MPE

FCC ID: UDX-62009015

RF Exposure Info

Download: PDF
FCCID_1081172

                                                                                     Sheet1




Meraki MR58

FCC ID: UDX-62009015

802.11n AP                                                               Calculate mW/cm2 here. Enter frequency in MHz:

RF Hazard Distance Calculation                                           Calculation of Limits from 1.1310 Table 1
                                                                                                                     Controlled  Uncontrolled
                                                                                                                     Ave 6 min   Ave 30 min
mW/cm2 from Table1:           1.00                                           F(MHz)        Actual F, MHz              Occ, mW/c2 Gen, mW/cm
                                                                              0.3-3             0.5                      100.0       100.0
Max RF PoweTX Antenna    MPE distance S, mW/cm@      Comment               3.0 - 30.0            5                       180.0        36.0
P, dBm     G, dBi        cm           at 20 cm                              30.0-300            55                        1.0          0.2
                                                                           300-1500            902                        3.0         0.60
   21.87         3.00          4.9          0.06     2.4 GHz mono         1500-100000          5555                       5.0          1.0
   21.87          2.5          4.7          0.05     2.4 GHz dual
   21.87         11.5         13.1          0.43     2.4 GHz HV
   17.00         19.0         17.8          0.79     2.4 GHz panel       Enter P(mW)      Equivalent dBm Enter dBmEquivalent Watts
   21.17          4.0          5.1          0.07     5GHz mono
   21.17          5.0          5.7          0.08     5GHz dual mono
   21.17         14.5         17.1          0.73     5 GHz HV
   21.17         23.0         45.6          5.20     5 GHz panel




Basis of Calculations:                                                   1000             30.00            30.00           1000.0

E^2/3770 = S, mW/cm2
E, V/m = (Pwatts*Ggain*30)^.5/d, meters
d = ((Pwatts*G*30)/3770*S))^0.5         Pwatts*Ggain = 10^(PdBm-30+GdBi)/10)
S@20cm = 20 log (MPE dist/20cm)
NOTE: For mobile or fixed location transmitters, minimum separation distance is for FCC compliance is 20 cm,
        even if calculations indicate MPE distance is less




                                                                                     Page 1



Document Created: 2009-03-13 13:42:38
Document Modified: 2009-03-13 13:42:38

© 2024 FCC.report