Reply Letter

FCC ID: UDX-60057010

Cover Letter(s)

Download: PDF
FCCID_3832633

Timco Engineering, Inc

From:                               andrea.hsia@tw.bureauveritas.com
Sent:                               Friday, April 20, 2018 4:28 AM
To:                                 cb@timcoengr.com
Cc:                                 andrea.hsia@tw.bureauveritas.com
Subject:                            Re: SUBJECT: TIMCO-TCB/Desk Aduit - CISCO SYSTEMS INC. - FCC ID: UDX-60057010 -
                                    JOB #: 2534ATC16-2534BTC16
Attachments:                        Test Report (NII)_rev 2.pdf; Theory of Operation (Antenna spec-Ant. 20)_rev 2.pdf;
                                    Theory of Operation (Antenna spec-Ant. 21 V)_rev 2.pdf; Theory of Operation (Antenna
                                    spec-Ant. 25 V)_rev 2.pdf; Theory of Operation (Antenna spec-Ant. 27 V)_rev 2.pdf;
                                    Theory of Operation (Antenna spec-AIR-ANT2513P4M-N Azimuth)_rev 2.pdf; Theory of
                                    Operation (Antenna spec-AIR-ANT2513P4M-N Elevation)_rev 2.pdf; Users Manual_rev
                                    2.pdf


Hi Sirs,

Please refer to as below for our reply.

Please kindly help us to review it, if have no any further question please submit to FCC.

Thank you so much.

1. The 21dBm at above 30 degree restriction is not added to the test report.
BV TW: We modified p154~174 of NII report.

(See attached file: Test Report (NII)_rev 2.pdf)

2. Checking your response, how to achieve and maintain the 21dBm at above 30 degree was not addressed. This
should be clearly described in the test report and user/installation manual.

BV TW: We modified p11~12 of NII report. Also modified antenna pattern to you.




Due to device Will restriced installation position as above photo, thus consider to above 30 degrees highest antenna gain
are chosen from XZ and YZ Plane (antenna specification of 60~-60 dug and 120~-120 dug)
(See attached file: Theory of Operation (Antenna spec-Ant. 20)_rev 2.pdf)




                                                             1


Due to device Will restriced installation position as above photo, thus consider to above 30 degrees highest antenna gain
are chosen from XZ and YZ Plane (antenna specification of 30~180 dug)
(See attached file: Theory of Operation (Antenna spec-Ant. 21 V)_rev 2.pdf)




Due to device Will restriced installation position as above photo, thus consider to above 30 degrees highest antenna gain
are chosen from XZ and YZ Plane (antenna specification of 60~180 dug and -150~-180 dug)
(See attached file: Theory of Operation (Antenna spec-Ant. 25 V)_rev 2.pdf)




                                                            2


Due to device Will restriced installation position as above photo, thus consider to above 30 degrees highest antenna gain
are chosen from XZ and YZ Plane (antenna specification of 30~180 dug)

(See attached file: Theory of Operation (Antenna spec-Ant. 27 V)_rev 2.pdf)




Due to device Will restriced installation position as above photo, thus consider to above 30 degrees highest antenna gain
are chosen from Azimuth and Elevation Plane (antenna specification of 0~30 dug and 210~360 dug)

(See attached file: Theory of Operation (Antenna spec-AIR-ANT2513P4M-N Azimuth)_rev 2.pdf)(See attached
file: Theory of Operation (Antenna spec-AIR-ANT2513P4M-N Elevation)_rev 2.pdf)




                                                            3


Due to device Will restriced installation position as above photo, thus consider to above 30 degrees highest antenna gain
are chosen from Max Gain

3. Who is responsible for installation, user or professional installer? If professional, is there any training?

        BV TW: Please refer to as below for client's reply.
        Regarding the further examination of professional installation here are our replies:
        The equipment will be installed by professional installers. These installers are associated with the
        Meraki sales partners/distributers. Since Meraki does not sell its devices directly to users, partners are
        responsible for the final install of the equipment.
        There is no formal training for installers, however each Meraki partner and subsequent install must
        follow the instructions in the official Meraki installation guide. This is a condition for distribution.

4. The manual should be detailed and specific about the restriction.
       BV TW: Client modified the manual and reply as below.
       I have updated the install guide to address the rule explanations as well as how we limit the power for
       band 1. See section 6 in the attached guide. Specific reference to our software defined radio usage.

(See attached file: Users Manual_rev 2.pdf)

4. It appears this device is Point-to-Multipoint (P2M)? Therefore, please address KDB 789033 D02,
particularly, section H

        BV TW: Please refer to as below for client's reply.
        For outdoor operation of the AP in the 5150-5250 MHz band, the maximum output
        power shall not exceed 1W. EIRP at any elevation angle above 30 degrees (as measured from
        the horizon) shall not exceed 125mW, per the FCC Part 15.407 rules. The highest antenna gains
        from the horizon above 30 degrees are as below:




                                                            4


       And the following condition for maximum EIRP must apply:
       and shall not exceed 21 dBm above 30 degrees over the horizon. This is maintained through the
       Cisco Meraki Software Defined Radio implementation, limiting the power output at a given
       band, limiting the maximum EIRP for 5150-5250 MHz to 21 dBm when implemented
       outdoors. All power limits and band usage according to FCC rules are implemented through
       the SDR.


5. In the test report, both indoor/outdoor is mentioned. Mixed indoor/outdoor is not allowed unless
professionally installed.
         BV TW: Please refer to as below for client's reply.
It is professionally installed


Best Regards,

Andrea Hsia, Certification Div.
Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch
                                                       5


Tel: +886-3-318-3232 (ext. 1628); Skype: whs9681
eMail: andrea.hsia@tw.bureauveritas.com
Web : www.bureauveritas-adt.com



  "Timco Engineering, Inc" ---2018/03/26 上午 11:57:50---TIMCO ENGINEERING INC.                                     Product Testing
and Certification

From: "Timco Engineering, Inc" <cb@timcoengr.com>
To: Annie Cheng/TWN/VERITAS@VERITAS, Andrea Hsia/TWN/VERITAS@VERITAS, Miffy Tsao/TWN/VERITAS@VERITAS, Amanda
Wu/TWN/VERITAS@VERITAS, Emily Lin/TWN/VERITAS@VERITAS, Ida Chen/TWN/VERITAS@VERITAS
Date: 2018/03/26 上午 11:57
Subject: SUBJECT: TIMCO-TCB/Desk Aduit - CISCO SYSTEMS INC. - FCC ID: UDX-60057010 - JOB #: 2534ATC16-2534BTC16




TIMCO ENGINEERING INC.                                               Product Testing and Certification
849 NW State Road 45 Newberry FL 32669                                        FCC Approvals
888.472.2424 or 352 472 5500 F 352.472.2030                           Industry Canada Approvals
              www.timcoengr.com                                          Notified Body for Europe
Certification : cb@timcoengr.com                                              Product Safety Approvals
Testing   : testing@timcoengr.com                                    Australian Testing


03/25/2018

Ms. Anne Kuo
BUREAU VERITAS CONSUMER PRODUCTS SERVICES H.K. LTD
886-3-318-3232 886-3-327-0892


annie.cheng@tw.bureauveritas.com;andrea.hsia@tw.bureauveritas.com;miffy.tsao@tw.bureauveritas.com;aman
da.wu@tw.bureauveritas.com;emily.lin@tw.bureauveritas.com;ida.chen@tw.bureauveritas.com



SUBJECT: TIMCO-TCB/Desk Aduit - CISCO SYSTEMS INC. - FCC ID: UDX-60057010 - JOB #:
2534ATC16-2534BTC16

Dear Ms. Kuo:

We received a second RT for FCC ID: UDX-60057010, please find the email from FCC below. Kindly
note the FCC requires they received a reply within 30 days.


Date of Original E-mail:
03/23/2018

We checked the response. However, the issues weren’t addressed adequately.

1. The 21dBm at above 30 degree restriction is not added to the test report.
2. Checking your response, how to achieve and maintain the 21dBm at above 30 degree was not addressed. This

                                                                 6


should be clearly described in the test report and user/installation manual.
3. Who is responsible for installation, user or professional installer? If professional, is there any training?
4. The manual should be detailed and specific about the restriction.
4. It appears this device is Point-to-Multipoint (P2M)? Therefore, please address KDB 789033 D02,
particularly, section H
5. In the test report, both indoor/outdoor is mentioned. Mixed indoor/outdoor is not allowed unless
professionally installed.

Sincerely,

Timco Engineering, Inc.




"This message contains confidential information.

To know more, please click on the following link: http://disclaimer.bureauveritas.com"




                                                          7



Document Created: 2018-04-27 15:48:02
Document Modified: 2018-04-27 15:48:02

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC