55234RRF007

FCC ID: UKCWRD0B

Test Report

Download: PDF
FCCID_4313369

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                                                 Test report No:
                                                             ISED LISTED
                                                             REGISTRATION NUMBER              NIE: 55234RRF.007
                                                             4621A-2 & 4621A-4


         Partial Test report
         USA FCC Part 15.209
         CANADA RSS-Gen Issue 5
           Identification of item tested                        Electronic Reader Series including all mechanical
                                                                variants.

           Trademark                                            XS4 Wall Reader 2.0.


           Model and /or type reference                         WRD0S (type reference: P1619).


           Other identification of the product                  HW version: 1.0.
                                                                SW version: 0130 (Control Firmware).

                                                                FCC ID: UKCWRD0B.
                                                                IC: 10088A-WRD0B.
           Features                                             Contains a certified Bluetooth module (DirectKey).


           Applicant                                            SALTO Systems, S.L.
                                                                Arkotz 9, Polígono Lanbarren
                                                                20180, Oiartzun, Gipuzkoa, SPAIN
           Test method requested, standard                      USA FCC Part 15.209 (10–1–17 Edition): Radiated
                                                                emission limits, general requirements.
                                                                CANADA RSS-Gen Issue 5 (April 2018). General
                                                                Requirements for Compliance of Radio Apparatus.
                                                                   -Transmitter out of band radiated emissions with
                                                                   simultaneous transmissions.
                                                                ANSI C63.10-2013: American National Standard for
                                                                Testing Unlicensed Wireless Devices.
           Summary                                              IN COMPLIANCE
           Approved by (name / position & signature)            A. Llamas
                                                                RF Lab. Manager                      Firmado digitalmente por
                                                                                                     ALEJANDRO LLAMAS RODRIGUEZ
                                                                                                     Fecha: 2019.05.06 12:42:58 +02'00'




           Date of issue                                        2019-05-06


           Report template No                                   FDT08_21




Report No: (NIE) 55234RRF.007                                                                                                             2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    Index
    Competences and guarantees ......................................................................................................................3
    General conditions .........................................................................................................................................3
    Uncertainty.....................................................................................................................................................3
    Data provided by the client ............................................................................................................................3
    Usage of samples ..........................................................................................................................................4
    Test sample description .................................................................................................................................4
    Identification of the client ...............................................................................................................................5
    Testing period and place ...............................................................................................................................5
    Document history ...........................................................................................................................................5
    Environmental conditions ..............................................................................................................................5
    Remarks and comments ................................................................................................................................6
    Testing verdicts ..............................................................................................................................................7
    Summary .......................................................................................................................................................7
    Appendix A: Test results. ...............................................................................................................................8




 Report No: (NIE) 55234RRF.007                                                 Page 2 of 23                                                                    2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Competences and guarantees
    DEKRA Testing and Certification is a testing laboratory accredited by the National Accreditation Body (ENAC -
    Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
    DEKRA Testing and Certification is a FCC-recognized accredited testing laboratory with appropriate scope
    of accreditation that include testing performed in this test report.
    DEKRA Testing and Certification is a laboratory with a measurement site in compliance with the requirements of
    RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian Certification and
    Engineering Bureau. Reference File Number: ISED 4621A-2 & 4621A-4.
    In order to assure the traceability to other national and international laboratories, DEKRA Testing and
    Certification has a calibration and maintenance program for its measurement equipment.
    DEKRA Testing and Certification guarantees the reliability of the data presented in this report, which is the
    result of the measurements and the tests performed to the item under test on the date and under the conditions
    stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and
    Certification at the time of performance of the test.
    DEKRA Testing and Certification is liable to the client for the maintenance of the confidentiality of all information
    related to the item under test and the results of the test.
    The results presented in this Test Report apply only to the particular item under test established in this
    document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of DEKRA Testing and Certification.




General conditions
         1. This report is only referred to the item that has undergone the test.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
            or competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written
            permission of DEKRA Testing and Certification.
         4. This test report cannot be used partially or in full for publicity and/or promotional purposes without
            previous written permission of DEKRA Testing and Certification and the Accreditation Bodies.




Uncertainty
    Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification S.A.U. internal
    document PODT000.




Data provided by the client
    The sample consists of a XS4 Wall Reader 2.0, with Bluetooth Smart (DirectKey module) and ISO14443A &
    ISO15693 standard based technology – Mifare.
    DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by
    the client and that may affect the validity of results.




 Report No: (NIE) 55234RRF.007                               Page 3 of 23                                      2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Usage of samples
    Samples undergoing test have been selected by: The client.



    -     Sample S/01 is composed of the following elements:

     Control Nº                    Description                          Model                    Serial Nº              Reception

    55234C/011                  Electronic Reader                  WRD0S (type                        --                2018/01/11
                                                                 reference: P1619)

    55234C/001                   AC/DC Adaptor                       6A-181WP12                       --                2018/01/10

    55234C/002                      Control Unit                       CU42E0                         --                2018/01/10

        Sample S/01 has undergone the following test(s): All tests indicated in Appendix A.




Test sample description
  Ports………………………………. :                                                                                     Cable
                                                       Port name and
                                                                                     Specified    Attached      Shielded        Coupled
                                                       description
                                                                                       max       during test                       to
                                                                                    length [m]                                  patient(3)




  Supplementary information to the
  ports………………………………. :
  Rated power supply .................... :                                                                Reference poles
                                                       Voltage and Frequency
                                                                                                 L1        L2      L3       N         PE

                                                             DC: 12 Vdc from CU42xx.

  Rated Power ............................... :        1.8 W (max)

  Clock frequencies ....................... :          27,12 MHz

  Other parameters ........................ :          RS-485 bus

  Software version ......................... :         0130 (Control Firmware)

  Hardware version ........................ :          1.0

  Dimensions in cm (W x H x D) .... :                  9,6 x 13,9 x 2,6 cm

  Mounting position ........................ :               Wall/Ceiling mounted equipment



 Report No: (NIE) 55234RRF.007                                       Page 4 of 23                                                 2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


  Modules/parts ............................. :          Module/parts of test item                       Type     Manufacturer

                                                         DirectKey                                    BLE Module Supra

  Accessories (not part of the test                      Description                                  Type        Manufacturer
  item) ............................................ :


  Documents as provided by the                           Description                                  File name   Issue date
  applicant ...................................... :
                                                         User manual

                                                         FW explanation document


(3) Only for Medical Equipment




Identification of the client
SALTO Systems, S.L.
Arkotz 9, Polígono Lanbarren
20180, Oiartzun, Gipuzkoa, SPAIN




Testing period and place
        Test Location                  DEKRA Testing and Certification S.A.U.
          Date (start)                 2018-01-11
         Date (finish)                 2018-11-06




Document history
   Report number                         Date                                           Description
   55234RRF.007                     2019-05-06           First release




Environmental conditions
     In the control chamber, the following limits were not exceeded during the test:

                                                                         Min. = 15 ºC
                 Temperature
                                                                         Max. = 35 ºC
                                                                         Min. = 20 %
                 Relative humidity
                                                                         Max. = 75 %
                 Shielding effectiveness                                 > 100 dB
                 Electric insulation                                     > 10 k
                 Reference resistance to earth                           <1


 Report No: (NIE) 55234RRF.007                                           Page 5 of 23                                    2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


    In the semianechoic chamber, the following limits were not exceeded during the test.

                                                             Min. = 15 ºC
                Temperature
                                                             Max. = 35 ºC
                                                             Min. = 20 %
                Relative humidity
                                                             Max. = 75 %
                                                             Min. = 860 mbar
                Air pressure
                                                             Max. = 1060 mbar
                Shielding effectiveness                      > 100 dB
                Electric insulation                          > 10 k
                Reference resistance to earth                <1
                                                             < ±4 dB at 10 m distance between item under test
                Normal site attenuation (NSA)
                                                             and receiver antenna, (30 MHz to 1000 MHz)
                                                             More than 75% of illuminated surface is between 0
                Field homogeneity
                                                             and 6 dB (26 MHz to 1000 MHz).


Remarks and comments
    The tests have been performed by the technical personnel: Miguel Angel Torres, José Alberto Aranda

    Used instrumentation:
           Radiated measurements:
                                                                              Last Calibration   Due Calibration

          1.      Semianechoic Absorber Lined Chamber ETS                          N.A.                N.A.
                  LINDGREN FACT 3 200 STP
          2.      EMI Receiver ROHDE AND SCHWARZ ESU40                           2018/06             2020/06
          3.      Active Loop Antenna HEWLETT PACKARD 11966A                     2018/06             2020/06
          4.      RF Pre-amplifier, 38 dB, 30 MHz-6 GHz BONN                     2018/07             2019/07
                  ELEKTRONIK BLNA 0360-01N
          5.      Biconical/Log Antenna 30 MHz - 6 GHz ETS                       2017/04             2020/04
                  LINDGREN 3142E
          6.      Signal and Spectrum Analyzer ROHDE AND                         2017/07             2019/07
                  SCHWARZ FSV40
          7.      RF Pre-amplifier, 40 dB ,1-18 GHz BONN                         2018/03             2019/03
                  ELEKTRONIK BLMA 0118-1M
          8.      Low Noise Amplifier G>30dB, 18 - 40 GHz BONN                   2018/02             2020/02
                  ELEKTRONIK BLMA 1840-1M
          9.      Broadband Horn antenna 1-18 GHz SCHWARZBECK                    2016/11             2019/11
                  MESS-ELEKTRONIK BBHA 9120 D
          10.     Broadband Horn antenna 18 - 40 GHz                             2018/07             2021/07
                  SCHWARZBECK MESS-ELEKTRONIK BBHA 9170
          11.     EMI Test Receiver 7 GHz ROHDE AND SCHWARZ                      2017/08             2019/08
                  ESR7
          12.     Biconical/Log Antenna 30 MHz - 6 GHz ETS                       2018/07             2021/07
                  LINDGREN 3142E
          13.     Signal and Spectrum Analyzer ROHDE AND                         2018/02             2020/02
                  SCHWARZ FSV 40
          14.     RF Pre-amplifier G>30dB, 1-18GHz BONN                          2018/03             2019/03
                  ELEKTRONIK BLMA 0118-3A
          15.     RF Pre-amplifier, G>48dB, 18-40GHz NARDA JS44-                 2018/02             2020/02
                  18004000-33-8P
          16.     Broadband Horn antenna 1-18 GHz SCHWARZBECK                    2018/01             2021/01
                  MESS-ELEKTRONIK BBHA 9120 D




 Report No: (NIE) 55234RRF.007                               Page 6 of 23                                        2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456



Testing verdicts

                                                   Not applicable:          N/A

                                                   Pass:                    P

                                                   Fail:                    F

                                                   Not measured:            N/M




Summary

                                                   FCC PART 15 / RSS-Gen PARAGRAPH
                                          Requirement – Test case                    Verdict   Remark
  15.209 Subclause (a) / RSS-Gen Clause 8.9. Transmitter emission limits               P
  Supplementary information and remarks:
  None.




 Report No: (NIE) 55234RRF.007                                       Page 7 of 23               2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix A: Test results.




 Report No: (NIE) 55234RRF.007                               Page 8 of 23   2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


                                                                            INDEX

TEST CONDITIONS ...................................................................................................................................................10
Section 15.209 Subclause (a) / RSS-Gen Clause 8.9. Transmitter emission limits ...................................................13




 Report No: (NIE) 55234RRF.007                                             Page 9 of 23                                                                2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


                                                             TEST CONDITIONS
POWER SUPPLY (V):

           Vn: 12 Vdc (*)
           Type of Power Supply: From CU42xx. (*)

           NFC:
                      Type of Antenna:                 Integral, PCB. (*)

           Bluetooth Low Energy:
                   Type of Antenna:                    Integral, Chip. (*)

(*): Declared by applicant.



TEST FREQUENCIES:

           NFC:
                      Nominal Operating Frequency: 13.56 MHz

           Bluetooth:
                   Low Channel:                        2402 MHz
                   Middle Channel:                     2440 MHz
                   High Channel:                       2480 MHz




RADIATED MEASUREMENTS:

All radiated tests were performed in a semi-anechoic chamber. The measurement antenna (Loop antenna) for the
range between 9 kHz to 30 MHz is situated at a distance of 3 m and the measurement antenna (Bilog antenna) for
the range between 30 MHz to 1000 MHz is situated at a distance of 3 m and at a distance of 1m for the frequency
range 1 GHz-26 GHz (1 GHz-18 GHz Double ridge horn antenna and 18 GHz-40 GHz horn antenna).

For radiated emissions in the range 9 kHz to 30 MHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 40 dB per decade is used to normalize the measured data for
determining compliance.

In the range between 9 kHz and 30 MHz the measurements were made in the three different orientation planes of
the loop antenna to determine the maximum received field.

The equipment under test was set up on a non-conductive platform above the ground plane and the situation and
orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna height
(Bilog antenna and Double ridge horn antenna) was varied from 1 to 4 meters to find the maximum radiated
emission.

For radiated emissions in the range 1 GHz-26 GHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for
determining compliance.

Measurements were made in both horizontal and vertical planes of polarization.
The test was performed with the equipment transmitting simultaneously with the 13.56 MHz radio and with the
Bluetooth Low Energy 2.4 GHz radio to check the impact of the co-location of the other radio interfaces. The results
and plots below show the worst results obtained.




 Report No: (NIE) 55234RRF.007                                      Page 10 of 23                         2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated measurements setup 9 kHz to 30 MHz.




Radiated measurements setup from 30 MHz to 1 GHz:




 Report No: (NIE) 55234RRF.007                               Page 11 of 23   2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


Radiated measurements setup f > 1 GHz:




 Report No: (NIE) 55234RRF.007                               Page 12 of 23   2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


       Section 15.209 Subclause (a) / RSS-Gen Clause 8.9. Transmitter emission limits

SPECIFICATION:

Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the
field strength levels specified in the following table (see §15.205(c) / RSS-Gen):

                  Frequency Range                 Field strength (µV/m)            Field strength   Measurement
                       (MHz)                                                         (dBµV/m)       distance (m)
                      0.009-0.490                       2400/F(kHz)                      -              300
                      0.490-1.705                      24000/F(kHz)                      -              30
                      1.705 - 30.0                           30                        29.54            30
                         30 - 88                             100                        40               3
                        88 - 216                             150                       43.5              3
                       216 - 960                             200                        46               3
                      Above 960                              500                        54               3



RESULTS:

The spectrum was inspected from 9 kHz to 26 GHz searching for spurious signals.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer. This
correction factor includes antenna factor, cable loss and pre-amplifier gain.




 Report No: (NIE) 55234RRF.007                                     Page 13 of 23                                   2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- FREQUENCY RANGE 9 kHz – 30 MHz:

          NFC mode ISO 14443A with Bluetooth Low Energy

      No spurious frequencies at less than 20 dB below the limit.




                                  The highest peak corresponds to the NFC mode ISO 14443A carrier level.


Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz
The scan is performed with the peak detector.
The limits shown in the above plot are extrapolated to 3 meters.




 Report No: (NIE) 55234RRF.007                                 Page 14 of 23                               2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693 with Bluetooth Low Energy

      No spurious frequencies at less than 20 dB below the limit.




                                   The highest peak corresponds to the NFC mode ISO 15693carrier level.


Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz
The scan is performed with the peak detector.
The limits shown in the above plot are extrapolated to 3 meters.




 Report No: (NIE) 55234RRF.007                                 Page 15 of 23                              2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- FREQUENCY RANGE 30 MHz – 1 GHz

          NFC mode ISO 14443A with Bluetooth Low Energy

           Spurious at less than 20 dB of the limit:

              Spurious frequency                   Detector      Emission Level        Polarization         Measurement
                    (MHz)                                          (dBµV/m)                                Uncertainty (dB)
                   324.977                       Quasi peak          37.3                    V                <± 3.88
                   350.003                       Quasi peak          30.6                    V                <± 3.88
                   424.984                       Quasi peak          40.6                    V                <± 3.88
                   500.013                       Quasi peak          33.9                    V                <± 3.88
                   524.991                       Quasi peak          33.5                    V                <± 3.88
                   550.017                       Quasi peak          30.4                    V                <± 3.88
                   699.979                       Quasi peak          34.0                    V                <± 3.88
                   800.034                       Quasi peak          34.5                    H                <± 3.88
                   900.041                       Quasi peak          35.4                    H                <± 3.88
                   950.045                       Quasi peak          29.7                    H                <± 3.88




                                       The above plot shows the results of the scan using peak detector.




Verdict: PASS




 Report No: (NIE) 55234RRF.007                                   Page 16 of 23                                                2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693 with Bluetooth Low Energy

           Spurious at less than 20 dB of the limit:

              Spurious frequency                   Detector      Emission Level        Polarization         Measurement
                    (MHz)                                          (dBµV/m)                                Uncertainty (dB)
                    36.515                       Quasi peak          25.8                    V                <± 3.88
                   230.548                       Quasi peak          29.6                    H                <± 3.88
                   311.898                       Quasi peak          35.7                    H                <± 3.88
                   366.121                       Quasi peak          42.6                    V                <± 3.88
                   393.240                       Quasi peak          33.0                    V                <± 3.88
                   488.180                       Quasi peak          28.9                    V                <± 3.88




                                       The above plot shows the results of the scan using peak detector.




Verdict: PASS




 Report No: (NIE) 55234RRF.007                                   Page 17 of 23                                                2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


- FREQUENCY RANGE 1 – 26 GHz

          NFC mode ISO 14443A with Bluetooth Low Energy

           No spurious emissions at less than 20 dB below the limit.

      Verdict: PASS



      FREQUENCY RANGE 1 - 3 GHz:




                                                 The peak above the limit is the carrier frequency.




 Report No: (NIE) 55234RRF.007                                     Page 18 of 23                      2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


      FREQUENCY RANGE 3 - 17 GHz:




      FREQUENCY RANGE 17 - 26 GHz:

      The spurious signals detected do not depend on the operating channel.




 Report No: (NIE) 55234RRF.007                               Page 19 of 23    2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


      FREQUENCY RANGE 2.31-2.39 GHz (Restricted Band 1):




      FREQUENCY RANGE 2.4835-2.5 GHz (Restricted Band 2):




 Report No: (NIE) 55234RRF.007                               Page 20 of 23   2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


          NFC mode ISO 15693 with Bluetooth Low Energy

           The spurious frequencies do not depend on the operating channel.

           Spurious at less than 20 dB of the limit:

              Spurious frequency                   Detector        Emission Level         Polarization    Measurement
                    (GHz)                                            (dBµV/m)                            Uncertainty (dB)
                       4.8795                        Peak                39.17                  V            <±3.70
                      12.1987                        Peak                50.09                  H            <±3.70


      Verdict: PASS



      FREQUENCY RANGE 1 - 3 GHz:




                                                 The peak above the limit is the carrier frequency.




 Report No: (NIE) 55234RRF.007                                     Page 21 of 23                                            2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


      FREQUENCY RANGE 3 - 17 GHz:




      FREQUENCY RANGE 17 - 26 GHz:

      The spurious signals detected do not depend on the operating channel.




 Report No: (NIE) 55234RRF.007                               Page 22 of 23    2019-05-06


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


      FREQUENCY RANGE 2.31-2.39 GHz (Restricted Band 1):




      FREQUENCY RANGE 2.4835-2.5 GHz (Restricted Band 2):




 Report No: (NIE) 55234RRF.007                               Page 23 of 23   2019-05-06



Document Created: 2019-05-06 12:42:58
Document Modified: 2019-05-06 12:42:58

© 2024 FCC.report