, and bottom shelves. Worst case fundamental was top shelf
loop 1.

Radiated Emissions Table                                                                            CSsoft Radiated Emissions Calculator            v 1.017.208
            Date: 11-Oct-18                 Company: Cardinal                                                                            Work Order: S2787
      Engineer: AKZ                         EUT Desc: Labrador                                                 EUT Operating Voltage/Frequency: 230Vac/50Hz
          Temp: 22.2                        Humidity: 48%                     Pressure: 1015mBar
                        Frequency Range: 13.56MHz                                                              Measurement Distance: 3 m
           Notes: Worst Orientation: 0 degree

                                                                                                        ---                                  FCC 15.225
    Antenna                                     Pream p   Antenna   Cable    Adjusted
  Polarization      Frequency     Reading       Factor    Factor    Factor   Reading      Lim it      Margin      Result       Lim it       Margin              Result
    (0° - 90°)        (MHz)        (dBµV)        (dB)      (dB/m)    (dB)    (dBµV/m)    (dBµV/m)      (dB)     (Pass/Fail)   (dBµV/m)       (dB)             (Pass/Fail)


Top Shelf Loop 1
   0 degree           13.56         63.1         0.0       38.9      0.3      102.3        ---          ---         ---        124.0         -21.7              Pass
      Test Site: EMI Chamber 2              Cable 1: Asset #2051                                      Cable 2: Asset #2054                  Cable 3: Asset #2465
      Analyzer: 2093 SA                    Preamp: None                                              Antenna: Sm Loop (high)             Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.208                                                                                              Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor




                                _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                    page 6 of 23


                                               Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                                          ______________________________________________________________________


Frequency Mask
LIMIT
(a) The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed
15,848 microvolts/meter at 30 meters.
(b) Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any
emissions shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any
emissions shall not exceed 106 microvolts/meter at 30 meters.
(d) The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall
not exceed the general radiated emission limits in §15.209.

MEASUREMENTS / RESULTS
PLOTS
                                                                                                                          FCC 15.225 Frequency Mask
                                                                                  FCC 15.225                              Parallel Emissions
                                140.0


                                120.0
  Adjusted Amplitude (dBuV/m)




                                100.0


                                 80.0


                                 60.0


                                 40.0


                                 20.0


                                  0.0
                                   13.0000              13.2000            13.4000             13.6000            13.8000              14.0000
                                                                                     Frequency (MHz)

                                                                          Parallel (0 degree) Mask




                                                _____________________________________________________________
                                        Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                                        One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828             page 7 of 23


                                                  Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                                             ______________________________________________________________________


                                                                                                                                   FCC 15.225 Frequency Mask
                                  140.0                                               FCC 15.225                                   Perpendicular Emissions



                                  120.0



                                  100.0
    Adjusted Amplitude (dBuV/m)




                                   80.0



                                   60.0



                                   40.0



                                   20.0



                                    0.0
                                     13.0000                 13.2000          13.4000               13.6000                    13.8000             14.0000
                                                                                         Frequency (MHz)



                                                                       Perpendicular (90 degree) Mask

Rev. 10/9/2018
            Spectrum Analyzers / Receivers /Preselectors                     Range         MN            Mfr              SN      Asset Cat Calibration Due Calibrated on
                                          2093 MXE EMI Receiver           20Hz-26.5GHz   N9038A         Agilent        MY51210181 2093    I    11/16/2018     11/16/2017
_
                                      Radiated Emissions Sites              FCC Code     IC Code     VCCI Code           Range    Asset Cat Calibration Due Calibrated on
                                             EMI Chamber 2                   719150      2762A-7        A-0015         30-1000MHz 1686    I    12/21/2018     12/21/2016
                                             EMI Chamber 2                   719150      2762A-7        A-0015          1-18GHz   1686    I    12/21/2018     12/21/2016
_
                                                Antennas                     Range         MN            Mfr              SN      Asset Cat Calibration Due Calibrated on
                                               Small Loop                 10kHz-30MHz PLA-130/A          ARA              1024     755    I     7/23/2020      7/23/2018
_
                                   Meteorological Meters/Chambers                          MN            Mfr              SN      Asset Cat Calibration Due Calibrated on
                                     Weather Clock (Pressure Only)                       BA928     Oregon Scientific    C3166-1    831    I     5/15/2020      5/15/2018
                                               TH A#2081                                 HTC-1           HDE                      2081    II    3/22/2019      3/22/2018
_
                                                 Cables                      Range                       Mfr                             Cat Calibration Due Calibrated on
                                              Asset #2051                 9kHz - 18GHz                Florida RF                          II    3/7/2019       3/7/2018
                                              Asset #2054                 9kHz - 18GHz                Florida RF                          II   10/31/2018     10/31/2017
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                                    _____________________________________________________________
                                          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                                          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                            page 8 of 23


                 Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
            ______________________________________________________________________


99% Occupied Bandwidth
REQUIREMENT
When an occupied bandwidth is not specified in the applicable RSS, the transmitted signal
bandwidth to be reported is its 99% emission bandwidth, as calculated or measured.
[RSS-Gen Issue 5 Section 6.7]




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 9 of 23


                             Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                        ______________________________________________________________________


Radiated Spurious Emissions

LIMITS
The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not
exceed the general radiated emission limits in §15.209.
[15.225(d)]

MEASUREMENTS / RESULTS
REMI 9kHz to 1MHz: No emissions above the measurement system noise floor were detected
and noise floor was more than 20dB below the 15.209 limits.
Radiated Emissions Table                                                                                           CSsoft Radiated Emissions Calculator                       v 1.017.208
          Date: 11-Oct-18                      Company: Cardinal                                                                                                  Work Order: S2787
    Engineer: AKZ                              EUT Desc: Labrador                                                                 EUT Operating Voltage/Frequency: 230Vac/50Hz
        Temp: 22.2C                            Humidity: 48%                            Pressure: 1015mbar
                        Frequency Range: 1-30MHz                                                                                 Measurement Distance: 3 m
        Notes: Top Shelf Loop 1
                                                                                                                      15.209                                                   ---
   Antenna                                       Pream p     Antenna      Cable       Adjusted
 Polarization      Frequency       Reading        Factor       Factor     Factor       Reading           Lim it       Margin           Result          Lim it        Margin                   Result
   (0° - 90°)         (MHz)         (dBµV)         (dB)        (dB/m)      (dB)        (dBµV/m)        (dBµV/m)         (dB)       (Pass/Fail)        (dBµV/m)         (dB)                 (Pass/Fail)
      0            27.12          16.0         0.0        37.3       0.5        53.8                     69.5          -15.7           Pass             ---             ---                     ---
No other emissions in the 1-30MHz range, except the fundamental (see band mask)                           ---            ---            ---             ---             ---                     ---
    Test Site: EMI Chamber 2             Cable 1: Asset #2051                                                          Cable 2: Asset #2054                          Cable 3: Asset #2465
    Analyzer: ---                        Preamp: None                                                                 Antenna: Sm Loop (high)                     Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.208                                                                                                                            Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor


                                                                                   1-30MHz REMI
Rev. 10/9/2018
         Spectrum Analyzers / Receivers /Preselectors                       Range            MN                Mfr             SN             Asset    Cat       Calibration Due          Calibrated on
                       2093 MXE EMI Receiver                            20Hz-26.5GHz       N9038A            Agilent        MY51210181        2093      I          11/16/2018              11/16/2017
_
                     Radiated Emissions Sites                             FCC Code        IC Code          VCCI Code           Range          Asset    Cat       Calibration Due          Calibrated on
                           EMI Chamber 2                                    719150         2762A-7           A-0015         30-1000MHz        1686      I          12/21/2018              12/21/2016
                           EMI Chamber 2                                    719150         2762A-7           A-0015           1-18GHz         1686      I          12/21/2018              12/21/2016
_
                              Antennas                                      Range            MN                Mfr               SN           Asset    Cat       Calibration Due          Calibrated on
                             Small Loop                                 10kHz-30MHz PLA-130/A                 ARA               1024           755      I           7/23/2020               7/23/2018
_
                Meteorological Meters/Chambers                                               MN                Mfr               SN           Asset    Cat       Calibration Due          Calibrated on
                   Weather Clock (Pressure Only)                                            BA928       Oregon Scientific      C3166-1         831       I          5/15/2020               5/15/2018
                              TH A#2081                                                     HTC-1             HDE                             2081      II          3/22/2019               3/22/2018
_
                               Cables                                       Range                              Mfr                                     Cat       Calibration Due          Calibrated on
                             Asset #2051                                9kHz - 18GHz                       Florida RF                                   II           3/7/2019               3/7/2018
                             Asset #2054                                9kHz - 18GHz                       Florida RF                                   II         10/31/2018              10/31/2017
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                 _____________________________________________________________
                     Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                     One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                                page 10 of 23


                         Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                    ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                           Work Order - S2787
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - 230V / 50Hz
30-1000MHz Vertical Data                                           Test Site - CH-2
Operator: ZJ                                                       Conditions - 23.7°C; 40%RH; 1025mBar
Notes:
Top Shelf - Loop 1                                                 EUT Maximum Frequency - 900MHz



Data Taken at 03:03:47 PM, Tuesday, October 09, 2018
                                                Lim1:                            Worst       Lim2:                             Worst
            Raw QP    Correction Adjusted QP FCC_pt15_2 Margin to Test Results   Margin   FCC_pt15_1 Margin to Test Results    Margin   Antenna     EUT
Frequency   Reading     Factor    Amplitude       09     Lim1        Lim1         Lim1    09_Class_B  Lim2        Lim2          Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)      (dB)     (Pass/Fail)    (dB)     (cm)     (degrees)
 31.813      36.5       -3.1         33.5       40         -6.5       PASS                   40         -6.5       PASS                  100        100
 127.438     48.9       -8.4         40.5       43.5        -3        PASS         -3       43.5         -3        PASS          -3      219        160
 163.104     29.9       -10.3        19.6       43.5      -23.9       PASS                  43.5       -23.9       PASS                  112        171
 165.883     28.3       -10.5        17.8       43.5      -25.7       PASS                  43.5       -25.7       PASS                  127        155
 499.967     42.1       -3.5         38.7       46         -7.3       PASS                   46         -7.4       PASS                  108        205


Curtis Straus - a Bureau Veritas Company                           Work Order - S2787
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - 230V / 50Hz
30-1000MHz Horizontal Data                                         Test Site - CH-2
Operator: ZJ                                                       Conditions - 23.7°C; 40%RH; 1025mBar
Notes:
Top Shelf - Loop 1                                                 EUT Maximum Frequency - 900MHz



Data Taken at 02:45:02 PM, Tuesday, October 09, 2018
                                                Lim1:                            Worst       Lim2:                             Worst
            Raw QP    Correction Adjusted QP FCC_pt15_2 Margin to Test Results   Margin   FCC_pt15_1 Margin to Test Results    Margin   Antenna     EUT
Frequency   Reading     Factor    Amplitude       09     Lim1        Lim1         Lim1    09_Class_B  Lim2        Lim2          Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dbµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)      (dB)     (Pass/Fail)    (dB)     (cm)     (degrees)
 127.473     47.4       -8.4         38.9       43.5       -4.6       PASS        -4.6      43.5        -4.6       PASS         -4.6     275         54
 139.261      40        -8.9         31.1       43.5      -12.4       PASS                  43.5       -12.4       PASS                  225        274
 141.225     43.1       -9.1          34        43.5       -9.5       PASS                  43.5        -9.5       PASS                  175        268
 500.014     43.3       -3.5         39.8       46         -6.2       PASS                   46         -6.2       PASS                  195        155
 875.004     38.6        2.1         40.7       46         -5.3       PASS                   46         -5.3       PASS                  141        130
                                            30-1000MHz Top Shelf - Worst Case Loop 1

Curtis Straus - a Bureau Veritas Company                           Work Order - S2787
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - 230V / 50Hz
Top Peaks Vertical 30-1000MHz                                      Test Site - CH-2
Operator: ZJ                                                       Conditions - 23.7°C; 40%RH; 1025mBar
Notes:
Mid Shelf - Loop 6                                                 EUT Maximum Frequency - 900MHz



Data Taken at 03:42:18 PM, Tuesday, October 09, 2018
                                    Adjusted    Lim1:                            Worst       Lim2:                             Worst
             Peak     Correction     Peak    FCC_pt15_2    Lim1     Lim1 Test    Margin   FCC_pt15_1    Lim2     Lim2 Test     Margin   Antenna   Turntable
Frequency   Reading     Factor     Amplitude      09      Margin     Results      Lim1    09_Class_B   Margin     Results       Lim2     Height    Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)      (dB)     (Pass/Fail)    (dB)     (cm)     (degrees)
 31.867      38.1       -3.2          35        40          -5        PASS                   40          -5        PASS                  100        270
 127.485     50.2       -8.5         41.7       43.5       -1.8       PASS        -1.8      43.5        -1.8        -1.8                 200        135
 500.014     43.6       -3.5         40.2       46         -5.8       PASS                   46         -5.9       PASS                  100        180
 749.982     36.7        0.3          37        46          -9        PASS                   46          -9        PASS                  100        135
 874.991     36.3        2.1         38.5       46         -7.5       PASS                   46         -7.6       PASS                  200        180




                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                       page 11 of 23


                         Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                    ______________________________________________________________________

Curtis Straus - a Bureau Veritas Company                           Work Order - S2787
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - 230V / 50Hz
Top Peaks Horizontal 30-1000MHz                                    Test Site - CH-2
Operator: ZJ                                                       Conditions - 23.7°C; 40%RH; 1025mBar
Notes:
Mid Shelf - Loop 6                                                 EUT Maximum Frequency - 900MHz



Data Taken at 03:42:18 PM, Tuesday, October 09, 2018
                                    Adjusted    Lim1:                            Worst       Lim2:                            Worst
             Peak     Correction     Peak    FCC_pt15_2    Lim1    Lim1 Test     Margin   FCC_pt15_1    Lim2    Lim2 Test     Margin   Antenna     EUT
Frequency   Reading     Factor     Amplitude      09      Margin    Results       Lim1    09_Class_B   Margin    Results       Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)      (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 127.243     47.6       -8.3         39.3       43.5       -4.2      PASS         -4.2      43.5        -4.2      PASS         -4.2     250         45
 139.634      48        -9.2         38.7       43.5       -4.8      PASS                   43.5        -4.8      PASS                  200         90
 145.333     45.3       -9.6         35.7       43.5       -7.8      PASS                   43.5        -7.8      PASS                  250         90
 500.014     43.4       -3.5          40        46          -6       PASS                    46         -6.1      PASS                  200        180
 875.015     38.3        2.1         40.4       46         -5.6      PASS                    46         -5.6      PASS                  150        225

                                            30-1000MHz Mid Shelf - Worst Case Loop 6

Curtis Straus - a Bureau Veritas Company                           Work Order - S2787
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - 230V / 50Hz
Top Peaks Vertical 30-1000MHz                                      Test Site - CH-2
Operator: ZJ                                                       Conditions - 23.7°C; 40%RH; 1025mBar
Notes:
Bottom Shelf - Loop 2                                              EUT Maximum Frequency - 900MHz



Data Taken at 03:22:38 PM, Tuesday, October 09, 2018
                                    Adjusted    Lim1:                            Worst       Lim2:                            Worst
             Peak     Correction     Peak    FCC_pt15_2    Lim1    Lim1 Test     Margin   FCC_pt15_1    Lim2    Lim2 Test     Margin   Antenna   Turntable
Frequency   Reading     Factor     Amplitude      09      Margin    Results       Lim1    09_Class_B   Margin    Results       Lim2     Height    Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)      (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 31.843       37        -3.1         33.8       40         -6.2      PASS                    40         -6.2      PASS                  100         90
 127.485     49.5       -8.5         41.1       43.5       -2.4      PASS         -2.4      43.5        -2.5      PASS         -2.4     200        135
 499.989     43.7       -3.5         40.2       46         -5.8      PASS                    46         -5.8      PASS                  100        180
 750.007     37.2        0.3         37.5       46         -8.5      PASS                    46         -8.5      PASS                  100        135
 874.991     36.8        2.1         38.9       46         -7.1      PASS                    46         -7.1      PASS                  200        180


Curtis Straus - a Bureau Veritas Company                           Work Order - S2787
Radiated Emissions Electric Field 3m Distance                      EUT Power Input - 230V / 50Hz
Top Peaks Horizontal 30-1000MHz                                    Test Site - CH-2
Operator: ZJ                                                       Conditions - 23.7°C; 40%RH; 1025mBar
Notes:
Bottom Shelf - Loop 2                                              EUT Maximum Frequency - 900MHz



Data Taken at 03:22:39 PM, Tuesday, October 09, 2018
                                    Adjusted    Lim1:                            Worst       Lim2:                            Worst
             Peak     Correction     Peak    FCC_pt15_2    Lim1    Lim1 Test     Margin   FCC_pt15_1    Lim2    Lim2 Test     Margin   Antenna     EUT
Frequency   Reading     Factor     Amplitude      09      Margin    Results       Lim1    09_Class_B   Margin    Results       Lim2     Height   Azimuth
  (MHz)     (dBµV)     (dB/m)      (dBµV/m)   (dBµV/m)     (dB)    (Pass/Fail)    (dB)    (dBµV/m)      (dB)    (Pass/Fail)    (dB)     (cm)     (degrees)
 127.485     48.3       -8.5         39.8       43.5       -3.7      PASS         -3.7      43.5        -3.7      PASS         -3.7     200         45
 141.21      43.6       -9.1         34.5       43.5        -9       PASS                   43.5         -9       PASS                  250        270
 499.989     42.9       -3.5         39.5       46         -6.5      PASS                    46         -6.6      PASS                  200        180
 875.015     38.9        2.1          41        46          -5       PASS                    46          -5       PASS                  150        135
 881.393     35.4        2.3         37.7       46         -8.3      PASS                    46         -8.3      PASS                  150        225

                                       30-1000MHz Bottom Shelf - Worst Case Loop 2



                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                      page 12 of 23


                            Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                       ______________________________________________________________________

Rev. 10/8/2018
     Spectrum Analyzers / Receivers /Preselectors                  Range            MN              Mfr                SN       Asset   Cat   Calibration Due   Calibrated on
                    2093 MXE EMI Receiver                      20Hz-26.5GHz      N9038A           Agilent        MY51210181     2093     I      11/16/2018       11/16/2017
_
                  Radiated Emissions Sites                       FCC Code        IC Code        VCCI Code             Range     Asset   Cat   Calibration Due   Calibrated on
                        EMI Chamber 2                              719150        2762A-7          A-0015         30-1000MHz     1686     I      12/21/2018       12/21/2016
_
         Preamps /Couplers Attenuators / Filters                   Range            MN              Mfr                SN       Asset   Cat   Calibration Due   Calibrated on
                           2444 PA                               9KHz-6GHz       BBV9744      SCWARZBECK                67      2444     I       2/5/2019         2/5/2018
_
                          Antennas                                 Range            MN              Mfr                SN       Asset   Cat   Calibration Due   Calibrated on
                       Red-Brown Bilog                          30-2000MHz         JB1             Sunol             A0032406   1218     I       1/13/2019        1/13/2017
_
            Meteorological Meters/Chambers                                          MN              Mfr                SN       Asset   Cat   Calibration Due   Calibrated on
                 Weather Clock (Pressure Only)                                    BA928      Oregon Scientific       C3166-1    831      I       5/15/2020        5/15/2018
                          TH A#2080                                               HTC-1            HDE                          2080     II      3/22/2019        3/22/2018
_
                            Cables                                 Range                            Mfr                                 Cat   Calibration Due   Calibrated on
                         Asset #2051                            9kHz - 18GHz                    Florida RF                               II      3/7/2019         3/7/2018
                         Asset #2054                            9kHz - 18GHz                    Florida RF                               II     10/31/2018       10/31/2017
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                               _____________________________________________________________
                     Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                     One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                    page 13 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


AC Line Conducted Emissions

LIMITS

             Frequency of     Quasi-peak limit    Average limit
            emission (MHz)        (dBµV)             (dBµV)
                   0.15-0.5      66 to 56*          56 to 46*
                      0.5-5          56                46
                       5-30          60                50
         *Decreases with the logarithm of the frequency.
[47 CFR 15.207(a)]

MEASUREMENTS / RESULTS
*3 sets of data are presented; the worst case loop from the bottom shelf, the worst case
loop from the top shelf, and no loop with RF terminated. 13.56MHz was removed from
the top and bottom loop data tables, and compliance is shown at this frequency in the RF
terminated tables.


