53613RRF006A2s

FCC ID: UKCAF0B

Test Report

Download: PDF
FCCID_3828857

DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



                                                                                        FCC LISTED, REGISTRATION                    Informe de ensayo nº:
                                                                                        NUMBER: 720267
                                                                                                                                       Test report No:
                                                                                        ISED LISTED REGISTRATION
                                                                                        NUMBER 4621A-2                             NIE: 53613RRF.006A2


                                                                 Test report (Modification II)
                             REFERENCE STANDARD:
               USA FCC Part 15.225 and Part 15.209 & CANADA RSS-210
           Identificación del objeto ensayado ......................:                   Electronic Lock Series including all mechanical variants
           Identification of item tested

           Marca ...................................................................:   AElement Fusion
           Trademark

           Modelo y/o referencia tipo ..................................:               AF0D (Type reference: E1723)
           Model and /or type reference

           Other identification of the product ....................:                    FCC ID: UKCAF0B
                                                                                        IC: 10088A-AF0B
           Final HW version ................................................:           1.0
           Final SW version .................................................:          0146 (Control Firmware) + 0136 (BGM111 Firmware)
           Características .....................................................:       Contains 2 certified Bluetooth modules (BGM111 & DirectKey)
           Features

           Solicitante .............................................................:   SALTO Systems, S.L.
           Applicant
                                                                                        Arkotz 9, Polígono Lanbarren
                                                                                        20180, Oiartzun, Gipuzkoa, SPAIN
           Método de ensayo solicitado, norma ...................:                      USA FCC Part 15.225 (10–1–17 Edition): Operation within the band
           Test method requested, standard                                              13.110 -14.010.
                                                                                        USA FCC Part 15.209 (10–1–17 Edition): Radiated emission limits,
                                                                                        general requirements.
                                                                                        CANADA RSS-210 Issue 9 (August 2016).
                                                                                        CANADA RSS-Gen Issue 4 (November 2014).
                                                                                        ANSI C63.10-2013: American National Standard for Testing Unlicensed
                                                                                        Wireless Devices.
           Resultado ..............................................................:    IN COMPLIANCE
           Summary

           Aprobado por (nombre / cargo y firma) ...........:                           A. Llamas
           Approved by (name / position & signature)
                                                                                                                                   Firmado digitalmente
                                                                                        RF Lab. Manager                            por ALEJANDRO
                                                                                                                                   LLAMAS RODRIGUEZ
                                                                                                                                   Fecha: 2018.04.24
                                                                                                                                   14:38:02 +02'00'
           Fecha de realización ...........................................:            2018-04-20
           Date of issue

           Formato de informe No. ......................................:               FDT11_20
           Report template No




Report No: (NIE)
53613RRF.006A2                                                                                                                                      2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




       Index
   Competences and guarantees .........................................................................................................................3
   General conditions .........................................................................................................................................3
   Uncertainty ....................................................................................................................................................3
   Usage of samples ...........................................................................................................................................4
   Test sample description .................................................................................................................................4
   Identification of the client .............................................................................................................................4
   Testing period ................................................................................................................................................4
   Environmental conditions..............................................................................................................................5
   Modifications to the reference test report ......................................................................................................6
   Remarks and comments .................................................................................................................................6
   Testing verdicts .............................................................................................................................................7
   Appendix A – Test result...............................................................................................................................8




Report No: (NIE)
53613RRF.006A2                                                                Page 2 of 30                                                                     2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Competences and guarantees
   DEKRA Testing and Certification is a testing laboratory accredited by the National Accreditation Body (ENAC -
   Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
   DEKRA Testing and Certification is a laboratory with a measurement facility in compliance with the requirements of
   Section 2.948 of the FCC rules and has been added to the list of facilities whose measurements data will be accepted
   in conjuction with applications for Certification under Parts 15 or 18 of the Commission's Rules. Registration
   Number: 720267.
   DEKRA Testing and Certification is a laboratory with a measurement site in compliance with the requirements of
   RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian Certification and
   Engineering Bureau. Reference File Number: ISED 4621A-2.
   In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification
   has a calibration and maintenance program for its measurement equipment.
   DEKRA Testing and Certification guarantees the reliability of the data presented in this report, which is the result of
   the measurements and the tests performed to the item under test on the date and under the conditions stated on the
   report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification at the
   time of performance of the test.
   DEKRA Testing and Certification is liable to the client for the maintenance of the confidentiality of all information
   related to the item under test and the results of the test.
   The results presented in this Test Report apply only to the particular item under test established in this document.
   IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
   except in full, without the previous written permission of DEKRA Testing and Certification.

   General conditions
       1. This report is only referred to the item that has undergone the test.
       2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
          competent Authorities.
       3. This document is only valid if complete; no partial reproduction can be made without previous written permission of
          DEKRA Testing and Certification.
       4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written
          permission of DEKRA Testing and Certification and the Accreditation Bodies.

   Uncertainty
   Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification internal document PODT000.




Report No: (NIE)
53613RRF.006A2                                               Page 3 of 30                                                 2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Usage of samples
   Samples undergoing test have been selected by: the client
       Sample S/01 is composed of the following elements:

       Control Nº                     Description                 Model              Serial Nº   Date of reception

       53613B/017            PCB with antenna conector               ---                ---         2017-10-23

       53613B/018                        Module                      ---                ---         2017-10-23

       1. Sample S/01 has undergone following test(s).
            All conducted tests indicated in appendix A (mode NFC-A).


       Sample S/02 is composed of the following elements:

       Control Nº                     Description                 Model              Serial Nº   Date of reception

       53613B/013                   Electronic lock                AF0D                 ---         2017-09-28

       1. Sample S/02 has undergone following test(s).
            All radiated tests indicated in appendix A (mode NFC-A).


       Sample S/03 is composed of the following elements:

       Control Nº                     Description                 Model              Serial Nº   Date of reception

       53613B/029                   Electronic lock                AF0D                 ---         2018-03-22

       53613B/001                       Lock case                    ---                ---         2017-07-20

       1. Sample S/02 has undergone following test(s).
            All radiated and conducted tests indicated in appendix A (mode NFC-V).



   Test sample description
   The test sample consists of a new AElement reader with Mifare/NFC-V and Bluetooth Smart (BGM111 & DirectKey)
   technology. Electronic and batteries inside the door.



   Identification of the client
   SALTO Systems, S.L.
   Arkotz 9, Polígono Lanbarren
   20180, Oiartzun, Gipuzkoa, SPAIN



   Testing period
   The performed test started on 2017-10-20 and finished on 2018-04-19.
   The tests have been performed at DEKRA Testing and Certification.
Report No: (NIE)
53613RRF.006A2                                               Page 4 of 30                                  2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Environmental conditions

   In the control chamber, the following limits were not exceeded during the test:


                                                             Min. = 15 ºC
             Temperature
                                                             Max. = 35 ºC
                                                             Min. = 20 %
             Relative humidity
                                                             Max. = 75 %
             Shielding effectiveness                         > 100 dB




   In the semianechoic chamber, the following limits were not exceeded during the test.

                                                             Min. = 15 ºC
             Temperature
                                                             Max. = 35 ºC
                                                             Min. = 20 %
             Relative humidity
                                                             Max. = 75 %
                                                             Min. = 860 mbar
             Air pressure
                                                             Max. = 1060 mbar
             Shielding effectiveness                         > 100 dB
                                                             < ±4 dB at 10 m distance between item under test and
             Normal site attenuation (NSA)
                                                             receiver antenna, (30 MHz to 1000 MHz)
                                                             More than 75% of illuminated surface is between 0 and 6
             Field homogeneity
                                                             dB (26 MHz to 1000 MHz).



   In the chamber for conducted measurements, the following limits were not exceeded during the test:

             Temperature                                      Min. = 15 ºC
                                                              Max. = 35 ºC
             Relative humidity                                Min. = 20 %
                                                              Max. = 75 %
             Air pressure                                     Min. = 860 mbar
                                                              Max. = 1060 mbar
             Shielding effectiveness                          > 100 dB




Report No: (NIE)
53613RRF.006A2                                               Page 5 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Modifications to the reference test report
   It was introduced the following modifications in respect to the test report number 53613RRF.006A1 related with the same
   samples, in the next clauses and sub-clauses:

           Clauses / Sub-clauses                                 Modification                                    Justification

              Usage of Samples                                Added sample S/03                      New measurements for NFC-V mode

                Testing period                                Modified finish date                   New measurements for NFC-V mode

      Remarks and comments/Used                              Added instrumentation                   New measurements for NFC-V mode
           instrumentation

         Appendix A – Test result                        Added mode NFC-V results                    New measurements for NFC-V mode

        Appendix B – Photographs                    Added photographs of mode NFC-V                  New measurements for NFC-V mode
                                                                samples

   This modification test report cancels and replaces the test report 53613RRF.006A1.



   Remarks and comments
   1: Tests have been performed by the technical personnel: Carlos Alberto Contreras, Gonzalo Rueda and José Alberto
   Aranda.
   2: Used instrumentation.

       Conducted Measurements

                                                                               Last Cal. date        Cal. due date
         1.      Spectrum analyser Agilent E4440A                                2017/10               2019/10
         2.      Climatic chamber HERAEUS VM 04/35                               2016/03               2018/03
         3.      DC power supply R&S NGPE 40/40                                  2018/02               2021/02
         4.      Vector Signal analyser R&S FSQ8                                 2016/06               2018/06
         5.      Spectrum analyser Rohde & Schwarz FSV40                         2017/07               2019/07



       Radiated Measurements

                                                                                    Last Cal. date   Cal. due date
                 Semianechoic Absorber Lined Chamber ETS
         1.                                                                             N.A.             N.A.
                 FACT3 200STP
         2.      BiconicalLog antenna ETS LINDGREN 3142E                              2015/09          2018/09
         3.      Multi Device Controller EMCO 2090                                     N.A.             N.A.
         4.      EMI Test Receiver R&S ESU 26                                         2018/02          2020/02
         5.      RF pre-amplifier 30 MHz-6 GHz Bonn Elektronik
                                                                                      2017/07          2018/07
                 BLNA 0360-01N
         6.      Loop antenna HP 1196 A.                                              2016/05          2018/05
         7.      Antenna tripod EMCO 11968C.                                           N.A.             N.A.




Report No: (NIE)
53613RRF.006A2                                                       Page 6 of 30                                                2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



   Testing verdicts

                          Not applicable ......................................................................... :           N/A

                          Pass .......................................................................................... :     P

                          Fail ........................................................................................... :    F

                          Not measured .......................................................................... :            N/M




                            FCC PART 15/RSS-210 PARAGRAPH                                                                            VERDICT
                                                                                                                               NA     P   F NM
15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within                                                     P
                      the band 13.553 MHz -13.567 MHz
15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within                                                     P
                      the band 13.410 - 13.553 MHz and 13.567 – 13.710 MHz
15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within                                                     P
                      the band 13.110 - 13.410 MHz and 13.710 – 14.010 MHz
15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside                                                    P
                      of the band 13.110 MHz -14.010 MHz
15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier                                                         P
                      signal




Report No: (NIE)
53613RRF.006A2                                                                    Page 7 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




   Appendix A – Test result




Report No: (NIE)
53613RRF.006A2                                               Page 8 of 30   2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España


                                                                                   INDEX

     TEST CONDITIONS .......................................................................................................................................................... 10

     Occupied Bandwidth ........................................................................................................................................................... 13

     Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within the band 13.553 MHz -13.567
     MHz ..................................................................................................................................................................................... 15

     Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within the band 13.410 MHz -13.553
     MHz and 13.567 MHz -13.710 MHz................................................................................................................................... 17

     Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within the band 13.110 MHz -13.410
     MHz and 13.710 MHz -14.010 MHz................................................................................................................................... 20

     Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside of the band 13.110 MHz -
     14.010 MHz ......................................................................................................................................................................... 24

     Section 15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier signal ......................................... 30




Report No: (NIE)
53613RRF.006A2                                                                        Page 9 of 30                                                                               2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




                                                             TEST CONDITIONS


Power supply (V):
     Vnominal = 4.5 Vdc
     Vmin = 3.825 Vdc
     Vmax = 5.175 Vdc


The subscripts nom, min and max indicate voltage test conditions (nominal, minimum and maximum respectively,
as declared by the applicant).
Type of power supply = DC voltage from batteries.
Type of antenna = Integral antenna

Operating Temperature Range (ºC):
          Tnom = +15 to + 35




TEST FREQUENCIES:
Nominal Operating frequency: 13.56 MHz


CONDUCTED MEASUREMENTS
The equipment under test was set up in a shielded room and it is directly connected to the spectrum analyser or
using a coupling device.




Report No: (NIE)
53613RRF.006A2                                                   Page 10 of 30                            2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




For frequency stability test the EUT was placed inside a climatic chamber and connected to a frequency meter
using a low loss cable. An external DC power supply was connected to the EUT for voltage variation test.




RADIATED MEASUREMENTS
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna (Loop antenna for the
range between 9 kHz to 30 MHz and Bilog antenna for the range between 30 MHz to 200 MHz) is situated at a
distance of 3 m.
For radiated emissions in the range 9 kHz to 30 MHz that is performed at a distance closer than the specified
distance, an inverse proportionality factor of 40 dB per decade is used to normalize the measured data for
determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation and
orientation was varied to find the maximum radiated emission. It was also rotated 360º and in the range between 30
MHz and 200 MHz the antenna height was varied from 1 to 4 meters to find the maximum radiated emission.
In the range between 9 kHz and 30 MHz the measurements were made in the three different orientation planes of
the loop antenna to determine the maximum received field.
In the range between 30 MHz and 200 MHz the measurements were made in both horizontal and vertical planes of
polarization.


The test was performed with the equipment transmitting first with only the 13.56 MHz radio and repeated with the
2.4 GHz BT LE radio transmitting simultaneously to check the impact of the co-location of the other radio
interfaces. The results and plots below show the worst results obtained.




Report No: (NIE)
53613RRF.006A2                                               Page 11 of 30                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




Radiated measurements setup 9 kHz to 30 MHz.




Radiated measurements setup 30 MHz to 200 MHz.




Report No: (NIE)
53613RRF.006A2                                               Page 12 of 30   2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




                                                             Occupied Bandwidth



RESULTS
99 % Occupied Bandwidth (see next plots).


             Operation mode                        99% occupied bandwith (kHz)
                    NFC-A                                       517.628
                    NFC-V                                       107.850
   Measurement uncertainty (kHz)                                <±6.01



NFC-A




Report No: (NIE)
53613RRF.006A2                                                    Page 13 of 30   2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




NFC-V




Report No: (NIE)
53613RRF.006A2                                               Page 14 of 30   2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




 Section 15.225 Subclause (a) / RSS-210 Clause B.6 (a). Field strength of emissions within the band
                                     13.553 MHz -13.567 MHz

SPECIFICATION

The field strength of any emissions within the band 13.553 – 13.567 MHz shall not exceed 15,848 microvolts/meter
(84 dBµV/m) at 30 meters.


RESULTS

Measurement distance: 3 meters

NFC-A




                                Note: The limit shown in the above plot is extrapolated to 3 meters

        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.561                                        58.24                                  18.24
 Measurement uncertainty (dB)                                                    <±3.61

Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 15 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




NFC-V




                                Note: The limit shown in the above plot is extrapolated to 3 meters

        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.561                                        59.70                                  19.70
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 16 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




 Section 15.225 Subclause (b) / RSS-210 Clause B.6 (b). Field strength of emissions within the band
                     13.410 MHz -13.553 MHz and 13.567 MHz -13.710 MHz


SPECIFICATION

Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall not exceed
334 microvolts/meter (50.47 dBµV/m) at 30 meters.


RESULTS

Band 13.410-13.553 MHz

Measurement distance: 3 meters.

NFC-A




                                Note: The limit shown in the above plot is extrapolated to 3 meters

        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.454                                        44.23                                   4.23
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS


Report No: (NIE)
53613RRF.006A2                                                   Page 17 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España


NFC-V




                                Note: The limit shown in the above plot is extrapolated to 3 meters


        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.553                                        44.53                                   4.53
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 18 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




Band 13.567-13.710 MHz

Measurement distance: 3 meters.

NFC-A




                                Note: The limit shown in the above plot is extrapolated to 3 meters



        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.567                                        44.83                                   4.83
 Measurement uncertainty (dB)                                                    <±3.61



Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 19 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




NFC-V




                                Note: The limit shown in the above plot is extrapolated to 3 meters



        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.567                                        45.63                                   5.63
 Measurement uncertainty (dB)                                                    <±3.61



Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 20 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



 Section 15.225 Subclause (c) / RSS-210 Clause B.6 (c). Field strength of emissions within the band
                     13.110 MHz -13.410 MHz and 13.710 MHz -14.010 MHz

SPECIFICATION

Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz, the field strength of any emissions shall not exceed
106 microvolts/meter (40.51 dBµV/m) at 30 meters.

RESULTS

Band 13.110-13.410 MHz

Measurement distance: 3 meters.

NFC-A




                                Note: The limit shown in the above plot is extrapolated to 3 meters


        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.350                                        41.00                                   1.00
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 21 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España


NFC-V




                                Note: The limit shown in the above plot is extrapolated to 3 meters


        Frequency (MHz)                     Maximum field strength (dBµV/m)            Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)      extrapolated to 30 m (40 dB/decade)
               13.402                                        21.30                                  -18.70
 Measurement uncertainty (dB)                                                    <±3.61


Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 22 of 30                                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




Band 13.710-14.010 MHz

Measurement distance: 3 meters.

NFC-A




                                Note: The limit shown in the above plot is extrapolated to 3 meters



        Frequency (MHz)                     Maximum field strength (dBµV/m)               Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)         extrapolated to 30 m (40 dB/decade)
               13.774                                        40.55                                      0.55
 Measurement uncertainty (dB)                                                    ±3.61



Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 23 of 30                                                 2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España


NFC-V




                                Note: The limit shown in the above plot is extrapolated to 3 meters



        Frequency (MHz)                     Maximum field strength (dBµV/m)               Maximum field strength (dBµV/m)
                                           measured at 3 m (quasi-peak detector)         extrapolated to 30 m (40 dB/decade)
               13.718                                        20.69                                     -19.31
 Measurement uncertainty (dB)                                                    ±3.61



Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                   Page 24 of 30                                                 2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




  Section 15.225 Subclause (d) / RSS-210 Clause B.6 (d). Field strength of emissions outside of the
                                  band 13.110 MHz -14.010 MHz

SPECIFICATION

Field strength of any emissions appearing outside of the band 13.110 MHz - 14.010 MHz band shall not exceed the
general radiated emission limits in 15.209/RSS-Gen:

    Frequency Range                Field strength (µV/m)         Field strength         Measurement
         (MHz)                                                    (dBµV/m)              distance (m)
       0.009-0.490                       2400/F(kHz)                     -                    300
       0.490-1.705                      24000/F(kHz)                     -                    30
       1.705 - 30.0                             30                    29.54                   30
           30 - 88                             100                      40                     3
          88 - 216                             150                     43.5                    3
         216 - 960                             200                      46                     3
        Above 960                              500                      54                     3



RESULTS:
All tests were performed in a semi-anechoic chamber at a distance of 3 m.
The spectrum was inspected from 9 kHz up to at least the 10th harmonic searching for spurious signals.
The field strength is calculated by adding correction factor to the measured level from the spectrum analyzer. This
correction factor includes antenna factor, cable loss and pre-amplifier gain.


NFC-A

Frequency range 9 kHz-30 MHz.

No spurious signals were found at less than 20 dB below the limit.


Frequency range 30 MHz-200 MHz

             Spurious frequency                Polarization       Detector        Emission Level  Measurement
                   (MHz)                                                            (dBµV/m)     Uncertainty (dB)
                      67.80                           V         Quasi-peak            24.74             3.88
                      81.37                           V         Quasi-peak            27.33             3.88



Verdict: PASS



Report No: (NIE)
53613RRF.006A2                                                Page 25 of 30                                         2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



FREQUENCY RANGE 9 kHz-30 MHz.




Note: The limits shown in the above plot are extrapolated to 3 meters. The highest peak corresponds to the carrier
level.

Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz




Report No: (NIE)
53613RRF.006A2                                               Page 26 of 30                              2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España



FREQUENCY RANGE 30 MHz to 200 MHz.




Note: The above plot shows the results of the scan using peak detector.




Report No: (NIE)
53613RRF.006A2                                               Page 27 of 30   2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España


NFC-V

Frequency range 9 kHz-30 MHz.

No spurious signals were found at less than 20 dB below the limit.



Frequency range 30 MHz-140 MHz

             Spurious frequency                Polarization       Detector    Emission Level  Measurement
                   (MHz)                                                        (dBµV/m)     Uncertainty (dB)
                      30.308                          V         Quasi-peak        19.80            3.88
                      34.455                          V         Quasi-peak        19.10            3.88



Verdict: PASS

FREQUENCY RANGE 9 kHz-30 MHz.




Note: The limits shown in the above plot are extrapolated to 3 meters. The highest peak corresponds to the carrier
level.

Resolution bandwidth:
200 Hz for 9 kHz ≤ f ≤ 150 kHz
9 kHz for 150 kHz ≤ f ≤ 30 MHz



Report No: (NIE)
53613RRF.006A2                                                Page 28 of 30                                     2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




FREQUENCY RANGE 30 MHz to 140 MHz.




Note: The above plot shows the results of the scan using peak detector.




Report No: (NIE)
53613RRF.006A2                                               Page 29 of 30   2018-04-20


DEKRA Testing and Certification, S.A.U.
Parque Tecnológico de Andalucía,
c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España




     Section 15.225 Subclause (e) / RSS-210 Clause B.6. Frequency tolerance of the carrier signal


SPECIFICATION

The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating frequency over
a temperature variation of –20 degrees to +50 degrees C at normal supply voltage, and for a variation in the
primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For hand
carried, battery powered equipment, reduce primary supply voltage to the battery operating end point which shall
be specified by the manufacturer.



RESULTS

Nominal operating frequency: 13.56 MHz

Mode: unmodulated carrier
Frequency stability over temperature variations.

Temperature (ºC) Frequency Error (Hz) Frequency Error (%)
     +50                 174               0.001286
     +40                 190               0.001402
     +30                 205               0.001513
     +20                 276               0.002036
     +10                 266               0.001963
      0                  275               0.002025
     -10                 270               0.001992
     -20                 276               0.002036




Frequency stability over voltage variations.

  DC Supply voltage               Voltage (V) Frequency Error (Hz)            Frequency Error
                                                                                   (%)
           Vmax                        5.175                 312                 0.002298
           Vmin                        3.825                 175                 0.001287




Verdict: PASS




Report No: (NIE)
53613RRF.006A2                                                Page 30 of 30                             2018-04-20



Document Created: 2018-04-24 14:38:02
Document Modified: 2018-04-24 14:38:02

© 2024 FCC.report