Part 15.207/ 15.209 Wireless Charger Emissions (Phone on wireless charger)

FCC ID: UCE312057A

Test Report

Download: PDF
FCCID_1857239

                                      T T REP
                                      TEST  PORT
                                               T
               Test Report No. : UL-RPT-R
                                        RP9038
                                             85JD11A
                                                   A V2.0
        urer
Manufactu                     :    Pan
                                     nasonic Mo
                                              obile Communications Developme
                                                                   D         nt of Europe Ltd

Model No..                    :    NTT
                                     T docomo Wireless
                                              W         harger Pad P02 & PSU
                                                       Ch                  U P02

FCC ID                        :    UC
                                    CE312057A



         dard(s)
Test Stand                    :    FCC Parts 15.207 & 15.209




1.     Thiss test report shall
                         s     not be reproduced
                                      r             in full or partiial, without th
                                                                                  he written ap
                                                                                              pproval of
       RFI Global Services Ltd trading as UL.
2.     The results in this report appply only to thee sample(s) tested.
                                                                    t
3.     Thiss sample testted is in commpliance with the above standard(s).
4.     The test results in this reportt are traceable to the natiional or interrnational stan ndards.
5.     Verssion 2.0 supe ersedes all previous
                                     p          verssions.


                          Date of Issue:                        28
                                                                 8 November 20
                                                                             012

                          Checked by:

                                                               S
                                                               Sarah William
                                                                           ms
                                                           WiSE Laboratory
                                                                L          E
                                                                           Engineer

                          Issued by :


                                                      pp
                                                                John Newell
                                                        Group Quality Manag ger, WiSE
                                                               Basingstoke  e,
                                                               erification Se
                                                           UL Ve            ervices



                                                                  T
                                                                  This laboratoory is accred
                                                                                           dited by UKAS.
                                                                  T
                                                                  The tests repported hereinn have been
                                                                  performed inn accordance e with its’ term
                                                                                                          ms
                                                                  o
                                                                  of accreditattion.




RFI Globa
        al Services Ltd trading
                              g as UL
Pavilion A, A
            Ashwood Park, Ashwood Wayy, Basingstoke, Hampshire, RG23
                                                                R    8BG, UK
                                                                           K
Telephone: +444 (0)1256 3122000
Facsimile: +444 (0)1256 3120
                           001


TEST REPORT                                    SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                 ISSUE DATE: 28 NOVEMBER 2012



This page has been left intentionally blank.




Page 2 of 15                                      RFI Global Services Ltd trading as UL


TEST REPORT                                                                                    SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                                                  ISSUE DATE: 28 NOVEMBER 2012




Table of Contents
1. Customer Information .................................................................................................................. 4
2. Summary of Testing ..................................................................................................................... 5
    2.1. General Information                                                                                                                5
    2.2. Summary of Test Results                                                                                                            5
    2.3. Methods and Procedures                                                                                                             5
    2.4. Deviations from the Test Specification                                                                                             5
3. Equipment Under Test (EUT) ....................................................................................................... 6
    3.1. Identification of Equipment Under Test (EUT)                                                                                 6
    3.2. Description of EUT                                                                                                           6
    3.3. Modifications Incorporated in the EUT                                                                                        6
    3.4. Additional Information Related to Testing                                                                                    6
    3.5. Support Equipment                                                                                                            6
4. Operation and Monitoring of the EUT during Testing ............................................................... 7
    4.1. Operating Modes                                                                                              7
    4.2. Configuration and Peripherals                                                                                7
5. Measurements, Examinations and Derived Results .................................................................. 8
    5.1. General Comments                                                                                            8
    5.2. Test Results                                                                                                9
        5.2.1. Transmitter AC Conducted Spurious Emissions                                                           9
        5.2.2. Transmitter Radiated Spurious Emissions                                                            12
6. Measurement Uncertainty .......................................................................................................... 14
7. Report Revision History ............................................................................................................. 15




RFI Global Services Ltd trading as UL                                                                                         Page 3 of 15


TEST REPORT                                               SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                            ISSUE DATE: 28 NOVEMBER 2012




1. Customer Information
Company Name:     Panasonic Mobile Communications Development of Europe Ltd
Address:          Panasonic House
                  Willoughby Road
                  Bracknell
                  Berkshire
                  RG12 8FP
                  United Kingdom




Page 4 of 15                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                                    SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                                  ISSUE DATE: 28 NOVEMBER 2012




