RFID Test Report

FCC ID: UCE312057A

Test Report

Download: PDF
FCCID_1857220

                                      T T REP
                                      TEST  PORT
                                               T
                    Tes
                      st Repo
                            ort No. : UL-RP
                                          PT-RP90
                                                0385JD1
                                                      12A
        urer
Manufactu                     :   Pan
                                    nasonic Mo
                                             obile Communications Developme
                                                                  D         nt of Europe Ltd

Model No..                    :   NTT
                                    T docomo EB-4063
                                             E

FCC ID                        :   UC
                                   CE312057A

        gy
Technolog                     :   RFID – 13.56 MHz

         dard(s)
Test Stand                    :   FCC Parts 15.107(a), 15.109, 15.207
                                                                    7, 15.209(a) & 15.225




1.     Thiss test report shall
                         s     not be reproduced
                                      r            in full or partiial, without th
                                                                                 he written ap
                                                                                             pproval of
       RFI Global Services Ltd trading as UL.
2.     The results in this report appply only to the
                                                   e sample(s) tested.
                                                                   t
3.     Thiss sample testted is in commpliance with the above standard(s).
4.     The test results in this reportt are traceable to the natiional or interrnational stanndards.
5.     Verssion 1.0


                         Date of Issue:                       30 November 2012
                                                                          2

                         Checked by:



                                                                 Ian Watch
                                                            WiSE
                                                               E Senior Eng
                                                                          gineer

                         Issued by :


                                                     pp
                                                                John Newell
                                                        Group Quality Manag ger, WiSE
                                                               Basingstoke  e,
                                                           UL Ve
                                                               erification Se
                                                                            ervices



                                                                 T
                                                                 This laboratoory is accred
                                                                                          dited by UKAS.
                                                                 T
                                                                 The tests repported hereinn have been
                                                                 performed inn accordance e with its’ term
                                                                                                         ms
                                                                 o
                                                                 of accreditattion.




RFI Globa
        al Services Ltd trading
                              g as UL
Pavilion A, A
            Ashwood Park, Ashwood Wayy, Basingstoke, Hampshire, R
                                                                RG23 8BG, UK
                                                                           K
Telephone: +444 (0)1256 3122000
Facsimile: +444 (0)1256 3120
                           001


TEST REPORT                                    SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                     ISSUE DATE: 30 NOVEMBER 2012



This page has been left intentionally blank.




Page 2 of 30                                      RFI Global Services Ltd trading as UL


TEST REPORT                                                                                    SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                      ISSUE DATE: 30 NOVEMBER 2012




Table of Contents
1. Customer Information .................................................................................................................. 4
2. Summary of Testing ..................................................................................................................... 5
    2.1. General Information                                                                                                                5
    2.2. Summary of Test Results                                                                                                            5
    2.3. Methods and Procedures                                                                                                             6
    2.4. Deviations from the Test Specification                                                                                             6
3. Equipment Under Test (EUT) ....................................................................................................... 7
    3.1. Identification of Equipment Under Test (EUT)                                                                                 7
    3.2. Description of EUT                                                                                                           7
    3.3. Modifications Incorporated in the EUT                                                                                        7
    3.4. Additional Information Related to Testing                                                                                    8
    3.5. Support Equipment                                                                                                            8
4. Operation and Monitoring of the EUT during Testing ............................................................... 9
    4.1. Operating Modes                                                                                              9
    4.2. Configuration and Peripherals                                                                                9
5. Measurements, Examinations and Derived Results ................................................................ 10
    5.1. General Comments                                                                                          10
    5.2. Test Results                                                                                              11
        5.2.1. Receiver/Idle Mode AC Conducted Spurious Emissions                                                  11
        5.2.2. Receiver/Idle Mode Radiated Spurious Emissions                                                      14
        5.2.3. Transmitter AC Conducted Spurious Emissions                                                         17
        5.2.4. Transmitter Fundamental Field Strength                                                              20
        5.2.5. Transmitter Radiated Spurious Emissions                                                             22
        5.2.6. Transmitter Band Edge Radiated Emissions                                                            24
        5.2.7. Transmitter 20 dB Bandwidth                                                                         26
        5.2.8. Transmitter Frequency Stability (Temperature & Voltage Variation)                                   27
6. Measurement Uncertainty .......................................................................................................... 29
7. Report Revision History ............................................................................................................. 30




RFI Global Services Ltd trading as UL                                                                                         Page 3 of 30


TEST REPORT                                            SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                             ISSUE DATE: 30 NOVEMBER 2012




1. Customer Information
Company Name:    Panasonic Mobile Communications Development of Europe Ltd
Address:         Panasonic House
                 Willoughby Road
                 Bracknell
                 Berkshire
                 RG12 8FP
                 United Kingdom




Page 4 of 30                                               RFI Global Services Ltd trading as UL


TEST REPORT                                                                       SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                        ISSUE DATE: 30 NOVEMBER 2012




2. Summary of Testing
2.1. General Information

Specification Reference:                47CFR15.225
Specification Title:                    Code of Federal Regulations Volume 47 (Telecommunications) 2012:
                                        Part 15 Subpart C (Radio Frequency Devices) - Section 15.225
Specification Reference:                47CFR15.107 and 47CFR15.109
Specification Title:                    Code of Federal Regulations Volume 47 (Telecommunications) 2012:
                                        Part 15 Subpart B (Radio Frequency Devices) - Sections 15.107 and 15.109
Specification Reference:                47CFR15.207 and 47CFR15.209
Specification Title:                    Code of Federal Regulations Volume 47 (Telecommunications) 2012:
                                        Part 15 Subpart C (Intentional Radiators) - Sections 15.207 and 15.209
Site Registration:                      209735
Location of Testing:                    RFI Global Services Ltd trading as UL, Wade Road, Basingstoke,
                                        Hampshire, RG24 8AH.
Test Dates:                             11 November 2012 to 28 November 2012