Conducted Emissions Data Table(s):
Curtis Straus - a Bureau Veritas Company                                          Work Order # - S2787
Conducted Emissions per CISPR 16-2-1                                              EUT Power Input - 230VAC/ 50Hz
Peak Detector Data                                                                Test Site - CEMI-5
Notes:                                                                            Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Hot Lead                                            Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1



Data Taken at 11:20:16 AM, Wednesday, October 10, 2018

                                                                     QP Lim:
                                   Correction      Adjusted Pk   Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude     R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)           (dB)          (Pass/Fail)        (dB)
    0.154            44.9              20             64.9             65.8            -0.9            PASS             -0.9
    0.201            36.3              20             56.3             63.6            -7.2            PASS
    0.238            33.9             19.9            53.7             62.2            -8.4            PASS
    0.264            32.3             19.9            52.2             61.3            -9.1            PASS
    0.327            29.4             19.9            49.3             59.5            -10.2           PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                page 14 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 230VAC/ 50Hz
Final Average Detector Data                                                        Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Hot Lead                                             Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1



Data Taken at 11:20:16 AM, Wednesday, October 10, 2018

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.15             15.8              20             35.9              56             -20.1            PASS
    0.153            15.8              20             35.8             55.9             -20             PASS
    0.174            15.8              20             35.9             54.8            -18.9            PASS
    1.196            13.9             19.8            33.7              46             -12.3            PASS
    1.344            11.4             19.8            31.3              46             -14.7            PASS

                                                   Hot Lead - Top Shelf


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 230VAC/ 50Hz
Peak Detector Data                                                                 Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Neutral Lead                                         Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1



Data Taken at 11:38:23 AM, Wednesday, October 10, 2018

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    1.354             26              19.8            45.8              56             -10.2            PASS            -10.2
    1.516            25.8             19.9            45.6              56             -10.4            PASS
    1.672            25.4             19.9            45.3              56             -10.7            PASS
    1.832             26              19.9            45.8              56             -10.2            PASS
    2.448            25.9             19.9            45.8              56             -10.2            PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 15 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 230VAC/ 50Hz
Final Average Detector Data                                                        Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Neutral Lead                                         Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1



Data Taken at 11:38:23 AM, Wednesday, October 10, 2018

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    1.037            14.7             19.8            34.5              46             -11.5            PASS
    1.197             15              19.8            34.8              46             -11.2            PASS
    1.356            15.1             19.8            34.9              46             -11.1            PASS            -11.1
    1.515            14.8             19.9            34.6              46             -11.4            PASS
    1.517            14.8             19.9            34.6              46             -11.4            PASS

                                                Neutral Lead - Top Shelf


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 230VAC/ 50Hz
Peak Detector Data                                                                 Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Hot Lead                                             Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 2 Shelf



Data Taken at 01:20:29 PM, Wednesday, October 10, 2018

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.166            42.4              20             62.4             65.1             -2.7            PASS             -2.7
    0.209            40.2             19.9            60.2             63.2             -3.1            PASS
    0.243            33.1             19.9             53               62               -9             PASS
    1.36             27.6             19.8            47.5              56              -8.5            PASS
    2.453             28              19.9            47.8              56              -8.2            PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 16 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 230VAC/ 50Hz
Final Average Detector Data                                                        Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Hot Lead                                             Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 2 Shelf



Data Taken at 01:20:29 PM, Wednesday, October 10, 2018

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.156            15.9              20             35.9             55.7            -19.8            PASS
    1.03             15.2             19.8            35.1              46             -10.9            PASS
    1.188            14.8             19.8            34.6              46             -11.4            PASS
    1.346            14.2             19.8             34               46              -12             PASS
    1.519             16              19.9            35.9              46             -10.1            PASS            -10.1

                                                Hot Lead – Bottom Shelf


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 230VAC/ 50Hz
Peak Detector Data                                                                 Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Neutral Lead                                         Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 2 Shelf



Data Taken at 01:43:43 PM, Wednesday, October 10, 2018

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    1.347            27.1             19.8            46.9              56              -9.1            PASS
    1.506            27.5             19.9            47.4              56              -8.6            PASS
    1.678            27.2             19.9            47.1              56              -8.9            PASS
    1.998             27              19.9            46.9              56              -9.1            PASS
    2.157            27.7             19.9            47.6              56              -8.4            PASS             -8.4




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 17 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 230VAC/ 50Hz
Final Average Detector Data                                                        Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Neutral Lead                                         Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 2 Shelf



Data Taken at 01:43:43 PM, Wednesday, October 10, 2018

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    1.03             15.4             19.8            35.2              46             -10.8            PASS
    1.197            16.5             19.8            36.3              46              -9.7            PASS             -9.7
    1.358            16.2             19.8            36.1              46              -9.9            PASS
    1.507            12.8             19.9            32.6              46             -13.4            PASS
    1.679            15.1             19.9             35               46              -11             PASS

                                                Neutral Lead – Bottom Shelf


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 230VAC/ 50Hz
Peak Detector Data                                                                 Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Hot Lead                                             Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1 RFI into Termination



Data Taken at 12:01:29 PM, Wednesday, October 10, 2018

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    0.15             41.8              20             61.9              66              -4.1            PASS
    0.161            44.2              20             64.2             65.4             -1.2            PASS             -1.2
    0.201            34.9              20             54.9             63.6             -8.7            PASS
    0.229             35              19.9            54.9             62.5             -7.6            PASS
    0.263            33.3             19.9            53.1             61.3             -8.2            PASS
    0.424            28.3             19.8            48.1             57.4             -9.3            PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 18 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 230VAC/ 50Hz
Final Average Detector Data                                                        Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Hot Lead                                             Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1 RFI into Termination



Data Taken at 12:01:28 PM, Wednesday, October 10, 2018

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                      Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin      Avg Results       Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    1.04             14.1             19.8            33.9              46             -12.1            PASS
    1.193             15              19.8            34.8              46             -11.2            PASS
    1.348             13              19.8            32.8              46             -13.2            PASS
    1.503            12.6             19.9            32.4              46             -13.6            PASS
    1.676            14.4             19.9            34.3              46             -11.7            PASS
   13.561            28.8              20             48.7              50              -1.3            PASS             -1.3

                                                Hot Lead – RF Terminated


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1                                               EUT Power Input - 230VAC/ 50Hz
Peak Detector Data                                                                 Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Neutral Lead                                         Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1 RFI into Termination



Data Taken at 11:53:33 AM, Wednesday, October 10, 2018

                                                                      QP Lim:
                                   Correction      Adjusted Pk    Mains_FCC&CISP    Margin to the   Pk to QP Limit   Worst Margin
  Frequency     Raw Pk Reading       Factor         Amplitude      R_QP_Class_B       QP Limit          Results       (QP Limit)
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)         (dB)
    1.185            25.9             19.8            45.7              56             -10.3            PASS
    1.352            26.1             19.8            45.9              56             -10.1            PASS
    1.515            26.5             19.9            46.4              56              -9.6            PASS
    1.677            26.4             19.9            46.3              56              -9.7            PASS
    1.837            26.5             19.9            46.4              56              -9.6            PASS             -9.6
    13.56            30.2              20             50.2              60              -9.8            PASS




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                 page 19 of 23


                     Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                ______________________________________________________________________


Curtis Straus - a Bureau Veritas Company                                           Work Order # - S2787
Conducted Emissions per CISPR 16-2-1, CISPR Average Detector                       EUT Power Input - 230VAC/ 50Hz
Final Average Detector Data                                                        Test Site - CEMI-5
Notes:                                                                             Conditions: - 22.3°C; 60%RH; 1012mBar
EUT Line tested: 230VAC/50Hz; Neutral Lead                                         Test Engineer - Zac Johnson
EUT Mode of Operation: Loop 1 Shelf 1 RFI into Termination



Data Taken at 11:53:33 AM, Wednesday, October 10, 2018

                                                                      Av Lim:
                    Raw Avg        Correction      Adjusted Avg   Mains_FCC&CISP                                   Worst Avg
  Frequency         Reading          Factor         Amplitude     R_Avg_Class_B      Avg Margin     Avg Results     Margin
    (MHz)            (dBµV)           (dB)           (dBµV)           (dBµV)            (dB)         (Pass/Fail)     (dB)
    1.04             14.1             19.8            33.9              46             -12.1           PASS
    1.193             15              19.8            34.8              46             -11.2           PASS
    1.348             13              19.8            32.8              46             -13.2           PASS
    1.503            12.6             19.9            32.4              46             -13.6           PASS
    1.676            14.4             19.9            34.3              46             -11.7           PASS
   13.561            28.8              20             48.7              50              -1.3           PASS          -1.3

                                             Neutral Lead – RF Terminated




                      _____________________________________________________________
              Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
              One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828              page 20 of 23


                       Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                  ______________________________________________________________________


Measurement Uncertainty

The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note
that the uncertainty values are provided for informational purposes only and are not used in determining
the PASS/FAIL results.
                            Measurement                                Expanded Uncertainty k=2   Maximum allowable uncertainty
                   Radiated Emissions (30-1000MHz)
                                NIST                                            5.6dB                          N/A
                               CISPR                                            4.6dB                     5.2dB (Ucispr)
                   Radiated Emissions (1-26.5GHz)                               4.6dB                          N/A

                 Radiated Emissions (above 26.5GHz)                             4.9dB                          N/A

                     Magnetic Radiated Emissions                                5.6dB                          N/A
                         Conducted Emissions
                                NIST                                            3.9dB                          N/A
                               CISPR                                            3.6dB                     3.6dB (Ucispr)
                 Telco Conducted Emissions (Current)                            2.9dB                          N/A

                 Telco Conducted Emissions (Voltage)                            4.4dB                          N/A

                        Electrostatic Discharge                                 11.5%                          N/A

                 Radiated RF Immunity (Uniform Field)                           1.6dB                          N/A

                       Electrical Fast Transients                               23.1%                          N/A

                                 Surge                                          23.1%                          N/A

                        Conducted RF Immunity                                    3dB                           N/A

                          Magnetic Immunity                                     12.8%                          N/A

                          Dips and Interrupts                                    2.3V                          N/A

                              Harmonics                                         3.5%                           N/A

                                Flicker                                         3.5%                           N/A
                                                                                          -8
                     Radio frequency (@ 2.4GHz)                               3.23 x 10                      1 x 10-7

                         RF power, conducted                                   0.40dB                        0.75dB
   Maximum frequency deviation:
             Within 300Hz and 6kHz of audio frequency / Within                 3.4%                           5%
              6kHz and 25kHz of audio frequency                                 0.3dB                          3dB
                        Adjacent channel power                                  1.9dB                          3dB

    Conducted spurious emission of transmitter, valid up to 12.75GHz           2.39dB                          3dB

                    Conducted emission of receivers                             1.3dB                          3dB

         Radiated emission of transmitter, valid up to 26.5GHz                  3.9dB                          6dB

          Radiated emission of transmitter, valid up to 80GHz                   3.3dB                          6dB

           Radiated emission of receiver, valid up to 26.5GHz                   3.9dB                          6dB

            Radiated emission of receiver, valid up to 80GHz                    3.3dB                          6dB

                               Humidity                                         2.37%                          5%

                             Temperature                                        0.7°C                         1.0°C

                                 Time                                           4.1%                          10%

                     RF Power Density, Conducted                                0.4dB                          3dB

                    DC and low frequency voltages                               1.3%                           3%

                         Voltage (AC, <10kHz)                                   1.3%                           2%

                             Voltage (DC)                                       0.62%                          1%

   The above reflects a 95% confidence level




                          _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                       page 21 of 23


                       Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                  ______________________________________________________________________



Conditions Of Testing
     [Bureau Veritas Consumer Products Services, Inc., a Massachusetts corporation], and/or its affiliates (collectively, the
"Company") will conduct, at the request of the Submitter (“Client”), the tests specified on the submitted Test Request Form or equivalent in
accordance with, and subject to, the following terms and conditions (collectively, “Conditions”):
1. All orders for tests are subject to acceptance by the Company, and no order will constitute a binding commitment of the Company unless
and until such order is accepted by it, as evidenced by the issuance of a written report (“Test Report”) by the Company. The Test Report is
issued solely by the Company, is intended for the exclusive use of Client and shall not be published, used for advertising purposes, copied or
replicated for distribution to any other person or entity or otherwise publicly disclosed without the prior written consent of the Company. By
submitting a request for services to the Company, Client consents to the disclosure to accreditation bodies of those records of Client relevant
to the accreditation body's assessment of the Company's competence and compliance with relevant accreditation criteria. The Company
shall not be liable for any loss or damage whatsoever resulting from the failure of the Company to provide its services within any time period
for completion estimated by the Company. If Client anticipates using the Test Report in any legal proceeding, arbitration, dispute resolution
forum or other proceeding, it shall so notify the Company prior to submitting the Test Report in such proceeding. The Company has no
obligation to provide a fact or expert witness at such proceeding unless the Company agrees in advance to do so for a separate and
additional fee.
2. The Test Report will set forth the findings of the Company solely with respect to the test samples identified therein. Unless specifically
and expressly indicated in the Test Report, the results set forth in such Test Report are not intended to be indicative or representative of the
quality or characteristics of the lot from which a test sample is taken, and Client shall not rely upon the Test Report as being so indicative or
representative of the lot or of the tested product in general. The Test Report will reflect the findings of the Company at the time of testing
only, and the Company shall have no obligation to update the Test Report after its issuance. The Test Report will set forth the results of the
tests performed by the Company based upon the written information provided to the Company. The Test Report will be based solely on the
samples and written information submitted to the Company by Client, and the Company shall not be obligated to conduct any independent
investigation or inquiry with respect thereto.
3. The Company may, in its sole discretion, destroy samples which have been furnished to the Company for testing and which have not
been destroyed in the course of testing. The Company may delegate the performance of all or a portion of the services contemplated
hereunder to an affiliate, agent or subcontractor of the Company, and Client consents to such delegation.
4. These Conditions and the Test Report represent the entire understanding of the parties hereto with respect to the subject matter hereof
and of the Test Report, and no modification, variance or extrapolation with respect thereto shall be permitted without the prior written consent
of the Company.
5. The names, service marks, trademarks and copyrights of the Company and its affiliates, including the names “BUREAU VERITAS,”
“BUREAU VERITAS CONSUMER PRODUCTS SERVICES,” “BVCPS”, “MTL”, “ACTS”, “MTL-ACTS” and CURTIS-STRAUS
(collectively, the “Marks”) are and shall remain the sole property of the Company or its affiliates and shall not be used by Client except solely
to the extent that Client obtains the prior written approval of the Company and then only in the manner prescribed by the Company. Client
shall not contest the validity of the Marks or take any action that might impair the value or goodwill associated with the Marks or the image or
reputation of the Company or its affiliates.
6. Payment in full shall be due 30 days after the date of invoice. Interest shall be due on overdue amounts from the due date until paid at an
interest rate of 1.5% per month or, if less, the maximum rate permitted by law. The Company reserves the right, at any time and from time to
time, to revoke any credit extended to Client. Client shall reimburse the Company for any costs it incurs in collecting past due amounts,
including court costs and fees and expenses of attorneys and collection agencies. The Test Report may not be used or relied upon by Client
if and for so long as Client fails to pay when due any invoice issued by the Company or any affiliate of it to Client or any affiliate or subsidiary
of Client together with interest and penalties, if any, accrued thereon.
7. The Company disclaims any and all responsibility or liability arising out of or in connection with e-mail transmissions of such information.
8. Client understands and agrees that the Company is neither an insurer nor a guarantor, that the Company does not take the place of Client
or any designer, manufacturer, agent, buyer, distributor or transportation or shipping company, and that the Company disclaims all liability in
such capacities. Client further understands that if it seeks assurance against loss or damage, it should obtain appropriate insurance.
9. Client agrees that the Company, by providing the services, does not take the place of Client nor any third party, nor does the Company
release them from any of their obligations, nor does the Company otherwise assume, abridge, abrogate or undertake to discharge any duty
of any third party to Client or any duty of Client or any third party to any other third party, and Client will not release any third party from its
obligations and duties with respect to the tested goods.
10. Client shall, on a timely basis, (a) provide adequate instructions to the Company in order to enable the Company to perform properly its
services, (b) provide, or cause Client's suppliers and contractors to provide, the Company with all documents necessary to enable the
Company to perform its services, (c) furnish the Company with all relevant information regarding Client's intended use and purposes of the
tested goods, (d) advise the Company of essential dates and deadlines relevant to the tested goods and (e) fully exercise all rights and
remedies available to Client against third parties in respect of the tested goods.
11. The Company shall undertake due care and ordinary skill in the performance of its services to Client, and the Company shall accept
responsibility only were such skill has not been exercised and, even in such event, only to the extent of the limitation of liability set forth
herein.
12. If Client desires to assert a claim arising from or relating to (i) the performance, purported performance or non-performance of any
services by the Company or (ii) the sale, resale, manufacture, distribution or use of any tested goods, it must submit that claim to the
Company in a writing that sets forth with particularity the basis for such claim within 60 days from discovery of the potential claim and not
more than six months after the date of issuance of the Test Report to Client. Client waives any and all such claims including, without
limitation, claims that the Test Report is inaccurate, incomplete or misleading or that additional or different testing is required, unless and
then only to the extent that Client submits a written claim to the Company within both such time periods.
13. CLIENT SHALL, EXCEPT TO THE EXTENT OF COMPANY’S LIABILITY TO CLIENT HEREUNDER (WHICH IN NO EVENT SHALL
EXCEED THE LIMITATION OF LIABILITY HEREIN), HOLD HARMLESS AND INDEMNIFY THE COMPANY, ITS AFFILIATES AND THEIR
RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, AGENTS AND SUBCONTRACTORS AGAINST ALL ACTUAL OR ALLEGED
THIRD PARTY CLAIMS FOR LOSS, DAMAGE OR EXPENSE OF WHATSOEVER NATURE AND HOWSOEVER ARISING FROM OR
RELATING TO (i) THE PERFORMANCE, PURPORTED PERFORMANCE OR NON-PERFORMANCE OF ANY SERVICES BY THE
COMPANY OR (ii) THE SALE, RESALE, MANUFACTURE, DISTRIBUTION OR USE OF ANY TESTED GOODS.
14. EXCEPT AS MAY OTHERWISE BE EXPRESSLY AGREED TO IN WRITING BY THE COMPANY AND NOTWITHSTANDING ANY
PROVISION TO THE CONTRARY CONTAINED HEREIN OR IN ANY TEST REPORT, NO WARRANTY OR GUARANTEE, EXPRESS OR
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE, IS MADE.

                         _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                               page 22 of 23


                       Test Report for WaveMark, Incorporated Report No. ES2787-1    February 11, 2019
                  ______________________________________________________________________

15. (A) IN NO EVENT WHATSOEVER SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL,
EXEMPLARY OR PUNITIVE DAMAGES IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE TEST REPORT OR THE
SERVICES PROVIDED BY THE COMPANY HEREUNDER, INCLUDING WITHOUT LIMITATION LOSS OF OR DAMAGE TO PROPERTY;
LOSS OF INCOME, PROFIT OR USE; OR ANY CLAIMS OR DEMANDS MADE AGAINST CLIENT OR ANY OTHER PERSON BY ANY
THIRD PARTY IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE SERVICES PROVIDED BY THE COMPANY
HEREUNDER.
  (B)NOTWITHSTANDING ANY PROVISION TO THE CONTRARY CONTAINED HEREIN, AND IN RECOGNITION OF THE RELATIVE
RISKS AND BENEFITS TO CLIENT AND THE COMPANY ASSOCIATED WITH THE TESTING SERVICES CONTEMPLATED HEREBY,
THE RISKS HAVE BEEN ALLOCATED SUCH THAT UNDER NO CIRCUMSTANCES WHATSOEVER SHALL THE LIABILITY OF THE
COMPANY TO CLIENT OR ANY THIRD PARTY IN RESPECT OF ANY CLAIM FOR LOSS, DAMAGE OR EXPENSE, OF WHATSOEVER
NATURE OR MAGNITUDE, AND HOWSOEVER ARISING, EXCEED AN AMOUNT EQUAL TO FIVE (5) TIMES THE AMOUNT OF THE
FEES PAID TO THE COMPANY FOR THE SPECIFIC SERVICES WHICH GAVE RISE TO SUCH CLAIM OR U.S.$10,000, WHICHEVER IS
THE LESSER AMOUNT.
16. The Company shall not be liable for any loss or damage resulting from any delay or failure in performance of its obligations hereunder
resulting directly or indirectly from any event of force majeure or any event outside the control of the Company. If any such event occurs, the
Company may immediately cancel or suspend its performance hereunder without incurring any liability whatsoever to Client.
 17. Company’s services, including these Conditions, shall be governed by, and construed in accordance with, the local laws of the country
where the Company performs the tests or, in the case of tests performed in the United States of America, the laws of Massachusetts without
regard to conflicts of laws principles. If any aspect(s) of these Conditions is found to be illegal or unenforceable, the validity, legality and
enforceability of all remaining aspects of these Conditions shall not in any way be affected or impaired thereby. Any proceeding related to
the subject matter hereof shall be brought, if at all, in the courts of the country where the Company performs the tests or, in the case of tests
performed in the United States of America, in the courts of Massachusetts. Client waives the right to interpose any counterclaim or setoffs of
any nature in any litigation arising hereunder.
The complete list of the Approved Subcontractors Curtis-Straus may use to delegate the performance of work can be provided upon request.
Rev.160009121(2)_#684340 v14CS




                         _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                             page 23 of 23



Document Created: 2019-02-18 15:00:06