53898RRF019s

FCC ID: UKCW0B

Test Report

Download: PDF
FCCID_3906236

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



                                                                                        FCC LISTED, REGISTRATION                    Informe de ensayo nº:
                                                                                        NUMBER: 720267
                                                                                                                                       Test report No:
                                                                                        ISED LISTED REGISTRATION
                                                                                        NUMBER 4621A-2                              NIE: 53898RRF.019


                                                                                    Partial Test report
                             REFERENCE STANDARD:
               USA FCC Part 15.225 and Part 15.209 & CANADA RSS-210
           Identificación del objeto ensayado ......................:                   Electronic Lock Series including all mechanical variants
           Identification of item tested

           Marca ...................................................................:   XS4 Original
           Trademark

           Modelo y/o referencia tipo ..................................:               W09W (Type reference : E0102)
           Model and /or type reference

           Other identification of the product ....................:                    FCC ID: UKCW0B
                                                                                        IC: 10088A-W0B
           Final HW version ................................................:           1.0
           Final SW version .................................................:          Control Firmware: 0016
                                                                                        Reader Firmware: 0132
                                                                                        RF2MODULE Firmware: 0038
           Características .....................................................:       Contains FCC ID: UKCRF2MODULE
           Features
                                                                                        Contains IC: 10088A-RF2MODULE
           Solicitante .............................................................:   SALTO Systems, S.L.
           Applicant
                                                                                        Arkotz 9, Polígono Lanbarren
                                                                                        20180, Oiartzun, Gipuzkoa, SPAIN
           Método de ensayo solicitado, norma ...................:                      USA FCC Part 15.225 (10–1–17 Edition): Operation within the band
           Test method requested, standard                                              13.110 -14.010.
                                                                                        USA FCC Part 15.209 (10–1–17 Edition): Radiated emission limits,
                                                                                        general requirements.
                                                                                        CANADA RSS-210 Issue 9 (August 2016).
                                                                                        CANADA RSS-Gen Issue 4 (November 2014).
                                                                                        ANSI C63.10-2013: American National Standard for Testing Unlicensed
                                                                                        Wireless Devices.
                                                                                            - Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field
                                                                                                 strength of emissions within the band 13.553 MHz -13.567
                                                                                                 MHz
                                                                                            - Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field
                                                                                                 strength of emissions within the band 13.410 MHz -13.553
                                                                                                 MHz and 13.567 MHz -13.710 MHz
                                                                                            - Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field
                                                                                                 strength of emissions within the band 13.110 MHz -13.410
                                                                                                 MHz and 13.710 MHz -14.010 MHz
                                                                                            - Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field
                                                                                                 strength of emissions outside of the band 13.110 MHz -14.010
                                                                                                 MHz


Report No: (NIE)
53898RRF.019                                                                                                                                       2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



           Aprobado por (nombre / cargo y firma) ...........:                  A. Llamas
           Approved by (name / position & signature)                                             Firmado digitalmente
                                                                               RF Lab. Manager   por ALEJANDRO
                                                                                                 LLAMAS RODRIGUEZ
                                                                                                 Fecha: 2018.06.06
                                                                                                 15:31:38 +02'00'
           Fecha de realización ...........................................:   2018-05-15
           Date of issue

           Formato de informe No. ......................................:      FDT08_20
           Report template No




Report No: (NIE)
53898RRF.019                                                                      Page 2 of 19                    2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




       Index
   Competences and guarantees .........................................................................................................................4
   General conditions .........................................................................................................................................4
   Uncertainty ....................................................................................................................................................4
   Usage of samples ...........................................................................................................................................5
   Test sample description .................................................................................................................................5
   Identification of the client .............................................................................................................................5
   Testing period ................................................................................................................................................5
   Environmental conditions..............................................................................................................................5
   Remarks and comments .................................................................................................................................6
   Testing verdicts .............................................................................................................................................7
   Appendix A – Test result...............................................................................................................................8




Report No: (NIE)
53898RRF.019                                                                  Page 3 of 19                                                                     2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Competences and guarantees
   DEKRA Testing and Certification is a testing laboratory accredited by the National Accreditation Body (ENAC -
   Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
   DEKRA Testing and Certification is a laboratory with a measurement facility in compliance with the requirements of
   Section 2.948 of the FCC rules and has been added to the list of facilities whose measurements data will be accepted
   in conjuction with applications for Certification under Parts 15 or 18 of the Commission's Rules. Registration
   Number: 720267.
   DEKRA Testing and Certification is a laboratory with a measurement site in compliance with the requirements of
   RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian Certification and
   Engineering Bureau. Reference File Number: ISED 4621A-2.
   In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification
   has a calibration and maintenance program for its measurement equipment.
   DEKRA Testing and Certification guarantees the reliability of the data presented in this report, which is the result of
   the measurements and the tests performed to the item under test on the date and under the conditions stated on the
   report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification at the
   time of performance of the test.
   DEKRA Testing and Certification is liable to the client for the maintenance of the confidentiality of all information
   related to the item under test and the results of the test.
   The results presented in this Test Report apply only to the particular item under test established in this document.
   IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
   except in full, without the previous written permission of DEKRA Testing and Certification.

   General conditions
       1. This report is only referred to the item that has undergone the test.
       2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
          competent Authorities.
       3. This document is only valid if complete; no partial reproduction can be made without previous written permission of
          DEKRA Testing and Certification.
       4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written
          permission of DEKRA Testing and Certification and the Accreditation Bodies.

   Uncertainty
   Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification internal document PODT000.




Report No: (NIE)
53898RRF.019                                                 Page 4 of 19                                                 2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Usage of samples
   Samples undergoing test have been selected by: the client
       Sample S/01 is composed of the following elements:

       Control Nº                     Description                 Model              Serial Nº   Date of reception

       53898B/009                   Electronic lock           W09W / E0102              ---         2017-08-18

       53898B/036                        Module               RF2MODULE                 ---         2017-11-08
                                     IEEE802.15.4

       1. Sample S/01 has undergone following test(s).
            All tests indicated in appendix A.




   Test sample description
   The sample consists of a New XS4 Original, with Mifare and IEEE802.15.4 technology.



   Identification of the client
   SALTO Systems, S.L.
   Arkotz 9, Polígono Lanbarren
   20180, Oiartzun, Gipuzkoa, SPAIN



   Testing period
   The performed test started on 2017-11-14 and finished on 2017-12-05.
   The tests have been performed at DEKRA Testing and Certification.




   Environmental conditions
   In the control chamber, the following limits were not exceeded during the test:


                                                             Min. = 15 ºC
             Temperature
                                                             Max. = 35 ºC
                                                             Min. = 20 %
             Relative humidity
                                                             Max. = 75 %
             Shielding effectiveness                         > 100 dB




Report No: (NIE)
53898RRF.019                                                 Page 5 of 19                                  2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   In the semianechoic chamber, the following limits were not exceeded during the test.

                                                             Min. = 15 ºC
              Temperature
                                                             Max. = 35 ºC
                                                             Min. = 20 %
              Relative humidity
                                                             Max. = 75 %
                                                             Min. = 860 mbar
              Air pressure
                                                             Max. = 1060 mbar
              Shielding effectiveness                        > 100 dB
                                                             < ±4 dB at 10 m distance between item under test and
              Normal site attenuation (NSA)
                                                             receiver antenna, (30 MHz to 1000 MHz)
                                                             More than 75% of illuminated surface is between 0 and 6
              Field homogeneity
                                                             dB (26 MHz to 1000 MHz).




   Remarks and comments
   1: Tests have been performed by the technical personnel: Pedro Parada.
   2: Test not requested.
   3: Used instrumentation.

       Radiated Measurements

                                                                            Last Cal. date   Cal. due date
                 Semianechoic Absorber Lined Chamber ETS
         1.                                                                     N.A.             N.A.
                 FACT3 200STP
         2.      BiconicalLog antenna ETS LINDGREN 3142E                      2015/09          2018/09
         3.      Multi Device Controller EMCO 2090                             N.A.             N.A.
         4.      EMI Test Receiver R&S ESU 26                                 2016/02          2018/02
         5.      RF pre-amplifier 30 MHz-6 GHz Bonn Elektronik
                                                                              2017/09          2018/09
                 BLNA 0160-01N
         6.      Loop antenna HP 1196 A.                                      2016/05          2018/05
         7.      Antenna tripod EMCO 11968C.                                   N.A.             N.A.




