RF Exposure Info (MPE)

FCC ID: UDX-60053010

RF Exposure Info

Download: PDF
FCCID_3501324

                                                           RF Exposure Report

                       Report No.: SA170314C06A

                            FCC ID: UDX-60053010

                       Test Model: Z3-HW

                 Received Date: Mar. 14, 2017

                         Test Date: Mar. 27 ~ May 03, 2017

                     Issued Date: May 09, 2017


                         Applicant: Cisco Systems, Inc.

                          Address: 170 West Tasman Drive, San Jose, CA 95134



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA170314C06A                                             Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 170314C06, 170314C07


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA170314C06A                                             Page No. 2 / 6                                              Report Format Version: 6.1.1
Reference No.: 170314C06, 170314C07


                                          Release Control Record


Issue No.              Description                                        Date Issued
SA170314C06A           Original release                                   May 09, 2017




Report No.: SA170314C06A                     Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 170314C06, 170314C07


1    Certificate of Conformity


            Product: 802.11a/b/g/n/ac Wireless Security Appliance

              Brand: Cisco

        Test Model: Z3-HW

    Sample Status: Engineering sample

          Applicant: Cisco Systems, Inc.

          Test Date: Mar. 27 ~ May 03, 2017

         Standards: FCC Part 2 (Section 2.1091)
                        KDB 447498 D03 (January 17, 2014)
                        IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:        May 09, 2017
                             Pettie Chen / Senior Specialist




     Approved by :                                               , Date:        May 09, 2017
                                Ken Liu / Senior Manager




Report No.: SA170314C06A                        Page No. 4 / 6                       Report Format Version: 6.1.1
Reference No.: 170314C06, 170314C07


2     RF Exposure
2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field     Magnetic Field       Power Density         Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)              (minutes)
                             Limits For General Population / Uncontrolled Exposure
       300-1500                   …                    …                  F/1500                  30
      1500-100,000                …                    …                   1.0                    30
F = Frequency in MHz


2.2     MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3     Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA170314C06A                       Page No. 5 / 6                        Report Format Version: 6.1.1
Reference No.: 170314C06, 170314C07


3     Calculation Result of Maximum Conducted Power
Frequency Band         Max Power          Antenna Gain            Distance      Power Density              Limit
    (MHz)                (dBm)                (dBi)                 (cm)          (mW/cm2)               (mW/cm2)
WLAN
CDD mode
     2412-2462            26.26               8.15                  20              0.549                     1
     5180-5240            21.65               8.52                  20              0.207                     1
     5260-5320            22.12               8.52                  20              0.231                     1
     5500-5700            22.60               8.52                  20              0.257                     1
     5745-5825            21.81               8.52                  20              0.215                     1
Beamforming mode
     2412-2462            20.46               8.15                  20              0.144                     1
     5180-5240            18.64               8.52                  20              0.103                     1
     5260-5320            19.11               8.52                  20              0.115                     1
     5500-5700            19.59               8.52                  20              0.129                     1
     5745-5825            18.79               8.52                  20              0.107                     1
BT LE
   2402-2480            5.13              2.66                     20                 0.001                   1
Note:
2.4GHz Band: Directional gain = 10 log[(10G1 /20 + 10G2 /20 + ... + 10GN /20)2/2] = 8.15dBi
5GHz Band: Directional gain = 10 log[(10G1 /20 + 10G2 /20 + ... + 10GN /20)2/2]= 8.52 dBi


                                           Max Power (dBm)                          Total Power          Power Limit
    Frequency Band
                                  WLAN                            BT LE               (dBm)                (dBm)

       2.4GHz                     26.26                            5.13                 26.29                 30

CONCULSION:
Both of the WLAN 2.4G & WLAN 5G & BT LE can transmit simultaneously, the formula of calculated the MPE
is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density
WLAN 2.4G + WLAN 5.0G + BT LE = 0.549 + 0.257 + 0.001 = 0.807
Therefore, the maximum calculation of this situation is 0.807, which is less than the “1” limit.