2. Summary of Testing
2.1. General Information
Specification Reference:            47CFR15.207 and 47CFR15.209
Specification Title:                Code of Federal Regulations Volume 47 (Telecommunications) 2012:
                                    Part 15 Subpart C (Intentional Radiators) - Sections 15.207 and 15.209
Site Registration:                  209735
Location of Testing:                RFI Global Services Ltd trading as UL, Wade Road, Basingstoke, Hampshire,
                                    RG24 8AH.
Test Dates:                         17 November 2012 to 21 November 2012

2.2. Summary of Test Results
FCC Reference (47CFR)               Measurement                                                              Result
Part 15.207                         Transmitter AC Conducted Emissions
Part 15.209                         Transmitter Radiated Emissions
Key to Results

    = Complied          = Did not comply


2.3. Methods and Procedures
Reference:                          ANSI C63.4 (2009)
Title:                              American National Standard for Methods of Measurement of Radio-Noise
                                    Emissions from Low-Voltage Electrical and Electronic Equipment in the Range
                                    of 9 kHz to 40 GHz

2.4. Deviations from the Test Specification
For the measurements contained within this test report, there were no deviations from, additions to, or
exclusions from the test specification identified above.




RFI Global Services Ltd trading as UL                                                                  Page 5 of 15


TEST REPORT                                                             SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                           ISSUE DATE: 28 NOVEMBER 2012




3. Equipment Under Test (EUT)
3.1. Identification of Equipment Under Test (EUT)
Brand Name:                                NTT docomo
Model Name or Number:                      Charger Pad Type Number: P02
Serial Number:                             No, 1
Hardware Version Number:                   Not marked or stated
Software Version Number:                   N/A


Brand Name:                                NTT docomo
Model Name or Number:                      Charger PSU Type Number: P02
Serial Number:                             No, 1
Hardware Version Number:                   Not marked or stated
Software Version Number:                   N/A

3.2. Description of EUT
The equipment under test was a Wireless Charger and associated PSU for a mobile phone.


3.3. Modifications Incorporated in the EUT
No modifications were applied to the EUT during testing.


3.4. Additional Information Related to Testing
 Tested Technology:                        Wireless Charger
 Mode                                      Charging
 Power Supply Requirement:                 Nominal                120 VAC 60 Hz
 Modulation Type:                          AM
 Transmit Frequency Range:                 125 kHz to 131 kHz

3.5. Support Equipment
The following support equipment was used to exercise the EUT during testing:

 Description:                             Multi-Mode LTE/UMTS/GSM Mobile Phone with WLAN, Bluetooth
                                          and RFID
 Brand Name:                              NTT docomo
 Model Name or Number:                    EB-4063
 IMEI:                                    353740050011927




Page 6 of 15                                                                   RFI Global Services Ltd trading as UL


TEST REPORT                                                                 SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                              ISSUE DATE: 28 NOVEMBER 2012




4. Operation and Monitoring of the EUT during Testing
4.1. Operating Modes
The EUT was tested in the following operating mode(s):
    •    Charging mode.
    •    Transmitting/charging in the 125 kHz to 131 kHz frequency range.


4.2. Configuration and Peripherals
The EUT was tested in the following configuration(s):
    •    Tests were performed with the mobile phone handset located in its’ normal position on the wireless
         charging pad.
    •    Connected to a 120 VAC 60 Hz single phase supply.
    •    AC conducted emissions tests were performed with the EUT connected to a 120 VAC 60 Hz single
         phase supply via a LISN.




RFI Global Services Ltd trading as UL                                                             Page 7 of 15


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                             ISSUE DATE: 28 NOVEMBER 2012




5. Measurements, Examinations and Derived Results
5.1. General Comments
Measurement uncertainties are evaluated in accordance with current best practice. Our reported expanded
uncertainties are based on standard uncertainties, which are multiplied by an appropriate coverage factor to
provide a statistical confidence level of approximately 95%. Please refer to Section 6 Measurement
Uncertainty for details.
In accordance with UKAS requirements all the measurement equipment is on a calibration schedule. All
equipment was within the calibration period on the date of testing.




Page 8 of 15                                                                  RFI Global Services Ltd trading as UL


TEST REPORT                                                                   SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                                ISSUE DATE: 28 NOVEMBER 2012




5.2. Test Results
5.2.1. Transmitter AC Conducted Spurious Emissions
Test Summary:

Test Engineer:                          Nick Steele                    Test Date:         21 November 2012
Test Sample Serial Number:              No, 1


FCC Reference:                          Part 15.207
Test Method Used:                       As detailed in ANSI C63.4 Section 7

Environmental Conditions:

Temperature (°C):                       19
Relative Humidity (%):                  46

Results: Live / Quasi Peak

  Frequency                  Line             Level           Limit              Margin           Result
    (MHz)                                    (dBμV)          (dBμV)               (dB)
      0.416                  Live             36.3            57.5                 21.2          Complied
      0.524                  Live             36.0            56.0                 20.0          Complied
      0.627                  Live             40.8            56.0                 15.2          Complied
      0.726                  Live             39.5            56.0                 16.5          Complied
      0.830                  Live             38.5            56.0                 17.5          Complied
      0.938                  Live             35.7            56.0                 20.3          Complied

Results: Live / Average

  Frequency                  Line             Level           Limit              Margin           Result
    (MHz)                                    (dBμV)          (dBμV)               (dB)
      0.416                  Live             21.4            47.5                 26.1          Complied
      0.830                  Live             22.1            46.0                 23.9          Complied
      4.038                  Live             17.2            46.0                 28.8          Complied
      4.871                  Live             17.4            46.0                 28.6          Complied
     13.691                  Live             20.7            50.0                 29.3          Complied
     15.135                  Live             20.3            50.0                 29.7          Complied




RFI Global Services Ltd trading as UL                                                              Page 9 of 15


TEST REPORT                                               SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                            ISSUE DATE: 28 NOVEMBER 2012




Transmitter AC Conducted Spurious Emissions (continued)
Results: Neutral / Quasi Peak

  Frequency         Line         Level         Limit         Margin                Result
    (MHz)                       (dBμV)        (dBμV)          (dB)
      0.524        Neutral       37.4           56.0           18.6               Complied
      0.627        Neutral       41.7           56.0           14.3               Complied
      0.740        Neutral       38.7           56.0           17.3               Complied
      0.830        Neutral       39.6           56.0           16.4               Complied
      0.933        Neutral       40.7           56.0           15.3               Complied
      1.037        Neutral       38.1           56.0           17.9               Complied

Results: Neutral / Average

  Frequency         Line         Level         Limit         Margin                Result
    (MHz)                       (dBμV)        (dBμV)          (dB)
      0.623        Neutral       27.2           46.0           18.8               Complied
      1.356        Neutral       17.6           46.0           28.4               Complied
      2.814        Neutral       19.2           46.0           26.8               Complied
      4.250        Neutral       21.3           46.0           24.7               Complied
      8.925        Neutral       21.2           50.0           28.8               Complied
     14.627        Neutral       23.9           50.0           26.1               Complied




Page 10 of 15                                                RFI Global Services Ltd trading as UL


TEST REPORT                                                                                                                                                                              SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                                                                                                                                               ISSUE DATE: 28 NOVEMBER 2012




Transmitter AC Conducted Spurious Emissions (continued)
                                           FCC Part 15 Class B Voltage with 2-Line-LISN Live                                                                                      FCC Part 15 Class B Voltage with 2-Line-LISN Neutral



                       80                                                                                                                                        80


                       75                                                                                                                                        75


                       70                                                                                                                                        70


                       65                                                                                                                                        65

                                                                                      FCC Part 15 Class B Voltage on Mains QP                                                                                                  FCC Part 15 Class B Voltage on Mains QP
                       60                                                                                                                                        60


                       55                                                                                                                                        55

                                                                                      FCC Part 15 Class B Voltage on Mains AV                                                                                                  FCC Part 15 Class B Voltage on Mains AV
                       50                                                                                                                                        50


                       45                                                                                                                                        45
       Level in dBµV




                                                                                                                                                 Level in dBµV
                       40                                                                                                                                        40


                       35                                                                                                                                        35


                       30                                                                                                                                        30


                       25                                                                                                                                        25


                       20                                                                                                                                        20


                       15                                                                                                                                        15


                       10                                                                                                                                        10


                        5                                                                                                                                         5


                        0                                                                                                                                         0
                        150k     300   400 500      800 1M              2M       3M     4M 5M 6        8 10M             20M    30M                               150k   300   400 500       800 1M              2M       3M     4M 5M 6        8 10M             20M    30M
                                                                  Frequency in Hz                                                                                                                         Frequency in Hz




                                                                 Live                                                                                                                                Neutral
Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables.

Test Equipment Used:

RFI No.                        Instrument                                    Manufacturer                                             Type No.            Serial No.                                       Date                                              Cal.
                                                                                                                                                                                                           Calibration                                       Interval
                                                                                                                                                                                                           Due                                               (Months)
 A649                          LISN                                          Rohde & Schwarz                                          ESH3-Z5              825562/008                                      19 Feb 2013                                                   12
A1830                          Pulse Limiter                                 Rohde & Schwarz                                          ESH3-Z2             100668                                           25 Feb 2013                                                   12
M1263                          Test Receiver                                 Rohde & Schwarz                                          ESIB7                100265                                          09 Aug 2013                                                   12




RFI Global Services Ltd trading as UL                                                                                                                                                                                                                          Page 11 of 15


TEST REPORT                                                                SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                             ISSUE DATE: 28 NOVEMBER 2012




5.2.2. Transmitter Radiated Spurious Emissions
Test Summary:

Test Engineer:                       Nick Steele                     Test Date:         17 November 2012
Test Sample Serial Number:           No, 1


FCC Reference:                       Part 15.209
Test Method Used:                    As detailed in ANSI C63.4 Section 8
Frequency Range:                     9 kHz to 1000 MHz

Environmental Conditions:

Temperature (°C):                    26
Relative Humidity (%):               34

Note(s):

1. Limits below 30 MHz are specified at a test distance of 30 metres, whilst below 0.49 MHz they are
   specified at a distance of 300 metres. However, as specified by FCC Section 15.31 (f)(2), measurements
   may be performed at a closer distance and the measured value corrected to the specified measurement
   distance by using the square of an inverse linear distance extrapolation factor (40 dB/decade).
2. A transducer factor on the measuring instrument was used to extrapolate the results at 3 metres to a
   distance of 30 metres where required. A distance extrapolation factor of 40 dB was used.
3. The emission shown at approximately 125 kHz is the charger frequency of the EUT. All other emissions
   on the 9 kHz to 150 kHz plot were investigated and found to be radiating from the test suite turntable.
4. The final measured value, for the given emission, in the table below incorporates the calibrated antenna
   factor and cable loss.
5. All other emissions shown on the pre-scan plot were investigated and found to be ambient or >20 dB
   below the applicable limit or below the measurement system noise floor.
6. Measurements in the range 30 MHz to 1 GHz were performed in a semi-anechoic chamber (RFI Asset
   Number K0001) at a distance of 3 metres. The EUT was placed at a height of 80 cm above the reference
   ground plane in the centre of the chamber turntable. Maximum emission levels were determined by
   height searching the measurement antenna over the range 1 metre to 4 metres.

Results: Quasi Peak

  Frequency          Antenna             Level              Limit             Margin                Result
    (MHz)            Polarity          (dBμV/m)           (dBμV/m)             (dB)
     75.012           Vertical            10.3               40.0               29.7               Complied
    124.504           Vertical               8.8             43.5               34.7               Complied




Page 12 of 15                                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                                                                                                                                                                                         SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                                                                                                                                                                                        ISSUE DATE: 28 NOVEMBER 2012




Transmitter Radiated Spurious Emissions (continued)
                                              Marker 1 [T1 CNT]                                    RBW                        300 Hz                           RF Att           10 dB                                        Marker 1 [T1]            RBW   10 kHz      RF Att      10 dB
           Ref Lvl                                            5.82 dBÌ V/m                         VBW                            1 kHz                                                                      Ref Lvl                 -2.37 dBÌ V/m    VBW   30 kHz
           70 dB*                                                          16 kHz                  SWT                                 8 s                     Unit             dBÌ V/m                       70 dB*             369.87099563 kHz     SWT   760 ms      Unit        dBÌ V/m
      70                                                                                                                                                                                                70
           10 kHz                                                                                                                                                 100 kHz                                                            1 MHz                     1 [T1]10 MHz-2.37 dBÌ V/m
                                                                                                                                                             A007FCC                      A                                                                                              A
                                                                                                                                                                                                                                                                       369.87099563 kHz
      60                                                                                                                                                                                                60 A007FCC
                                                                                                                                                                                                                                                               2 [T1]       -9.69 dBÌ V/m
                                                                                                                                                                                                                                                                        615.73216207 kHz
      50                                                                                                                                                                                                50



      40                                                                                                                                                                                  IN1           40                                                                                    IN1
           1VIEW                                                                                                                                                                          1MA                1MAX                                                                             1MA

      30                                                                                                                                                                                                30



      20                                                                                                                                                                                                20

                                                                                                                                                                                          TDF                                                                                                 TDF
      10                                                                                                                                                                                                10
                                          1


      0                                                                                                                                                                                                  0              1

                                                                                                                                                                                                                                2
   -10                                                                                                                                                                                                 -10



   -20                                                                                                                                                                                                 -20



   -30                                                                                                                                                                                                 -30
           Start 9 kHz                                                                                                                                               Stop 150 kHz                            Start 150 kHz                                                     Stop 30 MHz

  Title:     90385                                                                                                                                                                                    Title:     90385
  Comment A: TRANSMITTER RADIATED EMISSIONS                                                                                                                                                           Comment A: TRANSMITTER RADIATED EMISSIONS
  Date:      17.NOV.2012 06:13:39                                                                                                                                                                     Date:      17.NOV.2012 06:22:17



                                                FCC Part 15.209 Radiated Emissions Class B 30MHz-1GHz 3m




                               80




                               75




                               70




                               65




                               60




                               55                                                                          FCC Part 15 Class B Field Strength QP 3M




                               50




                               45
             Level in dBµV/m




                               40




                               35




                               30




                               25




                               20




                               15




                               10



                                5




                                0
                                30M       50M   60M        80M      100M                          200M                       300M                     400M    500M       800M      1G

                                                                                   Frequency in Hz




Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying table.

Test Equipment Used:

RFI                                   Instrument                                                                    Manufacturer                                                                Type No.               Serial No.                    Date                      Cal.
No.                                                                                                                                                                                                                                                  Calibration               Interval
                                                                                                                                                                                                                                                     Due                       (Months)
K0001                                 5m RSE Chamber                                                                Rainford                                                                    N/A                    N/A                           24 Oct 2013                      12
A007                                  Mag Loop Antenna                                                              Rohde & Schwarz                                                             HFH2-Z2                880 458/020                   20 Apr 2013                      12
M1273                                 Test Receiver                                                                 Rohde & Schwarz                                                             ESIB 26                1000275                       03 Feb 2013                      12
A1834                                 Attenuator                                                                    Hewlett Packard                                                             8491B                  10444                         29 Jan 2013                      12
A553                                  Antenna                                                                       Chase                                                                       CBL6111A               1593                          15 Feb 2013                      12
G0543                                 Amplifier                                                                     Sonoma                                                                      310N                   230801                        02 Jan 2013                       3




RFI Global Services Ltd trading as UL                                                                                                                                                                                                                                          Page 13 of 15


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                             ISSUE DATE: 28 NOVEMBER 2012




6. Measurement Uncertainty
No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the
results. Consequently the result of a measurement is only an approximation to the value of the measurand
(the specific quantity subject to measurement) and is only complete when accompanied by a statement of
the uncertainty of the approximation.
The expression of uncertainty of a measurement result allows realistic comparison of results with reference
values and limits given in specifications and standards.
The uncertainty of the result may need to be taken into account when interpreting the measurement results.
The reported expanded uncertainties below are based on a standard uncertainty multiplied by an appropriate
coverage factor such that a confidence level of approximately 95% is maintained. For the purposes of this
document “approximately” is interpreted as meaning “effectively” or “for most practical purposes”.

                                                                                 Confidence        Calculated
Measurement Type                                Range
                                                                                 Level (%)         Uncertainty
AC Conducted Spurious Emissions                 0.15 MHz to 30 MHz               95%               ±3.25 dB
Radiated Spurious Emissions                     0.009 MHz to 1000 MHz            95%               ±2.94 dB

The methods used to calculate the above uncertainties are in line with those recommended within the
various measurement specifications. Where measurement specifications do not include guidelines for the
evaluation of measurement uncertainty the published guidance of the appropriate accreditation body is
followed.




Page 14 of 15                                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                                SERIAL NO: UL-RPT-RP90385JD11A

VERSION NO. 2.0                                                              ISSUE DATE: 28 NOVEMBER 2012




7. Report Revision History
Version          Revision Details
Number           Page No(s)         Clause   Details
1.0              -                  -        Initial Version
2.0              -                  -        Update to transmit frequency range as requested by Customer




RFI Global Services Ltd trading as UL                                                            Page 15 of 15



Document Created: 2012-11-28 08:23:13
Document Modified: 2012-11-28 08:23:13

© 2024 FCC.report