Report No: (NIE)
53898RRF.019                                                 Page 6 of 19                                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Testing verdicts

                          Not applicable ......................................................................... :           N/A

                          Pass .......................................................................................... :     P

                          Fail ........................................................................................... :    F

                          Not measured .......................................................................... :            N/M




                            FCC PART 15/RSS-210 PARAGRAPH                                                                            VERDICT
                                                                                                                               NA     P   F NM
15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within                                                     P
                      the band 13.553 MHz -13.567 MHz
15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within                                                    P
                      the band 13.410 - 13.553 MHz and 13.567 – 13.710 MHz
15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within                                                    P
                      the band 13.110 - 13.410 MHz and 13.710 – 14.010 MHz
15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside                                                   P
                      of the band 13.110 MHz -14.010 MHz
15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier                                                              NM2
                      signal
2: See section “Remarks and comments”.




Report No: (NIE)
53898RRF.019                                                                      Page 7 of 19                                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Appendix A – Test result




Report No: (NIE)
53898RRF.019                                                 Page 8 of 19   2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




                                                                                   INDEX

     TEST CONDITIONS .......................................................................................................................................................... 10

     Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within the band 13.553 MHz -13.567
     MHz ..................................................................................................................................................................................... 12

     Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within the band 13.410 MHz -13.553
     MHz and 13.567 MHz -13.710 MHz................................................................................................................................... 13

     Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within the band 13.110 MHz -13.410
     MHz and 13.710 MHz -14.010 MHz................................................................................................................................... 15

     Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside of the band 13.110 MHz -
     14.010 MHz ......................................................................................................................................................................... 17




Report No: (NIE)
53898RRF.019                                                                          Page 9 of 19                                                                               2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




                                                             TEST CONDITIONS
     Vnominal = 4.5 Vdc
     Vmin = N/A
     Vmax = N/A
The subscripts nom, min and max indicate voltage test conditions (nominal, minimum and maximum respectively,
as declared by the applicant).
N/A: Not Applicable
Type of power supply = DC voltage from batteries.
Type of antenna = Integral antenna

Operating Temperature Range (ºC):
          Tnom = +15 to + 35


TEST FREQUENCIES:
Nominal Operating frequency: 13.56 MHz


OPERATION MODES:
The equipment under test can operate with two NFC modes: NFC ISO 14443A and NFC ISO 15693. Only
NFC ISO 14443A mode was tested.


RADIATED MEASUREMENTS
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna (Loop antenna for the
range between 9 kHz to 30 MHz and Bilog antenna for the range between 30 MHz to 140 MHz) is situated at a
distance of 3 m.
For radiated emissions in the range 9 kHz to 30 MHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 40 dB per decade is used to normalize the measured data for
determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation and
orientation was varied to find the maximum radiated emission. It was also rotated 360º and in the range between 30
MHz and 140 MHz the antenna height was varied from 1 to 4 meters to find the maximum radiated emission.
In the range between 9 kHz and 30 MHz the measurements were made in the three different orientation planes of
the loop antenna to determine the maximum received field.
In the range between 30 MHz and 140 MHz the measurements were made in both horizontal and vertical planes of
polarization.
The test was performed with the equipment transmitting first with only the 13.56 MHz radio and repeated with the
2.4 GHz 802.15.4 radio transmitting simultaneously to check the impact of the co-location of the other radio
interfaces. The results and plots below show the worst results obtained.




Report No: (NIE)
53898RRF.019                                                     Page 10 of 19                          2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




Radiated measurements setup 9 kHz to 30 MHz.




Radiated measurements setup 30 MHz to 140 MHz.




Report No: (NIE)
53898RRF.019                                                 Page 11 of 19   2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




 Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within the band
                                     13.553 MHz -13.567 MHz

SPECIFICATION

The field strength of any emissions within the band 13.553 – 13.567 MHz shall not exceed 15,848 microvolts/meter
(84 dBµV/m) at 30 meters.


RESULTS

Measurement distance: 3 meters




                                Note: The limit shown in the above plot is extrapolated to 3 meters

        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.561                                        52.34                                  12.34
 Measurement uncertainty (dB)                                                    <±3.61




Verdict: PASS




Report No: (NIE)
53898RRF.019                                                     Page 12 of 19                                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




 Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within the band
                     13.410 MHz -13.553 MHz and 13.567 MHz -13.710 MHz


SPECIFICATION

Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not exceed
334 microvolts/meter (50.47 dBµV/m) at 30 meters.


RESULTS
Band 13.410-13.553 MHz

Measurement distance: 3 meters.




                                Note: The limit shown in the above plot is extrapolated to 3 meters

        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.553                                        38.80                                   -1.20
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS




Report No: (NIE)
53898RRF.019                                                     Page 13 of 19                                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




Band 13.567-13.710 MHz

Measurement distance: 3 meters.




                                Note: The limit shown in the above plot is extrapolated to 3 meters



        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.567                                        38.28                                   -1.72
 Measurement uncertainty (dB)                                                    <±3.61



Verdict: PASS




Report No: (NIE)
53898RRF.019                                                     Page 14 of 19                                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




 Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within the band
                     13.110 MHz -13.410 MHz and 13.710 MHz -14.010 MHz

SPECIFICATION

Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz, the field strength of any emissions shall not exceed
106 microvolts/meter (40.51 dBµV/m) at 30 meters.

RESULTS

Band 13.110-13.410 MHz

Measurement distance: 3 meters.




                                Note: The limit shown in the above plot is extrapolated to 3 meters

        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.350                                        34.27                                   -5.73
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS




Report No: (NIE)
53898RRF.019                                                     Page 15 of 19                                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




Band 13.710-14.010 MHz

Measurement distance: 3 meters.




                                Note: The limit shown in the above plot is extrapolated to 3 meters



        Frequency (MHz)                     Maximum field strength (dBµV/m)               Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)         extrapolated to 30 m (40 dB/decade)
               13.770                                        35.10                                      3.72
 Measurement uncertainty (dB)                                                    ±3.61



Verdict: PASS




Report No: (NIE)
53898RRF.019                                                     Page 16 of 19                                                 2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




  Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside of the
                                  band 13.110 MHz -14.010 MHz

SPECIFICATION

Field strength of any emissions appearing outside of the band 13.110 MHz - 14.010 MHz band shall not exceed the
general radiated emission limits in 15.209/RSS-Gen:

    Frequency Range                Field strength (µV/m)        Field strength   Measurement
         (MHz)                                                   (dBµV/m)        distance (m)
       0.009-0.490                       2400/F(kHz)                    -            300
       0.490-1.705                      24000/F(kHz)                    -            30
       1.705 - 30.0                             30                   29.54           30
           30 - 88                             100                     40             3
          88 - 216                             150                    43.5            3
         216 - 960                             200                     46             3
        Above 960                              500                     54             3



RESULTS:
All tests were performed in a semi-anechoic chamber at a distance of 3 m.
The spectrum was inspected from 9 kHz to 140 MHz searching for spurious signals.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer. This
correction factor includes antenna factor, cable loss and pre-amplifier gain.
The test was performed with the equipment transmitting first with only the 13.56 MHz radio and repeated with the
IEEE802.15.4 radios transmitting simultaneously to check the impact of the co-location of the other radio
interfaces. The results and plots below show the worst results obtained.



Frequency range 9 kHz-30 MHz.

No spurious signals were found at less than 20 dB below the limit.


Frequency range 30 MHz-140 MHz.

No spurious signals were found at less than 20 dB below the limit.

Verdict: PASS




Report No: (NIE)
53898RRF.019                                                 Page 17 of 19                               2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



FREQUENCY RANGE 9 kHz-30 MHz.




Note: The limits shown in the above plot are extrapolated to 3 meters. The highest peak corresponds to the carrier
level.

Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz




Report No: (NIE)
53898RRF.019                                                 Page 18 of 19                              2018-05-15


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



FREQUENCY RANGE 30 MHz to 140 MHz.




Note: The above plot shows the results of the scan using peak detector.




Report No: (NIE)
53898RRF.019                                                 Page 19 of 19   2018-05-15



Document Created: 2018-06-06 15:31:38
Document Modified: 2018-06-06 15:31:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC