RF Exposure Report

FCC ID: U6Y-RDAA8110

RF Exposure Info

Download: PDF
FCCID_2939586

March 21, 2016

TUV SUD BABT
Octagon House, Concorde Way
Segensworth Rd N, Fareham
PO15 5RL

Attention: Director of Certification

RE: Analysis of RF Exposure for Portable and Mobile use per KDB 447498 D01 Mobile Portable RF
Exposure v05r02 and RSS-102 Issue 5 March 2015.

FCC ID: U6Y-RDAA8110
IC: 216P-RDAA8110


1. Limits

Limits for General Population/Uncontrolled Exposure (Title 47 Subpart J §2.1091 and KDB 447498 D01
referring to limits under §1.1310)

                           Electric Field           Electric Field          Power Density           Averaging Time
 Frequency Range
                           Strength (E)             Strength (H)                  (S)                 (minutes)
      (MHz)
                              (V/m)                    (A/m)                  (mW/cm2)
       0.3 - 1.34               614                     1.63                    *(100)                      30
       1.34 - 30               824/f                   2.19/f                  *(180/f2)                    30
       30 - 300                27.5                     0.073                     0.2                       30
      300 - 1500                 -                        -                     f/1500                      30
   1500 - 100,000                -                        -                       1.0                       30
f = frequency in MHz
*Plane-wave equivalent power density




         TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364


Limits for Devices Used by the General Public (Uncontrolled Environment (RSS-102 Issue 5 March 2015)

                           Electric Field                                                           Reference Period
 Frequency Range                                   Magnetic Field              Power Density
                             Strength                                                                  (minutes)
      (MHz)                                         (A/m rms)                     (W/m2)
                            (V/m rms)
      0.003 - 1021               83                       90                          -                   6**
        0.1 - 10                  -                     0.73/f                        -                   6**
        1.1 - 10               87/f0.5                     -                          -                    6
         10 - 20               27.46                    0.0728                        2                    6
         20 - 48            -58.07/f0.25             0.1540/f0.25                8.944/f0.5                6
        48 - 300               22.06                   0.05852                     1.291                   6
       300 - 6000           3.142 f0.3417          0.008335 f.0.3417           0.02619 f0.6834             6
     6000 - 15000               61.4                    0.163                        10                    6
   15000 - 150000               61.4                    0.163                        10                616000/f1.2
  150000 - 300000            0.158f0.5              4.21 x 10.-4 f0.5           6.67 x 10.-5 f         616000/f1.2
f is frequency in MHz
*Based on nerve stimulation (NS)
** Based on specific absorption rate (SAR)


2. Mobile MPE Calculation Summary using a 25cm separation distance:

                     Output Power         Power Density         Power Density           FCC Limit          IC Limit
     Mode
                        (dBm)*              (mW/cm2)               (W/m2)              (mW/cm2)            (W/m2)
    GSM 850              32.92                0.111                 1.11                  0.55              2.576
   GSM 1850              29.18                0.047                 0.47                    1               4.477
   LTE Band 5             27.42                0.125                    1.25               0.55             2.577
(worst case power)
     LTE B2
                          29.72                 0212                    2.12                1               4.477
(worst case power)
*Since the IC limit is related to the frequency, so the Output Power of the lowest frequency was selcted
as the worst case.


3. *Based on nerve Co-Located Transmitters transmission table:

        Transmitter type                         Transmitter type that can transmit at the same time
GSM 850                                 None
GSM 1900                                None
WCDMA Cell Band 5                       None
WCDMA Cell Band 2                       None
LTE Band 2                              None
LTE Band 5                              None



         TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364


4. Simultaneous Transmission MPE: (N/A)

                            MPE                     FCC Limit                  IC Limit               MPE ratio
 Transmitter type
                          (mw/cm2)                 (mW/cm2)                    (W/m2)                (MPE/Limit)




5. Mobile MPE Calculation using a 20cm separation distance

    Using Power Density formula:
                                                           PG
                                                     S=
                                                          4πRଶ
       where: S = power density
              P = power input to the antenna
              G = power gain of the antenna in the direction of interest relative to isotropic
              R = distance to the center of radiation of the antenna

GSM 850:
                   Maximum peak output power at antenna input terminal:                   32.92          (dBm)
                   Maximum peak output power at antenna input terminal:                 1958.84          (mW)
                                                       Antenna gain(typical):              2.5           (dBi)
                                                     Maximum antenna gain:                1.778          (numeric)
                                                          Prediction distance:             25            (cm)
                                     Sourse Based Time Average Duty Cycle:                 25            (%)
                                                        Prediction frequency:             824.2          (MHz)
                                                                                                                     2
           FCC MPE limit for uncontrolled exposure at prediction frequency:               0.550          (mW/cm )
                                                                                                                 2
            IC MPE limit for uncontrolled exposure at prediction frequency:               2.576          (W/m )
                                                                                                                     2
                                     Power density at prediction frequency:               0.111          (mW/cm )
                                                                                                                 2
                                     Power density at prediction frequency:               1.11           (W/m )
                                                  FCC Margin of Compliance:               -6.96          (dB)
                                                    IC Margin of Compliance:              -3.66          (dB)




        TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364


GSM 1850:
                    Maximum peak output power at antenna input terminal:                   29.18           (dBm)
                    Maximum peak output power at antenna input terminal:                  827.94           (mW)
                                                         Antenna gain(typical):             2.5            (dBi)
                                                       Maximum antenna gain:               1.778           (numeric)
                                                            Prediction distance:             25            (cm)
                                       Sourse Based Time Average Duty Cycle:                 25            (%)
                                                          Prediction frequency:           1850.2           (MHz)
                                                                                                                       2
           FCC MPE limit for uncontrolled exposure at prediction frequency:                 1.0            (mW/cm )
                                                                                                                   2
             IC MPE limit for uncontrolled exposure at prediction frequency:               4.477           (W/m )
                                                                                                                       2
                                       Power density at prediction frequency:              0.047           (mW/cm )
                                                                                                                   2
                                       Power density at prediction frequency:               0.47           (W/m )
                                                    FCC Margin of Compliance:             -13.29           (dB)
                                                      IC Margin of Compliance:              -9.8           (dB)

LTE B5:
                    Maximum peak output power at antenna input terminal:                   27.42           (dBm)
                    Maximum peak output power at antenna input terminal:                  552.08           (mW)
                                                         Antenna gain(typical):             2.5            (dBi)
                                                       Maximum antenna gain:               1.778           (numeric)
                                                            Prediction distance:             25            (cm)
                                       Sourse Based Time Average Duty Cycle:                100            (%)
                                                          Prediction frequency:            824.7           (MHz)
                                                                                                                       2
           FCC MPE limit for uncontrolled exposure at prediction frequency:                 0.55           (mW/cm )
                                                                                                                   2
             IC MPE limit for uncontrolled exposure at prediction frequency:               2.577           (W/m )
                                                                                                                       2
                                       Power density at prediction frequency:              0.125           (mW/cm )
                                                                                                                   2
                                       Power density at prediction frequency:               1.25           (W/m )
                                                    FCC Margin of Compliance:              -6.43           (dB)
                                                      IC Margin of Compliance:             -3.14           (dB)




          TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364


LTE B2:
                     Maximum peak output power at antenna input terminal:                  29.72           (dBm)
                     Maximum peak output power at antenna input terminal:                 937.56           (mW)
                                                         Antenna gain(typical):             2.5            (dBi)
                                                       Maximum antenna gain:               1.778           (numeric)
                                                            Prediction distance:             25            (cm)
                                       Sourse Based Time Average Duty Cycle:                100            (%)
                                                          Prediction frequency:           1850.7           (MHz)
                                                                                                                       2
             FCC MPE limit for uncontrolled exposure at prediction frequency:               1.0            (mW/cm )
                                                                                                                   2
              IC MPE limit for uncontrolled exposure at prediction frequency:              4.477           (W/m )
                                                                                                                       2
                                       Power density at prediction frequency:              0.212           (mW/cm )
                                                                                                                   2
                                       Power density at prediction frequency:               1.25           (W/m )
                                                    FCC Margin of Compliance:              -6.73           (dB)
                                                      IC Margin of Compliance:             -3.24           (dB)




Sincerely,


Xiaoying Zhang
Name
Authorized Signatory
Title: EMC/Wireless Test Engineer




          TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121
                                                                92121-2912
                                                                      2912 Phone: 858 678 1400 FAX: 858 546 0364



Document Created: 2016-03-23 09:53:36
Document Modified: 2016-03-23 09:53:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC