55234RRF005

FCC ID: UKCWRM0B

Test Report

Download: PDF
FCCID_4313286

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                                                 Test report No:
                                                             ISED LISTED
                                                             REGISTRATION NUMBER              NIE: 55234RRF.005
                                                             4621A-4


          Test report
          USA FCC Part 15.225, 15.209
          CANADA RSS-210, RSS-Gen
           Identification of item tested                        Electronic Reader Series including all mechanical
                                                                variants.

           Trademark                                            Modular Wall Reader 2.0


           Model and /or type reference                         WRM0B (type reference: P0506)


           Other identification of the product                  HW version: 1.0
                                                                SW version: 0152 (Control Firmware) + 0136 (BGM111
                                                                Firmware)

                                                                FCC ID: UKCWRM0B
                                                                IC: 10088A-WRM0B
           Features                                             Contains a certified Bluetooth module (BGM111).


           Applicant                                            SALTO Systems, S.L.
                                                                Arkotz 9, Polígono Lanbarren
                                                                20180, Oiartzun, Gipuzkoa, SPAIN
           Test method requested, standard                      USA FCC Part 15.225 (10–1–17 Edition): Operation
                                                                within the band 13.110 -14.010.
                                                                USA FCC Part 15.209 (10–1–17 Edition): Radiated
                                                                emission limits, general requirements.
                                                                CANADA RSS-210 Issue 9 (August 2016).
                                                                CANADA RSS-Gen Issue 5 (April 2018).
                                                                ANSI C63.10-2013: American National Standard for
                                                                Testing Unlicensed Wireless Devices.
           Summary                                              IN COMPLIANCE
           Approved by (name / position & signature)            A. Llamas                           Firmado
                                                                RF Lab. Manager                     digitalmente por
                                                                                                    ALEJANDRO LLAMAS
                                                                                                    RODRIGUEZ
                                                                                                    Fecha: 2019.03.27
                                                                                                    11:01:31 +01'00'
           Date of issue                                        2019-03-27


           Report template No                                   FDT08_21



Report No: (NIE) 55234RRF.005                                                                                           2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    Index
    Competences and guarantees ......................................................................................................................3
    General conditions .........................................................................................................................................3
    Uncertainty.....................................................................................................................................................3
    Data provided by the client ............................................................................................................................3
    Usage of samples ..........................................................................................................................................4
    Test sample description .................................................................................................................................4
    Identification of the client ...............................................................................................................................5
    Testing period and place ...............................................................................................................................5
    Document history ...........................................................................................................................................5
    Environmental conditions ..............................................................................................................................5
    Remarks and comments ................................................................................................................................6
    Testing verdicts ..............................................................................................................................................7
    Summary .......................................................................................................................................................7
    Appendix A: Test results. ...............................................................................................................................8




 Report No: (NIE) 55234RRF.005                                                 Page 2 of 33                                                                    2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Competences and guarantees
    DEKRA Testing and Certification S.A.U. is a testing laboratory accredited by the National Accreditation Body
    (ENAC -Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
    DEKRA Testing and Certification is a FCC-recognized accredited testing laboratory with appropriate scope of
    accreditation that include testing performed in this test report.
    DEKRA Testing and Certification S.A.U. is a laboratory with a measurement site in compliance with the
    requirements of RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian
    Certification and Engineering Bureau. Reference File Number: ISED 4621A-4.
    In order to assure the traceability to other national and international laboratories, DEKRA Testing and
    Certification S.A.U. has a calibration and maintenance program for its measurement equipment.
    DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is
    the result of the measurements and the tests performed to the item under test on the date and under the
    conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA
    Testing and Certification S.A.U. at the time of performance of the test.
    DEKRA Testing and Certification S.A.U. is liable to the client for the maintenance of the confidentiality of all
    information related to the item under test and the results of the test.
    The results presented in this Test Report apply only to the particular item under test established in this
    document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of DEKRA Testing and Certification S.A.U.


General conditions
         1. This report is only referred to the item that has undergone the test.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
            or competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written
            permission of DEKRA Testing and Certification S.A.U.
         4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
            previous written permission of DEKRA Testing and Certification S.A.U. and the Accreditation Bodies.


Uncertainty
    Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification S.A.U. internal
    document PODT000.




Data provided by the client
    The sample consists of a Modular Wall Reader 2.0, with Bluetooth Smart (BGM111 module) and ISO14443A &
    ISO15693 standard based technology - Mifare.


    DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by
    the client and that may affect the validity of results.




 Report No: (NIE) 55234RRF.005                               Page 3 of 33                                   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Usage of samples
    Samples undergoing test have been selected by: The client.

    -     Sample S/01 is composed of the following elements:

     Control Nº                    Description                            Model                 Serial Nº               Reception

    55234C/023                  Electronic Reader                  WRM0B (type                       --                 2018/10/31
                                                                 reference: P0506)

    55234C/001                   AC/DC Adaptor                      6A-181WP12                       --                 2018/01/10

    55234C/002                      Control Unit                       CU42E0                        --                 2018/01/10

        Sample S/01 has undergone the following test(s): All tests indicated in Appendix A.




Test sample description
  Ports………………………………. :                                                                                     Cable
                                                       Port name and
                                                                                    Specified    Attached        Shielded       Coupled
                                                       description
                                                                                      max       during test                        to
                                                                                   length [m]                                   patient(3)




  Supplementary information to the
  ports………………………………. :
  Rated power supply .................... :                                                                Reference poles
                                                       Voltage and Frequency
                                                                                                L1        L2       L3       N         PE

                                                             DC: 12 Vdc from CU42xx.

  Rated Power ............................... :        1,92 W (max)

  Clock frequencies ....................... :          27,12 MHz

  Other parameters ........................ :          RS-485 bus

  Software version ......................... :         0152 (Control Firmware) + 0136 (BGM111 Firmware)

  Hardware version ........................ :          1.0

  Dimensions in cm (W x H x D) .... :                  8,2 x 8,2 x 2 cm

  Mounting position ........................ :               Wall/Ceiling mounted equipment

  Modules/parts ............................. :        Module/parts of test item                               Type       Manufacturer

                                                       BGM111                                             BLE Module Silicon Labs



 Report No: (NIE) 55234RRF.005                                      Page 4 of 33                                                  2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


  Accessories (not part of the test                      Description                                  Type        Manufacturer
  item) ............................................ :


  Documents as provided by the                           Description                                  File name   Issue date
  applicant ...................................... :
                                                         User manual

                                                         FW explanation document

 (3) Only   for Medical Equipment


Identification of the client
SALTO Systems, S.L.
Arkotz 9, Polígono Lanbarren
20180, Oiartzun, Gipuzkoa, SPAIN




Testing period and place
        Test Location                  DEKRA Testing and Certification S.A.U.
          Date (start)                 2018-10-31
         Date (finish)                 2018-11-27




Document history
   Report number                         Date                                           Description
   55234RRF.005                     2019-03-27           First release




Environmental conditions
     In the control chamber, the following limits were not exceeded during the test:

                                                                         Min. = 15 ºC
                 Temperature
                                                                         Max. = 35 ºC
                                                                         Min. = 20 %
                 Relative humidity
                                                                         Max. = 75 %
                 Shielding effectiveness                                 > 100 dB
                 Electric insulation                                     > 10 k
                 Reference resistance to earth                           <1




 Report No: (NIE) 55234RRF.005                                           Page 5 of 33                                   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    In the semianechoic chamber, the following limits were not exceeded during the test.

                                                             Min. = 15 ºC
               Temperature
                                                             Max. = 35 ºC
                                                             Min. = 20 %
               Relative humidity
                                                             Max. = 75 %
                                                             Min. = 860 mbar
               Air pressure
                                                             Max. = 1060 mbar
               Shielding effectiveness                       > 100 dB
               Electric insulation                           > 10 k
               Reference resistance to earth                 <1
                                                             < ±4 dB at 10 m distance between item under test
               Normal site attenuation (NSA)
                                                             and receiver antenna, (30 MHz to 1000 MHz)
                                                             More than 75% of illuminated surface is between 0
               Field homogeneity
                                                             and 6 dB (26 MHz to 1000 MHz).




    In the chamber for conducted measurements, the following limits were not exceeded during the test:
                   Temperature                                    Min. = 15 ºC
                                                                  Max. = 35 ºC
                   Relative humidity                              Min. = 20 %
                                                                  Max. = 35 %
                   Air pressure                                   Min. = 860 mbar
                                                                  Max. = 1060 mbar
                   Shielding effectiveness                        > 100 dB
                   Electric insulation                            > 10 k
                   Reference resistance to earth                  <1




Remarks and comments
    The tests have been performed by the technical personnel: Francisco José Alcaide, Jaime Barranquero Gómez,
    Ignacio Cabra, José Alberto Aranda, Miguel Ángel Torres.


    Used instrumentation:

           Conducted measurements:
                                                                             Last Calibration   Due Calibration

              1.      Chamber HERAEUS VMT 04/35                                  2018/06           2020/06
              2.      Signal Analyzer 20 Hz to 8 GHz ROHDE AND                   2018/08           2020/08
                      SCHWARZ FSQ8
              3.      Spectrum Analyzer PSA 3Hz-26.5 GHz                         2017/10           2019/10
                      AGILENT TECHNOLOGIES E4440A
              4.      DC Power Supply 40V/40A Rohde & Schwarz                    2018/02           2021/02
                      NGPE40




 Report No: (NIE) 55234RRF.005                               Page 6 of 33                                         2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




           Radiated measurements:
                                                                                    Last Calibration   Due Calibration

              1.      Semianechoic Absorber Lined Chamber ETS                            N.A.                 N.A.
                      LINDGREN FACT 3 200 STP
              2.      EMI Test Receiver 7 GHz ROHDE AND                                2017/08            2019/08
                      SCHWARZ ESR7
              3.      Active Loop Antenna HEWLETT PACKARD                              2018/06            2020/06
                      11966A
              4.      RF Pre-amplifier, 38 dB, 30 MHz-6 GHz BONN                       2018/07            2019/07
                      ELEKTRONIK BLNA 0360-01N
              5.      Biconical/Log Antenna 30 MHz - 6 GHz ETS                         2018/07            2021/07
                      LINDGREN 3142E




Testing verdicts

                                                   Not applicable:          N/A

                                                   Pass:                    P

                                                   Fail:                    F

                                                   Not measured:            N/M




Summary

                                                               FCC Part 15.225, 15.209
                                                             CANADA RSS-210, RSS-Gen
                                          Requirement – Test case                                      Verdict       Remark
  15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within
                                                                                                          P
                       the band 13.553 - 13.567 MHz

  15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within
                                                                                                          P
                       the band 13.410 - 13.553 MHz and 13.567 – 13.710 MHz

  15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within
                                                                                                          P
                       the band 13.110 - 13.410 MHz and 13.710 – 14.010 MHz

  15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside
                                                                                                          P
                       of the band 13.110 MHz -14.010 MHz

  15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier
                                                                                                          P
                       signal
  Supplementary information and remarks:
  None.




 Report No: (NIE) 55234RRF.005                                       Page 7 of 33                                        2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix A: Test results.




 Report No: (NIE) 55234RRF.005                               Page 8 of 33   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


                                                                               INDEX

    TEST CONDITIONS ...............................................................................................................................................10
    Occupied Bandwidth ...............................................................................................................................................13
    Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within the band 13.553 -
    13.567 MHz.............................................................................................................................................................17
    Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within the band 13.410 -
    13.553 MHz and 13.567 - 13.710 MHz ...................................................................................................................19
    Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within the band 13.110 -
    13.410 MHz and 13.710 -14.010 MHz ....................................................................................................................23
    Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside of the band 13.110 -
    14.010 MHz.............................................................................................................................................................26
    Section 15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier signal .........................31




 Report No: (NIE) 55234RRF.005                                                 Page 9 of 33                                                                   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


                                                             TEST CONDITIONS
POWER SUPPLY (V):

           Vn: 12 Vdc (*)
           Vmin: 10.2 Vdc
           Vmax: 13.8 Vdc


           Type of power supply: External power supplied from CU42xx

           Type of antenna:                 Integral, chip



The subscripts ‘n’, ‘min’ and ‘max’ mean normal, minimum and maximum respectively.

(*): Declared by applicant.



TEST FREQUENCY:

           Nominal Operating Frequency: 13.56 MHz




CONDUCTED MEASUREMENTS

The equipment under test was set up in a shielded room and it is directly connected to the spectrum analyzer
through a coupling device.




For frequency stability test the EUT was placed inside a climatic chamber and connected to a frequency meter
using a low loss cable and a coupling device. An external DC power supply was connected to the EUT for voltage
variation test.




 Report No: (NIE) 55234RRF.005                                   Page 10 of 33                      2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




RADIATED MEASUREMENTS
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna (Loop antenna for the
range between 9 kHz to 30 MHz and Bilog antenna for the range between 30 MHz to 200 MHz) is situated at a
distance of 3 m.


For radiated emissions in the range 9 kHz to 30 MHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 40 dB per decade is used to normalize the measured data for
determining compliance.

The equipment under test was set up on a non-conductive platform above the ground plane and the situation and
orientation was varied to find the maximum radiated emission. It was also rotated 360º and in the range between
30 MHz and 200 MHz the antenna height was varied from 1 to 4 meters to find the maximum radiated emission.

In the range between 9 kHz and 30 MHz the measurements were made in the three different orientation planes of
the loop antenna to determine the maximum received field.

In the range between 30 MHz and 200 MHz the measurements were made in both horizontal and vertical planes of
polarization.

The test was performed with the equipment transmitting first with only the 13.56 MHz radio and repeated with
Bluetooth Low Energy 2.4 GHz radio transmitting simultaneously to check the impact of the co-location of the other
radio interfaces. The results and plots below show the worst results obtained.




 Report No: (NIE) 55234RRF.005                               Page 11 of 33                              2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated measurements setup 9 kHz to 30 MHz.




Radiated measurements setup 30 MHz to 200 MHz.




 Report No: (NIE) 55234RRF.005                               Page 12 of 33   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


                                                             Occupied Bandwidth

RESULTS:


99 % Occupied Bandwidth and 20 dB Bandwidth.



           NFC mode ISO 14443A


                           Operation Mode                     99% Occupied Bandwidth (kHz)   20 dB Bandwidth (kHz)

                     NFC mode ISO 14443A                                  1065.8                    446.6
                Measurement uncertainty (kHz)                                       <±0.40




    -       99% Occupied Bandwidth:




 Report No: (NIE) 55234RRF.005                                     Page 13 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


    -     20 dB Bandwidth:




Verdict: PASS




 Report No: (NIE) 55234RRF.005                               Page 14 of 33   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


           NFC mode ISO 15693



                         Operation Mode                      99% Occupied Bandwidth (kHz)   20 dB Bandwidth (kHz)

                     NFC mode ISO 15693                                  348.0                     146.4
               Measurement uncertainty (kHz)                                        <±0.4




    -       99% Occupied Bandwidth:




 Report No: (NIE) 55234RRF.005                                    Page 15 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


    -     20 dB Bandwidth:




Verdict: PASS




 Report No: (NIE) 55234RRF.005                               Page 16 of 33   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



    Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions
                          within the band 13.553 -13.567 MHz
SPECIFICATION:

The field strength of any emissions within the band 13.553 – 13.567 MHz shall not exceed 15,848 microvolts/meter
(84 dBµV/m) at 30 meters.


RESULTS:

Measurement distance: 3 meters.


          NFC mode ISO 14443A

      The maximum field strength of fundamental emission:

                  Frequency (MHz)                      Maximum field strength (dBµV/m) Maximum field strength (dBµV/m)
                                                        measured at 3 m (quasi-peak        extrapolated to 30 m (40
                                                                  detector)                      dB/decade)
                   13.561                                           71.36                           31.36
          Measurement uncertainty (dB)                                              <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS



 Report No: (NIE) 55234RRF.005                                    Page 17 of 33                                   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


           NFC mode ISO 15693

      The maximum field strength of fundamental emission:

                 Frequency (MHz)                      Maximum field strength (dBµV/m) Maximum field strength (dBµV/m)
                                                       measured at 3 m (quasi-peak        extrapolated to 30 m (40
                                                                 detector)                      dB/decade)
                   13.561                                          71.07                           31.07
          Measurement uncertainty (dB)                                             <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 18 of 33                                  2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


    Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions
              within the band 13.410 - 13.553 MHz and 13.567 - 13.710 MHz


SPECIFICATION:

Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not exceed
334 microvolts/meter (50.47 dBµV/m) at 30 meters.


RESULTS:

Measurement distance: 3 meters.


- Band 13.410 - 13.553 MHz

          NFC mode ISO 14443A

                Frequency (MHz)                      Maximum field strength (dBµV/m)    Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak           extrapolated to 30 m (40
                                                                detector)                         dB/decade)
                13.553                                            57.35                              17.35
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters



Verdict: PASS



 Report No: (NIE) 55234RRF.005                                    Page 19 of 33                                    2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693

                Frequency (MHz)                      Maximum field strength (dBµV/m)    Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak           extrapolated to 30 m (40
                                                                detector)                         dB/decade)
                13.553                                            56.82                              16.82
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters



Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 20 of 33                                    2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- Band 13.567-13.710 MHz

          NFC mode ISO 14443A


                Frequency (MHz)                      Maximum field strength (dBµV/m)   Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak     extrapolated to 30 m (40 dB/decade)
                                                                detector)
                13.567                                            57.51                               17.51
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 21 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693

                Frequency (MHz)                      Maximum field strength (dBµV/m)   Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak     extrapolated to 30 m (40 dB/decade)
                                                                detector)
                13.567                                            57.05                               17.05
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 22 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


     Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions
               within the band 13.110 - 13.410 MHz and 13.710 - 14.010 MHz

SPECIFICATION:

Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz, the field strength of any emissions shall not exceed
106 microvolts/meter (40.51 dBµV/m) at 30 meters.

RESULTS:

Measurement distance: 3 meters.


- Band 13.110-13.410 MHz

          NFC mode ISO 14443A


                Frequency (MHz)                      Maximum field strength (dBµV/m)   Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak     extrapolated to 30 m (40 dB/decade)
                                                                detector)
                13.350                                            52.82                               12.82
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters


Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 23 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693


                Frequency (MHz)                      Maximum field strength (dBµV/m)   Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak     extrapolated to 30 m (40 dB/decade)
                                                                detector)
                13.402                                            30.49                               -9.51
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 24 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- Band 13.710-14.010 MHz

          NFC mode ISO 14443A


                Frequency (MHz)                      Maximum field strength (dBµV/m)   Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak     extrapolated to 30 m (40 dB/decade)
                                                                detector)
                13.770                                            52.49                               12.49
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 25 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693


                Frequency (MHz)                      Maximum field strength (dBµV/m)   Maximum field strength (dBµV/m)
                                                      measured at 3 m (quasi-peak     extrapolated to 30 m (40 dB/decade)
                                                                detector)
                13.718                                            29.73                              -10.27
       Measurement uncertainty (dB)                                                <±3.44




                                          The limit shown in the above plot is extrapolated to 3 meters




Verdict: PASS




 Report No: (NIE) 55234RRF.005                                    Page 26 of 33                                     2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


    Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions
                        outside of the band 13.110 - 14.010 MHz

SPECIFICATION:

Field strength of any emissions appearing outside of the band 13.110 MHz - 14.010 MHz band shall not exceed the
general radiated emission limits in 15.209/RSS-Gen:

                  Frequency Range                 Field strength (µV/m)            Field strength   Measurement
                       (MHz)                                                         (dBµV/m)       distance (m)
                      0.009-0.490                       2400/F(kHz)                      -              300
                      0.490-1.705                      24000/F(kHz)                      -              30
                      1.705 - 30.0                           30                        29.54            30
                         30 - 88                             100                        40               3
                        88 - 216                             150                       43.5              3
                       216 - 960                             200                        46               3
                      Above 960                              500                        54               3




RESULTS:
All tests were performed in a semi-anechoic chamber at a distance of 3 m.
The spectrum was inspected from 9 kHz to 200 MHz searching for spurious signals.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer. This
correction factor includes antenna factor, cable loss and pre-amplifier gain.




 Report No: (NIE) 55234RRF.005                                     Page 27 of 33                                   2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- Frequency range 9 kHz - 30 MHz:

          NFC mode ISO 14443A

      No spurious frequencies were found at less than 20 dB below the limit.




          The limits shown in the above plot are extrapolated to 3 meters. The highest peak corresponds to the carrier level.




Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz




 Report No: (NIE) 55234RRF.005                               Page 28 of 33                                               2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693

      No spurious frequencies were found at less than 20 dB below the limit.




          The limits shown in the above plot are extrapolated to 3 meters. The highest peak corresponds to the carrier level.




Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz




 Report No: (NIE) 55234RRF.005                               Page 29 of 33                                               2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- Frequency range 30 - 200 MHz

          NFC mode ISO 14443A



              Spurious frequency                   Detector      Emission Level        Polarization         Measurement
                    (MHz)                                          (dBµV/m)                                Uncertainty (dB)
                      35.6865                    Quasi peak            23.2                  V                 <± 3.88
                      40.6788                    Quasi peak            25.1                  V                 <± 3.88




                                       The above plot shows the results of the scan using peak detector.


Verdict: PASS




 Report No: (NIE) 55234RRF.005                                   Page 30 of 33                                                2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693



              Spurious frequency                   Detector      Emission Level        Polarization         Measurement
                    (MHz)                                          (dBµV/m)                                Uncertainty (dB)
                      35.4712                    Quasi peak            22.7                  V                 <± 3.88
                      40.6902                    Quasi peak            25.6                  V                 <± 3.88




                                       The above plot shows the results of the scan using peak detector.


Verdict: PASS




 Report No: (NIE) 55234RRF.005                                   Page 31 of 33                                                2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


 Section 15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier
                                       signal


SPECIFICATION:

The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating frequency over a
temperature variation of –20 degrees to +50 degrees C at normal supply voltage, and for a variation in the primary
supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For hand carried,
battery powered equipment, reduce primary supply voltage to the battery operating end point which shall be
specified by the manufacturer.



RESULTS:

Nominal Operating Frequency: 13.56 MHz.

          NFC mode ISO 14443A

           - Frequency stability over temperature variations:

                                         Temperature (ºC)           Frequency Error   Frequency Error
                                                                         (Hz)              (%)
                                                  +50                   1.310            0.000010
                                                  +40                   1.794            0.000013
                                                  +30                   4.165            0.000031
                                                  +20                   3.521            0.000026
                                                  +10                   0.735            0.000005
                                                   0                    0.933            0.000007
                                                  -10                   1.820            0.000013
                                                  -20                   1.023            0.000008




           - Frequency stability over voltage variations:

                                    DC Supply         Voltage (V)      Frequency Error   Frequency Error
                                                                            (Hz)              (%)

                                       Vmax                  13.8            6.568          0.000048
                                       Vmin                  10.2            5.468          0.000040




           Verdict: PASS




 Report No: (NIE) 55234RRF.005                                       Page 32 of 33                         2019-03-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693

           - Frequency stability over temperature variations:

                                         Temperature (ºC)           Frequency Error   Frequency Error
                                                                         (Hz)              (%)
                                                  +50                   5.132            0.000038
                                                  +40                   5.132            0.000038
                                                  +30                   4.370            0.000032
                                                  +20                   4.370            0.000032
                                                  +10                   4.370            0.000032
                                                   0                    4.470            0.000033
                                                  -10                   8.240            0.000061
                                                  -20                   5.121            0.000038




           - Frequency stability over voltage variations:

                                    DC Supply         Voltage (V)      Frequency Error   Frequency Error
                                                                            (Hz)              (%)

                                       Vmax                  13.8            4.378          0.000032
                                       Vmin                  10.2            4.378          0.000032




           Verdict: PASS




 Report No: (NIE) 55234RRF.005                                       Page 33 of 33                         2019-03-27



Document Created: 2019-03-27 11:01:31
Document Modified: 2019-03-27 11:01:31

© 2024 FCC.report