RF exposure evaluation - W0S - v2

FCC ID: UKCW0B

RF Exposure Info

Download: PDF
FCCID_3906240

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




                                                                                               Test report No:
                                                                                            NIE: 53898RAN.007


          Assessment report
          FCC 47 CFR Part 2.1091
          ISED RSS-102 Issue 5:2015

           Identification of item tested                     Electronic Lock Series including all mechanical variants


           Trademark                                         XS4 Original


           Model and /or type reference                      W0S


           Other identification of the product               FCC ID: UKCW0B
                                                             IC: 10088A-W0B
           Features                                          Not provided data


           Applicant                                         SALTO Systems, S.L.
                                                             Arkotz 9, Polígono Lanbarren
                                                             20180, Oiartzun, Gipuzkoa, SPAIN
           Test method requested, standard                   FCC 47 CFR Part 2.1091 Radiofrequency radiation
                                                             exposure evaluation: mobile devices.
                                                             ISED RSS-102 Issue 5 (2015-03) – Radio Frequency
                                                             Exposure Compliance of Radiocommunication
                                                             Apparatus (All Frequency Bands)

           Summary                                           IN COMPLIANCE


           Approved by (name / position & signature)         Miguel Lacave
                                                                                                      MIGUEL LACAVE
                                                             Antennas Lab Manager                     GARCÍA
                                                                                                      2018.06.27
                                                                                                      14:23:05 +02'00'

           Date of issue                                     2018-06-27


           Report template No                                FAN24_01




Report No: (NIE) 53898RAN.007                                                                                       2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




    Index
    Competences and guarantees .................................................................................................... 3
    General conditions ...................................................................................................................... 3
    Identification of the client............................................................................................................. 3
    General description of the device under evaluation ..................................................................... 4
    Assessment summary................................................................................................................. 5
    Appendix A: FCC RF Exposure................................................................................................... 6
         FCC RF Exposure evaluation for mobile devices.................................................................... 7
         FCC MPE Evaluation Results ................................................................................................. 8
    Appendix B: ISED RF Exposure................................................................................................ 12
         ISED RF Exposure evaluation for mobile devices................................................................. 13
         ISED MPE Evaluation Results .............................................................................................. 14




 Report No: (NIE) 53898RAN.007                                      Page 2 of 17                                                          2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Competences and guarantees
    In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and
    maintenance program for its measurement equipment.
    DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements
    and the tests performed to the item under test on the date and under the conditions stated on the report and, it
    is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test.
    DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under
    test and the results of the test.
    The results presented in this Assessment Report apply only to the particular item under test established in this
    document.
    IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
    except in full, without the previous written permission of DEKRA.


General conditions
         1. This report is only referred to the item that has undergone the assessment.
         2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies
            or competent Authorities.
         3. This document is only valid if complete; no partial reproduction can be made without previous written
            permission of DEKRA.
         4. This assessment report cannot be used partially or in full for publicity and/or promotional purposes
            without previous written permission of DEKRA and the Accreditation Bodies.


Identification of the client
    SALTO Systems, S.L.
    Arkotz 9, Polígono Lanbarren
    20180, Oiartzun, Gipuzkoa, SPAIN




 Report No: (NIE) 53898RAN.007                               Page 3 of 17                                      2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




General description of the device under evaluation
   The device under evaluation consists of an electronic lock series, with different model variants, which uses the
   same main board and can support NFC and Bluetooth Smart technologies. The electronic and batteries will be
   installed inside the door. During its normal use the separation distance between the antenna and the user will be
   greater than 20 cm.



                                                                              Supported Features
                                                                                                     Bluetooth
                        Model                   NFC ISO 14443-A                 NFC ISO 15693
                                                                                                   Smart Direct Key
                XS4 Original W0S                             Yes                      Yes                Yes
                                                               Table 1: Supported features



   The equipment specifications declared by the manufacturer for each supported feature are:

                                                                                  Maximum Maximum radiated
                        Band                                     Maximum RF
                                         Technology                              antenna gain power (E.I.R.P.)
                        (MHz)                                 output power (dBm)
                                                                                     (dBi)       (dBm)
                  13.553-13.567              NFC                       25.0                 N/A         25.0
                  2402.0-2480.0            Bluetooth                    2.8                 0.5          3.3
                                                             Table 2: Equipment specifications




 Report No: (NIE) 53898RAN.007                                         Page 4 of 17                                   2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




Assessment summary

                                                 Radiofrequency radiation exposure limits

                                       FCC 47 CFR § 2.1091 & ISED RSS-102 Issue 5 (2015-03)

                                                                 Band                        VERDICT
                                         Assessment                           Technology
                                                                 (MHz)                      (Pass/Fail)
                                                 1                13.5             NFC         Pass
                                                 2                2450          Bluetooth      Pass
                                                             Table 3: Assessment summary




 Report No: (NIE) 53898RAN.007                                           Page 5 of 17                     2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix A: FCC RF Exposure




 Report No: (NIE) 53898RAN.007                               Page 6 of 17   2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




FCC RF Exposure evaluation for mobile devices
   Devices operating in standalone mobile device exposure conditions may contain a single transmitter or multiple
   transmitters that do not transmit simultaneously. A minimum test separation distance ≥ 20 cm is required
   between the antenna and radiating structures of the device and nearby persons to apply mobile device
   exposure limits. The distance must be at least 20 cm and fully supported by the operating and installation
   configurations of the transmitter and its antenna(s), according to the source-based time-averaged maximum
   power requirements of § 2.1091(d)(2). In cases where cable losses or other attenuations are applied to
   determine compliance, the most conservative operating configurations and exposure conditions must be
   evaluated. The minimum test separation distance required for a device to comply with mobile device exposure
   conditions must be clearly identified in the installation and operating instructions, for all installation and
   exposure conditions, to enable users and installers to comply with RF exposure requirements. For mobile
   devices that have the potential to operate in portable device exposure conditions, similar to the configurations
   described in § 2.1091(d)(4), a KDB inquiry is required to determine the SAR test requirements for
   demonstrating compliance.
   When a device qualifies for the categorical exclusion provision of § 2.1091(c), the minimum test separation
   distance may be estimated, when applicable, by simple calculations according to plane-wave equivalent
   conditions, to ensure the transmitter and its antenna(s) can operate in manners that meet or exceed the
   estimated distance. The source-based time-averaged maximum radiated power, according to the maximum
   antenna gain, must be applied to calculate the field strength and power density required to establish the
   minimum test separation distance. When the estimated test separation distance becomes overly conservative
   and does not support compliance, MPE measurement or computational modeling may be used to determine the
   required minimum separation distance.
   According to §1.1310 Radiofrequency radiation exposure limits, paragraph (e), the limits for Maximum
   Permissible Exposure (MPE) to radiofrequency electromagnetic fields are:




 Report No: (NIE) 53898RAN.007                               Page 7 of 17                                 2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




FCC MPE Evaluation Results
   Each supported transmission technology will be evaluated to determine if it is in compliance with limits for
   Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic fields.

   In order to perform the assessment, the following equations have been used for the calculations; these
   equations are accurate in the far-field of an antenna and will over-predict power density in the near field, where
   they could be used for making a "worst case" or conservative prediction:

                                               PE .I .R.P. [mW ]
   Power density: S[mW / cm 2 ] 
                                                4R[cm]2


                                                                    PE .I .R.P. [mW ]
   Minimum compliance distance: R min [cm] 
                                                                   4S[mW / cm 2 ]

   Where:
    S = power density
    PE . I . R.P. = Equivalent isotropically radiated power
    R = distance to the center of radiation of the antenna (evaluation distance)
    Rmin = distance to the center of radiation of the antenna




 Report No: (NIE) 53898RAN.007                                          Page 8 of 17                        2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Assessment 1 – NFC – 13.5 MHz Band

     Maximum output power (dBm):                                             25.0
     Maximum antenna Gain (dBi):                                             N/A
     Minimum use distance (cm):                                              20.0
     Worst Case Frequency (MHz):                                            13.56
     Maximum EIRP (dBm):                                                     25.0
     Maximum EIRP (mW):                                                     316.23
     General population - Power density limit (mW/cm 2):                     0.98

   Power density at minimum use distance:

     Power density (mW/cm 2):                                               0.063
     General population - Power density limit (mW/cm 2):                     0.98
     Verdict for general population:                                        PASS

   The power density level for this transmission mode is below general population exposure power density limit.

   Minimum compliance distance for this technology:

     Minimum compliance distance for general population (cm):                5.07
     Minimum use distance (cm):                                              20.0
     Verdict for general population:                                        PASS

   The minimum use distance is greater than general population exposure minimum compliance distance.




 Report No: (NIE) 53898RAN.007                               Page 9 of 17                                 2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Assessment 2 – Bluetooth Smart Direct Key – 2450 MHz Band

     Maximum output power (dBm):                                               2.8
     Maximum antenna Gain (dBi):                                               0.5
     Minimum use distance (cm):                                               20.0
     Worst Case Frequency (MHz):                                             2402.0
     Maximum EIRP (dBm):                                                       3.3
     Maximum EIRP (mW):                                                       2.14
     General population - Power density limit (mW/cm 2):                       1.0

   Power density at minimum use distance:

     Power density (mW/cm2):                                                 0.0004
     General population - Power density limit (mW/cm 2):                       1.0
     Verdict for general population:                                         PASS

   The power density level for this transmission mode is below general population exposure power density limit.

   Minimum compliance distance for this technology:

     Minimum compliance distance for general population (cm):                 0.41
     Minimum use distance (cm):                                               20.0
     Verdict for general population:                                         PASS

   The minimum use distance is greater than general population exposure minimum compliance distance.




 Report No: (NIE) 53898RAN.007                               Page 10 of 17                                2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


 Multiple frequencies assessment
  When multiple sources are introduced into an environment, it becomes necessary to address the sources
  interdependently, since each source will contribute some percentage of the maximum exposure toward the
  total exposure at a fixed location. The sum of the ratios of the exposure from each source to the
  corresponding maximum exposure for the frequency of each source must be evaluated.

   The exposure complies with the maximum permissible exposure if the sum of the ratios is less than unity:

                                                              n
                                                                         Si
                                                                                 <1
                                                             i 1    MPE      i


   Where
   Si    is the power density of each source;
   MPEi is the power density basic restriction of each source.


    This device is able to transmit simultaneously using NFC and Bluetooth Smart. The multiple frequencies
    calculation will be as follow:


                                          0.063 0.0004
                                               +       =            0.064 + 0.0004 = 0.065 < 1 Limit
                                          0.98     1




 Report No: (NIE) 53898RAN.007                                      Page 11 of 17                        2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




      Appendix B: ISED RF Exposure




 Report No: (NIE) 53898RAN.007                               Page 12 of 17   2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




ISED RF Exposure evaluation for mobile devices
   According to RSS-102 Issue 5, Paragraph “4. Exposure Limits”, Industry of Canada has adopted the RF field
   strength limits stablished in Healths Canada’s RF exposure guideline, Safety code 6:




 Report No: (NIE) 53898RAN.007                               Page 13 of 17                             2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456




ISED MPE Evaluation Results
   Each supported transmission technology will be evaluated to determine if it is in compliance with RSS-102
   Issue 5, RF Field Strength Limits for devices used by the General Public.

   In order to perform the assessment, the following equations have been used for the calculations; these
   equations are accurate in the far-field of an antenna and will over-predict power density in the near field, where
   they could be used for making a "worst case" or conservative prediction:



                                          PE .I .R. P.[W ]
   Power density: S [W / m 2 ] 
                                          4R[m]2
                                                              PE . I . R. P. [W ]
   Minimum compliance distance: Rmin [ m] 
                                                             4 S [W / m 2 ]

   Where:
    S = power density
    PE . I . R.P. = Equivalent isotropically radiated power
    R = distance to the center of radiation of the antenna (evaluation distance)
    Rmin = distance to the center of radiation of the antenna




 Report No: (NIE) 53898RAN.007                                       Page 14 of 17                          2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Assessment 1 – NFC – 13.5 MHz Band

     Maximum output power (dBm):                                             25.0
     Maximum antenna gain (dBi):                                              N/A
     Minimum use distance (m):                                                0.2
     Worst Case Frequency (MHz):                                             13.56
     Maximum EIRP (dBm):                                                     25.0
     Maximum EIRP (W):                                                       0.32
     General public - Power density limit (W/m 2):                            2.0

   Power density at minimum use distance:

     Power density (W/m 2):                                                   0.63
     General public - Power density limit (W/m 2):                             2.0
     Verdict for general public:                                             PASS

   The power density level for this transmission mode is below general public power density limit.

   Minimum compliance distance for this technology:

     Minimum compliance distance for general public (m):                     0.112
     Minimum use distance (m):                                                0.2
     Verdict for general public:                                             PASS

   The minimum use distance is greater than general public minimum compliance distance.




 Report No: (NIE) 53898RAN.007                               Page 15 of 17                           2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Assessment 2 – Bluetooth Smart Direct Key – 2450 MHz Band

     Maximum output power (dBm):                                               2.8
     Maximum antenna gain (dBi):                                               0.5
     Minimum use distance (m):                                                 0.2
     Worst Case Frequency (MHz):                                             2402.0
     Maximum EIRP (dBm):                                                       3.3
     Maximum EIRP (W):                                                       0.0021
     General public - Power density limit (W/m 2):                            5.35

   Power density at minimum use distance:

     Power density (W/m 2):                                                  0.004
     General public - Power density limit (W/m 2):                            5.35
     Verdict for general public:                                             PASS

   The power density level for this transmission mode is below general public power density limit.

   Minimum compliance distance for this technology:

     Minimum compliance distance for general public (m):                     0.006
     Minimum use distance (m):                                                0.2
     Verdict for general public:                                             PASS

   The minimum use distance is greater than general public minimum compliance distance.




 Report No: (NIE) 53898RAN.007                               Page 16 of 17                           2018-06-27


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España
C.I.F. A29 507 456


   Multiple frequencies assessment

   When multiple sources are introduced into an environment, it becomes necessary to address the sources
   interdependently, since each source will contribute some percentage of the maximum exposure toward the
   total exposure at a fixed location. The sum of the ratios of the exposure from each source to the
   corresponding maximum exposure for the frequency of each source must be evaluated.

   The exposure complies with the maximum permissible exposure if the sum of the ratios is less than unity:

                                                              n
                                                                         Si
                                                                                 <1
                                                             i 1     MPE     i


   Where
   Si    is the power density of each source;
   MPEi is the power density basic restriction of each source.

    This device is able to transmit simultaneously using NFC and Bluetooth Smart. The multiple frequencies
    calculation will be as follow:


                                             0.63 0.016
                                                 +      =           0.315 + 0.001 = 0.316 < 1 Limit
                                              2    5.35




 Report No: (NIE) 53898RAN.007                                      Page 17 of 17                        2018-06-27



Document Created: 2018-06-27 14:23:05
Document Modified: 2018-06-27 14:23:05