2.2. Summary of Test Results

FCC Reference (47CFR)                   Measurement                                                           Result
Part 15.107(a)                          Receiver/Idle Mode AC Conducted Spurious Emissions
Part 15.109                             Receiver/Idle Mode Radiated Spurious Emissions
Part 15.207                             Transmitter AC Conducted Emissions
Part 15.225(a)(b)(c)(d)                 Transmitter Fundamental Field Strength
Part 15.209(a), 15.225(d)               Transmitter Radiated Spurious Emissions
Part 15.209(a), 15.225(c)(d)            Transmitter Band Edge Radiated Emissions
Part 2.1049                             Transmitter 20 dB Bandwidth
Part 15.225(e)                          Transmitter Frequency Stability (Temperature & Voltage Variation)
Key to Results

   = Complied           = Did not comply




RFI Global Services Ltd trading as UL                                                                       Page 5 of 30


TEST REPORT                                                                SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                  ISSUE DATE: 30 NOVEMBER 2012




2.3. Methods and Procedures

Reference:                    ANSI C63.4 (2009)
Title:                        American National Standard for Methods of Measurement of Radio-Noise
                              Emissions from Low-Voltage Electrical and Electronic Equipment in the Range
                              of 9 kHz to 40 GHz
Reference:                    ANSI C63.10 (2009)
Title:                        American National Standard for Testing Unlicensed Wireless Devices

2.4. Deviations from the Test Specification

For the measurements contained within this test report, there were no deviations from, additions to, or
exclusions from the test specification identified above.




Page 6 of 30                                                                   RFI Global Services Ltd trading as UL


TEST REPORT                                                         SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                          ISSUE DATE: 30 NOVEMBER 2012




3. Equipment Under Test (EUT)
3.1. Identification of Equipment Under Test (EUT)

Brand Name:                                NTT docomo
Model Name or Number:                      EB-4063
IMEI:                                      353740050011927
Hardware Version Number:                   Rev B-2
Software Version Number:                   ACPU: rupy-jb-10-0336
                                           CCPU: 101033_DCM_00.12
FCC ID:                                    UCE312057A


Brand Name:                                NTT docomo
Description:                               Battery
Model Name or Number:                      P29


Brand Name:                                NTT docomo
Description:                               AC Charger
Model Name or Number:                      AC 04


Brand Name:                                NTT docomo
Description:                               Charge/USB Data cable
Model Name or Number:                      Type 01


Brand Name:                                NTT docomo
Description:                               Personal Hands-Free
Model Name or Number:                      Type 02

3.2. Description of EUT

The equipment under test was a Multi-Mode LTE/UMTS/GSM Mobile Phone with WLAN, Bluetooth and
RFID.


3.3. Modifications Incorporated in the EUT

No modifications were applied to the EUT during testing.




RFI Global Services Ltd trading as UL                                                    Page 7 of 30


TEST REPORT                                                             SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                               ISSUE DATE: 30 NOVEMBER 2012



3.4. Additional Information Related to Testing

Tested Technology:                       RFID
Category of Equipment:                   Transceiver
Channel Spacing:                         Single channel device
Transmit Frequency Range:                13.56 MHz
Receive Frequency Range:                 13.56 MHz
Power Supply Requirement:                Nominal        3.8 V
                                         Minimum        3.4 V
                                         Maximum        4.35 V
Tested Temperature Range:                Minimum        -20°C
                                         Maximum         50°C


3.5. Support Equipment
The following support equipment was used to exercise the EUT during testing:

Brand Name:                               Not stated
Description:                              2 GB Micro SD Card
Model Name or Number:                     Not stated


Brand Name:                               Not stated
Description:                              Dummy Battery
Model Name or Number:                     Not stated


Brand Name:                               Hewlett Packard
Description:                              Laptop PC
Model Name or Number:                     HP Mini 200-4200
Serial Number:                            5CD2251C1Y




Page 8 of 30                                                                   RFI Global Services Ltd trading as UL


TEST REPORT                                                                 SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                  ISSUE DATE: 30 NOVEMBER 2012




4. Operation and Monitoring of the EUT during Testing
4.1. Operating Modes

The EUT was tested in the following operating mode(s):
    •    Receiver/Idle mode.
    •    Constantly transmitting at full power with a modulated carrier in RFID test mode.


4.2. Configuration and Peripherals

The EUT was tested in the following configuration(s):
    •    The RFID transmitter test mode was enabled by means of bespoke software provided by the
         Customer.
    •    Receiver idle/standby mode radiated spurious emission tests were performed with the AC Charger
         and PHF connected to the EUT as this was found to be the worst case during pre-scans. All
         accessories were individually connected and measurements made during pre-scans to determine
         the worst case combination.
    •    Transmitter radiated spurious emission tests were performed with the AC Charger and PHF
         connected to the EUT as this was found to be the worst case during pre-scans. All appropriate
         accessories were individually connected and measurements made during pre-scans to determine
         the worst case combination.
    •    Testing at voltage extremes was performed using a dummy battery supplied by the Customer.
    •    AC conducted emissions tests were performed with the EUT connected to the AC charger. The AC
         charger was connected to a 120 VAC 60 Hz single phase supply via a LISN.




RFI Global Services Ltd trading as UL                                                            Page 9 of 30


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                 ISSUE DATE: 30 NOVEMBER 2012




5. Measurements, Examinations and Derived Results
5.1. General Comments
Measurement uncertainties are evaluated in accordance with current best practice. Our reported expanded
uncertainties are based on standard uncertainties, which are multiplied by an appropriate coverage factor to
provide a statistical confidence level of approximately 95%. Please refer to Section 6: Measurement
Uncertainties for details.
In accordance with UKAS requirements all the measurement equipment is on a calibration schedule. All
equipment was within the calibration period on the date of testing.




Page 10 of 30                                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                 ISSUE DATE: 30 NOVEMBER 2012




5.2. Test Results
5.2.1. Receiver/Idle Mode AC Conducted Spurious Emissions
Test Summary:

Test Engineer:                          David Doyle                    Test Date:      15 November 2012
Test Sample IMEI:                       353740050011927


FCC Reference:                          Part 15.107(a)
Test Method Used:                       As detailed in ANSI C63.10 Section 6.2 referencing ANSI C63.4

Environmental Conditions:

Temperature (°C):                       21
Relative Humidity (%):                  41

Results: Live / Quasi Peak

  Frequency                  Line             Level           Limit           Margin            Result
    (MHz)                                    (dBμV)          (dBμV)            (dB)
      0.479                  Live             42.3            56.4              14.1           Complied
      2.558                  Live             34.6            56.0              21.4           Complied
      4.259                  Live             36.0            56.0              20.0           Complied
      4.493                  Live             37.9            56.0              18.1           Complied
      5.325                  Live             36.5            60.0              23.5           Complied
      5.694                  Live             36.2            60.0              23.8           Complied

Results: Live / Average

  Frequency                  Line             Level           Limit           Margin            Result
    (MHz)                                    (dBμV)          (dBμV)            (dB)
      0.474                  Live             35.9            46.4              10.5           Complied
      2.832                  Live             33.4            46.0              12.6           Complied
      4.335                  Live             28.8            46.0              17.2           Complied
      4.515                  Live             30.6            46.0              15.4           Complied
      5.357                  Live             29.4            50.0              20.6           Complied
      5.681                  Live             29.9            50.0              20.1           Complied




RFI Global Services Ltd trading as UL                                                            Page 11 of 30


TEST REPORT                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                ISSUE DATE: 30 NOVEMBER 2012




Receiver/Idle Mode AC Conducted Spurious Emissions (continued)
Results: Neutral / Quasi Peak

  Frequency         Line         Level         Limit         Margin                Result
    (MHz)                       (dBμV)        (dBμV)          (dB)
      0.209        Neutral       34.6           63.3             28.7             Complied
      2.004        Neutral       22.1           56.0             33.9             Complied
      2.526        Neutral       23.7           56.0             32.3             Complied
      3.539        Neutral       28.8           56.0             27.2             Complied
      4.812        Neutral       36.7           56.0             19.3             Complied
      5.240        Neutral       36.4           60.0             23.6             Complied
      5.645        Neutral       36.2           60.0             23.8             Complied

Results: Neutral / Average

  Frequency         Line         Level         Limit         Margin                Result
    (MHz)                       (dBμV)        (dBμV)          (dB)
      0.213        Neutral       23.4           53.1             29.7             Complied
      1.950        Neutral       13.6           46.0             32.4             Complied
      2.949        Neutral       15.6           46.0             30.4             Complied
      4.205        Neutral       22.6           46.0             23.4             Complied
      4.920        Neutral       26.9           46.0             19.1             Complied
      5.177        Neutral       27.7           50.0             22.3             Complied
      5.573        Neutral       28.3           50.0             21.7             Complied




Page 12 of 30                                                RFI Global Services Ltd trading as UL


TEST REPORT                                                                                                                                                                                       SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                                                                                                            ISSUE DATE: 30 NOVEMBER 2012




Receiver/Idle Mode AC Conducted Spurious Emissions (continued)
                                           FCC Part 15 Class B Voltage with 2-Line-LISN Live                                                                                               FCC Part 15 Class B Voltage with 2-Line-LISN Neutral




                       80                                                                                                                                              80


                       75                                                                                                                                              75


                       70                                                                                                                                              70


                       65                                                                                                                                              65

                                                                                      FCC Part 15 Class B Voltage on Mains QP                                                                                                           FCC Part 15 Class B Voltage on Mains QP
                       60                                                                                                                                              60


                       55                                                                                                                                              55

                                                                                      FCC Part 15 Class B Voltage on Mains AV                                                                                                           FCC Part 15 Class B Voltage on Mains AV
                       50                                                                                                                                              50


                       45                                                                                                                                              45
       Level in dBµV




                                                                                                                                                       Level in dBµV
                       40                                                                                                                                              40


                       35                                                                                                                                              35


                       30                                                                                                                                              30


                       25                                                                                                                                              25


                       20                                                                                                                                              20


                       15                                                                                                                                              15


                       10                                                                                                                                              10


                        5                                                                                                                                               5


                        0                                                                                                                                               0
                        150k     300   400 500      800 1M              2M       3M      4M 5M 6              8 10M             20M   30M                               150k      300   400 500       800 1M              2M       3M      4M 5M 6              8 10M              20M   30M
                                                                  Frequency in Hz                                                                                                                                   Frequency in Hz




                                                                 Live                                                                                                                                        Neutral
Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables.

Test Equipment Used:

RFI No.                        Instrument                                        Manufacturer                                               Type No.                           Serial No.                           Date                                                          Cal.
                                                                                                                                                                                                                    Calibration                                                   Interval
                                                                                                                                                                                                                    Due                                                           (Months)
 A649                          LISN                                              Rohde & Schwarz                                            ESH3-Z5                            825562/008                           19 Feb 2013                                                          12
A1830                          Pulse Limiter                                     Rohde & Schwarz                                            ESH3-Z2                            100668                               25 Feb 2013                                                          12
M1263                          Test Receiver                                     Rohde & Schwarz                                            ESIB7                              100265                               09 Aug 2013                                                          12




RFI Global Services Ltd trading as UL                                                                                                                                                                                                                                             Page 13 of 30


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                 ISSUE DATE: 30 NOVEMBER 2012




5.2.2. Receiver/Idle Mode Radiated Spurious Emissions
Test Summary:

Test Engineer:                        Nick Steele                     Test Dates:       11 November 2012 &
                                                                                        17 November 2012
Test Sample IMEI:                     353740050011927


FCC Reference:                        Part 15.109
Test Method Used:                     As detailed in ANSI C63.10 Sections 6.3, 6.4 and 6.5
                                      referencing ANSI C63.4
Frequency Range:                      9 kHz to 1000 MHz

Environmental Conditions:

Temperature (°C):                     23 to 26
Relative Humidity (%):                33 to 34

Note(s):

1. Limits below 30 MHz are specified at a test distance of 30 metres, whilst below 0.49 MHz they are
   specified at a test distance of 300 metres. However, as specified by FCC Section 15.31 (f)(2),
   measurements may be performed at a closer distance and the measured level corrected to the specified
   measurement distance by using the square of an inverse linear distance extrapolation factor
   (40dB/decade).
2. A transducer factor on the measuring instrument was used to extrapolate the results at 3 metres to a
   distance of 30 metres where required. A distance extrapolation factor of 40 dB was used.
3. Final measurement values include corrections for antenna factor and cable losses.
4. All emissions on the 9 kHz to 150 kHz plot were investigated and found to be radiating from the test site
   turntable.
5. All other emissions shown on the pre-scan plots were investigated and found to be >20 dB below the
   applicable limit or below the measurement system noise floor.
6. Measurements in the range 30 MHz to 1 GHz were performed in a semi-anechoic chamber (RFI Asset
   Number K0001) at a distance of 3 metres. The EUT was placed at a height of 80 cm above the reference
   ground plane in the centre of the chamber turntable. Maximum emission levels were determined by
   height searching the measurement antenna over the range 1 metre to 4 metres

Results: Quasi Peak

  Frequency           Antenna             Level              Limit            Margin                Result
    (MHz)             Polarity          (dBμV/m)           (dBμV/m)            (dB)
     30.986           Vertical             20.2              40.0               19.8               Complied
     36.115           Vertical             14.8              40.0               25.2               Complied
     50.848           Vertical             10.9              40.0               29.1               Complied
    127.430           Vertical             11.1              43.5               32.4               Complied
    142.693           Vertical             9.9               43.5               33.6               Complied
    956.932           Vertical             24.6              46.0               21.4               Complied




Page 14 of 30                                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                                                                                                                                                                             SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                                                                                                                                  ISSUE DATE: 30 NOVEMBER 2012




Receiver/Idle Mode Radiated Spurious Emissions (continued)
                                        Marker 1 [T1]                                        RBW                         300 Hz                          RF Att           10 dB                                  Marker 1 [T1]           RBW   10 kHz      RF Att      10 dB
         Ref Lvl                                         5.16 dBÌ V/m                        VBW                             1 kHz                                                               Ref Lvl                -10.18 dBÌ V/m   VBW   30 kHz
         70 dB*                                 15.72727148 kHz                              SWT                                  8 s                    Unit             dBÌ V/m                 70 dB*             187.46845177 kHz    SWT   760 ms      Unit        dBÌ V/m
    70                                                                                                                                                                                      70
         10 kHz                                                                                                                               1005.16
                                                                                                                                                  kHz dB V/m                                                             1 MHz                    1 [T1]10 MHz
                                                                                                                                    1 [T1]              Ì    A
                                                                                                                                                                                                                                                             -10.18 dBÌ V/m
                                                                                                                                                                                                                                                                            A
                                                                                                                                         A007FCC
                                                                                                                                            15.72727148 kHz                                                                                               187.46845177 kHz
    60                                                                                                                                                                                      60 A007FCC
                                                                                                                                                                                                                                                  2 [T1]      -20.33 dBÌ V/m
                                                                                                                                                                                                                                                           892.86691082 kHz
    50                                                                                                                                                                                      50



    40                                                                                                                                                                              IN1     40                                                                                   IN1
         1MAX                                                                                                                                                                       1MA          1MAX                                                                            1MA

    30                                                                                                                                                                                      30



    20                                                                                                                                                                                      20

                                                                                                                                                                                    TDF                                                                                          TDF
    10                                                                                                                                                                                      10
                                    1


     0                                                                                                                                                                                       0


                                                                                                                                                                                                   1
   -10                                                                                                                                                                                     -10


                                                                                                                                                                                                                         2
   -20                                                                                                                                                                                     -20



   -30                                                                                                                                                                                     -30
         Start 9 kHz                                                                                                                                           Stop 150 kHz                      Start 150 kHz                                                    Stop 30 MHz

  Title:     90385                                                                                                                                                                        Title:     90385
  Comment A: RECEIVER RADIATED EMISSIONS                                                                                                                                                  Comment A: RECEIVER RADIATED EMISSIONS
  Date:      17.NOV.2012 10:24:14                                                                                                                                                         Date:      17.NOV.2012 10:32:50




                                           FCC Part 15.109 Radiated Emissions Class B 30MHz-1GHz 3m




                             80




                             75




                             70




                             65




                             60




                             55                                                                       FCC Part 15 Class B Field Strength QP 3M




                             50




                             45
           Level in dBµV/m




                             40




                             35




                             30




                             25




                             20




                             15




                             10



                              5




                              0
                              30M   50M   60M         80M      100M                         200M                        300M                     400M   500M       800M      1G

                                                                              Frequency in Hz




Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying
table.




RFI Global Services Ltd trading as UL                                                                                                                                                                                                                             Page 15 of 30


TEST REPORT                                                       SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                        ISSUE DATE: 30 NOVEMBER 2012




Receiver/Idle Mode Radiated Spurious Emissions (continued)
Test Equipment Used:

RFI       Instrument         Manufacturer      Type No.   Serial No.       Date               Cal.
No.                                                                        Calibration        Interval
                                                                           Due                (Months)
A1834     Attenuator         Hewlett Packard   8491B      10444            29 Jan 2013             12
A553      Antenna            Chase             CBL6111A   1593             15 Feb 2013             12
G0543     Amplifier          Sonoma            310N       230801           02 Jan 2013              3
K0001     5m RSE Chamber     Rainford EMC      N/A        N/A              24 Oct 2013             12
M1273     Test Receiver      Rohde & Schwarz   ESIB 26    100275           03 Feb 2013             12
A007      Mag Loop Antenna   Rohde & Schwarz   HFH2-Z2    880 458/020      20 Apr 2013             12




Page 16 of 30                                                          RFI Global Services Ltd trading as UL


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                 ISSUE DATE: 30 NOVEMBER 2012




5.2.3. Transmitter AC Conducted Spurious Emissions
Test Summary:

Test Engineer:                          Nick Steele                   Test Date:       21 November 2012
Test Sample IMEI:                       353740050011927


FCC Reference:                          Part 15.207
Test Method Used:                       As detailed in ANSI C63.10 Section 6.2 referencing ANSI C63.4

Environmental Conditions:

Temperature (°C):                       19
Relative Humidity (%):                  46

Results: Live / Quasi Peak

  Frequency                  Line             Level           Limit           Margin            Result
    (MHz)                                    (dBμV)          (dBμV)            (dB)
      0.150                  Live             58.2            66.0              7.8            Complied
      0.213                  Live             54.6            63.1              8.5            Complied
      0.227                  Live             53.9            62.6              8.7            Complied
      0.245                  Live             53.3            61.9              8.6            Complied
      0.254                  Live             52.7            61.6              8.9            Complied
      0.267                  Live             52.2            61.2              9.0            Complied
      0.290                  Live             50.9            60.5              9.6            Complied
      0.303                  Live             50.6            60.2              9.6            Complied
      0.330                  Live             49.4            59.5              10.1           Complied
      0.425                  Live             46.8            57.4              10.6           Complied
     13.560                  Live             48.5            60.0              11.5           Complied

Results: Live / Average

  Frequency                  Line             Level           Limit           Margin            Result
    (MHz)                                    (dBμV)          (dBμV)            (dB)
      0.204                  Live             30.6            53.4              22.8           Complied
      0.254                  Live             28.9            51.6              22.7           Complied
      0.308                  Live             28.6            50.0              21.4           Complied
      0.465                  Live             28.4            46.6              18.2           Complied
      4.578                  Live             28.2            46.0              17.8           Complied
     13.560                  Live             47.1            50.0              2.9            Complied




RFI Global Services Ltd trading as UL                                                           Page 17 of 30


TEST REPORT                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                ISSUE DATE: 30 NOVEMBER 2012



Transmitter AC Conducted Spurious Emissions (continued)
Results: Neutral / Quasi Peak

  Frequency         Line         Level         Limit         Margin                Result
    (MHz)                       (dBμV)        (dBμV)          (dB)
      0.159        Neutral       55.5           65.5           10.0               Complied
      0.245        Neutral       51.5           61.9           10.4               Complied
      0.416        Neutral       45.1           57.5           12.4               Complied
      0.731        Neutral       38.5           56.0           17.5               Complied
      1.275        Neutral       33.6           56.0           22.4               Complied
      4.673        Neutral       33.4           56.0           22.6               Complied
      4.920        Neutral       34.7           56.0           21.3               Complied
     13.560        Neutral       48.9           60.0           11.1               Complied

Results: Neutral / Average

  Frequency         Line         Level         Limit         Margin                Result
    (MHz)                       (dBμV)        (dBμV)          (dB)
      0.204        Neutral       31.6           53.4           21.8               Complied
      0.209        Neutral       31.1           53.3           22.2               Complied
      0.470        Neutral       23.2           46.5           23.3               Complied
      4.821        Neutral       24.4           46.0           21.6               Complied
      5.361        Neutral       24.9           50.0           25.1               Complied
     13.560        Neutral       46.5           50.0           3.5                Complied




Page 18 of 30                                                RFI Global Services Ltd trading as UL


TEST REPORT                                                                                                                                                                              SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                                                                                                   ISSUE DATE: 30 NOVEMBER 2012




Transmitter AC Conducted Spurious Emissions (continued)
                                           FCC Part 15 Class B Voltage with 2-Line-LISN Live                                                                                      FCC Part 15 Class B Voltage with 2-Line-LISN Neutral



                       80                                                                                                                                        80


                       75                                                                                                                                        75


                       70                                                                                                                                        70


                       65                                                                                                                                        65

                                                                                      FCC Part 15 Class B Voltage on Mains QP                                                                                                  FCC Part 15 Class B Voltage on Mains QP
                       60                                                                                                                                        60


                       55                                                                                                                                        55

                                                                                      FCC Part 15 Class B Voltage on Mains AV                                                                                                  FCC Part 15 Class B Voltage on Mains AV
                       50                                                                                                                                        50


                       45                                                                                                                                        45
       Level in dBµV




                                                                                                                                                 Level in dBµV
                       40                                                                                                                                        40


                       35                                                                                                                                        35


                       30                                                                                                                                        30


                       25                                                                                                                                        25


                       20                                                                                                                                        20


                       15                                                                                                                                        15


                       10                                                                                                                                        10


                        5                                                                                                                                         5


                        0                                                                                                                                         0
                        150k     300   400 500      800 1M              2M       3M     4M 5M 6         8 10M            20M    30M                               150k   300   400 500       800 1M              2M       3M     4M 5M 6         8 10M            20M    30M
                                                                  Frequency in Hz                                                                                                                         Frequency in Hz




                                                                 Live                                                                                                                                Neutral

Note: These plots are pre-scans and for indication purposes only. For final measurements, see
accompanying tables.
Test Equipment Used:

RFI No.                        Instrument                                 Manufacturer                                                Type No.                   Serial No.                                Date                                              Cal.
                                                                                                                                                                                                           Calibration                                       Interval
                                                                                                                                                                                                           Due                                               (Months)
 A649                          LISN                                       Rohde & Schwarz                                             ESH3-Z5                    825562/008                                19 Feb 2013                                                   12
A1830                          Pulse Limiter                              Rohde & Schwarz                                             ESH3-Z2                    100668                                    25 Feb 2013                                                   12
M1263                          Test Receiver                              Rohde & Schwarz                                             ESIB7                      100265                                    09 Aug 2013                                                   12




RFI Global Services Ltd trading as UL                                                                                                                                                                                                                          Page 19 of 30


TEST REPORT                                                                                                     SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                           ISSUE DATE: 30 NOVEMBER 2012




5.2.4. Transmitter Fundamental Field Strength
Test Summary:

Test Engineer:                                  Nick Steele                                                 Test Date:                  17 November 2012
Test Sample IMEI:                               353740050011927


FCC Reference:                                  Part 15.225(a)(b)(c)(d)
Test Method Used:                               ANSI C63.10 Section 6.4

Environmental Conditions:

Temperature (°C):                               26
Relative Humidity (%):                          34

Note(s):

1. The limit is specified at a test distance of 30 metres. However, as specified by FCC Section 15.31 (f)(2),
   measurements may be performed at a closer distance and the measured level corrected to the specified
   measurement distance by using the square of an inverse linear distance extrapolation factor
   (40dB/decade).
2. A transducer factor on the measuring instrument was used to extrapolate the results at 3 metres to a
   distance of 30 metres. A distance extrapolation factor of 40 dB was used.
3. Pre-scans were performed with a peak detector. Final measurements were performed with a quasi-peak
   detector.

Results: Quasi Peak

  Frequency           Antenna                       Level                         Limit at 30 m                               Margin                Result
    (MHz)             Polarity                    (dBμV/m)                          (dBμV/m)                                   (dB)
      13.56          90° to EUT                         -2.9                             84.0                                  86.9                Complied

                                                     Marker 1 [T1]                RBW   10 kHz     RF Att     10 dB
                                      Ref Lvl                 -2.90 dBÌ V/m       VBW   30 kHz
                                      60 dB*               13.56300601 MHz        SWT   25 ms      Unit       dBÌ V/m
                                 60
                                                                                          1 [T1]      -2.90 dBÌ V/m
                                                                                                                    A
                                                                                                   13.56300601 MHz
                                 50



                                 40



                                 30 15225BE                                                                             IN1
                                    1MAX                                                                                1MA

                                 20



                                 10

                                                                                                                        TDF
                                 0                                            1



                               -10



                               -20



                               -30
                                                                                                               F2
                                        F1
                               -40
                                      Start 13.06 MHz                  100 kHz/                     Stop 14.06 MHz

                              Title:         90385
                              Date:          17.NOV.2012   09:16:31




Page 20 of 30                                                                                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                                    SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                       ISSUE DATE: 30 NOVEMBER 2012



Transmitter Fundamental Field Strength (continued)
Test Equipment Used:

RFI        Instrument                   Manufacturer      Type No.   Serial No.       Date          Cal.
No.                                                                                   Calibration   Interval
                                                                                      Due           (Months)
K0001      5m RSE Chamber               Rainford          N/A        N/A              24 Oct 2013       12
A007       Mag Loop Antenna             Rohde & Schwarz   HFH2-Z2    880 458/020      20 Apr 2013       12
M1273      Test Receiver                Rohde & Schwarz   ESIB 26    1000275          03 Feb 2013       12




RFI Global Services Ltd trading as UL                                                               Page 21 of 30


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                 ISSUE DATE: 30 NOVEMBER 2012




5.2.5. Transmitter Radiated Spurious Emissions
Test Summary:

Test Engineer:                        Nick Steele                     Test Date:        17 November 2012
Test Sample IMEI:                     353740050011927


FCC Reference:                        Parts 15.225(d) & 15.209(a)
Test Method Used:                     As detailed in ANSI C63.10 Sections 6.3, 6.4 and 6.5 referencing
                                      ANSI C63.4
Frequency Range:                      9 kHz to 1000 MHz

Environmental Conditions:

Temperature (°C):                     26
Relative Humidity (%):                34

Note(s):
1. Limits below 30 MHz are specified at a test distance of 30 metres, whilst below 0.49 MHz they are
   specified at a test distance of 300 metres. However, as specified by FCC Section 15.31 (f)(2),
   measurements may be performed at a closer distance and the measured level corrected to the specified
   measurement distance by using the square of an inverse linear distance extrapolation factor
   (40dB/decade).
2. A transducer factor on the measuring instrument was used to extrapolate the results at 3 metres to a
   distance of 30 metres where required. A distance extrapolation factor of 40 dB was used.
3. Final measurement values include corrections for antenna factor and cable losses.
4. The emission shown at approximately 13.56 MHz is the fundamental.
5. All emissions on the 9 kHz to 150 kHz plot were investigated and found to be radiating from the test site
   turntable.
6. All other emissions shown on the pre-scan plots were investigated and found to be >20 dB below the
   applicable limit or below the measurement system noise floor.
7. Measurements in the range 30 MHz to 1 GHz were performed in a semi-anechoic chamber (RFI Asset
   Number K0001) at a distance of 3 metres. The EUT was placed at a height of 80 cm above the reference
   ground plane in the centre of the chamber turntable. Maximum emission levels were determined by
   height searching the measurement antenna over the range 1 metre to 4 metres.

Results: Quasi Peak

  Frequency           Antenna             Level              Limit            Margin                Result
    (MHz)             Polarity          (dBμV/m)           (dBμV/m)            (dB)
    244.092           Vertical             14.5              46.0               31.5               Complied
    257.622           Vertical             17.7              46.0               28.3               Complied
    271.210           Vertical             14.2              46.0               31.8               Complied
    284.741           Vertical             16.4              46.0               29.6               Complied




Page 22 of 30                                                                 RFI Global Services Ltd trading as UL


TEST REPORT                                                                                                                                                                                                                         SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                                                                                                                                              ISSUE DATE: 30 NOVEMBER 2012




Transmitter Radiated Spurious Emissions (continued)
                                              Marker 1 [T1 CNT]                                    RBW                        300 Hz                           RF Att           10 dB                                        Marker 1 [T1]               RBW   10 kHz      RF Att      10 dB
           Ref Lvl                                            5.75 dBÌ V/m                         VBW                            1 kHz                                                                      Ref Lvl                 -9.34 dBÌ V/m       VBW   30 kHz
           70 dB*                                                          16 kHz                  SWT                                 8 s                     Unit             dBÌ V/m                       70 dB*             159.86704754 kHz        SWT   760 ms      Unit        dBÌ V/m
      70                                                                                                                                                                                                70
           10 kHz                                                                                                                                                 100 kHz                                                            1 MHz                        1 [T1]10 MHz-9.34 dBÌ V/m
                                                                                                                                                             A007FCC                      A                                                                                                 A
                                                                                                                                                                                                                                                                          159.86704754 kHz
      60                                                                                                                                                                                                60 A007FCC
                                                                                                                                                                                                                                                                  2 [T1]      -16.74 dBÌ V/m
                                                                                                                                                                                                                                                                           892.86691082 kHz
      50                                                                                                                                                                                                50



      40                                                                                                                                                                                  IN1           40                                                                                       IN1
           1VIEW                                                                                                                                                                          1MA                1MAX                                                                                1MA

      30                                                                                                                                                                                                30



      20                                                                                                                                                                                                20

                                                                                                                                                                                          TDF                                                                                                    TDF
      10                                                                                                                                                                                                10
                                          1


      0                                                                                                                                                                                                  0


                                                                                                                                                                                                             1
   -10                                                                                                                                                                                                 -10
                                                                                                                                                                                                                                     2

   -20                                                                                                                                                                                                 -20



   -30                                                                                                                                                                                                 -30
           Start 9 kHz                                                                                                                                               Stop 150 kHz                            Start 150 kHz                                                        Stop 30 MHz

  Title:     90385                                                                                                                                                                                    Title:     90385
  Comment A: TRANSMITTER RADIATED EMISSIONS                                                                                                                                                           Comment A: TRANSMITTER RADIATED EMISSIONS
  Date:      17.NOV.2012 09:10:40                                                                                                                                                                     Date:      17.NOV.2012 09:03:56




                                                FCC Part 15.209 Radiated Emissions Class B 30MHz-1GHz 3m




                               80
                                                                                                                                                                                                                                                     .
                               75




                               70




                               65




                               60




                               55                                                                          FCC Part 15 Class B Field Strength QP 3M




                               50




                               45
             Level in dBµV/m




                               40




                               35




                               30




                               25




                               20




                               15




                               10



                                5




                                0
                                30M       50M   60M        80M      100M                          200M                       300M                     400M    500M       800M      1G

                                                                                   Frequency in Hz




Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying
table.
Test Equipment Used:

RFI                                   Instrument                                                                    Manufacturer                                                                Type No.               Serial No.                    Date                         Cal.
No.                                                                                                                                                                                                                                                  Calibration                  Interval
                                                                                                                                                                                                                                                     Due                          (Months)
K0001                                 5m RSE Chamber                                                                Rainford                                                                    N/A                    N/A                           24 Oct 2013                         12
A007                                  Mag Loop Antenna                                                              Rohde & Schwarz                                                             HFH2-Z2                880 458/020                   20 Apr 2013                         12
M1273                                 Test Receiver                                                                 Rohde & Schwarz                                                             ESIB 26                1000275                       03 Feb 2013                         12
A1834                                 Attenuator                                                                    Hewlett Packard                                                             8491B                  10444                         29 Jan 2013                         12
A553                                  Antenna                                                                       Chase                                                                       CBL6111A               1593                          15 Feb 2013                         12
G0543                                 Amplifier                                                                     Sonoma                                                                      310N                   230801                        02 Jan 2013                          3




RFI Global Services Ltd trading as UL                                                                                                                                                                                                                                             Page 23 of 30


TEST REPORT                                                                                            SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                  ISSUE DATE: 30 NOVEMBER 2012




5.2.6. Transmitter Band Edge Radiated Emissions
Test Summary:

Test Engineer:                               Nick Steele                                           Test Date:                  17 November 2012
Test Sample IMEI:                            353740050011927


FCC Reference:                               Parts 15.225(c)(d) & 15.209(a)
Test Method Used:                            As detailed in ANSI C63.10 Section 6.9.2

Environmental Conditions:

Temperature (°C):                            26
Relative Humidity (%):                       34

Note(s):
1. A transducer factor on the measuring instrument was used to extrapolate the results at 3 metres to a
   distance of 30 metres where required. A distance extrapolation factor of 40 dB was used.

Results: Quasi Peak / Lower Band Edge

    Frequency               Level                               Limit                                Margin                              Result
      (MHz)               (dBμV/m)                            (dBμV/m)                                (dB)
        13.11               -23.8                                 29.5                                    53.3                          Complied

Results: Quasi Peak / Upper Band Edge

    Frequency               Level                               Limit                                Margin                              Result
      (MHz)               (dBμV/m)                            (dBμV/m)                                (dB)
        14.01               -25.2                                 29.5                                    54.7                          Complied

                                                  Marker 1 [T1]          RBW   10 kHz     RF Att     10 dB
                                   Ref Lvl              -23.83 dBÌ V/m   VBW   30 kHz
                                   60 dB*             13.11000000 MHz    SWT   25 ms      Unit       dBÌ V/m
                              60
                                                                                 1 [T1]     -23.83 dBÌ V/m
                                                                                                           A
                                                                                          13.11000000 MHz
                              50
                                                                                 2 [T1]     -25.24 dBÌ V/m
                                                                                          14.01000000 MHz
                              40



                              30 15225BE                                                                       IN1
                                 1MAX                                                                          1MA

                              20



                              10

                                                                                                               TDF
                               0



                             -10



                             -20
                                      1
                                                                                                      2


                             -30
                                                                                                      F2
                                     F1
                             -40
                                   Start 13.06 MHz                100 kHz/                 Stop 14.06 MHz

                            Title:     90385
                            Comment A: TRANSMITTER RADIATED EMISSIONS
                                        BAND EDGE
                            Date:      17.NOV.2012 09:15:25




Page 24 of 30                                                                                                        RFI Global Services Ltd trading as UL


TEST REPORT                                                                SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                    ISSUE DATE: 30 NOVEMBER 2012



Transmitter Band Edge Radiated Emissions (continued)
Test Equipment Used:

RFI        Instrument                   Manufacturer      Type No.   Serial No.     Date          Cal.
No.                                                                                 Calibration   Interval
                                                                                    Due           (Months)
K0001      5m RSE Chamber               Rainford          N/A        N/A            24 Oct 2013       12
A007       Mag Loop Antenna             Rohde & Schwarz   HFH2-Z2    880 458/020    20 Apr 2013       12
M1273      Test Receiver                Rohde & Schwarz   ESIB 26    1000275        03 Feb 2013       12




RFI Global Services Ltd trading as UL                                                             Page 25 of 30


TEST REPORT                                                                                                  SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                                                        ISSUE DATE: 30 NOVEMBER 2012




5.2.7. Transmitter 20 dB Bandwidth
Test Summary:

Test Engineer:                                 Andrew Edwards                                            Test Date:                  27 November 2012
Test Sample IMEI:                              353740050011927


FCC Reference:                                 Part 2.1049
Test Method Used:                              As detailed in ANSI C63.10 Section 6.9.1

Environmental Conditions:

Temperature (°C):                              23
Relative Humidity (%):                         34

Results:

                                                          20 dB Bandwidth
                                                               (kHz)
                                                                    33.467

                                                     Delta 1 [T1]           RBW   10 kHz        RF Att      0 dB
                                   Ref Lvl                       0.42 dB    VBW   30 kHz
                                    70 dBÌ V              33.46693387 kHz   SWT   15 ms         Unit         dBÌ V
                              70
                                                                                       1 [T1]        31.56 dBÌ V
                                                                                                                 A
                                                                                                13.54326653 MHz
                              60
                                                                                       1 [T1]            0.42 dB
                                                                                                33.46693387 kHz
                                    D1 52 dBÌ V
                              50



                              40                                                                                     IN1
                                   1VIEW                                                                             1MA
                                                             1                     1
                                       D2 32 dBÌ V
                              30



                              20



                              10



                               0



                             -10



                             -20



                             -30
                                   Center 13.56 MHz                   10 kHz/                      Span 100 kHz

                            Title:         90385
                            Date:          27.NOV.2012   18:40:18



Test Equipment Used:

RFI No.     Instrument        Manufacturer                             Type No.                  Serial No.                  Date                Cal.
                                                                                                                             Calibration         Interval
                                                                                                                             Due                 (Months)
M1124       Test Receiver     Rohde & Schwarz                          ESIB 26                   100046K                     14 Aug 2013              12




Page 26 of 30                                                                                                              RFI Global Services Ltd trading as UL


TEST REPORT                                                                    SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                        ISSUE DATE: 30 NOVEMBER 2012




5.2.8. Transmitter Frequency Stability (Temperature & Voltage Variation)
Test Summary:

Test Engineer:                              Andrew Edwards                 Test Date:       28 November 2012
Test Sample IMEI:                           353740050011927


FCC Reference:                              Part 15.225(e)
Test Method Used:                           As detailed in ANSI C63.10 Section 6.8.1 and 6.8.2

Environmental Conditions:

Temperature (°C):                         23
Relative Humidity (%):                    32

Results: Maximum frequency error of the EUT with variations in ambient temperature

                                                             Time after Start-up
Temperature (°C)
                                0 minutes              2 minutes            5 minutes             10 minutes
           -20               13.560249 MHz          13.560251 MHz         13.560251 MHz          13.560250 MHz
           20                13.560126 MHz          13.560121 MHz         13.560119 MHz          13.560118 MHz
           50                13.559980 MHz          13.559974 MHz         13.559971 MHz          13.559970 MHz


Frequency with Worst             Frequency Error         Frequency       Limit (%)      Margin (%)      Result
   Case Deviation                     (Hz)                Error (%)
       (MHz)
        13.560251                       251              0.001851           0.01         0.008149     Complied

Results: Maximum frequency error of the EUT with variations in nominal operating voltage
at an ambient temperature of 20°C

  Supply          Nominal         Measured
                                               Frequency Frequency
  Voltage        Frequency        Frequency                                Limit (%)    Margin (%)     Result
                                               Error (Hz) Error (%)
   (VDC)           (MHz)            (MHz)
     3.4             13.56        13.560111        111        0.000819        0.01       0.009181     Complied
     3.7             13.56        13.560126        126        0.000929        0.01       0.009071     Complied
     4.2             13.56        13.560117        117        0.000863        0.01       0.009137     Complied




RFI Global Services Ltd trading as UL                                                                 Page 27 of 30


TEST REPORT                                                      SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                         ISSUE DATE: 30 NOVEMBER 2012



Transmitter Frequency Stability (Temperature & Voltage Variation) (continued)
Test Equipment Used:

RFI       Instrument        Manufacturer      Type No.     Serial No.    Date                Cal.
No.                                                                      Calibration         Interval
                                                                         Due                 (Months)
E013      Environmental     Sanyo             MTH-4200PR   N/A           Calibrated                -
          Chamber                                                        before use
G088      DC power supply   Thurlby Thandar   CPX200       100700        Calibrated                -
                                                                         before use
M1269     Multimeter        Fluke             179          90250210      30 Jul 2013              12
M1379     Test Receiver     Rohde & Schwarz   ESIB7        100330        15 Oct 2013              12
M1642     Thermometer       Fluke             52II         18890119      21 Feb 2013              12




Page 28 of 30                                                         RFI Global Services Ltd trading as UL


TEST REPORT                                                               SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                                                 ISSUE DATE: 30 NOVEMBER 2012




6. Measurement Uncertainty
No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the
results. Consequently the result of a measurement is only an approximation to the value of the measurand
(the specific quantity subject to measurement) and is only complete when accompanied by a statement of
the uncertainty of the approximation.
The expression of uncertainty of a measurement result allows realistic comparison of results with reference
values and limits given in specifications and standards.
The uncertainty of the result may need to be taken into account when interpreting the measurement results.
The reported expanded uncertainties below are based on a standard uncertainty multiplied by an appropriate
coverage factor such that a confidence level of approximately 95% is maintained. For the purposes of this
document “approximately” is interpreted as meaning “effectively” or “for most practical purposes”.

                                                                                 Confidence     Calculated
Measurement Type                                Range
                                                                                 Level (%)      Uncertainty
AC Conducted Spurious Emissions                 0.15 MHz to 30 MHz               95%            ±3.25 dB
20 dB Bandwidth                                 13 MHz to 14 MHz                 95%            ±0.92 ppm
Frequency Stability                             13 MHz to 14 MHz                 95%            ±0.92 ppm
Radiated Spurious Emissions                     9 kHz to 30 MHz                  95%            ±3.53 dB
Radiated Spurious Emissions                     30 MHz to 1000 MHz               95%            ±2.94 dB
Transmitter Fundamental Field Strength          13 MHz to 14 MHz                 95%            ±3.53 dB

The methods used to calculate the above uncertainties are in line with those recommended within the
various measurement specifications. Where measurement specifications do not include guidelines for the
evaluation of measurement uncertainty the published guidance of the appropriate accreditation body is
followed.




RFI Global Services Ltd trading as UL                                                            Page 29 of 30


TEST REPORT                                             SERIAL NO: UL-RPT-RP90385JD12A

VERSION 1.0                                              ISSUE DATE: 30 NOVEMBER 2012




7. Report Revision History
Version         Revision Details
Number          Page No(s)   Clause   Details
1.0             -            -        Initial Version




Page 30 of 30                                              RFI Global Services Ltd trading as UL



Document Created: 2012-11-30 13:45:35
Document Modified: 2012-11-30 13:45:35

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC